RFC 7637

NVGRE: Network Virtualization Using Generic Routing Encapsulation

๐Ÿ“… published September 2015, from ietf

RFC 7637: NVGRE, Network Virtualization Using Generic Routing Encapsulation ๐ŸŽ€

okay bestie, this one is the NVGRE spec, and it was written by P. Garg, Ed. and Y. Wang, Ed. from Microsoft ๐Ÿ’… It was published in September 2015 as RFC 7637, and its category is Informational. That means it's a published document, not an Internet Standards Track spec, so it's not a standard you're required to follow ๐Ÿงš It's an independent submission to the RFC Series, and it has ISSN 2070-1721. Nothing in the header says it obsoletes or updates another RFC.

Abstract โœจ

okay so the big idea here is using the Generic Routing Encapsulation (GRE) header for Network Virtualization (NVGRE) in multi-tenant data centers ๐Ÿข Network virtualization splits virtual networks and their addresses away from the physical network underneath, so lots of virtual networks can share the same physical network while staying isolated and running side by side ๐Ÿฆ‹ The doc also sketches a network virtualization framework to show the use cases, but the real focus is the data-plane part of NVGRE. the main character here is the data plane ๐Ÿ’–

Status of This Memo โœจ

this doc is not an Internet Standards Track spec, it's just published for info ๐ŸŒธ It's a contribution to the RFC Series, independent of any other RFC stream. The RFC Editor picked to publish it at their discretion and makes no claims about how useful it is to implement or deploy ๐Ÿ™ˆ Docs the RFC Editor approves aren't candidates for any level of Internet Standard. (See Section 2 of RFC 5741 if you want the details.)

for the current status, errata, and how to send feedback, check http://www.rfc-editor.org/info/rfc7637 ๐Ÿ”—

ยฉ 2015 IETF Trust and the persons identified as the document authors. All rights reserved ๐Ÿ’œ

this doc is subject to BCP 78 and the IETF Trust's Legal Provisions Relating to IETF Documents (http://trustee.ietf.org/license-info) as they were on the publication date. please read these carefully, bestie, because they describe your rights and restrictions for this document ๐Ÿ“œ

Table of Contents ๐Ÿงš

1. Introduction ....................................................2
   1.1. Terminology ................................................4
2. Conventions Used in This Document ...............................4
3. Network Virtualization Using GRE (NVGRE) ........................4
   3.1. NVGRE Endpoint .............................................5
   3.2. NVGRE Frame Format .........................................5
   3.3. Inner Tag as Defined by IEEE 802.1Q ........................8
   3.4. Reserved VSID ..............................................8
4. NVGRE Deployment Considerations .................................9
   4.1. ECMP Support ...............................................9
   4.2. Broadcast and Multicast Traffic ............................9
   4.3. Unicast Traffic ............................................9
   4.4. IP Fragmentation ..........................................10
   4.5. Address/Policy Management and Routing .....................10
   4.6. Cross-Subnet, Cross-Premise Communication .................10
   4.7. Internet Connectivity .....................................12
   4.8. Management and Control Planes .............................12
   4.9. NVGRE-Aware Devices .......................................12
   4.10. Network Scalability with NVGRE ...........................13
5. Security Considerations ........................................14
6. Normative References ...........................................14
Contributors ......................................................16
Authors' Addresses ................................................17

1. Introduction ๐Ÿ’–

okay so conventional data center designs are built for mostly static workloads, and that causes fragmentation of network and server capacity [6] [7] ๐Ÿ˜ญ A few things stop capacity from being allocated dynamically and consolidated. Layer 2 networks use the Rapid Spanning Tree Protocol (RSTP), which is designed to kill loops by blocking redundant paths. those blocked paths turn into wasted capacity and a highly oversubscribed network ๐Ÿ’€ There are alternatives, like the Transparent Interconnection of Lots of Links (TRILL), that tackle this problem [13].

