RFC 7453
MPLS Transport Profile (MPLS-TP) Traffic Engineering (TE) Management Information Base (MIB)
RFC 7453: MPLS Transport Profile (MPLS-TP) Traffic Engineering (TE) Management Information Base (MIB) β¨
okay bestie, let's get into this one π it's an official IETF Standards Track doc from February 2015, so it's a real Internet standard π here's the lowdown on the title block:
- Authors: M. Venkatesan (Dell Inc.), K. Sampath (Redeem), S. Aldrin (Huawei Technologies), and T. Nadeau (Brocade) π
- Category: Standards Track π₯
- Date: February 2015 π
- ISSN: 2070-1721
- Obsoletes and updates: the header doesn't list any, so there's nothing to obsolete or update here π
Abstract
okay so this memo defines a piece of the Management Information Base (MIB) that network management protocols use across the Internet community π¦ it adds extra managed objects and textual conventions for tunnels, identifiers, and Label Switching Routers so that Multiprotocol Label Switching (MPLS) MIB modules can handle transport networks. it's giving full toolkit energy β¨
Status of This Memo
this is an Internet Standards Track document πΈ
this doc is a product of the Internet Engineering Task Force (IETF) π it represents the consensus of the IETF community, it went through public review, and the Internet Engineering Steering Group (IESG) approved it for publication. if you want more on Internet Standards, check out Section 2 of RFC 5741 π
info about the current status of this doc, any errata, and how to send feedback lives at http://www.rfc-editor.org/info/rfc7453 π
Copyright Notice
the legal bit, but make sure you read it π«Ά the copyright line says:
Copyright (c) 2015 IETF Trust and the persons identified as the
document authors. All rights reserved.
this doc is subject to BCP 78 and the IETF Trust's Legal Provisions Relating to IETF Documents (http://trustee.ietf.org/license-info) as they stood on the publication date. read those carefully, because they spell out your rights and restrictions for this doc π any Code Components pulled out of this document must include Simplified BSD License text, as described in Section 4.e of the Trust Legal Provisions, and they come without warranty, as described in the Simplified BSD License π
Table of Contents
1. Introduction ....................................................4
2. The Internet-Standard Management Framework ......................5
3. Overview ........................................................5
3.1. Conventions Used in This Document ..........................5
3.2. Terminology ................................................6
3.3. Acronyms ...................................................6
4. Motivations .....................................................6
5. Feature List ....................................................7
6. Outline .........................................................7
6.1. MIB Module Extensions ......................................8
6.1.1. Summary of MIB Module Changes .......................8
6.2. MPLS-TE-EXT-STD-MIB ........................................9
6.2.1. mplsTunnelExtNodeConfigTable ........................9
6.2.2. mplsTunnelExtNodeIpMapTable .........................9
6.2.3. mplsTunnelExtNodeIccMapTable .......................10
6.2.4. mplsTunnelExtTable .................................10
6.3. MPLS-TC-EXT-STD-MIB .......................................10
6.4. MPLS-ID-STD-MIB ...........................................10
6.5. MPLS-LSR-EXT-STD-MIB ......................................11
6.6. The Use of RowPointer .....................................11
7. MIB Modules' Interdependencies .................................11
8. Dependencies between MIB Module Tables .........................13
9. Example of MPLS-TP Tunnel Setup ................................13
9.1. Example of MPLS-TP Static Co-routed Bidirectional
Tunnel Setup ..............................................15
9.1.1. mplsTunnelEntry ....................................15
9.1.2. mplsTunnelExtEntry .................................16
9.1.3. Forward-Direction mplsOutSegmentEntry ..............16
9.1.4. Reverse-Direction mplsInSegmentEntry ...............16
9.1.5. Forward-Direction mplsXCEntry ......................17
9.1.6. Reverse-Direction mplsXCEntry ......................17
9.1.7. Forward-Direction mplsXCExtEntry ...................18
9.1.8. Reverse-Direction mplsXCExtEntry ...................18
9.2. Example of MPLS-TP Static Associated Bidirectional
Tunnel Setup ..............................................18
9.2.1. Forward-Direction mplsTunnelEntry ..................18
9.2.2. Forward-Direction mplsTunnelExtEntry ...............19
9.2.3. Forward-Direction mplsOutSegmentTable ..............20
9.2.4. Forward-Direction mplsXCEntry ......................20
9.2.5. Forward-Direction mplsXCExtEntry ...................20
9.2.6. Reverse-Direction mplsTunnelEntry ..................21
9.2.7. Reverse-Direction mplsTunnelExtEntry ...............22
9.2.8. Reverse-Direction mplsInSegmentEntry ...............22
9.2.9. Reverse-Direction mplsXCEntry ......................22
9.2.10. Reverse-Direction mplsXCExtEntry ..................23
9.3. Example of MPLS-TP Signaled Co-routed
Bidirectional Tunnel Setup ................................23
9.3.1. mplsTunnelEntry ....................................23
9.3.2. mplsTunnelExtEntry .................................24
9.3.3. Forward-Direction mplsOutSegmentEntry ..............24
9.3.4. Reverse-Direction mplsInSegmentEntry ...............25
9.3.5. Forward-Direction mplsXCEntry ......................25
9.3.6. Reverse-Direction mplsXCEntry ......................25
9.3.7. Forward-Direction mplsXCExtEntry ...................25
9.3.8. Reverse-Direction mplsXCExtEntry ...................25
10. MPLS Textual Convention Extension MIB Definitions .............26
11. MPLS Identifier MIB Definitions ...............................29
12. MPLS LSR Extension MIB Definitions ............................34
13. MPLS Tunnel Extension MIB Definitions .........................39
14. Security Considerations .......................................57
15. IANA Considerations ...........................................58
15.1. IANA Considerations for MPLS-TC-EXT-STD-MIB ..............58
15.2. IANA Considerations for MPLS-ID-STD-MIB ..................58
15.3. IANA Considerations for MPLS-LSR-EXT-STD-MIB .............58
15.4. IANA Considerations for MPLS-TE-EXT-STD-MIB ..............59
16. References ....................................................59
16.1. Normative References .....................................59
16.2. Informative References ...................................60
Acknowledgments ...................................................62
Authors' Addresses ................................................62
1. Introduction β¨
okay so this memo defines another piece of the MIB, for network management protocols in the Internet community π the specific focus is additional textual conventions and managed objects for tunnels, identifiers, and Label Switching Routers. the goal is to support MPLS MIB modules for transport networks π
the MIB modules here extend the existing MPLS MIB objects so they support the MPLS Transport Profile (MPLS-TP) but also other MPLS networks too π that's why "MPLS-TP" isn't in the MIB module names. it's all about inclusivity, bestie π«Ά
quick refresher: the MPLS TE MIB definition [RFC3812] is all about making and managing MPLS tunnels π¦ a tunnel is shorthand for one or more LSPs linking an ingress LSR and an egress LSR. between a pair of LSRs A and B, you can build a few types of point-to-point MPLS tunnels:
- Unidirectional with a single LSP (say, from A to B) πΈ
- Associated bidirectional, which is two separately routed LSPs: one links A to B and the other links B to A. together they give you a single logical bidirectional transport path π
- Co-routed bidirectional, which is an associated bidirectional tunnel but the second LSP runs from B to A along the reverse of the A-to-B path, matching both nodes and links π₯
tunnels can be statically configured by management action, or dynamically created with an LSP management protocol β¨
here's the tea π΅ the existing MPLS TE MIB [RFC3812] and the GMPLS TE MIB [RFC4802] only cover some of the combos of static and dynamic tunnel types. they handle statically configured unidirectional tunnels, plus dynamically configured unidirectional and co-routed bidirectional tunnels. they're also limited to two endpoint LSRs identified by IP addresses π
so the MPLS-TP TE MIB in this doc extends the modules in [RFC3812] to cover all six combinations π that means adding support for statically configured associated and co-routed bidirectional tunnels, plus dynamically configured associated bidirectional tunnels. it also reaches endpoints with identifiers that aren't IP addresses π§
this support comes from a suite of four MIB modules. they're meant to work alongside the MIB modules in [RFC3812] and the companion document [RFC3813] for MPLS-TP tunnel management π
one more thing, and it's important π SNMP SET is no longer recommended as a way to configure MPLS networks, as described in [RFC3812]. but since the MIB modules here extend [RFC3812] and are meant to work in parallel with it, some objects are specified with MAX-ACCESS of read-write or read-create. that way the base tables in [RFC3812] and the extensions in this doc stay consistent π«Ά the examples in Section 9 show how to configure MPLS-TP tunnels in a similar way to the examples in [RFC3812]. but treat them as showing what the MIB values would return if those circumstances were configured by other means, not as a recommended way to configure them πΈ
2. The Internet-Standard Management Framework β¨
for a full overview of the docs describing the current Internet-Standard Management Framework, check out section 7 of RFC 3410 [RFC3410] π
managed objects are accessed through a virtual information store called the Management Information Base, or MIB π MIB objects are generally accessed through the Simple Network Management Protocol (SNMP). objects in the MIB are defined using the mechanisms in the Structure of Management Information (SMI). this memo specifies a MIB module that complies with SMIv2, which is described in STD 58, RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580 [RFC2580] π¦
3. Overview π
3.1. Conventions Used in This Document π₯
okay bestie, this part is the key-words rule book π the key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in [RFC2119] π
3.2. Terminology π
okay so this doc borrows its terms from a few other RFCs bestie: "Multiprotocol Label Switching Architecture" [RFC3031], "Multiprotocol Label Switching (MPLS) Traffic Engineering (TE) Management Information Base (MIB)" [RFC3812], "Multiprotocol Label Switching (MPLS) Label Switching Router (LSR) Management Information Base (MIB)" [RFC3813], and "MPLS Transport Profile (MPLS-TP) Identifiers" [RFC6370]. β¨
3.3. Acronyms π€
CC: Country Code
ICC: ITU Carrier Code
LSP: Label Switched Path
LSR: Label Switching Router
MPLS-TP: MPLS Transport Profile
TE: Traffic Engineering
TP: Transport Profile
4. Motivations π
okay so "Multiprotocol Label Switching (MPLS) Traffic Engineering (TE) Management Information Base (MIB)" [RFC3812] is the one that gives us support for Traffic Engineering tunnels π. In MPLS, the actual transport of packets is handled by Label Switched Paths (LSPs). A transport service can be made up of multiple LSPs. To clearly name the MPLS-TP service (as defined in [RFC6370]), we use the term "MPLS-TP Tunnel" or just "tunnel". π
But here's the tea: with MPLS-TP, tunnels got upgraded. For example, MPLS-TP Tunnels are bidirectional in nature and can be used with non-IP identifiers for the tunnel endpoints π¦. The existing MPLS-TE-STD-MIB and GMPLS-TE-STD-MIB were mainly built for unidirectional tunnels and signaled co-routed bidirectional tunnel definitions, respectively. So these existing MIB modules aren't enough to capture all the characteristics of the tunnels π. That means enhancing the MIB modules to support MPLS-TP Tunnels is required. Since most of the attributes of MPLS Traffic Engineering tunnels also apply to MPLS-TP Tunnels, it is optimal to reuse and extend the existing MIB module definition instead of creating a brand-new MIB module π§ β¨.
This document defines four additional MIB modules: MPLS-TE-EXT-STD-MIB, MPLS-TC-EXT-STD-MIB, MPLS-ID-STD-MIB, and MPLS-LSR-EXT-STD-MIB. These additional MIB modules are required for MPLS-TP functionality, so they're all defined right here instead of being documented separately π«Ά.
5. Feature List πΈ
The MIBs in this document satisfy the following requirements and constraints π :
The MIB modules, taken together, support statically configured and dynamically signaled point-to-point, co-routed bidirectional and associated bidirectional tunnels π.
- The MPLS tunnels need not be interfaces, but it is possible to configure an MPLS-TP Tunnel as an interface. The same ifType 150, as defined in Section 8 of [RFC3812], will be used for MPLS-TP Tunnels as well.
- The mplsTunnelTable [RFC3812] is also to be used for MPLS-TP Tunnels.
- New MPLS-TP-specific textual conventions and identifiers are required.
- The mplsTunnelTable is sparsely extended to support objects specific to MPLS-TP Tunnels.
