Okay bestie, let's get into it โœจ This is RFC 6998, published in August 2013 and classified as Experimental ๐Ÿงช It's an IETF document with ISSN 2070-1721. It was written by M. Goyal, Ed. (Univ. of Wisconsin Milwaukee), E. Baccelli (INRIA), A. Brandt (Sigma Designs), and J. Martocci (Johnson Controls) ๐Ÿ‘‘ The title block doesn't list anything it obsoletes or updates, so it's standing on its own ๐Ÿ’…

Abstract โœจ

This doc defines a way for an RPL router (RPL = the IPv6 Routing Protocol for Low-power and Lossy Networks) to measure the combined values of chosen routing metrics along a route that already exists toward another RPL router ๐ŸŒธ Once it has those numbers, the router can decide whether it's worth going hunting for a better route ๐Ÿ”

Status of This Memo ๐ŸŽ€

Not me being dramatic, but this one is not an Internet Standards Track spec. It's published so people can examine it, try out an experimental implementation, and evaluate it ๐Ÿง

It's still an Experimental Protocol for the Internet community, and it's a product of the Internet Engineering Task Force (IETF) ๐Ÿซถ It represents the consensus of the IETF community, got public review, and was approved for publication by the Internet Engineering Steering Group (IESG). Just because the IESG approved something doesn't mean it's a candidate for any level of Internet Standard, so check Section 2 of RFC 5741 if you're curious ๐Ÿ™ˆ

If you want the current status, any errata, or a way to send feedback, head to http://www.rfc-editor.org/info/rfc6998 ๐Ÿฆ‹

The copyright here is Copyright (c) 2013 IETF Trust and the persons identified as the document authors, and all rights are reserved ๐Ÿ”’

This doc is subject to BCP 78 and the IETF Trust's Legal Provisions Relating to IETF Documents (http://trustee.ietf.org/license-info) as they were in effect on the publication date. Read them carefully, because they explain your rights and restrictions ๐Ÿ“œ Any Code Components pulled out of this document must include the Simplified BSD License text, as described in Section 4.e of the Trust Legal Provisions, and they come with no warranty, as the Simplified BSD License explains ๐Ÿ’…

Table of Contents ๐Ÿงš

   1. Introduction ....................................................4
      1.1. Terminology ................................................5
   2. Overview ........................................................6
   3. The Measurement Object (MO) .....................................7
      3.1. Format of the Base MO ......................................8
      3.2. Secure MO .................................................12
   4. Originating a Measurement Request ..............................13
      4.1. When Measuring a Hop-by-Hop Route with a Global
           RPLInstanceID .............................................14
      4.2. When Measuring a Hop-by-Hop Route with a Local
           RPLInstanceID with Route Accumulation Off .................15
      4.3. When Measuring a Hop-by-Hop Route with a Local
           RPLInstanceID with Route Accumulation On ..................16
      4.4. When Measuring a Source Route .............................17
   5. Processing a Measurement Request at an Intermediate Point ......19
      5.1. When Measuring a Hop-by-Hop Route with a Global
           RPLInstanceID .............................................19
      5.2. When Measuring a Hop-by-Hop Route with a Local
           RPLInstanceID with Route Accumulation Off .................21
      5.3. When Measuring a Hop-by-Hop Route with a Local
           RPLInstanceID with Route Accumulation On ..................21
      5.4. When Measuring a Source Route .............................22
      5.5. Final Processing ..........................................23
   6. Processing a Measurement Request at the End Point ..............23
      6.1. Generating the Measurement Reply ..........................24
   7. Processing a Measurement Reply at the Start Point ..............25
   8. Security Considerations ........................................25
   9. IANA Considerations ............................................27
   10. Acknowledgements ..............................................27
   11. References ....................................................28
      11.1. Normative References .....................................28
      11.2. Informative References ...................................28

1. Introduction ๐ŸŒˆ

Okay so, point-to-point (P2P) communication between any routers in a Low-power and Lossy Network (LLN) is a must-have for lots of home and commercial building automation apps ๐Ÿ  [RFC5826] [RFC5867] The IPv6 Routing Protocol for LLNs (RPL) [RFC6550] keeps the LLN topology as a Directed Acyclic Graph (DAG) that's built to optimize routing costs for reaching the DAG's root ๐ŸŒณ Honestly, the P2P routing that RPL offers has two big limitations ๐Ÿ˜ญ

  • The P2P routes can only use DAG links. Those routes might be suboptimal, and they can cause traffic congestion near the DAG root ๐Ÿšฆ
  • RPL is proactive, so every P2P route has to be set up before it gets used โฐ A lot of LLN apps need to set up P2P routes "on demand," which is a whole vibe RPL doesn't give them ๐Ÿ’”