the utilization problems get worse because VLANs fragment the network for broadcast isolation ๐ŸŒˆ VLANs are used for traffic management and also as the way to give security and performance isolation to services that belong to different tenants. The Layer 2 network gets carved into smaller subnets (usually one subnet per VLAN), with VLAN tags configured on every Layer 2 switch connected to the server racks that host a given tenant's services. The current VLAN limits theoretically allow for 4,000 such subnets. The broadcast domain is usually kept small because broadcast traffic has overhead. And the 4,000-subnet VLAN limit is no longer enough in a shared infrastructure serving multiple tenants ๐Ÿ™ˆ

data center operators need to reach high utilization of server and network capacity, periodt ๐Ÿ”ฅ To get there, it should be possible to assign workloads that operate in a single Layer 2 network to any server in any rack. It should also be possible to migrate workloads to any server anywhere in the network while keeping their addresses. You can do this today by stretching VLANs, but when workloads migrate, the network has to be reconfigured, and that's usually error prone ๐Ÿ˜ฌ If you decouple the workload's location on the LAN from its network address, the admin configures the network once, not every single time a service moves. That decoupling lets any server become part of any server resource pool โœจ

the key design objectives for next-gen data centers are:

  • a) location-independent addressing
  • b) the ability to scale the number of logical Layer 2 / Layer 3 networks, regardless of the underlying physical topology or the number of VLANs
  • c) preserving Layer 2 semantics for services and letting them keep their addresses as they move within and across data centers
  • d) providing broadcast isolation as workloads move around, without burdening the network control plane

this doc describes using the Generic Routing Encapsulation (GRE) header [3] [4] for network virtualization ๐Ÿฆ‹ Network virtualization decouples a virtual network from the physical network underneath by virtualizing network addresses. Combine that with a management and control plane for the virtual-to-physical mapping, and you get flexible VM placement and movement plus network isolation for a multi-tenant data center. it's giving clean separation ๐Ÿ’…

network virtualization also lets customers bring their own address spaces into a multi-tenant data center. Meanwhile, data center admins can place customer VMs anywhere in the data center without reconfiguring their switches or routers, no matter what the customer address spaces are ๐Ÿ‘‘

1.1. Terminology ๐Ÿงš

please check RFCs 7364 [10] and 7365 [11] for more formal definitions of terminology. These are the terms this doc uses:

Customer Address (CA): This is the virtual IP address assigned and configured on the virtual Network Interface Controller (NIC) inside each VM. It's the only address VMs and the apps running inside them can see ๐Ÿ‘€

Network Virtualization Edge (NVE): This is an entity that does the network virtualization encapsulation and decapsulation ๐Ÿซถ

Provider Address (PA): This is the IP address used in the physical network. PAs are associated with VM CAs through the network virtualization mapping policy ๐ŸŒธ

Virtual Machine (VM): This is an instance of an OS running on top of the hypervisor over a physical machine or server. Multiple VMs can share the same physical server through the hypervisor, yet they're completely isolated from each other in terms of CPU usage, storage, and other OS resources ๐Ÿ’œ

Virtual Subnet Identifier (VSID): This is a 24-bit ID that uniquely identifies a virtual subnet or virtual Layer 2 broadcast domain โœจ

2. Conventions Used in This Document ๐Ÿ“œ

the key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in RFC 2119 [1].

in this document these words only carry that meaning when they're in ALL CAPS. Lowercase uses of these words don't carry the significance defined in RFC 2119 ๐Ÿ™ˆ

3. Network Virtualization Using GRE (NVGRE) โœจ

this section describes Network Virtualization using GRE (NVGRE) ๐Ÿฆ‹ Network virtualization means creating virtual Layer 2 topologies on top of a physical Layer 3 network. Connectivity in the virtual topology comes from tunneling Ethernet frames in GRE over IP over the physical network ๐ŸŒˆ

in NVGRE, every virtual Layer 2 network is tied to a 24-bit identifier called a Virtual Subnet Identifier (VSID) ๐ŸŽ€ The VSID is carried in an outer header, as defined in Section 3.2. That lets various devices in the network uniquely identify a tenant's virtual subnet. A 24-bit VSID supports up to 16 million virtual subnets in the same management domain, compared to only 4,000 with VLANs. Each VSID is a virtual Layer 2 broadcast domain, which can be used to identify a given tenant's virtual subnet. For multi-subnet virtual topologies, data center admins can configure routes so that virtual subnets of the same tenant can talk to each other ๐Ÿ’–