- A node configuration table (mplsTunnelExtNodeConfigTable), as detailed in Section 6.2.1, below, is used to translate the Global_ID::Node_ID or ICC_Operator_ID::Node_ID to the local identifier in order to index the mplsTunnelTable ποΈ.
- The mplsXCTable is sparsely extended to support objects specific to MPLS-TP XC (Cross Connect).
- The MIB module supports persistent, as well as non-persistent, tunnels π.
6. Outline πΊοΈ
Traffic Engineering support for the MPLS-TP Tunnels requires the setup of the co-routed or associated bidirectional tunnel π. The tables and MIB modules mentioned in the subsections below support the functionality described in [RFC5654] and [RFC6370]. These tables support both IP-compatible and ICC-based tunnel configurations π§.
Figure 1 below shows how the table references are followed in this MIB, and it's honestly so pretty π¦:
Tunnel1-->XC1<--------------
^ ^ | | |
| | | |-->InSeg1 |
| | | |-->OutSeg1 |
| | v |
| ------XCext1 |
| | |
V v |
Tunnel2-->XC1 |
^ | | |
| | |-->InSeg2 |
| | |-->OutSeg2 |
| v |
------XCext2------------
Figure 1: Table References of MIB Modules
6.1. MIB Module Extensions π§©
Four MIB modules are extended to support MPLS-TP Tunnels: MPLS-TE-EXT-STD-MIB, MPLS-TC-EXT-STD-MIB, MPLS-ID-STD-MIB, and MPLS-LSR-EXT-STD-MIB. The following section gives you the summary of changes π.
6.1.1. Summary of MIB Module Changes π
- Node configuration table (mplsTunnelExtNodeConfigTable) for setting the local identifier for Tunnel Ingress and Egress identifiers.
- Node IP map table (mplsTunnelExtNodeIpMapTable) for querying the local identifier for a given Global_ID and Node_ID.
- Node ICC map table (mplsTunnelExtNodeIccMapTable) for querying the local identifier for a given ICC_Operator_ID and Node_ID.
- Tunnel extension table (mplsTunnelExtTable) for setting up MPLS-TP Tunnels with sparse extension of mplsTunnelTable.
- Textual conventions and object definitions for MPLS-TP Tunnels.
- Cross-connect extension table (mplsXCExtTable) for setting up the MPLS-TP LSPs.
These tables are described in the subsequent sections π.
6.2. MPLS-TE-EXT-STD-MIB π·
The TE MIB module extensions and details of the tables are described in the following sections.
6.2.1. mplsTunnelExtNodeConfigTable π
The mplsTunnelExtNodeConfigTable is used to assign a local identifier for a given ICC_Operator_ID::Node_ID or Global_ID::Node_ID combination, as defined in [RFC6923] and [RFC6370], respectively. The CC is a string of two characters, each being an uppercase Basic Latin alphabetic (i.e., A-Z). The ICC is a string of one to six characters, each an uppercase Basic Latin alphabetic (i.e., A-Z) or numeric (i.e., 0-9). All of the characters are encoded using [T.50], as described in [RFC6370] π .
In the IP-compatible mode, Global_ID::Node_ID is used to uniquely identify a node πͺͺ. For each ICC_Operator_ID::Node_ID or Global_ID::Node_ID, there is a unique entry in the table representing a node. Since the regular TE tunnels use the IP address as the LSR ID, the local identifier should be below the first valid IP address, which is 16777216[1.0.0.0]. Every node is assigned a local identifier within a range of 0 to 16777215. This local identifier is used for indexing into mplsTunnelTable as mplsTunnelIngressLSRId and mplsTunnelEgressLSRId π .
For IP-compatible environments, an MPLS-TP Tunnel is indexed by Tunnel Index, Tunnel Instance, Source Global_ID, Source Node_ID, Destination Global_ID, and Destination Node_ID.
For ICC-based environments, an MPLS-TP Tunnel is indexed by Tunnel Index, Tunnel Instance, Source CC, Source ICC, Source Node_ID, Destination CC, Destination ICC, and Destination Node_ID.
Because mplsTunnelTable is indexed by mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, and mplsTunnelEgressLSRId, the MPLS-TP tunnel identifiers cannot be used directly π.
The mplsTunnelExtNodeConfigTable will be used to store an entry for ICC_Operator_ID::Node_ID or Global_ID::Node_ID, with a local identifier to be used as the LSR ID in mplsTunnelTable π.
6.2.2. mplsTunnelExtNodeIpMapTable πΊοΈ
The read-only mplsTunnelExtNodeIpMapTable is used to query the local identifier assigned and stored in mplsTunnelExtNodeConfigTable for a given Global_ID::Node_ID. To query the local identifier in the IP-compatible mode, this table is indexed with Global_ID::Node_ID. In the IP-compatible mode for a TP tunnel, Global_ID::Node_ID is used.
A separate query is made to get the local identifier of both Ingress and Egress Global_ID::Node_ID identifiers. These local identifiers are used as mplsTunnelIngressLSRId and mplsTunnelEgressLSRId when indexing mplsTunnelTable π«Ά.
6.2.3. mplsTunnelExtNodeIccMapTable π
The read-only mplsTunnelExtNodeIccMapTable is used to query the local identifier assigned and stored in the mplsTunnelExtNodeConfigTable for a given ICC_Operator_ID::Node_ID.
A separate query is made to get the local identifier of both Ingress and Egress ICC_Operator_ID::Node_ID. These local identifiers are used as mplsTunnelIngressLSRId and mplsTunnelEgressLSRId when indexing mplsTunnelTable π§ββοΈ.
6.2.4. mplsTunnelExtTable β
This table sparsely extends the mplsTunnelTable to support MPLS-TP Tunnels with additional objects. All the additional attributes specific to supporting a TP tunnel are contained in this extended table and can be accessed with the mplsTunnelTable indices π.
The gmplsTunnelReversePerfTable [RFC4802] should be used to provide per-tunnel packet performance information for the reverse direction of a bidirectional tunnel. It can be seen as supplementing the mplsTunnelPerfTable, which augments the mplsTunnelTable π.
6.3. MPLS-TC-EXT-STD-MIB π§
This MIB module contains textual conventions for LSPs of MPLS-based transport networks.
6.4. MPLS-ID-STD-MIB πͺ
This MIB module contains identifier object definitions for MPLS Traffic Engineering in transport networks.
6.5. MPLS-LSR-EXT-STD-MIB π°οΈ
This MIB module contains generic object definitions (including the mplsXCExtTable -- cross-connect extension table -- for setting up the MPLS-TP LSPs with sparse extension of mplsXCTable) for MPLS LSRs in transport networks.
6.6. The Use of RowPointer π
This document follows the RowPointer usage as described in Section 10 of [RFC3812].
A new RowPointer object, mplsTunnelExtOppositeDirPtr, is added to mplsTunnelExtTable of the MPLS-TE-EXT-STD-MIB module. This RowPointer object points to the tunnel entry in the opposite direction β©οΈ.
Two additional RowPointer objects, mplsXCExtTunnelPointer and mplsXCExtOppositeDirXCPtr, are added to the mplsXCExtTable of MPLS-LSR-EXT-STD-MIB. The RowPointer mplsXCExtTunnelPointer is a read-only object used to indicate the back pointer to the tunnel entry. The RowPointer mplsXCExtOppositeDirXCPtr object points to the opposite-direction XC entry πͺ.
If either of these RowPointers returns zeroDotZero, it implies that there is no entry associated with the RowPointer object π.
7. MIB Modules' Interdependencies π§
okay so this section is basically the map of how the MPLS-TP TE MIB module hangs out with the other MPLS MIB modules πΊοΈβ¨ it's giving connected web energy, bestie π
the arrows in the diagram below mean "depends on" πΉ and "MIB module A depends on MIB module B" means that module A uses an object, object identifier, or textual convention from module B, OR module A has a pointer (an index or a RowPointer) to an object in module B π«Ά
MPLS-TC-EXT-STD-MIB
^
|
|
+<---- MPLS-ID-STD-MIB
^
| |
+<---- MPLS-TE-EXT-STD-MIB
| |
| V
| MPLS-TE-STD-MIB
| |
| |
| V
| MPLS-LSR-STD-MIB
| ^
| |
| |
+------MPLS-LSR-EXT-STD-MIB
Figure 2: MIB Modules' Interdependencies π¦
So basically, the vibes are:
- all the new MPLS extension MIB modules depend on
MPLS-TC-EXT-STD-MIBπ MPLS-ID-STD-MIBhas references to objects in MPLS-TE-STD-MIB [RFC3812] πΈMPLS-TE-EXT-STD-MIBhas references to objects in MPLS-TE-STD-MIB [RFC3812] πMPLS-LSR-EXT-STD-MIBhas references to objects in MPLS-LSR-STD-MIB [RFC3813] π
The mplsTunnelExtTable sparsely extends the mplsTunnelTable of MPLS-TE-STD-MIB [RFC3812] β¨ and this is what helps link up the reverse-direction tunnel info, iykyk π
The mplsXCExtTable sparsely extends the mplsXCTable of MPLS-LSR-STD-MIB [RFC3813] π¦ and it's the thing that points back to the tunnel entry, so you can get to the tunnel super fast from the XC entry πββοΈπ¨
ngl, the one everyone forgets: ALL of the MIB modules in the figure also have a dependency on MPLS-TC-STD-MIB π¨ don't skip it, periodt!
8. Dependencies between MIB Module Tables π
okay the tables inside MPLS-TE-EXT-STD-MIB are related like this π§© the arrows mean "a reference from one table to another" so follow them like breadcrumbs πβ¨
mplsTunnelExtNodeConfigTable
^ ^ ^
| | |
| | |
| | |
| | +----------------------+
| | |
| mplsTunnelExtNodeIpMapTable mplsTunnelExtNodeIccMapTable
|
| mplsXCExtTable
| | ^
| +---------+ |
| | |
| | |
| V V
mplsTunnelTable ---->mplsXCTable
^
|
|
|
mplsTunnelExtTable
Figure 3: Dependencies between MIB Module Tables π
here's the tea β:
- an existing
mplsTunnelTableuses themplsTunnelExtNodeConfigTableto map the Global_ID::Node_ID and/or ICC_Operator_ID::Node_ID to the local number, so the existing tunnel table's ingress/egress LSR ID can work with it π«Ά - the new
mplsTunnelExtTablegives the reverse-direction LSP info for the existing tunnel table, so bidirectional LSPs can be created ππ - the
mplsXCExtTablesparsely extends themplsLsrXCTableto give a backward reference to the tunnel entry πβ¨
9. Example of MPLS-TP Tunnel Setup π
okay now the fun part, the walkthrough π₯Ή this section shows how to set up MPLS-TP bidirectional tunnels that use IP tunnel identifiers π¦ it's the usage of the MPLS-TP Tunnel MIB together with the extended MIB modules from this document, so it's giving full set-up energy π
do note that an MPLS-TP Tunnel could be set up statically OR signaled via the control plane π°οΈ this example looks at accessing MIB objects on a head-end for both static and signaled MPLS-TP Tunnels π it shows the config of the forward- and reverse-direction MPLS-TP LSPs that run between East and West, and vice versa π§ only the objects relevant to MPLS-TP Tunnels are shown here, no extra drama π ββοΈ
first up, mplsTunnelExtNodeConfigTable π§
{
-- Non-IP Ingress LSR_ID (Index to the table)
mplsTunnelExtNodeConfigLocalId = 1,
mplsTunnelExtNodeConfigGlobalId = 1234,
mplsTunnelExtNodeConfigNodeId = 10,
-- Mandatory parameters needed to activate the row go here
mplsTunnelExtNodeConfigRowStatus = createAndGo (4)
-- Non-IP Egress LSR ID (Index to the table)
mplsTunnelExtNodeConfigLocalId = 2,
mplsTunnelExtNodeConfigGlobalId = 1234,
mplsTunnelExtNodeConfigNodeId = 20,
-- Mandatory parameters needed to activate the row go here
mplsTunnelExtNodeConfigRowStatus = createAndGo (4)
}
this creates an entry in the mplsTunnelExtNodeConfigTable for a Global_ID::Node_ID π the Ingress and Egress LSR each get their own separate entry π―ββοΈ
the read-only mplsTunnelExtNodeIpMapTable gets populated automatically once you create an entry in mplsTunnelExtNodeConfigTable β‘ and this table is what you use to retrieve the local identifier for a given Global_ID::Node_ID π
in mplsTunnelExtNodeIpMapTable:
{
-- Global_ID (Index to the table)
mplsTunnelExtNodeIpMapGlobalId = 1234,
-- Node Identifier (Index to the table)
mplsTunnelExtNodeIpMapNodeId = 10,
mplsTunnelExtNodeIpMapLocalId = 1
-- Global_ID (Index to the table)
mplsTunnelExtNodeIpMapGlobalId = 1234,
-- Node Identifier (Index to the table)
mplsTunnelExtNodeIpMapNodeId = 20,
mplsTunnelExtNodeIpMapLocalId = 2
}
9.1. Example of MPLS-TP Static Co-routed Bidirectional Tunnel Setup πΈ
this is the "head" entry for the co-routed bidirectional tunnel π¦
9.1.1. mplsTunnelEntry π
in mplsTunnelTable:
{
mplsTunnelIndex = 1,
mplsTunnelInstance = 1,
-- Local map number created in mplsTunnelExtNodeConfigTable for
-- Ingress LSR ID
mplsTunnelIngressLSRId = 1,
-- Local map number created in mplsTunnelExtNodeConfigTable for
-- Egress LSR ID
mplsTunnelEgressLSRId = 2,
mplsTunnelName = "TP co-routed bidirectional LSP",
mplsTunnelDescr = "East to West",
mplsTunnelIsIf = true (1),
-- RowPointer MUST point to the first accessible column
mplsTunnelXCPointer =
mplsXCLspId.4.0.0.0.1.1.0.4.0.0.0.1,
mplsTunnelSignallingProto = none (1),
mplsTunnelSetupPrio = 0,
mplsTunnelHoldingPrio = 0,
mplsTunnelSessionAttributes = 0,
mplsTunnelLocalProtectInUse = false (0),
-- RowPointer MUST point to the first accessible column
mplsTunnelResourcePointer = mplsTunnelResourceMaxRate.5,
mplsTunnelInstancePriority = 1,
mplsTunnelHopTableIndex = 1,
mplsTunnelIncludeAnyAffinity = 0,
mplsTunnelIncludeAllAffinity = 0,
mplsTunnelExcludeAnyAffinity = 0,
mplsTunnelRole = head (1),
-- Mandatory parameters needed to activate the row go here
mplsTunnelRowStatus = createAndGo (4)
}
9.1.2. mplsTunnelExtEntry π
-- An MPLS extension table
In mplsTunnelExtTable:
{
-- This opposite-direction tunnel pointer may point to 0.0
-- if co-routed bidirectional tunnel is managed by single tunnel
-- entry
mplsTunnelExtOppositeDirTnlPtr = 0.0
-- Set both the Ingress and Egress LocalId objects to TRUE, as
-- this tunnel entry uses the local identifiers.