When core RPL's P2P routing doesn't meet an app's needs, [RFC6997] describes P2P-RPL, which extends core RPL ๐Ÿฆ‹ P2P-RPL is reactive, meaning it finds P2P routes that satisfy the given routing constraints [RFC6551] ๐Ÿ‘‘ Sometimes the app's requirements, or the LLN's topology, let a router figure out those constraints on its own. For example, an app might need the end-to-end loss rate and/or latency along the route to stay under certain thresholds. Or the LLN topology might make it safe for a router to assume its destination is less than a certain number of hops away ๐Ÿง 

Now, when the existing routes are unsatisfying but the router doesn't implicitly know which routing constraints to use for P2P-RPL route discovery, the router may need to measure the aggregated values of the routing metrics along the existing route ๐Ÿ“Š Those numbers help the router come up with reasonable constraints so it can find a better route with P2P-RPL ๐Ÿ’ก For example, if the router finds that the aggregate ETX (expected transmission count) [RFC6551] along an existing route is "x," it can use ETX < x*y as the routing constraint for P2P-RPL route discovery, where y is a certain fraction ๐Ÿงฎ Be careful though: the constraints shouldn't be overly strict, or P2P-RPL route discovery might fail even when a much better route exists ๐Ÿ™ˆ

This document defines a mechanism that lets an RPL router measure the aggregated values of routing metrics along an existing route to another RPL router in an LLN โœจ That helps the router decide whether to discover a better route using P2P-RPL, and helps it pick the routing constraints to use for that ๐ŸŽฏ So the usefulness of this mechanism depends on P2P-RPL existing [RFC6997] ๐Ÿซถ The hope is that experiments with P2P-RPL and this mechanism produce feedback on how useful and beneficial this document is, so a Standards Track version can be developed later ๐ŸŒธ

1.1. Terminology ๐ŸŽ€

The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in [RFC2119] ๐Ÿ“–

This doc also uses terminology from [RFC6550], [RFC6554], and [RFC6997]. More terms can be found in [ROLL-TERMS]. This document defines the following terms ๐Ÿ’œ

Start Point: The RPL router that starts the measurement process defined in this document, and that is the start point of the P2P route being measured ๐Ÿš€

End Point: The RPL router at the end point of the P2P route being measured ๐Ÿ

Intermediate Point: An RPL router, other than the Start Point and the End Point, that sits on the P2P route being measured ๐Ÿฆ‹

The following terms are already defined in [RFC6997], but this document redefines them as follows ๐ŸŒˆ

Forward direction: The direction from the Start Point to the End Point โžก๏ธ

Reverse direction: The direction from the End Point to the Start Point โฌ…๏ธ

2. Overview ๐Ÿ’–

okay bestie, this is where it gets good โœจ A Start Point inside an LLN can use this mechanism to measure the aggregated values of selected routing metrics along a P2P route to an End Point in the same LLN. The route gets measured in the Forward direction ๐Ÿฆ‹ That route could be a Source Route, or a Hop-by-hop Route set up with RPL [RFC6550] or P2P-RPL [RFC6997]. It could also be a "mixed" route: hop-by-hop ascent up to the root of a non-storing DAG [RFC6550], then a source-routed descent down to the End Point. Main character energy ๐Ÿ’…

The Start Point decides which metrics it wants to measure and sends a Measurement Request message, carrying the routing metric objects it wants, along the route. If a Source Route is being measured, the Measurement Request carries the route inside an Address vector. If a Hop-by-hop Route is being measured, the Measurement Request identifies the route by its RPLInstanceID [RFC6550] (and, if the RPLInstanceID is a local value, the Start Point's IPv6 address associated with the route). When an Intermediate Point gets a Measurement Request, it updates the routing metric values inside the message and forwards it to the next hop on the route. So the Measurement Request is basically collecting values for the whole route as it travels toward the End Point ๐Ÿงš

When the End Point gets the Measurement Request, it unicasts a Measurement Reply message, carrying the accumulated routing metric values, back to the Start Point. Optionally, the Start Point may allow an Intermediate Point to generate the Measurement Reply if that Intermediate Point already knows the relevant routing metric values along the rest of the route ๐ŸŒธ

The Measurement Request may include an Address vector that does one of two jobs:

  • To accumulate a Source Route for the End Point's use: If a Hop-by-hop Route with a local RPLInstanceID is being measured, the Start Point may require that each Intermediate Point add its global or unique-local IPv6 address to an Address vector inside the Measurement Request. The Source Route, thus accumulated, can be used by the End Point to reach the Start Point. In particular, the End Point may use the accumulated Source Route to send the Measurement Reply back to the Start Point. In this case, the Start Point includes a suitably sized Address vector in the Measurement Request. The size of the Address vector puts a hard limit on the length of the accumulated route. An Intermediate Point is not allowed to modify the size of the Address vector and must discard a received Measurement Request if the Address vector is not large enough to contain the complete route. ๐Ÿซถ
  • To carry the Source Route being measured: The Start Point may insert an Address vector inside the Measurement Request to carry the Source Route being measured. Also, the root of a global non-storing DAG may insert an Address vector, carrying a Source Route from itself to the End Point, inside a Measurement Request message if this message had been traveling along this DAG so far. This Source Route must consist of global or unique-local IPv6 addresses. An Intermediate Point is not allowed to modify an existing Address vector before forwarding the Measurement Request further. In other words, an Intermediate Point must not modify the Source Route along which the Measurement Request is currently traveling. ๐Ÿ”ฅ