GRE is a Proposed Standard from the IETF [3] [4], and it's a way to encapsulate an arbitrary protocol over IP ๐Ÿงš NVGRE uses the GRE header to carry VSID information in each packet. That VSID info can be used to build multi-tenant-aware tools for traffic analysis, traffic inspection, and monitoring ๐Ÿ‘‘

the next sections cover the NVGRE packet format, describe what an NVGRE endpoint does, show typical traffic flow within and across data centers, and talk about address/policy management and deployment considerations ๐Ÿ“œ

3.1. NVGRE Endpoint ๐Ÿซถ

NVGRE endpoints are the ingress/egress points between the virtual and physical networks ๐ŸŒธ They're the NVEs defined in the Network Virtualization over Layer 3 (NVO3) Framework document [11]. Any physical server or network device can be an NVGRE endpoint, and a common setup is to have the endpoint be part of a hypervisor ๐Ÿ’… The main job of the endpoint is to encapsulate and decapsulate Ethernet data frames to and from the GRE tunnel, keep Layer 2 semantics intact, and apply isolation policy scoped on VSID ๐Ÿ”ฅ The endpoint can optionally take part in routing and act as a gateway in the virtual topology โœจ To encapsulate an Ethernet frame, the endpoint needs to know the location information for the destination address in that frame. That info can be provisioned through a management plane, or obtained through a combo of control-plane distribution and data-plane learning approaches ๐Ÿฆ‹ This doc assumes the location information, including the VSID, is available to the NVGRE endpoint ๐Ÿ’œ


that's part 1 of 4 bestie, so more is coming ๐ŸŽ€ Next up is the NVGRE frame format and everything after it ๐ŸŒˆ

3.2. NVGRE Frame Format โœจ

okay bestie, NVGRE endpoints talk to each other using the GRE header from RFCs 2784 [3] and 2890 [4] ๐Ÿงš and NVGRE borrows the Key extension from RFC 2890 [4] to carry the VSID ๐Ÿ’–. Here's the Layer 2 encapsulation in GRE, Figure 1, and it is giving detailed ๐Ÿ˜ญ๐ŸŽ€

   Outer Ethernet Header:
    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                (Outer) Destination MAC Address                |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |(Outer)Destination MAC Address |  (Outer)Source MAC Address    |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                  (Outer) Source MAC Address                   |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |Optional Ethertype=C-Tag 802.1Q| Outer VLAN Tag Information    |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |       Ethertype 0x0800        |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Outer IPv4 Header:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |Version|  HL   |Type of Service|          Total Length         |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |         Identification        |Flags|      Fragment Offset    |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |  Time to Live | Protocol 0x2F |         Header Checksum       |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                      (Outer) Source Address                   |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                  (Outer) Destination Address                  |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   GRE Header:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |0| |1|0|   Reserved0     | Ver |   Protocol Type 0x6558        |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |               Virtual Subnet ID (VSID)        |    FlowID     |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   Inner Ethernet Header
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                (Inner) Destination MAC Address                |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |(Inner)Destination MAC Address |  (Inner)Source MAC Address    |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                  (Inner) Source MAC Address                   |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |       Ethertype 0x0800        |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   Inner IPv4 Header:
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |Version|  HL   |Type of Service|          Total Length         |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |         Identification        |Flags|      Fragment Offset    |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |  Time to Live |    Protocol   |         Header Checksum       |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                       Source Address                          |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                    Destination Address                        |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                    Options                    |    Padding    |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
   |                      Original IP Payload                      |
   |                                                               |
   |                                                               |
   +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

               Figure 1: GRE Encapsulation Frame Format

Note: HL stands for Header Length. ๐Ÿ™ˆ

The outer/delivery headers are the outer Ethernet header plus the outer IP header ๐Ÿฆ‹:

  • The outer Ethernet header: the source Ethernet address in the outer frame is set to the MAC address associated with the NVGRE endpoint. The destination endpoint may or may not be on the same physical subnet. The destination Ethernet address is set to the MAC address of the next-hop IP address for the destination NVE. The outer VLAN tag information is optional and can be used for traffic management and broadcast scalability on the physical network. ๐Ÿซถ
  • The outer IP header: both IPv4 and IPv6 can be used as the delivery protocol for GRE. The IPv4 header is shown for illustrative purposes. Henceforth, the IP address in the outer frame is referred to as the Provider Address (PA). There can be one or more PA associated with an NVGRE endpoint, with policy controlling the choice of which PA to use for a given Customer Address (CA) for a customer VM. ๐Ÿ‘‘