mplsTunnelExtIngressLSRLocalIdValid = true,
mplsTunnelExtEgressLSRLocalIdValid = true
}
next up, we have to create the right in-segment and out-segment entries π§© these are done in [RFC3813] using the mplsInSegmentTable and mplsOutSegmentTable β¨
9.1.3. Forward-Direction mplsOutSegmentEntry π
for the forward direction:
In mplsOutSegmentTable:
{
mplsOutSegmentIndex = 0x0000001,
mplsOutSegmentInterface = 13, -- outgoing interface
mplsOutSegmentPushTopLabel = true(1),
mplsOutSegmentTopLabel = 22, -- outgoing label
-- RowPointer MUST point to the first accessible column.
mplsOutSegmentTrafficParamPtr = 0.0,
mplsOutSegmentRowStatus = createAndGo (4)
}
9.1.4. Reverse-Direction mplsInSegmentEntry π
for the reverse direction:
In mplsInSegmentTable:
{
mplsInSegmentIndex = 0x0000001
mplsInSegmentLabel = 21, -- incoming label
mplsInSegmentNPop = 1,
mplsInSegmentInterface = 13, -- incoming interface
-- RowPointer MUST point to the first accessible column.
mplsInSegmentTrafficParamPtr = 0.0,
mplsInSegmentRowStatus = createAndGo (4)
}
next, two cross-connect entries get created in the mplsXCTable of the MPLS-LSR-STD-MIB [RFC3813] π and they tie the newly created segments together π
9.1.5. Forward-Direction mplsXCEntry π
in mplsXCTable:
{
mplsXCIndex = 0x01,
mplsXCInSegmentIndex = 0x00000000,
mplsXCOutSegmentIndex = 0x00000001,
mplsXCLspId = 0x0102 -- unique ID
-- only a single outgoing label
mplsXCLabelStackIndex = 0x00,
mplsXCRowStatus = createAndGo(4)
}
9.1.6. Reverse-Direction mplsXCEntry π
in mplsXCTable:
{
mplsXCIndex = 0x01,
mplsXCInSegmentIndex = 0x00000001,
mplsXCOutSegmentIndex = 0x00000000,
mplsXCLspId = 0x0102 -- unique ID
-- only a single outgoing label
mplsXCLabelStackIndex = 0x00,
mplsXCRowStatus = createAndGo(4)
}
this table entry gets extended by an entry in the mplsXCExtTable π§ the 'extends' relationship is a sparse augmentation, so the entry in the mplsXCExtTable has the same index values as the entry in the mplsXCTable πͺ
9.1.7. Forward-Direction mplsXCExtEntry π¦
in mplsXCExtTable (0x01, 0x00000000, 0x00000001):
{
-- Back pointer from XC table to Tunnel table
mplsXCExtTunnelPointer = mplsTunnelName.1.1.1.2
mplsXCExtOppositeDirXCPtr =
mplsXCLspId.4.0.0.0.1.4.0.0.0.1.1.0
}
9.1.8. Reverse-Direction mplsXCExtEntry π«Ά
next, for the reverse direction:
in mplsXCExtTable (0x01, 0x00000001, 0x00000000):
{
-- Back pointer from XC table to Tunnel table
mplsXCExtTunnelPointer = mplsTunnelName.1.1.1.2
mplsXCExtOppositeDirXCPtr =
mplsXCLspId.4.0.0.0.1.1.0.4.0.0.0.1
}
9.2. Example of MPLS-TP Static Associated Bidirectional Tunnel Setup β¨
the MPLS-TP associated bidirectional tunnel is built from two different unidirectional tunnels (a forward LSP and a reverse LSP) π€οΈ and these get associated together using mplsTunnelExtTable π two different tunnel entries for the forward and reverse directions MAY be used for co-routed bidirectional tunnels as well π
the following is the "head" entry for the associated bidirectional forward tunnel π¦
9.2.1. Forward-Direction mplsTunnelEntry β¨
okay so this is the forward tunnel entry, aka the bestie of the head end π It's a row in mplsTunnelTable:
In mplsTunnelTable:
{
mplsTunnelIndex = 1,
mplsTunnelInstance = 1,
-- Local map number created in mplsTunnelExtNodeConfigTable for
-- Ingress LSR ID
mplsTunnelIngressLSRId = 1,
-- Local map number created in mplsTunnelExtNodeConfigTable for
-- Egress LSR ID
mplsTunnelEgressLSRId = 2,
mplsTunnelName = "TP associated bidirectional
forward LSP",
mplsTunnelDescr = "East to West",
mplsTunnelIsIf = true (1),
-- RowPointer MUST point to the first accessible column
mplsTunnelXCPointer =
mplsXCLspId.4.0.0.0.1.1.0.4.0.0.0.1,
mplsTunnelSignallingProto = none (1),
mplsTunnelSetupPrio = 0,
mplsTunnelHoldingPrio = 0,
mplsTunnelSessionAttributes = 0,
mplsTunnelLocalProtectInUse = false (0),
-- RowPointer MUST point to the first accessible column
mplsTunnelResourcePointer = mplsTunnelResourceMaxRate.5,
mplsTunnelInstancePriority = 1,
mplsTunnelHopTableIndex = 1,
mplsTunnelIncludeAnyAffinity = 0,
mplsTunnelIncludeAllAffinity = 0,
mplsTunnelExcludeAnyAffinity = 0,
mplsTunnelRole = head (1),
-- Mandatory parameters needed to activate the row go here
mplsTunnelRowStatus = createAndGo (4)
}
9.2.2. Forward-Direction mplsTunnelExtEntry π
Next up, the extension row for that same forward LSP, in mplsTunnelExtTable:
For the associated bidirectional forward LSP,
in mplsTunnelExtTable:
{
mplsTunnelExtOppositeDirPtr = mplsTunnelName.2.1.2.1
-- Set both the Ingress and Egress LocalId objects to TRUE, as
-- this tunnel entry uses the local identifiers.
mplsTunnelExtIngressLSRLocalIdValid = true,
mplsTunnelExtEgressLSRLocalIdValid = true
}
9.2.3. Forward-Direction mplsOutSegmentTable π¦
For the forward direction, we're setting up the out-segment row in mplsOutSegmentTable:
For the forward direction:
In mplsOutSegmentTable:
{
mplsOutSegmentIndex = 0x0000001,
mplsOutSegmentInterface = 13, -- outgoing interface
mplsOutSegmentPushTopLabel = true(1),
mplsOutSegmentTopLabel = 22, -- outgoing label
-- RowPointer MUST point to the first accessible column.
mplsOutSegmentTrafficParamPtr = 0.0,
mplsOutSegmentRowStatus = createAndGo (4)
}
9.2.4. Forward-Direction mplsXCEntry πΈ
Now the cross-connect row in mplsXCTable, which ties things together:
In mplsXCTable:
{
mplsXCIndex = 0x01,
mplsXCInSegmentIndex = 0x00000000,
mplsXCOutSegmentIndex = 0x00000001,
mplsXCLspId = 0x0102 -- unique ID
-- only a single outgoing label
mplsXCLabelStackIndex = 0x00,
mplsXCRowStatus = createAndGo(4)
}
9.2.5. Forward-Direction mplsXCExtEntry π§
And the extension for that cross-connect, in mplsXCExtTable. The indexes here are (0x01, 0x00000000, 0x00000001):
In mplsXCExtTable (0x01, 0x00000000, 0x00000001)
{
-- Back pointer from XC table to Tunnel table
mplsXCExtTunnelPointer = mplsTunnelName.1.1.1.2
mplsXCExtOppositeDirXCPtr =
mplsXCLspId.4.0.0.0.1.4.0.0.0.1.1.0
}
9.2.6. Reverse-Direction mplsTunnelEntry π₯
Time for the other side! This is the configured associated bidirectional reverse tunnel "tail" entry, so the return trip gets its own row:
In mplsTunnelTable:
{
mplsTunnelIndex = 2,
mplsTunnelInstance = 1,
-- Local map number created in mplsTunnelExtNodeConfigTable for
-- Ingress LSR ID
mplsTunnelIngressLSRId = 2,
-- Local map number created in mplsTunnelExtNodeConfigTable for
-- Egress LSR ID
mplsTunnelEgressLSRId = 1,
mplsTunnelName = "TP associated bidirectional
reverse LSP",
mplsTunnelDescr = "West to East",
mplsTunnelIsIf = true (1),
-- RowPointer MUST point to the first accessible column
mplsTunnelXCPointer =
mplsXCLspId.4.0.0.0.1.4.0.0.0.1.1.0,
mplsTunnelSignallingProto = none (1),
mplsTunnelSetupPrio = 0,
mplsTunnelHoldingPrio = 0,
mplsTunnelSessionAttributes = 0,
mplsTunnelLocalProtectInUse = false (0),
-- RowPointer MUST point to the first accessible column
mplsTunnelResourcePointer = mplsTunnelResourceMaxRate.5,
mplsTunnelInstancePriority = 1,
mplsTunnelHopTableIndex = 1,
mplsTunnelIncludeAnyAffinity = 0,
mplsTunnelIncludeAllAffinity = 0,
mplsTunnelExcludeAnyAffinity = 0,
mplsTunnelRole = head (1),
-- Mandatory parameters needed to activate the row go here
mplsTunnelRowStatus = createAndGo (4)
}
9.2.7. Reverse-Direction mplsTunnelExtEntry π
The extension row for the reverse LSP, in mplsTunnelExtTable:
For the associated bidirectional reverse LSP,
in mplsTunnelExtTable:
{
mplsTunnelExtOppositeDirPtr = mplsTunnelName.1.1.1.2
-- Set both the Ingress and Egress LocalId objects to TRUE, as
-- this tunnel entry uses the local identifiers.
mplsTunnelExtIngressLSRLocalIdValid = true,
mplsTunnelExtEgressLSRLocalIdValid = true
}
9.2.8. Reverse-Direction mplsInSegmentEntry π«Ά
Next, we must create the appropriate in-segment and out-segment entries. These are done in [RFC3813] using the mplsInSegmentTable and mplsOutSegmentTable.