3. The Measurement Object (MO) ๐ŸŽ€

This document defines two new RPL control message types: the Measurement Object (MO), with code 0x06; and the Secure MO, with code 0x86. An MO serves as both Measurement Request and Measurement Reply. Two jobs, one object, very efficient ๐Ÿ“

3.1. Format of the Base MO

      0                   1                   2                   3
      0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
     | RPLInstanceID | Compr |T|H|A|R|B|I|   SeqNo   |  Num  | Index |
     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
     |                                                               |
     .                       Start Point Address                     .
     .                                                               .
     |                                                               |
     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
     |                                                               |
     .                       End Point Address                       .
     .                                                               .
     |                                                               |
     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
     |                                                               |
     .                       Address[0..Num-1]                       .
     .                                                               .
     |                                                               |
     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
     |                                                               |
     .                   Metric Container Option(s)                  .
     .                                                               .
     |                                                               |
     +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

           Figure 1: Format of the Base Measurement Object (MO)

The format of a base MO is shown in Figure 1. A base MO consists of the following fields:

  • RPLInstanceID: This field specifies the RPLInstanceID of the Hop-by-hop Route along which the Measurement Request travels (or traveled initially until it switched over to a Source Route). ๐ŸŒˆ
  • Compr: In many LLN deployments, IPv6 addresses share a well-known, common prefix. In such cases, the common prefix can be elided when specifying IPv6 addresses in the Start Point/End Point Address fields and the Address vector. The "Compr" field, a 4-bit unsigned integer, is set by the Start Point to specify the number of prefix octets that are elided from the IPv6 addresses in Start Point/End Point Address fields and the Address vector. The Start Point will set the Compr value to zero if full IPv6 addresses are to be carried in the Start Point Address/End Point Address fields and the Address vector. โœ‚๏ธ
  • Type (T): This flag is set to one if the MO represents a Measurement Request. The flag is set to zero if the MO is a Measurement Reply. Request or reply, that's the whole vibe ๐Ÿ’œ
  • Hop-by-hop (H): The Start Point MUST set this flag to one if (at least the initial part of) the route being measured is hop by hop. In that case, the Hop-by-hop Route is identified by the RPLInstanceID, the End Point Address, and, if the RPLInstanceID is a local value, the Start Point Address fields inside the Measurement Request. Here, the Start Point Address field is required to be the same as the DODAGID (the identifier of the Destination-Oriented DAG (DODAG) root) [RFC6550] of the route being measured. The Start Point MUST set the H flag to zero if the route being measured is a Source Route specified in the Address vector. An Intermediate Point MUST set the H flag in an outgoing Measurement Request to the same value that it had in the corresponding incoming Measurement Request, except under the following circumstance: If the Intermediate Point is the root of the non-storing global DAG along which the Measurement Request had been traveling so far and it intends to insert a Source Route inside the Address vector to direct the Measurement Request towards the End Point, then it MUST set the H flag to zero. ๐Ÿฆ‹
  • Accumulate Route (A): A value of 1 in this flag indicates that the Measurement Request is accumulating a Source Route for use by the End Point to send the Measurement Reply back to the Start Point. Route accumulation MUST NOT be used (i.e., this flag MUST NOT be set to one) inside a Measurement Request, unless it travels along a Hop-by-hop Route represented by a local RPLInstanceID (i.e., H = 1 and RPLInstanceID has a local value). Route accumulation MAY be used (i.e., this flag MAY be set to one) if the Measurement Request is traveling along a Hop-by-hop Route with a local RPLInstanceID. In this case, if the route accumulation is on, an Intermediate Point adds its unicast global/unique-local IPv6 address (after eliding Compr number of prefix octets) to the Address vector in the manner specified in Section 5.3. In other cases, this flag MUST be set to zero on transmission and ignored on reception. Route accumulation is not allowed when the Measurement Request travels along a Hop-by-hop Route with a global RPLInstanceID, i.e., along a global DAG, because:
    • The DAG's root may need the Address vector to insert a Source Route to the End Point; and
    • The End Point can presumably reach the Start Point along this global DAG (identified by the RPLInstanceID field).
  • Reverse (R): A value of 1 in this flag inside a Measurement Request indicates that the Address vector contains a complete Source Route from the Start Point to the End Point, which can be used, after reversal, by the End Point to send the Measurement Reply back to the Start Point. This flag MAY be set to one inside a Measurement Request only if a Source Route, from the Start Point to the End Point, is being measured. Otherwise, this flag MUST be set to zero on transmission and ignored on reception. ๐Ÿ”„