Now the GRE header ๐ŸŒธ:

  • The C (Checksum Present) and S (Sequence Number Present) bits in the GRE header MUST be zero. ๐Ÿ™…
  • The K (Key Present) bit in the GRE header MUST be set to one. The 32-bit Key field in the GRE header is used to carry the Virtual Subnet ID (VSID) and the FlowID ๐Ÿ”ฅ:
    • Virtual Subnet ID (VSID): this is a 24-bit value that is used to identify the NVGRE-based Virtual Layer 2 Network. ๐Ÿ’œ
    • FlowID: this is an 8-bit value that is used to provide per-flow entropy for flows in the same VSID. The FlowID MUST NOT be modified by transit devices. The encapsulating NVE SHOULD provide as much entropy as possible in the FlowID. If a FlowID is not generated, it MUST be set to all zeros. ๐Ÿ“
  • The Protocol Type field in the GRE header is set to 0x6558 (Transparent Ethernet Bridging) [2]. โœจ

And the inner headers, aka the headers of the GRE payload ๐Ÿง:

  • The inner Ethernet frame comprises an inner Ethernet header, followed by an optional inner IP header, followed by the IP payload. The inner frame could be any Ethernet data frame, not just IP. Note that the inner Ethernet frame's Frame Check Sequence (FCS) is not encapsulated. ๐ŸŒˆ
  • For illustrative purposes, IPv4 headers are shown as the inner IP headers, but IPv6 headers may be used. Henceforth, the IP address contained in the inner frame is referred to as the Customer Address (CA). ๐Ÿ’…

3.3. Inner Tag as Defined by IEEE 802.1Q ๐ŸŽ€

Okay, so the inner Ethernet header of NVGRE MUST NOT contain the tag as defined by IEEE 802.1Q [5]. ๐Ÿ™…โ€โ™€๏ธ The encapsulating NVE MUST remove any existing IEEE 802.1Q tag before encapsulation of the frame in NVGRE. A decapsulating NVE MUST drop the frame if the inner Ethernet frame contains an IEEE 802.1Q tag. ๐Ÿ’€

No tags allowed inside the NVGRE bubble. Strip it going in, drop it coming out. ๐Ÿซถ

3.4. Reserved VSID ๐Ÿฆ‹

The VSID range from 0-0xFFF is reserved for future use. ๐Ÿงš

The VSID 0xFFFFFF is reserved for vendor-specific NVE-to-NVE communication. The sender NVE SHOULD verify the receiver NVE's vendor before sending a packet using this VSID; however, such a verification mechanism is out of scope of this document. Implementations SHOULD choose a mechanism that meets their requirements. ๐Ÿ‘€๐Ÿ’–


4. NVGRE Deployment Considerations ๐ŸŒธ

4.1. ECMP Support ๐Ÿ’…

Equal-Cost Multipath (ECMP) may be used to provide load balancing. If ECMP is used, it is RECOMMENDED that the ECMP hash is calculated either using the outer IP frame fields and entire Key field (32 bits) or the inner IP and transport frame fields. โญ

4.2. Broadcast and Multicast Traffic ๐Ÿ“ฃ

To support broadcast and multicast traffic inside a virtual subnet, one or more administratively scoped multicast addresses [8] [9] can be assigned for the VSID. All multicast or broadcast traffic originating from within a VSID is encapsulated and sent to the assigned multicast address. From an administrative standpoint, it is possible for network operators to configure a PA multicast address for each multicast address that is used inside a VSID; this facilitates optimal multicast handling. Depending on the hardware capabilities of the physical network devices and the physical network architecture, multiple virtual subnets may use the same physical IP multicast address. ๐Ÿง 

Alternatively, based upon the configuration at the NVE, broadcast and multicast in the virtual subnet can be supported using N-way unicast. In N-way unicast, the sender NVE would send one encapsulated packet to every NVE in the virtual subnet. The sender NVE can encapsulate and send the packet as described in Section 4.3 ("Unicast Traffic"). This alleviates the need for multicast support in the physical network. ๐Ÿ“