In mplsInSegmentTable, the reverse in-segment row looks like this:
In mplsInSegmentTable:
{
mplsInSegmentIndex = 0x0000001
mplsInSegmentLabel = 21, -- incoming label
mplsInSegmentNPop = 1,
mplsInSegmentInterface = 13, -- incoming interface
-- RowPointer MUST point to the first accessible column.
mplsInSegmentTrafficParamPtr = 0.0,
mplsInSegmentRowStatus = createAndGo (4)
}
Next, two cross-connect entries are created in the mplsXCTable of the MPLS-LSR-STD-MIB [RFC3813], thereby associating the newly created segments together.
9.2.9. Reverse-Direction mplsXCEntry β
Here's the reverse cross-connect row in mplsXCTable:
In mplsXCTable:
{
mplsXCIndex = 0x01,
mplsXCInSegmentIndex = 0x00000001,
mplsXCOutSegmentIndex = 0x00000000,
mplsXCLspId = 0x0102 -- unique ID
-- only a single outgoing label
mplsXCLabelStackIndex = 0x00,
mplsXCRowStatus = createAndGo(4)
}
This table entry is extended by an entry in the mplsXCExtTable. Note that the nature of the 'extends' relationship is a sparse augmentation so that the entry in the mplsXCExtTable has the same index values as the entry in the mplsXCTable.
9.2.10. Reverse-Direction mplsXCExtEntry π
Last one for this example! For the reverse direction, in mplsXCExtTable (0x01, 0x00000001, 0x00000000):
In mplsXCExtTable (0x01, 0x00000001, 0x00000000)
{
-- Back pointer from XC table to Tunnel table
mplsXCExtTunnelPointer = mplsTunnelName.2.1.2.1
mplsXCExtOppositeDirXCPtr =
mplsXCLspId.4.0.0.0.1.1.0.4.0.0.0.1
}
9.3. Example of MPLS-TP Signaled Co-routed Bidirectional Tunnel Setup π
Okay, now we switch to the signaled version. The co-routed bidirectional tunnel "head" entry looks like this. Intermediate and tail-end nodes are different: their tunnel table and its associated tables are created by the local management subsystem (e.g., agent) once the MPLS-TP Tunnel is signaled successfully. For examples of signaled tunnel table configuration, check out [RFC3812] and [RFC4802].
9.3.1. mplsTunnelEntry π
In mplsTunnelTable:
{
mplsTunnelIndex = 1,
mplsTunnelInstance = 0,
-- Local map number created in mplsTunnelExtNodeConfigTable for
-- Ingress LSR-Id. For the intermediate and tail-end nodes,
-- the local management entity is expected to pick the first
-- available local identifier that is not used in mplsTunnelTable.
mplsTunnelIngressLSRId = 1,
-- Local map number created in mplsTunnelExtNodeConfigTable for
-- Egress LSR ID
mplsTunnelEgressLSRId = 2,
mplsTunnelName = "TP co-routed bidirectional LSP",
mplsTunnelDescr = "East to West",
mplsTunnelIsIf = true (1),
-- RowPointer MUST point to the first accessible column
mplsTunnelXCPointer =
mplsXCLspId.4.0.0.0.1.1.0.4.0.0.0.1,
mplsTunnelSignallingProto = none (1),
mplsTunnelSetupPrio = 0,
mplsTunnelHoldingPrio = 0,
mplsTunnelSessionAttributes = 0,
mplsTunnelLocalProtectInUse = false (0),
-- RowPointer MUST point to the first accessible column
mplsTunnelResourcePointer = mplsTunnelResourceMaxRate.5,
mplsTunnelInstancePriority = 1,
mplsTunnelHopTableIndex = 1,
mplsTunnelIncludeAnyAffinity = 0,
mplsTunnelIncludeAllAffinity = 0,
mplsTunnelExcludeAnyAffinity = 0,
mplsTunnelRole = head (1),
-- Mandatory parameters needed to activate the row go here
mplsTunnelRowStatus = createAndGo (4)
}
9.3.2. mplsTunnelExtEntry π
-- An MPLS extension table
In mplsTunnelExtTable:
{
-- This opposite-direction tunnel pointer may point to 0.0
-- if co-routed bidirectional tunnel is managed by a single
-- tunnel entry
mplsTunnelExtOppositeDirTnlPtr = 0.0
-- Set both the Ingress and Egress LocalId objects to TRUE, as
-- this tunnel entry uses the local identifiers.
mplsTunnelExtIngressLSRLocalIdValid = true,
mplsTunnelExtEgressLSRLocalIdValid = true
}
Next, we must create the appropriate in-segment and out-segment entries. These are done in [RFC3813] using the mplsInSegmentTable and mplsOutSegmentTable.
9.3.3. Forward-Direction mplsOutSegmentEntry π¦
The forward-direction mplsOutSegmentTable will be populated automatically based on the information received from the signaling protocol. No hands needed, the protocol does the work β¨
9.3.4. Reverse-Direction mplsInSegmentEntry π
The reverse-direction mplsOutSegmentTable will be populated automatically based on the information received from the signaling protocol.
Next, two cross-connect entries are created in the mplsXCTable of the MPLS-LSR-STD-MIB [RFC3813], thereby associating the newly created segments together.
9.3.5. Forward-Direction mplsXCEntry πΈ
The forward-direction mplsXCEntry will be populated as soon as the forward-path label information is available.
9.3.6. Reverse-Direction mplsXCEntry π§
The reverse-direction mplsXCEntry will be populated as soon as the reverse-path label information is available.
This table entry is extended by an entry in the mplsXCExtTable. Note that the nature of the 'extends' relationship is a sparse augmentation so that the entry in the mplsXCExtTable has the same index values as the entry in the mplsXCTable.
9.3.7. Forward-Direction mplsXCExtEntry π₯
Once the forward path information is negotiated using the signaling protocol, the forward-direction mplsXCExtEntry will be created for associating the opposite-direction XC entry and tunnel table entry.
9.3.8. Reverse-Direction mplsXCExtEntry π
Once the reverse path information is negotiated using the signaling protocol, the reverse-direction mplsXCExtEntry will be created for associating the opposite-direction XC entry and tunnel table entry. β¨
10. MPLS Textual Convention Extension MIB Definitions β¨
okay bestie, this is the MIB module where the textual conventions for LSPs in MPLS-based transport networks get defined π¦ the whole vibe is "here are the exact formats for the identifiers so everyone's on the same page" π
MPLS-TC-EXT-STD-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, Unsigned32
FROM SNMPv2-SMI -- RFC 2578
TEXTUAL-CONVENTION
FROM SNMPv2-TC -- RFC 2579
mplsStdMIB
FROM MPLS-TC-STD-MIB -- RFC 3811
;
mplsTcExtStdMIB MODULE-IDENTITY
LAST-UPDATED
"201502020000Z" -- February 2, 2015
ORGANIZATION
"Multiprotocol Label Switching (MPLS) Working Group"
CONTACT-INFO
"
Venkatesan Mahalingam
Dell Inc,
5450 Great America Parkway,
Santa Clara, CA 95054, USA
Email: venkat.mahalingams@gmail.com
Kannan KV Sampath
Redeem,
India
Email: kannankvs@gmail.com
Sam Aldrin
Huawei Technologies
2330 Central Express Way,
Santa Clara, CA 95051, USA
Email: aldrin.ietf@gmail.com
Thomas D. Nadeau
Email: tnadeau@lucidvision.com
"
DESCRIPTION
"This MIB module contains Textual Conventions for LSPs of MPLS-
based transport networks.
Copyright (c) 2015 IETF Trust and the persons identified as
authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with or
without modification, is permitted pursuant to, and subject to
the license terms contained in, the Simplified BSD License set
forth in Section 4.c of the IETF Trust's Legal Provisions
Relating to IETF Documents
(http://trustee.ietf.org/license-info)."
-- Revision history.
REVISION
"201502020000Z" -- February 2, 2015
DESCRIPTION
"MPLS Textual Convention Extensions"
::= { mplsStdMIB 17 }
MplsGlobalId ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This object contains the Textual Convention for an IP-based
operator-unique identifier (Global_ID). The Global_ID can
contain the 2-octet or 4-octet value of the operator's
Autonomous System Number (ASN).
When the Global_ID is derived from a 2-octet ASN,
the two high-order octets of this 4-octet identifier
MUST be set to zero (0x00). Further, ASN 0 is reserved.
The size of the Global_ID string MUST be zero if
the Global_ID is invalid.
Note that a Global_ID of zero is limited to entities
contained within a single operator and MUST NOT be used
across a Network-to-Network Interface (NNI). A non-zero
Global_ID MUST be derived from an ASN owned by
the operator."
REFERENCE
"MPLS Transport Profile (MPLS-TP) Identifiers, RFC 6370,
Section 3"
SYNTAX OCTET STRING (SIZE (4))
MplsCcId ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The CC (Country Code) is a string of two characters, each
being an uppercase Basic Latin alphabetic (i.e., A-Z).
The characters are encoded using ITU-T Recommendation T.50.
The size of the CC string MUST be zero if the CC identifier
is invalid."
REFERENCE
"MPLS-TP Identifiers Following ITU-T Conventions,
RFC 6923, Section 3.
International Reference Alphabet (IRA) (Formerly
International Alphabet No. 5 or IA5) - Information
technology - 7-bit coded character set for information
exchange, ITU-T Recommendation T.50, September 1992."
SYNTAX OCTET STRING (SIZE (0|2))
MplsIccId ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The ICC is a string of one to six characters, each
an uppercase Basic Latin alphabetic (i.e., A-Z) or
numeric (i.e., 0-9). The characters are encoded
using ITU-T Recommendation T.50. The size of
the ICC string MUST be zero if the ICC identifier
is invalid."
REFERENCE
"MPLS-TP Identifiers Following ITU-T Conventions,
RFC 6923, Section 3.
International Reference Alphabet (IRA) (Formerly
International Alphabet No. 5 or IA5) - Information
technology - 7-bit coded character set for information
exchange, ITU-T Recommendation T.50, September 1992."
SYNTAX OCTET STRING (SIZE (0|1..6))
MplsNodeId ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"The Node_ID is assigned within the scope of
the Global_ID/ICC_Operator_ID.
When IPv4 addresses are in use, the value of this object
can be derived from the LSR's IPv4 loopback address.
When IPv6 addresses are in use, the value of this object
can be a 32-bit value unique within the scope of
a Global_ID.
Note that, when IP reachability is not needed, the 32-bit
Node_ID is not required to have any association
with the IPv4 address space. The value of 0 indicates
an invalid Node_ID."
REFERENCE
"MPLS Transport Profile (MPLS-TP) Identifiers, RFC 6370,
Section 4"
SYNTAX Unsigned32 (0|1..4294967295)
-- MPLS-TC-EXT-STD-MIB module ends
END
11. MPLS Identifier MIB Definitions β¨
okay bestie, this is the identifier MIB π It's where the operator gets to hand out the four identity labels for MPLS-TP nodes: Global_ID, Node_ID, CC, and ICC. The module is called MPLS-ID-STD-MIB and it's a total main character π
MPLS-ID-STD-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE
FROM SNMPv2-SMI -- RFC 2578
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF -- RFC 2580
mplsStdMIB
FROM MPLS-TC-STD-MIB -- RFC 3811
MplsGlobalId, MplsCcId, MplsIccId, MplsNodeId
FROM MPLS-TC-EXT-STD-MIB
;
mplsIdStdMIB MODULE-IDENTITY
LAST-UPDATED
"201502020000Z" -- February 2, 2015
ORGANIZATION
"Multiprotocol Label Switching (MPLS) Working Group"
CONTACT-INFO
"
Venkatesan Mahalingam
Dell Inc,
5450 Great America Parkway,
Santa Clara, CA 95054, USA
Email: venkat.mahalingams@gmail.com
Kannan KV Sampath
Redeem,
India
Email: kannankvs@gmail.com
Sam Aldrin
Huawei Technologies
2330 Central Express Way,
Santa Clara, CA 95051, USA
Email: aldrin.ietf@gmail.com
Thomas D. Nadeau
Email: tnadeau@lucidvision.com
"
DESCRIPTION
"This MIB module contains identifier object definitions for
MPLS Traffic Engineering in transport networks.