  • Back Request (B): A value of 1 in this flag serves as a request to the End Point to send a Measurement Request towards the Start Point. On receiving a Measurement Request with the B flag set to one, the End Point SHOULD generate a Measurement Request to measure the cost of its current (or the most preferred) route to the Start Point. Receipt of this Measurement Request would allow the Start Point to know the cost of the back route from the End Point to itself and thus determine the round-trip cost of reaching the End Point. ๐ŸŽ
  • Intermediate Reply (I): A value of 1 in this flag serves as permission to an Intermediate Point to generate a Measurement Reply if it knows the aggregated values of the routing metrics being measured for the rest of the route. Setting this flag to one may be useful in scenarios where the Hop Count [RFC6551] is the routing metric of interest and an Intermediate Point (e.g., the root of a non-storing global DAG or a common ancestor of the Start Point and the End Point in a storing global DAG) may know the Hop Count of the remainder of the route to the End Point. This flag MAY be set to one only if a Hop-by-hop Route with a global RPLInstanceID is being measured (i.e., H = 1 and RPLInstanceID has a global value). Otherwise, this flag MUST be set to zero on transmission and ignored on reception. ๐Ÿงšโ€โ™€๏ธ
  • SeqNo: This is a 6-bit sequence number, assigned by the Start Point, that allows the Start Point to uniquely identify a Measurement Request and the corresponding Measurement Reply. Like a little ID badge for every request ๐Ÿท๏ธ
  • Num ๐Ÿงš: this tells you how many elements are in the Address vector, and each one is (16 - Compr) octets big. If the value of Num is zero, the Address vector isn't in the MO at all ๐Ÿซถ
  • Index ๐Ÿ’…: this one's the pointer โœจ. If the Measurement Request is riding a Source Route inside the Address vector (so H = 0), Index points at the next hop on that route. If it's traveling a Hop-by-hop Route with a local RPLInstanceID and route accumulation is on (H = 1, RPLInstanceID has a local value, and A = 1), Index tells an Intermediate Point which spot in the Address vector to store its IPv6 address in. Otherwise, this field MUST be set to zero on transmission and ignored on reception ๐Ÿ™ˆ
  • Start Point Address ๐ŸŒธ: a unicast global or unique-local IPv6 address for the Start Point, with Compr prefix octets elided. If the Measurement Request is on a Hop-by-hop Route and the RPLInstanceID field has a local value, the Start Point Address field MUST specify the DODAGID value that, together with the RPLInstanceID and the End Point Address, uniquely identifies the Hop-by-hop Route being measured. Main character energy ๐Ÿ‘‘
  • End Point Address ๐Ÿฆ‹: a unicast global or unique-local IPv6 address for the End Point, with Compr prefix octets elided.
  • Address[0..Num-1] ๐ŸŒˆ: this is a vector of unicast global or unique-local IPv6 addresses (with Compr prefix octets elided) that represents a Source Route:
    • Each element has a size of (16 - Compr) octets.
    • The total number of elements in the Address vector is given by Num.
    • The Start Point and End Point addresses MUST NOT be included in the Address vector.
    • The Address vector MUST NOT contain any multicast addresses.
    • If the Start Point wants to measure a Hop-by-hop Route with a local RPLInstanceID and accumulate a Source Route for the End Point's use (i.e., the Measurement Request has the H flag set to one, RPLInstanceID set to a local value, and the A flag set to one), it MUST include a suitably sized Address vector in the Measurement Request. As the Measurement Request travels over the route being measured, the Address vector accumulates a Source Route that the End Point can use, after reversal, to reach (and, in particular, to send the Measurement Reply back to) the Start Point. The route MUST be accumulated in the Forward direction, but the IPv6 addresses in the accumulated route MUST be reachable in the Reverse direction. An Intermediate Point MUST add only a global or unique-local IPv6 address to the Address vector and MUST NOT modify the size of the Address vector.
    • If the Start Point wants to measure a Source Route, it MUST include an Address vector, containing the route being measured, inside the Measurement Request. Similarly, if the Measurement Request had been traveling along a global non-storing DAG so far, the root of this DAG may insert an Address vector, containing a Source Route from itself to the End Point, inside the Measurement Request. In both cases, the Source Route inside the Address vector MUST consist only of global or unique-local IPv6 addresses that are reachable in the Forward direction. Further, in both cases, an Intermediate Point MUST NOT modify the contents of the existing Address vector before forwarding the Measurement Request further. In other words, an Intermediate Point MUST NOT modify the Source Route along which the Measurement Request is currently traveling. The Start Point MAY set the R flag in the Measurement Request to one if the Source Route inside the Address vector can be used by the End Point, after reversal, to reach (and, in particular, to send the Measurement Reply back to) the Start Point. In other words, the Start Point MAY set the R flag to one only if all the IPv6 addresses in the Address vector are reachable in the Reverse direction.
  • Metric Container Options โญ: A Measurement Request MUST contain one or more Metric Container options [RFC6550] to accumulate the values of the selected routing metrics in the manner described in [RFC6551] for the route being measured.