4.3. Unicast Traffic ๐Ÿงšโ€โ™€๏ธ

The NVGRE endpoint encapsulates a Layer 2 packet in GRE using the source PA associated with the endpoint, with the destination PA corresponding to the location of the destination endpoint. As outlined earlier, there can be one or more PAs associated with an endpoint, and policy will control which ones get used for communication. The encapsulated GRE packet is bridged and routed normally by the physical network to the destination PA. Bridging uses the outer Ethernet encapsulation for scope on the LAN. The only requirement is bidirectional IP connectivity from the underlying physical network. On the destination, the NVGRE endpoint decapsulates the GRE packet to recover the original Layer 2 frame. Traffic flows similarly on the reverse path. ๐Ÿ”โœจ

4.4. IP Fragmentation ๐Ÿงฉ

Section 5.1 of RFC 2003 [12] specifies mechanisms for handling fragmentation when encapsulating IP within IP. The subset of mechanisms NVGRE selects are intended to ensure that NVGRE-encapsulated frames are not fragmented after encapsulation en route to the destination NVGRE endpoint, and that traffic sources can leverage Path MTU discovery. ๐Ÿ›ฃ๏ธ

A sender NVE MUST NOT fragment NVGRE packets. A receiver NVE MAY discard fragmented NVGRE packets. It is RECOMMENDED that the MTU of the physical network accommodates the larger frame size due to encapsulation. Path MTU or configuration via control plane can be used to meet this requirement. ๐Ÿ“๐Ÿ’œ

Don't fragment it, bestie. The sender NVE MUST NOT fragment, so the physical network needs room for the bigger frame. ๐Ÿšซ

4.5. Address/Policy Management and Routing ๐Ÿ—บ๏ธ

Address acquisition is beyond the scope of this document and can be obtained statically, dynamically, or using stateless address autoconfiguration. CA and PA space can be either IPv4 or IPv6. In fact, the address families don't have to match; for example, a CA can be IPv4 while the PA is IPv6, and vice versa. ๐ŸŒˆโœจ

4.6. Cross-Subnet, Cross-Premise Communication ๐ŸŒธ

Okay so this framework is giving enterprises a seamless path to expand their VM hosting into public clouds ๐Ÿš€. They can bring their entire IP subnet(s) and isolation policies over, which makes moving to or from the cloud way simpler ๐Ÿ’–. It is possible to move portions of an IP subnet to the cloud, but that needs extra configuration on the enterprise network, and this document doesn't go into it ๐Ÿ™ˆ. Enterprises can keep using existing models like site-to-site VPN to secure their traffic ๐Ÿ”.

A VPN gateway sets up a secure site-to-site tunnel over the Internet, and all the enterprise services running in VMs in the cloud use that gateway to talk back to the enterprise โœจ. To keep things simple, we use a VPN gateway configured as a VM (shown in Figure 2) to show cross-subnet, cross-premise communication ๐ŸŽ€.

   +-----------------------+        +-----------------------+
   |       Server 1        |        |       Server 2        |
   | +--------+ +--------+ |        | +-------------------+ |
   | | VM1    | | VM2    | |        | |    VPN Gateway    | |
   | | IP=CA1 | | IP=CA2 | |        | | Internal  External| |
   | |        | |        | |        | |  IP=CAg   IP=GAdc | |
   | +--------+ +--------+ |        | +-------------------+ |
   |       Hypervisor      |        |     | Hypervisor| ^   |
   +-----------------------+        +-------------------:---+
               | IP=PA1                   | IP=PA4    | :
               |                          |           | :
               |     +-------------------------+      | : VPN
               +-----|     Layer 3 Network     |------+ : Tunnel
                     +-------------------------+        :
                                  |                     :
        +-----------------------------------------------:--+
        |                                               :  |
        |                     Internet                  :  |
        |                                               :  |
        +-----------------------------------------------:--+
                                  |                     v
                                  |   +-------------------+
                                  |   |    VPN Gateway    |
                                  |---|                   |
                             IP=GAcorp| External IP=GAcorp|
                                      +-------------------+
                                                |
                                    +-----------------------+
                                    |  Corp Layer 3 Network |
                                    |      (In CA Space)    |
                                    +-----------------------+
                                                |
                                   +---------------------------+
                                   |       Server X            |
                                   | +----------+ +----------+ |
                                   | | Corp VMe1| | Corp VMe2| |
                                   | |  IP=CAe1 | |  IP=CAe2 | |
                                   | +----------+ +----------+ |
                                   |         Hypervisor        |
                                   +---------------------------+