Copyright (c) 2015 IETF Trust and the persons identified as
authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with or
without modification, is permitted pursuant to, and subject to
the license terms contained in, the Simplified BSD License set
forth in Section 4.c of the IETF Trust's Legal Provisions
Relating to IETF Documents
(http://trustee.ietf.org/license-info)."
-- Revision history.
REVISION
"201502020000Z" -- February 2, 2015
DESCRIPTION
"This MIB modules defines the MIB objects for MPLS-TP
identifiers"
::= { mplsStdMIB 18 }
-- notifications
mplsIdNotifications OBJECT IDENTIFIER ::= { mplsIdStdMIB 0 }
-- tables, scalars
mplsIdObjects OBJECT IDENTIFIER ::= { mplsIdStdMIB 1 }
-- conformance
mplsIdConformance OBJECT IDENTIFIER ::= { mplsIdStdMIB 2 }
-- MPLS common objects
mplsIdGlobalId OBJECT-TYPE
SYNTAX MplsGlobalId
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the operator or service provider to
assign a unique operator identifier, also called the MPLS-TP
Global_ID.
If this value is used in mplsTunnelExtNodeConfigGlobalId
for mapping Global_ID::Node_ID with the local identifier,
then this object value MUST NOT be changed."
::= { mplsIdObjects 1 }
mplsIdNodeId OBJECT-TYPE
SYNTAX MplsNodeId
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the operator or service provider to
assign a unique MPLS-TP Node_ID. The Node_ID is assigned
within the scope of the Global_ID/ICC_Operator_ID.
If this value is used in mplsTunnelExtNodeConfigNodeId
for mapping Global_ID::Node_ID with the local identifier,
then this object value SHOULD NOT be changed.
If this value is used in mplsTunnelExtNodeConfigNodeId
for mapping ICC_Operator_ID::Node_ID with the local
identifier, then this object value MUST NOT be changed."
::= { mplsIdObjects 2 }
mplsIdCc OBJECT-TYPE
SYNTAX MplsCcId
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the operator or service provider to
assign a Country Code (CC) to the node. Global
uniqueness of ICC is assured by concatenating the ICC
with a Country Code (CC).
If this value is used in mplsTunnelExtNodeConfigCcId
for mapping ICC_Operator_ID::Node_ID with the local
identifier, then this object value MUST NOT be changed."
REFERENCE
"MPLS-TP Identifiers Following ITU-T Conventions,
RFC 6923, Section 3"
::= { mplsIdObjects 3 }
mplsIdIcc OBJECT-TYPE
SYNTAX MplsIccId
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the operator or service provider to
assign a unique MPLS-TP ITU-T Carrier Code (ICC) to
the node. Together, the CC and the ICC form
the ICC_Operator_ID as CC::ICC.
If this value is used in mplsTunnelExtNodeConfigIccId
for mapping ICC_Operator_ID::Node_ID with the local
identifier, then this object value MUST NOT be changed."
REFERENCE
"MPLS-TP Identifiers Following ITU-T Conventions,
RFC 6923, Section 3"
::= { mplsIdObjects 4 }
-- Module compliance.
mplsIdCompliances
OBJECT IDENTIFIER ::= { mplsIdConformance 1 }
mplsIdGroups
OBJECT IDENTIFIER ::= { mplsIdConformance 2 }
-- Compliance requirement for fully compliant implementations.
mplsIdModuleFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for agents that provide full
support of the MPLS-ID-STD-MIB module."
MODULE -- this module
-- The mandatory group has to be implemented by all LSRs that
-- originate, terminate, or act as transit for MPLS-TP Tunnels.
GROUP mplsIdIpOperatorGroup
DESCRIPTION
"This group is mandatory for devices that support
IP-based identifier configuration."
GROUP mplsIdIccOperatorGroup
DESCRIPTION
"This group is mandatory for devices that support
ICC-based identifier configuration."
::= { mplsIdCompliances 1 }
-- Compliance requirement for read-only implementations.
mplsIdModuleReadOnlyCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for agents that only provide
read-only support for the MPLS-ID-STD-MIB module."
MODULE -- this module
GROUP mplsIdIpOperatorGroup
DESCRIPTION
"This group is mandatory for devices that support
IP-based identifier configuration."
GROUP mplsIdIccOperatorGroup
DESCRIPTION
"This group is mandatory for devices that support
ICC-based identifier configuration."
OBJECT mplsIdGlobalId
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsIdNodeId
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsIdCc
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsIdIcc
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { mplsIdCompliances 2 }
-- Units of conformance.
mplsIdIpOperatorGroup OBJECT-GROUP
OBJECTS { mplsIdGlobalId,
mplsIdNodeId
}
STATUS current
DESCRIPTION
"The objects in this group are optional for an
ICC-based node."
::= { mplsIdGroups 1 }
mplsIdIccOperatorGroup OBJECT-GROUP
OBJECTS { mplsIdNodeId,
mplsIdCc,
mplsIdIcc
}
STATUS current
DESCRIPTION
"The objects in this group are optional for an
IP-based node."
::= { mplsIdGroups 2 }
-- MPLS-ID-STD-MIB module ends
END
ngl the groups at the bottom are giving "pick your lane" energy π IP-based nodes get one set of identifiers, ICC-based nodes get the other, and the compliance blocks just say which set your device has to bring to the party π
12. MPLS LSR Extension MIB Definitions π
okay so this section is the MIB module for the LSR extension, MPLS-LSR-EXT-STD-MIB π¦ it sits on top of the LSR MIB from RFC 3813 and adds the MPLS-TP tunnel info bits. here's the whole thing:
MPLS-LSR-EXT-STD-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE
FROM SNMPv2-SMI -- RFC 2578
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF -- RFC 2580
mplsStdMIB
FROM MPLS-TC-STD-MIB -- RFC 3811
RowPointer
FROM SNMPv2-TC -- RFC 2579
mplsXCIndex, mplsXCInSegmentIndex, mplsXCOutSegmentIndex,
mplsInterfaceGroup, mplsInSegmentGroup, mplsOutSegmentGroup,
mplsXCGroup, mplsLsrNotificationGroup
FROM MPLS-LSR-STD-MIB; -- RFC 3813
mplsLsrExtStdMIB MODULE-IDENTITY
LAST-UPDATED
"201502020000Z" -- February 2, 2015
ORGANIZATION
"Multiprotocol Label Switching (MPLS) Working Group"
CONTACT-INFO
"
Venkatesan Mahalingam
Dell Inc,
5450 Great America Parkway,
Santa Clara, CA 95054, USA
Email: venkat.mahalingams@gmail.com
Kannan KV Sampath
Redeem,
India
Email: kannankvs@gmail.com
Sam Aldrin
Huawei Technologies
2330 Central Express Way,
Santa Clara, CA 95051, USA
Email: aldrin.ietf@gmail.com
Thomas D. Nadeau
Email: tnadeau@lucidvision.com
"
DESCRIPTION
"This MIB module contains generic object definitions for
MPLS LSRs in transport networks.
Copyright (c) 2015 IETF Trust and the persons identified as
authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with or
without modification, is permitted pursuant to, and subject to
the license terms contained in, the Simplified BSD License set
forth in Section 4.c of the IETF Trust's Legal Provisions
Relating to IETF Documents
(http://trustee.ietf.org/license-info)."
-- Revision history.
REVISION
"201502020000Z" -- February 2, 2015
DESCRIPTION
"MPLS LSR-specific MIB objects extension"
::= { mplsStdMIB 19 }
-- notifications
mplsLsrExtNotifications OBJECT IDENTIFIER ::= { mplsLsrExtStdMIB 0 }
-- tables, scalars
mplsLsrExtObjects OBJECT IDENTIFIER
::= { mplsLsrExtStdMIB 1 }
-- conformance
mplsLsrExtConformance OBJECT IDENTIFIER
::= { mplsLsrExtStdMIB 2 }
-- MPLS LSR common objects
mplsXCExtTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsXCExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table sparse augments the mplsXCTable of
MPLS-LSR-STD-MIB (RFC 3813) to provide MPLS-TP-specific
information about associated tunnel information"
REFERENCE
"Multiprotocol Label Switching (MPLS) Label Switching
Router (LSR) Management Information Base (MIB), RFC 3813."
::= { mplsLsrExtObjects 1 }
mplsXCExtEntry OBJECT-TYPE
SYNTAX MplsXCExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table sparsely extends the cross-connect
information represented by an entry in
the mplsXCTable in MPLS-LSR-STD-MIB (RFC 3813) through
a sparse augmentation. An entry can be created by
a network operator via SNMP SET commands or in
response to signaling protocol events."
REFERENCE
"Multiprotocol Label Switching (MPLS) Label Switching
Router (LSR) Management Information Base (MIB), RFC 3813."
INDEX { mplsXCIndex, mplsXCInSegmentIndex,
mplsXCOutSegmentIndex }
::= { mplsXCExtTable 1 }
MplsXCExtEntry ::= SEQUENCE {
mplsXCExtTunnelPointer RowPointer,
mplsXCExtOppositeDirXCPtr RowPointer
}
mplsXCExtTunnelPointer OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This read-only object indicates the back pointer to
the tunnel entry segment.
The only valid value for Tunnel Pointer is
mplsTunnelTable entry."
REFERENCE
"Multiprotocol Label Switching (MPLS) Label Switching
Router (LSR) Management Information Base (MIB), RFC 3813."
::= { mplsXCExtEntry 1 }
mplsXCExtOppositeDirXCPtr OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the pointer to the opposite-
direction XC entry. This object cannot be modified if
mplsXCRowStatus for the corresponding entry in the
mplsXCTable is active(1). If this pointer is not set or
removed, mplsXCOperStatus should be set to down(2)."
REFERENCE
"Multiprotocol Label Switching (MPLS) Label Switching
Router (LSR) Management Information Base (MIB), RFC 3813."
::= { mplsXCExtEntry 2 }
mplsLsrExtCompliances
OBJECT IDENTIFIER ::= { mplsLsrExtConformance 1 }
mplsLsrExtGroups
OBJECT IDENTIFIER ::= { mplsLsrExtConformance 2 }
-- Compliance requirement for fully compliant implementations.
mplsLsrExtModuleFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for agents that provide full support
for MPLS-LSR-EXT-STD-MIB.
The mandatory group has to be implemented by all LSRs
that originate, terminate, or act as transit for
TE-LSPs/tunnels.
In addition, depending on the type of tunnels supported,
other groups become mandatory as explained below."
MODULE MPLS-LSR-STD-MIB -- The MPLS-LSR-STD-MIB, RFC 3813
MANDATORY-GROUPS {
mplsInSegmentGroup,
mplsOutSegmentGroup,
mplsXCGroup,
mplsLsrNotificationGroup
}
MODULE -- this module
MANDATORY-GROUPS {
mplsXCExtGroup
}
::= { mplsLsrExtCompliances 1 }
-- Compliance requirement for implementations that provide
-- read-only access.
mplsLsrExtModuleReadOnlyCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance requirement for implementations that only
provide read-only support for MPLS-LSR-EXT-STD-MIB.
Such devices can then be monitored but cannot be
configured using this MIB module."
MODULE MPLS-LSR-STD-MIB
MANDATORY-GROUPS {
mplsInterfaceGroup,
mplsInSegmentGroup,
mplsOutSegmentGroup
}
MODULE -- this module
GROUP mplsXCExtReadOnlyObjectsGroup
DESCRIPTION
"This group is mandatory for devices that support
opposite-direction XC configuration of tunnels."
-- mplsXCExtTable
OBJECT mplsXCExtOppositeDirXCPtr
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required.