Section 4 covers how a Start Point sets the various fields in a Measurement Request in different cases. Section 5 covers how an Intermediate Point processes a received Measurement Request before forwarding it further. Section 6 covers how the End Point processes a received Measurement Request and generates a Measurement Reply. Finally, Section 7 covers how the Start Point processes a received Measurement Reply. In the discussion that follows, any reference to discarding a received Measurement Request/Reply with "no further processing" doesn't stop you from updating the appropriate error counters or doing any similar actions. ๐Ÿ“

3.2. Secure MO ๐Ÿ”

A Secure MO follows the format shown in Figure 7 of [RFC6550], where the base format is the base MO shown in Figure 1. Sections 6.1, 10, and 19 of [RFC6550] describe the RPL security framework. These sections apply to the use of Secure MO messages as well, except as constrained in this section. An LLN deployment MUST support the use of Secure MO messages so that it can invoke RPL-provided security mechanisms and prevent misuse of the measurement mechanism by unauthorized routers. ๐Ÿ›ก๏ธ

The Start Point decides whether Secure MO messages are used in a particular route measurement and, if so, which Security Configuration (see the definition in [RFC6997]) to use for that purpose. The Start Point MUST NOT set the "Key Identifier Mode" field to a value of 1 inside this Security Configuration, since that setting indicates the use of a per-pair key, which isn't suitable for securing Measurement Request messages that travel over multiple hops. A router (an Intermediate Point or the End Point) participating in a particular route measurement:

  • MUST generate a Secure MO message (a Measurement Request or a Measurement Reply) if the received Measurement Request is a Secure MO. The Security Configuration used in generating a Secure MO message MUST be the same as the one used in the received message.
  • MUST NOT generate a Secure MO message if the received Measurement Request is not a Secure MO.

A router MUST discard a received Measurement Request if it can't follow the rules above. If the Start Point sends a Measurement Request in a Secure MO message using a particular Security Configuration, it MUST discard the corresponding Measurement Reply it receives with no further processing, unless the Measurement Reply is received in a Secure MO message generated with the same Security Configuration as the one used in the Measurement Request.

In the discussion that follows, any reference to an MO message also applies to a Secure MO message, unless noted otherwise. ๐Ÿ’–

4. Originating a Measurement Request โœจ

A Start Point sets the various fields inside the Measurement Request it generates in the manner described below. The Start Point MUST also include the routing metric objects [RFC6551] of interest inside one or more Metric Container options inside the Measurement Request. The Start Point then determines the next hop on the route being measured. If a Hop-by-hop Route is being measured (i.e., H = 1), the next hop is determined using the RPLInstanceID, the End Point Address, and, if RPLInstanceID is a local value, the Start Point Address fields in the Measurement Request. If a Source Route is being measured (i.e., H = 0), the Address[0] element inside the Measurement Request contains the next-hop address. The Start Point MUST ensure that:

  • the next-hop address is a unicast address, and
  • the next hop is on-link, and
  • the next hop is in the same RPL routing domain [RFC6554] as the Start Point,

failing which the Start Point MUST discard the Measurement Request without sending. Depending on the routing metrics, the Start Point must initiate the routing metric objects inside the Metric Container options by including the routing metric values for the first hop on the route being measured. Finally, the Start Point MUST unicast the Measurement Request to the next hop on the route being measured. ๐Ÿš€

The Start Point MUST maintain state for a just-transmitted Measurement Request, for a lifetime duration that is large enough to allow the corresponding Measurement Reply to return. This state consists of the RPLInstanceID, the SeqNo, and the End Point Address fields of the Measurement Request. The lifetime duration for this state is locally determined by the Start Point and may be deployment specific. This state expires when the corresponding Measurement Reply is received or when the lifetime is over, whichever happens first. Failure to receive the corresponding Measurement Reply before the state expires may occur for a number of reasons, including the unwillingness of an Intermediate Point or the End Point to process the Measurement Request. The Start Point should take such possibilities into account when deciding whether to generate another Measurement Request for this route. The Start Point MUST discard a received Measurement Reply with no further processing if the state for the corresponding Measurement Request has already expired. โณ

4.1. When Measuring a Hop-by-Hop Route with a Global RPLInstanceID ๐ŸŒ

If a Hop-by-hop Route with a global RPLInstanceID is being measured (i.e., H = 1 and RPLInstanceID has a global value), the MO MUST NOT contain an Address vector, and the various MO fields MUST be set in the following manner:

  • RPLInstanceID: This field MUST be set to the RPLInstanceID of the route being measured.
  • Compr: This field MUST be set to specify the number of prefix octets that are elided from the IPv6 addresses in the Start Point/End Point Address fields.
  • Type (T): This flag MUST be set to one, since the MO represents a Measurement Request.
  • Hop-by-hop (H): This flag MUST be set to one.
  • Accumulate Route (A): This flag MUST be set to zero.
  • Reverse (R): This flag MUST be set to zero.
  • Back Request (B): This flag MAY be set to one to request that the End Point send a Measurement Request to the Start Point.
  • Intermediate Reply (I): This flag MAY be set to one if the Start Point expects an Intermediate Point to know the values of the routing metrics being measured for the remainder of the route.
  • SeqNo: This is assigned by the Start Point so that it can uniquely identify the Measurement Request and the corresponding Measurement Reply.
  • Num: This field MUST be set to zero.
  • Index: This field MUST be set to zero.
  • Start Point Address: This field MUST be set to a unicast global/unique-local IPv6 address of the Start Point after eliding Compr number of prefix octets.
  • End Point Address: This field MUST be set to a unicast global/unique-local IPv6 address of the End Point after eliding Compr number of prefix octets.

4.2. When Measuring a Hop-by-Hop Route with a Local RPLInstanceID with Route Accumulation Off ๐Ÿฆ‹

Okay bestie, so say a Hop-by-Hop route with a local RPLInstanceID is getting measured, and the Start Point is like "nah, I don't want the MO collecting a Source Route for the End Point to use" ๐Ÿ’…. Then the MO MUST NOT contain the Address vector, and a bunch of MO fields need to be set like this โœจ:

  • RPLInstanceID: This field MUST be set to the RPLInstanceID of the route being measured. ๐ŸŒธ
  • Compr: This field MUST be set to specify the number of prefix octets that are elided from the IPv6 addresses in Start Point/End Point Address fields. ๐ŸŽ€
  • Type (T): This flag MUST be set to one, since the MO represents a Measurement Request. ๐Ÿ’–
  • Hop-by-hop (H): This flag MUST be set to one. ๐Ÿฆ‹
  • Accumulate Route (A): This flag MUST be set to zero. ๐Ÿ™ˆ
  • Reverse (R): This flag MUST be set to zero. ๐Ÿ™ƒ
  • Back Request (B): This flag MAY be set to one to request that the End Point send a Measurement Request to the Start Point. ๐Ÿซถ
  • Intermediate Reply (I): This flag MUST be set to zero. ๐Ÿงš
  • SeqNo: This is assigned by the Start Point so that it can uniquely identify the Measurement Request and the corresponding Measurement Reply. ๐Ÿ”ฅ
  • Num: This field MUST be set to zero. ๐Ÿ“
  • Index: This field MUST be set to zero. ๐ŸŒˆ
  • Start Point Address: This field MUST contain the DODAGID value (after eliding Compr number of prefix octets) associated with the route being measured. This DODAGID MUST also be a global or unique-local IPv6 address of the Start Point. ๐Ÿ‘‘
  • End Point Address: This field MUST be set to a unicast global or unique-local IPv6 address of the End Point after eliding Compr number of prefix octets. ๐Ÿ’œ

4.3. When Measuring a Hop-by-Hop Route with a Local RPLInstanceID with Route Accumulation On โœจ

Now the other side of the coin ๐Ÿช™. If a Hop-by-Hop route with a local RPLInstanceID is being measured and the Start Point wants the MO to accumulate a Source Route so the End Point can send the Measurement Reply message back, then the MO MUST contain a suitably sized Address vector. Plus, various MO fields MUST be set like this ๐Ÿ‘€:

  • RPLInstanceID: This field MUST be set to the RPLInstanceID of the route being measured. ๐ŸŒธ
  • Compr: This field MUST be set to specify the number of prefix octets that are elided from the IPv6 addresses in Start Point/End Point Address fields and the Address vector. ๐ŸŽ€
  • Type (T): This flag MUST be set to one, since the MO represents a Measurement Request. ๐Ÿ’–
  • Hop-by-hop (H): This flag MUST be set to one. ๐Ÿฆ‹
  • Accumulate Route (A): This flag MUST be set to one. ๐Ÿ”ฅ
  • Reverse (R): This flag MUST be set to zero. ๐Ÿ™ƒ
  • Back Request (B): This flag MAY be set to one to request that the End Point send a Measurement Request to the Start Point. ๐Ÿซถ
  • Intermediate Reply (I): This flag MUST be set to zero. ๐Ÿงš
  • SeqNo: This is assigned by the Start Point so that it can uniquely identify the Measurement Request and the corresponding Measurement Reply. ๐Ÿ”ฅ
  • Num: This field MUST specify the number of address elements, each (16 - Compr) octets in size, that can fit inside the Address vector. ๐Ÿ“
  • Index: This field MUST be set to zero to indicate the position in the Address vector where the next hop must store its IPv6 address. ๐ŸŒˆ
  • Start Point Address: This field MUST contain the DODAGID value (after eliding Compr number of prefix octets) associated with the route being measured. This DODAGID MUST also be a global or unique-local IPv6 address of the Start Point. ๐Ÿ‘‘
  • End Point Address: This field MUST be set to a unicast global or unique-local IPv6 address of the End Point after eliding Compr number of prefix octets. ๐Ÿ’œ
  • Address vector: The Address vector must be large enough to accommodate a complete Source Route from the End Point to the Start Point. All the bits in the Address vector field MUST be set to zero. ๐Ÿซง