Figure 2: Cross-Subnet, Cross-Premise Communication

The packet flow is pretty similar to unicast traffic between VMs, but the big difference here is that the packet has to go to a VPN gateway before it gets forwarded to its destination ๐Ÿฆ‹. As part of the routing config in the CA space, a per-tenant VPN gateway gets provisioned for talking back to the enterprise ๐Ÿ’…. The example shows an outbound connection from VM1 inside the data center to VMe1 inside the enterprise network ๐Ÿ‘‘. When the outbound packet from CA1 to CAe1 hits the hypervisor on Server 1, the NVE on Server 1 can do the equivalent of a route lookup on it ๐Ÿ”. The cross-premise packet matches the default gateway rule, since CAe1 isn't part of the tenant virtual network in the data center ๐Ÿ™ƒ. The virtualization policy says to encapsulate the packet and send it to the PA of the tenant VPN gateway (PA4), which runs as a VM on Server 2 ๐Ÿงš. The packet gets decapsulated on Server 2 and delivered to the VM gateway ๐Ÿ“ฆ. The gateway then validates the packet and sends it down the site-to-site VPN tunnel back to the enterprise network ๐Ÿ”. Since this communication is external to the data center, the PA address for the VPN tunnel is globally routable ๐ŸŒ. The outer header of this packet is sourced from GAdc and destined to GAcorp ๐Ÿ“ฎ. It gets routed through the Internet to the enterprise VPN gateway, which is the other end of the site-to-site tunnel ๐Ÿ›ฃ๏ธ. At that point, the VPN gateway decapsulates the packet and sends it inside the enterprise, where CAe1 is routable on the network ๐Ÿข. The reverse path works similarly once the packet reaches the enterprise VPN gateway ๐Ÿ”.

4.7. Internet Connectivity ๐ŸŒ

To get connected to the Internet, you need an Internet gateway that bridges the virtualized CA space to the public Internet address space ๐ŸŒ‰. That gateway has to translate between the virtualized world and the Internet ๐Ÿ”„. For example, the NVGRE endpoint can be part of a load balancer or a NAT that replaces the VPN Gateway on Server 2 shown in Figure 2 โš–๏ธ.

4.8. Management and Control Planes ๐ŸŽ›๏ธ

There are several protocols that can manage and distribute policy, but that's outside the scope of this document ๐Ÿคทโ€โ™€๏ธ. Implementations SHOULD choose a mechanism that meets their scale requirements. ๐Ÿ’œ

4.9. NVGRE-Aware Devices ๐Ÿง 

One typical deployment looks like virtualized servers spread across multiple racks, connected by one or more layers of Layer 2 switches, which may in turn connect to a Layer 3 routing domain ๐Ÿ—๏ธ. Routing in the physical infrastructure works without any modification with NVGRE, but devices that do specialized processing in the network need to parse GRE to get access to tenant-specific information ๐Ÿ‘€. Devices that understand and parse the VSID can provide rich multi-tenant-aware services inside the data center ๐Ÿ’Ž. As we outlined earlier, it's imperative to exploit multiple paths inside the network using techniques like ECMP ๐Ÿ›ค๏ธ. The Key field (a 32-bit field, including both the VSID and the optional FlowID) can give switches extra entropy to exploit path diversity inside the network โœจ. A diverse ecosystem is expected to emerge as more and more devices become multi-tenant aware ๐ŸŒˆ. In the meantime, without any hardware upgrades, you can exploit path diversity with GRE by associating multiple PAs with NVGRE endpoints, with policy controlling which PA gets used ๐Ÿฆ„.

Communication is expected to span multiple data centers and also cross the virtual/physical boundary ๐ŸŒ. Typical scenarios that need virtual-to-physical communication include access to storage and databases ๐Ÿ—„๏ธ. Scenarios demanding lossless Ethernet functionality may not be amenable to NVGRE, since the traffic is carried over an IP network ๐Ÿšซ. NVGRE endpoints mediate between the network-virtualized and non-network-virtualized environments ๐Ÿค. That functionality can be built into Top-of-Rack switches, storage appliances, load balancers, routers, etc., or made as a stand-alone appliance ๐Ÿ“ฆ.