This object indicates the pointer to the opposite-
direction XC entry. The only valid value for XC
Pointer is mplsXCTable entry."
::= { mplsLsrExtCompliances 2 }
-- Units of conformance.
mplsXCExtGroup OBJECT-GROUP
OBJECTS {
mplsXCExtTunnelPointer,
mplsXCExtOppositeDirXCPtr
}
STATUS current
DESCRIPTION
"This object should be supported in order to access
the tunnel entry from the XC entry."
::= { mplsLsrExtGroups 1 }
mplsXCExtReadOnlyObjectsGroup OBJECT-GROUP
OBJECTS {
mplsXCExtTunnelPointer,
mplsXCExtOppositeDirXCPtr
}
STATUS current
DESCRIPTION
"This Object is needed to associate the opposite-direction
(forward/reverse) XC entry."
::= { mplsLsrExtGroups 2 }
-- MPLS-LSR-EXT-STD-MIB module ends
END
13. MPLS Tunnel Extension MIB Definitions β¨
this one is the MIB module for the MPLS TE tunnel extension, and it pulls stuff in from a whole crew of RFCs π§ it imports from [RFC2578], [RFC2579], [RFC2580], [RFC3289], [RFC3811], and [RFC3812]. slay the imports, lol π
MPLS-TE-EXT-STD-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE
FROM SNMPv2-SMI -- RFC 2578
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF -- RFC 2580
TruthValue, RowStatus, RowPointer, StorageType
FROM SNMPv2-TC -- RFC 2579
IndexIntegerNextFree
FROM DIFFSERV-MIB -- RFC 3289
MplsGlobalId, MplsNodeId, MplsCcId, MplsIccId
FROM MPLS-TC-EXT-STD-MIB
mplsStdMIB, MplsTunnelIndex, MplsTunnelInstanceIndex,
MplsExtendedTunnelId
FROM MPLS-TC-STD-MIB -- RFC 3811
mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId,
mplsTunnelEgressLSRId
FROM MPLS-TE-STD-MIB -- RFC 3812
;
mplsTeExtStdMIB MODULE-IDENTITY
LAST-UPDATED
"201502020000Z" -- February 2, 2015
ORGANIZATION
"Multiprotocol Label Switching (MPLS) Working Group"
CONTACT-INFO
"
Venkatesan Mahalingam
Dell Inc,
5450 Great America Parkway,
Santa Clara, CA 95054, USA
Email: venkat.mahalingams@gmail.com
Kannan KV Sampath
Redeem,
India
Email: kannankvs@gmail.com
Sam Aldrin
Huawei Technologies
2330 Central Express Way,
Santa Clara, CA 95051, USA
Email: aldrin.ietf@gmail.com
Thomas D. Nadeau
Email: tnadeau@lucidvision.com
"
DESCRIPTION
"This MIB module contains generic object definitions for
extending the MPLS Traffic Engineering tunnels in transport
networks.
Copyright (c) 2015 IETF Trust and the persons identified as
authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with or
without modification, is permitted pursuant to, and subject to
the license terms contained in, the Simplified BSD License set
forth in Section 4.c of the IETF Trust's Legal Provisions
Relating to IETF Documents
(http://trustee.ietf.org/license-info)."
-- Revision history.
REVISION
"201502020000Z" -- February 2, 2015
DESCRIPTION
"MPLS TE MIB objects extension"
::= { mplsStdMIB 20 }
-- Top-level components of this MIB module.
-- tables, scalars
mplsTeExtObjects OBJECT IDENTIFIER
::= { mplsTeExtStdMIB 0 }
-- conformance
mplsTeExtConformance OBJECT IDENTIFIER
::= { mplsTeExtStdMIB 1 }
-- Start of MPLS Transport Profile Node configuration table
mplsTunnelExtNodeConfigLocalIdNext OBJECT-TYPE
SYNTAX IndexIntegerNextFree (0..16777215)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an unused value for
mplsTunnelExtNodeConfigLocalId, or a zero to indicate
that none exist. Negative values are not allowed,
as they do not correspond to valid values of
mplsTunnelExtNodeConfigLocalId."
::= { mplsTeExtObjects 1 }
okay bestie, this is the part where we give our tunnel LSR IDs a glow-up πβ¨ The problem is that the tunnel table's Ingress and Egress LSR IDs are only 4-byte Unsigned32 values, but MPLS-TP node identifiers are way bigger: a Global_ID::Node_ID is 8 bytes and an ICC_Operator_ID::Node_ID is 12 bytes π So the fix is a little mapping table that squishes the big identifier down to a 4-byte local ID we can use as an index π
mplsTunnelExtNodeConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsTunnelExtNodeConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table allows the operator to map a node or
LSR identifier (IP-compatible [Global_ID::Node_ID] or
ICC-based [ICC_Operator_ID::Node_ID]) with a local
identifier.
This table is created to reuse the existing
mplsTunnelTable for MPLS-based transport network
tunnels also.
Since the MPLS tunnel's Ingress/Egress LSR identifiers'
size (Unsigned32) value is not compatible for
MPLS-TP Tunnel, i.e., Global_ID::Node_ID of size 8 bytes and
ICC_Operator_ID::Node_ID of size 12 bytes, there exists a
need to map the Global_ID::Node_ID or ICC_Operator_ID::Node_ID
with the local identifier of size 4 bytes (Unsigned32) value
in order to index (Ingress/Egress LSR identifier)
the existing mplsTunnelTable."
::= { mplsTeExtObjects 2 }
mplsTunnelExtNodeConfigEntry OBJECT-TYPE
SYNTAX MplsTunnelExtNodeConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a mapping
identification for the operator or service provider
to a node or an LSR.
As per RFC 6370, IP-compatible mapping is represented
as Global_ID::Node_ID.
As per RFC 6923, the CC and the ICC form the ICC_Operator_ID
as CC::ICC, and ICC-compatible mapping is represented
as ICC_Operator_ID::Node_ID.
Note: Each entry in this table should have a unique
[Global_ID and Node_ID] or [CC::ICC and Node_ID] combination."
INDEX { mplsTunnelExtNodeConfigLocalId }
::= { mplsTunnelExtNodeConfigTable 1 }
MplsTunnelExtNodeConfigEntry ::= SEQUENCE {
mplsTunnelExtNodeConfigLocalId MplsExtendedTunnelId,
mplsTunnelExtNodeConfigGlobalId MplsGlobalId,
mplsTunnelExtNodeConfigCcId MplsCcId,
mplsTunnelExtNodeConfigIccId MplsIccId,
mplsTunnelExtNodeConfigNodeId MplsNodeId,
mplsTunnelExtNodeConfigIccValid TruthValue,
mplsTunnelExtNodeConfigStorageType StorageType,
mplsTunnelExtNodeConfigRowStatus RowStatus
}
mplsTunnelExtNodeConfigLocalId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is used in accommodating the bigger-
size Global_ID::Node_ID and/or the ICC_Operator_ID::Node_ID
with the smaller-size LSR identifier in order to index
the mplsTunnelTable.
The local identifier is configured between 0 and 16777215,
as the valid IP address range starts from
16777216(01.00.00.00).
This range is chosen to determine whether the
mplsTunnelTable's Ingress/Egress LSR ID is an IP address or
local identifier. If the configured range is not an
IP address, the operator is expected to retrieve the
complete information (Global_ID::Node_ID or
ICC_Operator_ID::Node_ID) from mplsTunnelExtNodeConfigTable.
This way, the existing mplsTunnelTable is reused for
bidirectional tunnel extensions for MPLS-based transport
networks.
The local identifier allows the operator to assign
a unique identifier to map Global_ID::Node_ID and/or
ICC_Operator_ID::Node_ID. As this local identifier is unique
within the node and the same syntax of this object can be
used for MPLS-TE tunnel also, it is up to the operator/local
management entity to choose a non-conflicting value for
indexing the MPLS and MPLS-TP tunnel entries."
::= { mplsTunnelExtNodeConfigEntry 1 }
mplsTunnelExtNodeConfigGlobalId OBJECT-TYPE
SYNTAX MplsGlobalId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Global Operator Identifier.
This object has no meaning when
mplsTunnelExtNodeConfigIccValid is set true."
REFERENCE
"MPLS Transport Profile (MPLS-TP) Identifiers, RFC 6370,
Section 3."
::= { mplsTunnelExtNodeConfigEntry 2 }
mplsTunnelExtNodeConfigCcId OBJECT-TYPE
SYNTAX MplsCcId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows the operator or service provider to
configure a unique MPLS-TP ITU-T Country Code (CC)
either for Ingress ID or Egress ID.
This object has no meaning when
mplsTunnelExtNodeConfigIccValid is set to false."
REFERENCE
"MPLS-TP Identifiers Following ITU-T Conventions,
RFC 6923, Section 3"
::= { mplsTunnelExtNodeConfigEntry 3 }
mplsTunnelExtNodeConfigIccId OBJECT-TYPE
SYNTAX MplsIccId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows the operator or service provider to
configure a unique MPLS-TP ITU-T Carrier Code (ICC)
either for Ingress ID or Egress ID.
This object has no meaning when
mplsTunnelExtNodeConfigIccValid is set to false."
REFERENCE
"MPLS-TP Identifiers Following ITU-T Conventions,
RFC 6923, Section 3"
::= { mplsTunnelExtNodeConfigEntry 4 }
mplsTunnelExtNodeConfigNodeId OBJECT-TYPE
SYNTAX MplsNodeId
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Node_ID within the scope
of a Global_ID or ICC_Operator_ID."
REFERENCE
"MPLS Transport Profile (MPLS-TP) Identifiers, RFC 6370,
Section 4."
::= { mplsTunnelExtNodeConfigEntry 5 }
mplsTunnelExtNodeConfigIccValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes whether or not this entry uses
mplsTunnelExtNodeConfigCcId,
mplsTunnelExtNodeConfigIccId, and
mplsTunnelExtNodeConfigNodeId for mapping
the ICC-based identifiers with the local identifier.
Note that if this variable is set to false, then the
mplsTunnelExtNodeConfigGlobalId and
mplsTunnelExtNodeConfigNodeId objects should have
the valid information."
DEFVAL { false }
::= { mplsTunnelExtNodeConfigEntry 6 }
mplsTunnelExtNodeConfigStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable indicates the storage type for this
object.
Conceptual rows having the value 'permanent'
need not allow write-access to any columnar
objects in the row."
DEFVAL { volatile }
::= { mplsTunnelExtNodeConfigEntry 7 }
mplsTunnelExtNodeConfigRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows the operator to create, modify,
and/or delete a row in this table."
::= { mplsTunnelExtNodeConfigEntry 8 }
-- End of MPLS Transport Profile Node configuration table
-- Start of MPLS Transport Profile Node IP-compatible
-- mapping table
mplsTunnelExtNodeIpMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsTunnelExtNodeIpMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This read-only table allows the operator to retrieve
the local identifier for a given Global_ID::Node_ID in an
IP-compatible operator environment.
This table MAY be used in on-demand and/or proactive
OAM operations to get the Ingress/Egress LSR identifier
(local identifier) from Src-Global_Node_ID
or Dst-Global_Node_ID. The Ingress and Egress LSR
identifiers are used to retrieve the tunnel entry.
This table returns nothing when the associated entry
is not defined in mplsTunnelExtNodeConfigTable."
::= { mplsTeExtObjects 3 }
mplsTunnelExtNodeIpMapEntry OBJECT-TYPE
SYNTAX MplsTunnelExtNodeIpMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a mapping of
Global_ID::Node_ID with the local identifier.
An entry in this table is created automatically when
the local identifier is associated with Global_ID and
Node_Id in the mplsTunnelExtNodeConfigTable.
Note: Each entry in this table should have a unique
Global_ID and Node_ID combination."
INDEX { mplsTunnelExtNodeIpMapGlobalId,
mplsTunnelExtNodeIpMapNodeId
}
::= { mplsTunnelExtNodeIpMapTable 1 }
MplsTunnelExtNodeIpMapEntry ::= SEQUENCE {
mplsTunnelExtNodeIpMapGlobalId MplsGlobalId,
mplsTunnelExtNodeIpMapNodeId MplsNodeId,
mplsTunnelExtNodeIpMapLocalId MplsExtendedTunnelId
}
mplsTunnelExtNodeIpMapGlobalId OBJECT-TYPE
SYNTAX MplsGlobalId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Global_ID."