4.4. When Measuring a Source Route ๐Ÿ›ฃ๏ธ

If a Source Route is being measured, the Start Point MUST set various MO fields like so ๐Ÿ’…:

  • RPLInstanceID: This field does not have any significance when a Source Route is being measured and hence can be set to any value. ๐Ÿคทโ€โ™€๏ธ
  • Compr: This field MUST be set to specify the number of prefix octets that are elided from the IPv6 addresses in Start Point/End Point Address fields and the Address vector. ๐ŸŽ€
  • Type (T): This flag MUST be set to one, since the MO represents a Measurement Request. ๐Ÿ’–
  • Hop-by-hop (H): This flag MUST be set to zero. ๐Ÿ™…โ€โ™€๏ธ
  • Accumulate Route (A): This flag MUST be set to zero. ๐Ÿ™ˆ
  • Reverse (R): This flag SHOULD be set to one if the Source Route in the Address vector can be reversed and used by the End Point to send the Measurement Reply message back to the Start Point. Otherwise, this flag MUST be set to zero. ๐Ÿ”„
  • Back Request (B): This flag MAY be set to one to request that the End Point send a Measurement Request to the Start Point. ๐Ÿซถ
  • Intermediate Reply (I): This flag MUST be set to zero. ๐Ÿงš
  • SeqNo: This is assigned by the Start Point so that it can uniquely identify the Measurement Request and the corresponding Measurement Reply. ๐Ÿ”ฅ
  • Num: This field MUST specify the number of address elements, each (16 - Compr) octets in size, inside the Address vector. ๐Ÿ“
  • Index: This field MUST be set to zero to indicate the position in the Address vector of the next hop on the route. ๐ŸŒˆ
  • Start Point Address: This field MUST be set to a unicast global or unique-local IPv6 address of the Start Point after eliding Compr number of prefix octets. ๐Ÿ‘‘
  • End Point Address: This field MUST be set to a unicast global or unique-local IPv6 address of the End Point after eliding Compr number of prefix octets. ๐Ÿ’œ
  • Address vector:
    • The Address vector MUST contain a complete Source Route from the Start Point to the End Point (excluding the Start Point and the End Point). ๐Ÿ—บ๏ธ
    • Each address appearing in the Address vector MUST be a unicast global or unique-local IPv6 address. Further, each address MUST have the same prefix as the Start Point Address and the End Point Address. This prefix, whose length in octets is specified in the Compr field, MUST be elided from each address. โœ‚๏ธ
    • The IPv6 addresses in the Address vector MUST be reachable in the Forward direction. โžก๏ธ
    • If the R flag is set to one, the IPv6 addresses in the Address vector MUST also be reachable in the Reverse direction. โฌ…๏ธ

5. Processing a Measurement Request at an Intermediate Point ๐Ÿงญ

Alright, time for the middle-of-the-network stuff ๐ŸŒท. A router (an Intermediate Point or the End Point) MAY discard a received MO with no processing, in order to meet any policy-related goals. Such policy goals may include the need to reduce the router's CPU load, or to enhance its battery life, or to prevent the misuse of this mechanism by unauthorized nodes. ๐Ÿ”‹

A router MUST discard a received MO with no further processing if the value in the Compr field inside the received message is more than what the router considers to be the length of the common prefix used in IPv6 addresses in the LLN. ๐Ÿšซ

On receiving an MO, if a router chooses to process the packet further, it MUST determine whether or not one of its IPv6 addresses is listed as either the Start Point or the End Point Address. If not, the router considers itself an Intermediate Point and MUST process the received MO in the following manner. ๐Ÿ•ต๏ธโ€โ™€๏ธ

An Intermediate Point MUST discard the packet with no further processing if the received MO is not a Measurement Request (i.e., T = 0). This is because the End Point unicasts a Measurement Reply directly to the Start Point. So, the Intermediate Point treats a transiting Measurement Reply as a data packet and not a RPL control message. ๐Ÿ’€

Next, the Intermediate Point determines the type of the route being measured (by checking the values of the H flag and the RPLInstanceID field) and processes the received MO accordingly, in the manner specified next. ๐Ÿฆ‹โœจ

5.1. When Measuring a Hop-by-Hop Route with a Global RPLInstanceID โœจ

okay bestie, this is the case where we're measuring a hop-by-hop route and the RPLInstanceID is global (so H = 1 and the RPLInstanceID has a global value) ๐ŸŒธ. In this situation the Intermediate Point MUST process the received Measurement Request like this:

If the Num field is not set to zero, which means an Address vector is present, the Intermediate Point MUST discard the received message with no further processing. Nope, not today ๐Ÿ™…โ€โ™€๏ธ