It's imperative to consider the impact of any solution on host performance ๐ŸŽ๏ธ. Today's server operating systems use sophisticated acceleration techniques like checksum offload, Large Send Offload (LSO), Receive Segment Coalescing (RSC), Receive Side Scaling (RSS), Virtual Machine Queue (VMQ), etc. ๐Ÿ’… These technologies should become NVGRE aware. IPsec Security Associations (SAs) can be offloaded to the NIC so that computationally expensive cryptographic operations run at line rate in the NIC hardware ๐Ÿ”ฅ. These SAs are based on the IP addresses of the endpoints ๐Ÿ“. As each packet on the wire gets translated, the NVGRE endpoint SHOULD intercept the offload requests and do the appropriate address translation. ๐Ÿ™Œ This keeps IPsec usable with network virtualization while still taking advantage of hardware offload for better performance ๐Ÿ’–.

4.10. Network Scalability with NVGRE ๐Ÿ“ˆ

One of the key benefits of NVGRE is the IP address scalability, and in turn the MAC address table scalability, that you can get ๐Ÿ˜. An NVGRE endpoint can use one PA to represent multiple CAs, which lowers the burden on MAC address table sizes at the Top-of-Rack switches ๐Ÿง. This is a big deal in server virtualization, which has ramped up the demands on the network infrastructure ๐Ÿ“Š. By embedding an NVGRE endpoint in a hypervisor, you can scale way up ๐Ÿš€. This framework lets location information be preconfigured inside an NVGRE endpoint, so broadcast ARP traffic can be proxied locally ๐Ÿช„. That approach scales to large virtual subnets ๐Ÿ˜. These virtual subnets can be spread across multiple Layer 3 physical subnets โœจ. It lets workloads move around without putting a huge burden on the network control plane ๐Ÿƒโ€โ™€๏ธ. By eliminating most broadcast traffic and converting the rest to multicast, routers and switches can run more optimally by building efficient multicast trees ๐ŸŒณ. By using server and network capacity efficiently, you can drive down the cost of building and managing data centers ๐Ÿ’ธ.

5. Security Considerations ๐Ÿ”

This proposal extends the Layer 2 subnet across the data center and increases the scope for spoofing attacks. ๐Ÿ˜ฑ Mitigations for such attacks are possible with authentication/encryption using IPsec or any other IP-based mechanism ๐Ÿ›ก๏ธ. The control plane for policy distribution is expected to be secured using any of the existing security protocols ๐Ÿ”’. Further, management traffic can be isolated in a separate subnet/VLAN ๐Ÿ™Œ.

The checksum in the GRE header is not supported. ๐Ÿ’€ The mitigation is to deploy an NVGRE-based solution in a network that provides error detection along the NVGRE packet path, for example using Ethernet Cyclic Redundancy Check (CRC), IPsec, or any other error detection mechanism ๐Ÿงฏ.

6. Normative References โœจ

okay bestie, this is the reading list ๐Ÿ“š๐Ÿ’… every doc it's citing has to be here, so no skipping, no cap. the titles and details are copied exactly, since you can't cite a vibe ๐Ÿ™ˆ

[1]  Bradner, S., "Key words for use in RFCs to Indicate Requirement
     Levels", BCP 14, RFC 2119, DOI 10.17487/RFC2119, March 1997,
     <http://www.rfc-editor.org/info/rfc2119>.

[2]  IANA, "IEEE 802 Numbers",
     <http://www.iana.org/assignments/ieee-802-numbers>.

[3]  Farinacci, D., Li, T., Hanks, S., Meyer, D., and P. Traina,
     "Generic Routing Encapsulation (GRE)", RFC 2784,
     DOI 10.17487/RFC2784, March 2000,
     <http://www.rfc-editor.org/info/rfc2784>.

[4]  Dommety, G., "Key and Sequence Number Extensions to GRE",
     RFC 2890, DOI 10.17487/RFC2890, September 2000,
     <http://www.rfc-editor.org/info/rfc2890>.