::= { mplsTunnelExtNodeIpMapEntry 1 }
mplsTunnelExtNodeIpMapNodeId OBJECT-TYPE
SYNTAX MplsNodeId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Node_ID within the
operator."
::= { mplsTunnelExtNodeIpMapEntry 2 }
mplsTunnelExtNodeIpMapLocalId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an IP-compatible local identifier
that is defined in mplsTunnelExtNodeConfigTable."
::= { mplsTunnelExtNodeIpMapEntry 3 }
-- End MPLS Transport Profile Node IP compatible table
-- Start of MPLS Transport Profile Node ICC based table
mplsTunnelExtNodeIccMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsTunnelExtNodeIccMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This read-only table allows the operator to retrieve
the local identifier for a given ICC_Operator_ID::Node_ID
in an ICC operator environment.
This table MAY be used in on-demand and/or proactive
OAM operations to get the Ingress/Egress LSR
identifier (local identifier) from Src-ICC
or Dst-ICC. The Ingress and Egress LSR
identifiers are used to retrieve the tunnel entry.
This table returns nothing when the associated entry
is not defined in mplsTunnelExtNodeConfigTable."
::= { mplsTeExtObjects 4 }
mplsTunnelExtNodeIccMapEntry OBJECT-TYPE
SYNTAX MplsTunnelExtNodeIccMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents a mapping of
ICC_Operator_ID::Node_ID with the local identifier.
An entry in this table is created automatically when
the local identifier is associated with
ICC_Operator_ID::Node_ID in
the mplsTunnelExtNodeConfigTable."
okay bestie, the ICC-based node table is up next π
INDEX { mplsTunnelExtNodeIccMapCcId,
mplsTunnelExtNodeIccMapIccId,
mplsTunnelExtNodeIccMapNodeId }
::= { mplsTunnelExtNodeIccMapTable 1 }
MplsTunnelExtNodeIccMapEntry ::= SEQUENCE {
mplsTunnelExtNodeIccMapCcId MplsCcId,
mplsTunnelExtNodeIccMapIccId MplsIccId,
mplsTunnelExtNodeIccMapNodeId MplsNodeId,
mplsTunnelExtNodeIccMapLocalId MplsExtendedTunnelId
}
mplsTunnelExtNodeIccMapCcId OBJECT-TYPE
SYNTAX MplsCcId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object allows the operator or service provider to
configure a unique MPLS-TP ITU-T Country Code (CC)
either for Ingress or Egress LSR ID.
The CC is a string of two alphabetic characters
represented with uppercase letters (i.e., A-Z)."
::= { mplsTunnelExtNodeIccMapEntry 1 }
mplsTunnelExtNodeIccMapIccId OBJECT-TYPE
SYNTAX MplsIccId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object allows the operator or service provider
to configure a unique MPLS-TP ITU-T Carrier
Code (ICC) either for Ingress or Egress LSR ID.
The ICC is a string of one to six characters, each
character being either alphabetic (i.e., A-Z) or
numeric (i.e., 0-9) characters. Alphabetic characters
in the ICC should be represented with uppercase
letters."
::= { mplsTunnelExtNodeIccMapEntry 2 }
mplsTunnelExtNodeIccMapNodeId OBJECT-TYPE
SYNTAX MplsNodeId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Node_ID within the
ICC-based operator."
::= { mplsTunnelExtNodeIccMapEntry 3}
mplsTunnelExtNodeIccMapLocalId OBJECT-TYPE
SYNTAX MplsExtendedTunnelId
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an ICC-based local identifier
that is defined in mplsTunnelExtNodeConfigTable."
::= { mplsTunnelExtNodeIccMapEntry 4 }
-- End MPLS Transport Profile Node ICC-based table
-- Start of MPLS Tunnel table extension
mplsTunnelExtTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsTunnelExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table represents extensions to mplsTunnelTable
in order to support MPLS-TP Tunnels.
As per MPLS-TP Identifiers (RFC 6370), LSP_ID for IP-based
co-routed bidirectional tunnel:
A1-{Global_ID::Node_ID::Tunnel_Num}::Z9-{Global_ID::
Node_ID::Tunnel_Num}::LSP_Num
LSP_ID for IP based associated bidirectional tunnel:
A1-{Global_ID::Node_ID::Tunnel_Num::LSP_Num}::
Z9-{Global_ID::Node_ID::Tunnel_Num::LSP_Num}
mplsTunnelTable is reused for forming the LSP_ID
as follows:
Source Tunnel_Num is mapped with mplsTunnelIndex,
Source Node_ID is mapped with
mplsTunnelIngressLSRId, Destination Node_ID is
mapped with mplsTunnelEgressLSRId, and LSP_Num is mapped with
mplsTunnelInstance.
Source Global_ID::Node_ID and/or ICC_Operator_ID::Node_ID and
Destination Global_ID::Node_ID and/or ICC_Operator_ID::Node-ID
are maintained in the mplsTunnelExtNodeConfigTable.
mplsTunnelExtNodeConfigLocalId is used to create an entry
in mplsTunnelTable."
REFERENCE
"MPLS Transport Profile (MPLS-TP) Identifiers, RFC 6370."
::= { mplsTeExtObjects 5 }
mplsTunnelExtEntry OBJECT-TYPE
SYNTAX MplsTunnelExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents additional MPLS-TP-
specific tunnel configurations."
INDEX {
mplsTunnelIndex,
mplsTunnelInstance,
mplsTunnelIngressLSRId,
mplsTunnelEgressLSRId
}
::= { mplsTunnelExtTable 1 }
MplsTunnelExtEntry ::= SEQUENCE {
mplsTunnelExtOppositeDirPtr RowPointer,
mplsTunnelExtOppositeDirTnlValid TruthValue,
mplsTunnelExtDestTnlIndex MplsTunnelIndex,
mplsTunnelExtDestTnlLspIndex MplsTunnelInstanceIndex,
mplsTunnelExtDestTnlValid TruthValue,
mplsTunnelExtIngressLSRLocalIdValid TruthValue,
mplsTunnelExtEgressLSRLocalIdValid TruthValue
}
mplsTunnelExtOppositeDirPtr OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object points to the opposite-direction tunnel entry."
::= { mplsTunnelExtEntry 1 }
mplsTunnelExtOppositeDirTnlValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes whether or not this tunnel uses
mplsTunnelExtOppositeDirPtr for identifying the opposite-
direction tunnel information. Note that if this variable
is set to true, then the mplsTunnelExtOppositeDirPtr should
point to the first accessible row of the valid opposite-
direction tunnel."
DEFVAL { false }
::= { mplsTunnelExtEntry 2 }
mplsTunnelExtDestTnlIndex OBJECT-TYPE
SYNTAX MplsTunnelIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is applicable only for the bidirectional
tunnel that has the forward and reverse LSPs in the
different tunnel entries.
The values of this object and the
mplsTunnelExtDestTnlLspIndex object together can be used
to identify an opposite-direction LSP, i.e., if the
mplsTunnelIndex and mplsTunnelInstance hold the value
for forward LSP, this object and
mplsTunnelExtDestTnlLspIndex can be used to retrieve
the reverse-direction LSP and vice versa.
This object and mplsTunnelExtDestTnlLspIndex values
provide the first two indices of tunnel entry, and
the remaining indices can be derived as follows:
the Ingress and Egress Identifiers should be
swapped in order to index the other direction tunnel."
::= { mplsTunnelExtEntry 3 }
mplsTunnelExtDestTnlLspIndex OBJECT-TYPE
SYNTAX MplsTunnelInstanceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is applicable only for the bidirectional
tunnel that has the forward and reverse LSPs in the
different tunnel entries. This object holds
the instance index of the opposite-direction tunnel."
::= { mplsTunnelExtEntry 4 }
mplsTunnelExtDestTnlValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Denotes whether or not this tunnel uses
mplsTunnelExtDestTnlIndex and
mplsTunnelExtDestTnlLspIndex for identifying
the opposite-direction tunnel information. Note that if
this variable is set to true, then the
mplsTunnelExtDestTnlIndex and
mplsTunnelExtDestTnlLspIndex objects should have
the valid opposite-direction tunnel indices."
DEFVAL { false }
::= { mplsTunnelExtEntry 5 }
mplsTunnelExtIngressLSRLocalIdValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object denotes whether the mplsTunnelIngressLSRId
contains the local value that is used to reference
the complete Ingress Global_ID::Node_ID or ICC_Operator_ID
from the mplsTunnelExtNodeConfigTable.
If this object is set to FALSE, mplsTunnelExtNodeConfigTable
will not contain an entry to reference the local identifier
with Global_ID::Node_ID or ICC_Operator_ID::Node_ID value.
This object is set to FALSE for legacy implementations like
MPLS TE tunnels where mplsTunnelIngressId itself provides
the complete Ingress LSR ID."
REFERENCE
"MPLS-TE-STD-MIB (RFC 3812), Section 11.
mplsTunnelIngressLSRId object in mplsTunnelTable."
DEFVAL { false }
::= { mplsTunnelExtEntry 6 }
mplsTunnelExtEgressLSRLocalIdValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object denotes whether the mplsTunnelEgressLSRId
contains the local value, which is used to reference
the complete Egress Global_ID::Node_ID or
ICC_Operator_ID::Node_ID from
the mplsTunnelExtNodeConfigTable.
If this object is set to FALSE, mplsTunnelExtNodeConfigTable
will not contain an entry to reference the local identifier
with Global_ID::Node_ID or ICC_Operator_ID::Node_ID value.
This object is set to FALSE for legacy implementations like
MPLS TE tunnels where mplsTunnelEgressId itself provides
the complete Egress LSR ID."
REFERENCE
"MPLS-TE-STD-MIB (RFC 3812), Section 11.
mplsTunnelEgressLSRId object in mplsTunnelTable."
DEFVAL { false }
::= { mplsTunnelExtEntry 7 }
-- End of MPLS Tunnel table extension
-- Module compliance.
mplsTeExtCompliances
OBJECT IDENTIFIER ::= { mplsTeExtConformance 1 }
mplsTeExtGroups
OBJECT IDENTIFIER ::= { mplsTeExtConformance 2 }
-- Compliance requirement for fully compliant implementations.
mplsTeExtModuleFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for agents that provide full
support the MPLS-TE-EXT-STD-MIB module."
MODULE -- this module
-- The mandatory group has to be implemented by all
-- LSRs that originate/terminate MPLS-TP Tunnels.
-- In addition, depending on the type of tunnels
-- supported, other groups become mandatory as
-- explained below.
MANDATORY-GROUPS {
mplsTunnelExtGroup
}
GROUP mplsTunnelExtIpOperatorGroup
DESCRIPTION
"This group is mandatory for devices that support
configuration of IP-based identifier tunnels."
GROUP mplsTunnelExtIccOperatorGroup
DESCRIPTION
"This group is mandatory for devices that support
configuration of ICC based tunnels."
::= { mplsTeExtCompliances 1 }
-- Compliance requirement for read-only implementations.
mplsTeExtModuleReadOnlyCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for agents that only provide
read-only support for the MPLS-TE-EXT-STD-MIB module."
MODULE -- this module
MANDATORY-GROUPS {
mplsTunnelExtGroup
}
GROUP mplsTunnelExtIpOperatorGroup
DESCRIPTION
"This group is mandatory for devices that support
configuration of IP-based identifier tunnels."
GROUP mplsTunnelExtIccOperatorGroup
DESCRIPTION
"This group is mandatory for devices that support
configuration of ICC-based tunnels."
-- mplsTunnelExtTable
OBJECT mplsTunnelExtOppositeDirPtr
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
the ICC map table and the whole tunnel extension table are in, and the compliance modules are wrapping up too β¨π
OBJECT mplsTunnelExtOppositeDirTnlValid
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelExtDestTnlIndex
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelExtDestTnlLspIndex
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelExtDestTnlValid
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelExtIngressLSRLocalIdValid
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelExtEgressLSRLocalIdValid
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelExtNodeConfigGlobalId
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelExtNodeConfigNodeId
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelExtNodeConfigStorageType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelExtNodeConfigRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelExtNodeConfigCcId
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelExtNodeConfigIccId
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsTunnelExtNodeConfigIccValid
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { mplsTeExtCompliances 2 }
-- Units of conformance.
mplsTunnelExtGroup OBJECT-GROUP
OBJECTS {
mplsTunnelExtOppositeDirPtr,
mplsTunnelExtOppositeDirTnlValid,
mplsTunnelExtDestTnlIndex,
mplsTunnelExtDestTnlLspIndex,
mplsTunnelExtDestTnlValid,
mplsTunnelExtIngressLSRLocalIdValid,
mplsTunnelExtEgressLSRLocalIdValid
}
STATUS current
DESCRIPTION
"Necessary, but not sufficient, set of objects to
implement tunnels. In addition, depending on the
operating environment, the following groups are
mandatory."
::= { mplsTeExtGroups 1 }
mplsTunnelExtIpOperatorGroup OBJECT-GROUP
OBJECTS { mplsTunnelExtNodeConfigLocalIdNext,
mplsTunnelExtNodeConfigGlobalId,
mplsTunnelExtNodeConfigNodeId,
mplsTunnelExtNodeIpMapLocalId,
mplsTunnelExtNodeConfigStorageType,
mplsTunnelExtNodeConfigRowStatus
}
STATUS current
DESCRIPTION
"Object(s) needed to implement IP-compatible tunnels."
::= { mplsTeExtGroups 2 }
mplsTunnelExtIccOperatorGroup OBJECT-GROUP
OBJECTS { mplsTunnelExtNodeConfigLocalIdNext,
mplsTunnelExtNodeConfigCcId,
mplsTunnelExtNodeConfigIccId,
mplsTunnelExtNodeConfigNodeId,
mplsTunnelExtNodeConfigIccValid,
mplsTunnelExtNodeIccMapLocalId,
mplsTunnelExtNodeConfigStorageType,
mplsTunnelExtNodeConfigRowStatus
}
STATUS current
DESCRIPTION
"Object(s) needed to implement ICC-based tunnels."
::= { mplsTeExtGroups 3 }
-- MPLS-TE-EXT-STD-MIB module ends
END
14. Security Considerations π
okay so this section is the serious one, bestie π«Ά This document follows the security considerations from Section 12 of [RFC3812]. Those same considerations also apply to the MIB objects and tables defined in this document, and they're listed below. π
- The common objects mplsIdGlobalId, mplsIdNodeId, mplsIdCc, and mplsIdIcc are used to define the identity of an MPLS-TP node for OAM purposes. If write-access is allowed to these objects, it opens the door for incorrect values to be entered, which will confuse the information returned by OAM functions and possibly stop OAM from operating correctly. Furthermore, there's the possibility of inducing one node to impersonate another, with confusing results. π
- mplsTunnelExtNodeConfigTable, mplsTunnelExtTable, and mplsXCExtTable together contain objects to provision MPLS-TP Tunnels, tunnel hops, and tunnel resources. π§
Some of the readable objects in this MIB module (that is, objects with a MAX-ACCESS other than not-accessible) may be considered sensitive or vulnerable in some network environments. So it's important to control even GET and/or NOTIFY access to these objects, and possibly even to encrypt their values when sending them over the network via SNMP. π₯ These are the tables and objects, and their sensitivity or vulnerability:
- mplsTunnelExtNodeConfigTable, mplsTunnelExtTable, and mplsXCExtTable together show the characteristics of the MPLS-TP tunnel network topology. If an Administrator doesn't want to reveal this information, then these tables should be considered sensitive or vulnerable. π
SNMP versions prior to SNMPv3 did not include adequate security. Even if the network itself is secure (for example, by using IPsec), there is no control over who on the secure network is allowed to access and GET/SET (read/change/create/delete) the objects in this MIB module. π
Implementations SHOULD provide the security features described by the SNMPv3 framework (see [RFC3410]). Implementations claiming compliance with the SNMPv3 standard MUST include full support for authentication and privacy via the User-based Security Model (USM) [RFC3414] with the AES cipher algorithm [RFC3826]. Implementations MAY also provide support for the Transport Security Model (TSM) [RFC5591] in combination with a secure transport such as SSH [RFC5592] or TLS/DTLS [RFC6353]. β¨
Further, deploying SNMP versions prior to SNMPv3 is NOT RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to enable cryptographic security. It is then a customer or operator responsibility to ensure that the SNMP entity giving access to an instance of this MIB module is properly configured, so that access to the objects is given only to those principals (users) who have legitimate rights to GET or SET (change/create/delete) them. π
15. IANA Considerations π
As described in [RFC4221] and [RFC6639], and as requested in the MPLS-TC-STD-MIB [RFC3811], MPLS-related Standards Track MIB modules should be rooted under the mplsStdMIB subtree. There are four MPLS MIB modules in this document, and each of the following subsections lists a new assignment made by IANA under the mplsStdMIB subtree. New assignments can only be made via a Standards Action as specified in [RFC5226]. π¦
15.1. IANA Considerations for MPLS-TC-EXT-STD-MIB
IANA has assigned the OID { mplsStdMIB 17 } to the MPLS-TC-EXT-STD-MIB module specified in this document. π
15.2. IANA Considerations for MPLS-ID-STD-MIB
IANA has assigned the OID { mplsStdMIB 18 } to the MPLS-ID-STD-MIB module specified in this document. πΈ
15.3. IANA Considerations for MPLS-LSR-EXT-STD-MIB
IANA has assigned the OID { mplsStdMIB 19 } to the MPLS-LSR-EXT-STD-MIB module specified in this document. π
15.4. IANA Considerations for MPLS-TE-EXT-STD-MIB
IANA has assigned the OID { mplsStdMIB 20 } to the MPLS-TE-EXT-STD-MIB module specified in this document. π
16. References π
16.1. Normative References
- [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", BCP 14, RFC 2119, March 1997, <http://www.rfc-editor.org/info/rfc2119>.
- [RFC2578] McCloghrie, K., Ed., Perkins, D., Ed., and J. Schoenwaelder, Ed., "Structure of Management Information Version 2 (SMIv2)", STD 58, RFC 2578, April 1999, <http://www.rfc-editor.org/info/rfc2578>.
- [RFC2579] McCloghrie, K., Ed., Perkins, D., Ed., and J. Schoenwaelder, Ed., "Textual Conventions for SMIv2", STD 58, RFC 2579, April 1999, <http://www.rfc-editor.org/info/rfc2579>.
- [RFC2580] McCloghrie, K., Ed., Perkins, D., Ed., and J. Schoenwaelder, Ed., "Conformance Statements for SMIv2", STD 58, RFC 2580, April 1999, <http://www.rfc-editor.org/info/rfc2580>.
- [RFC3031] Rosen, E., Viswanathan, A., and R. Callon, "Multiprotocol Label Switching Architecture", RFC 3031, January 2001, <http://www.rfc-editor.org/info/rfc3031>.
- [RFC3289] Baker, F., Chan, K., and A. Smith, "Management Information Base for the Differentiated Services Architecture", RFC 3289, May 2002, <http://www.rfc-editor.org/info/rfc3289>.
- [RFC3811] Nadeau, T., Ed., and J. Cucchiara, Ed., "Definitions of Textual Conventions (TCs) for Multiprotocol Label Switching (MPLS) Management", RFC 3811, June 2004, <http://www.rfc-editor.org/info/rfc3811>.
- [RFC3812] Srinivasan, C., Viswanathan, A., and T. Nadeau, "Multiprotocol Label Switching (MPLS) Traffic Engineering (TE) Management Information Base (MIB)", RFC 3812, June 2004, <http://www.rfc-editor.org/info/rfc3812>.
- [RFC3813] Srinivasan, C., Viswanathan, A., and T. Nadeau, "Multiprotocol Label Switching (MPLS) Label Switching Router (LSR) Management Information Base (MIB)", RFC 3813, June 2004, <http://www.rfc-editor.org/info/rfc3813>.
- [RFC4802] Nadeau, T., Ed., and A. Farrel, Ed., "Generalized Multiprotocol Label Switching (GMPLS) Traffic Engineering Management Information Base", RFC 4802, February 2007, <http://www.rfc-editor.org/info/rfc4802>.
- [RFC6370] Bocci, M., Swallow, G., and E. Gray, "MPLS Transport Profile (MPLS-TP) Identifiers", RFC 6370, September 2011, <http://www.rfc-editor.org/info/rfc6370>.
- [RFC6923] Winter, R., Gray, E., van Helvoort, H., and M. Betts, "MPLS Transport Profile (MPLS-TP) Identifiers Following ITU-T Conventions", RFC 6923, May 2013, <http://www.rfc-editor.org/info/rfc6923>.
- [T.50] ITU-T, "International Reference Alphabet (IRA) (Formerly International Alphabet No. 5 or IA5) - Information technology - 7-bit coded character set for information exchange", ITU-T Recommendation T.50, September 1992.
16.2. Informative References π
Okay bestie, these are the "good to know" reads πΈ You don't need them to build the thing, but they're the background lore that makes everything else click π
[RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart, "Introduction and Applicability Statements for Internet-Standard Management Framework", RFC 3410, December 2002, <http://www.rfc-editor.org/info/rfc3410>.
[RFC3414] Blumenthal, U. and B. Wijnen, "User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)", STD 62, RFC 3414, December 2002, <http://www.rfc-editor.org/info/rfc3414>.
[RFC3826] Blumenthal, U., Maino, F., and K. McCloghrie, "The Advanced Encryption Standard (AES) Cipher Algorithm in the SNMP User-based Security Model", RFC 3826, June 2004, <http://www.rfc-editor.org/info/rfc3826>.
[RFC4221] Nadeau, T., Srinivasan, C., and A. Farrel, "Multiprotocol Label Switching (MPLS) Management Overview", RFC 4221, November 2005, <http://www.rfc-editor.org/info/rfc4221>.
[RFC5226] Narten, T. and H. Alvestrand, "Guidelines for Writing an IANA Considerations Section in RFCs", BCP 26, RFC 5226, May 2008, <http://www.rfc-editor.org/info/rfc5226>.
[RFC5591] Harrington, D. and W. Hardaker, "Transport Security Model for the Simple Network Management Protocol (SNMP)", STD 78, RFC 5591, June 2009, <http://www.rfc-editor.org/info/rfc5591>.
[RFC5592] Harrington, D., Salowey, J., and W. Hardaker, "Secure Shell Transport Model for the Simple Network Management Protocol (SNMP)", RFC 5592, June 2009, <http://www.rfc-editor.org/info/rfc5592>.
[RFC5654] Niven-Jenkins, B., Ed., Brungard, D., Ed., Betts, M., Ed., Sprecher, N., and S. Ueno, "Requirements of an MPLS Transport Profile", RFC 5654, September 2009, <http://www.rfc-editor.org/info/rfc5654>.
[RFC6353] Hardaker, W., "Transport Layer Security (TLS) Transport Model for the Simple Network Management Protocol (SNMP)", STD 78, RFC 6353, July 2011, <http://www.rfc-editor.org/info/rfc6353>.
[RFC6639] King, D., Ed., and M. Venkatesan, Ed., "Multiprotocol Label Switching Transport Profile (MPLS-TP) MIB-Based Management Overview", RFC 6639, June 2012, <http://www.rfc-editor.org/info/rfc6639>.
Acknowledgments π
The authors wanna give a huge shoutout to Francesco Fondelli, Josh Littlefield, Agrahara Kiran Koushik, Metrri Jain, Muly Ilan, Randy Presuhn, Elwyn Davies, Tom Taylor, and Pete Resnick for their valuable reviews and comments π«Ά A special thanks to Joan Cucchiara and Adrian Farrel for really getting the MIB modules into shape π
Authors' Addresses π
Venkatesan Mahalingam
Dell Inc.
5450 Great America Parkway,
Santa Clara, CA 95054
United States
EMail: venkat.mahalingams@gmail.com
Sam Aldrin
Huawei Technologies
2330 Central Express Way,
Santa Clara, CA 95051
United States
EMail: aldrin.ietf@gmail.com
Thomas D. Nadeau
Brocade
EMail: tnadeau@lucidvision.com
Kannan KV Sampath
Redeem
India
EMail: kannankvs@gmail.com
π¦ where this page comes from
- ietf: rfc7453 2015-02