[5]  IEEE, "IEEE Standard for Local and metropolitan area
     networks--Media Access Control (MAC) Bridges and Virtual Bridged
     Local Area Networks", IEEE Std 802.1Q.

[6]  Greenberg, A., et al., "VL2: A Scalable and Flexible Data Center
     Network", Communications of the ACM,
     DOI 10.1145/1897852.1897877, 2011.

[7]  Greenberg, A., et al., "The Cost of a Cloud: Research Problems
     in Data Center Networks", ACM SIGCOMM Computer Communication
     Review, DOI 10.1145/1496091.1496103, 2009.

[8]  Hinden, R. and S. Deering, "IP Version 6 Addressing
     Architecture", RFC 4291, DOI 10.17487/RFC4291, February 2006,
     <http://www.rfc-editor.org/info/rfc4291>.

[9]  Meyer, D., "Administratively Scoped IP Multicast", BCP 23,
     RFC 2365, DOI 10.17487/RFC2365, July 1998,
     <http://www.rfc-editor.org/info/rfc2365>.

[10] Narten, T., Ed., Gray, E., Ed., Black, D., Fang, L., Kreeger,
     L., and M. Napierala, "Problem Statement: Overlays for Network
     Virtualization", RFC 7364, DOI 10.17487/RFC7364, October 2014,
     <http://www.rfc-editor.org/info/rfc7364>.

[11] Lasserre, M., Balus, F., Morin, T., Bitar, N., and Y. Rekhter,
     "Framework for Data Center (DC) Network Virtualization",
     RFC 7365, DOI 10.17487/RFC7365, October 2014,
     <http://www.rfc-editor.org/info/rfc7365>.

[12] Perkins, C., "IP Encapsulation within IP", RFC 2003,
     DOI 10.17487/RFC2003, October 1996,
     <http://www.rfc-editor.org/info/rfc2003>.

[13] Touch, J. and R. Perlman, "Transparent Interconnection of Lots
     of Links (TRILL): Problem and Applicability Statement",
     RFC 5556, DOI 10.17487/RFC5556, May 2009,
     <http://www.rfc-editor.org/info/rfc5556>.

Contributors ๐ŸŽ€

these legends helped make the doc, and they're all listed here with their addresses ๐Ÿซถ

Murari Sridharan
Microsoft Corporation
1 Microsoft Way
Redmond, WA 98052
United States
Email: muraris@microsoft.com

Albert Greenberg
Microsoft Corporation
1 Microsoft Way
Redmond, WA 98052
United States
Email: albert@microsoft.com

Narasimhan Venkataramiah
Microsoft Corporation
1 Microsoft Way
Redmond, WA 98052
United States
Email: navenkat@microsoft.com

Kenneth Duda
Arista Networks, Inc.
5470 Great America Pkwy
Santa Clara, CA 95054
United States
Email: kduda@aristanetworks.com

Ilango Ganga
Intel Corporation
2200 Mission College Blvd.
M/S: SC12-325
Santa Clara, CA 95054
United States
Email: ilango.s.ganga@intel.com

Geng Lin
Google
1600 Amphitheatre Parkway
Mountain View, CA 94043
United States
Email: genglin@google.com
Mark Pearson
Hewlett-Packard Co.
8000 Foothills Blvd.
Roseville, CA 95747
United States
Email: mark.pearson@hp.com

Patricia Thaler
Broadcom Corporation
3151 Zanker Road
San Jose, CA 95134
United States
Email: pthaler@broadcom.com

Chait Tumuluri
Emulex Corporation
3333 Susan Street
Costa Mesa, CA 92626
United States
Email: chait@emulex.com

Authors' Addresses ๐Ÿ’–

and last but definitely not least, the editors who held this whole thing together ๐Ÿ‘‘โœจ

Pankaj Garg (editor)
Microsoft Corporation
1 Microsoft Way
Redmond, WA 98052
United States
Email: pankajg@microsoft.com

Yu-Shun Wang (editor)
Microsoft Corporation
1 Microsoft Way
Redmond, WA 98052
United States
Email: yushwang@microsoft.com

that's the whole RFC, bestie ๐ŸŒˆ๐Ÿฆ‹ we made it through all the parts ๐Ÿฅน๐Ÿ’œ