If the Intermediate Reply (I) flag is set to one and the Intermediate Point knows the values of the routing metrics (the ones in the Metric Container options) for the rest of the route, it MAY generate a Measurement Reply on the End Point's behalf, the way Section 6.1 describes. It has to include the relevant routing metric values for the complete route being measured too ๐Ÿ“Š Otherwise, the Intermediate Point MUST process the message like this:

The Intermediate Point MUST determine the next hop on the route being measured using the RPLInstanceID and the End Point Address. If the Intermediate Point is the root of the non-storing global DAG that the Measurement Request has been traveling along so far, it MUST process the request like this:

  • If the router does not know how to reach the End Point, it MUST discard the Measurement Request with no further processing and MAY send an ICMPv6 Destination Unreachable (with Code 0 -- No Route To Destination) error message [RFC4443] to the Start Point. ๐Ÿ’€
  • Otherwise, unless the router determines the End Point itself to be the next hop, the router MUST make the following changes in the received Measurement Request:
    • Set the H, A, R, and I flags to zero (the A and R flags should already be zero in the received message).
    • Leave the remaining fields unchanged (the Num field would be modified in the next steps). The RPLInstanceID field identifies the non-storing global DAG that the Measurement Request traveled along so far, and this information MUST be preserved so that the End Point can use this DAG to send the Measurement Reply back to the Start Point. Main character preservation ๐ŸŽ€
    • Insert a new Address vector inside the Measurement Request, and specify a Source Route to the End Point inside it, following these rules:
      • The Address vector MUST contain a complete route from the router to the End Point (excluding the router and the End Point).
      • Each address in the Address vector MUST be a unicast global or unique-local IPv6 address. Each address MUST also have the same prefix as the Start Point Address and the End Point Address. That prefix, whose length in octets is specified in the Compr field, MUST be elided from each address.
      • The IPv6 addresses in the Address vector MUST be reachable in the Forward direction.

If the router cannot insert an Address vector that satisfies the rules above, it MUST discard the Measurement Request with no further processing and MAY send an ICMPv6 Destination Unreachable (with Code 0 -- No Route To Destination) error message [RFC4443] to the Start Point.

  • Specify in the Num field the number of address elements in the Address vector.
  • Set the Index field to zero to indicate the position in the Address vector of the next hop on the route. So Address[0] holds the address of the next hop on the route ๐Ÿฆ‹

The Intermediate Point MUST then complete the processing of the received Measurement Request as specified in Section 5.5.


5.2. When Measuring a Hop-by-Hop Route with a Local RPLInstanceID with Route Accumulation Off ๐ŸŒท

okay so this one is when we're measuring a hop-by-hop route with a local RPLInstanceID and route accumulation is off (so H = 1, the RPLInstanceID has a local value, and A = 0) ๐Ÿ’… The Intermediate Point MUST process the received Measurement Request like this:

If the Num field is not set to zero, which means an Address vector is present, the Intermediate Point MUST discard the received message with no further processing.

The Intermediate Point MUST then determine the next hop on the route being measured using the RPLInstanceID, the End Point Address, and the Start Point Address (the Start Point Address is the DODAGID of the route being measured ๐Ÿงš). If the Intermediate Point cannot determine the next hop, it MUST discard the Measurement Request with no further processing and MAY send an ICMPv6 Destination Unreachable (with Code 0 -- No Route To Destination) error message [RFC4443] to the Start Point. Otherwise, the Intermediate Point MUST complete the processing of the received Measurement Request as specified in Section 5.5.


5.3. When Measuring a Hop-by-Hop Route with a Local RPLInstanceID with Route Accumulation On ๐ŸŒˆ

this is the same local RPLInstanceID vibe, except route accumulation is on (so H = 1, the RPLInstanceID has a local value, and A = 1) ๐Ÿ”ฅ The Intermediate Point MUST process the received Measurement Request like this:

If the Num field is set to zero, which means an Address vector is not present, the Intermediate Point MUST discard the received message with no further processing.

The Intermediate Point MUST then determine the next hop on the route being measured using the RPLInstanceID, the End Point Address, and the Start Point Address (again, the Start Point Address represents the DODAGID of the route being measured). If the Intermediate Point cannot determine the next hop, it MUST discard the Measurement Request with no further processing and MAY send an ICMPv6 Destination Unreachable (with Code 0 -- No Route To Destination) error message [RFC4443] to the Start Point. If the Index field has the value Num - 1 and the next hop is not the same as the End Point, the Intermediate Point MUST drop the received Measurement Request with no further processing. In that case the next hop would have no space left in the Address vector to store its address ๐Ÿ˜ญ

Otherwise, the router MUST store one of its IPv6 addresses at location Address[Index] and then increment the Index field. The IPv6 address added to the Address vector MUST have these properties:

  • This address MUST be a unicast global or unique-local address.
  • This address MUST have the same prefix as the Start Point Address and the End Point Address. That prefix, whose length in octets is specified in the Compr field, MUST be elided before the address is added to the Address vector.
  • This address MUST be reachable in the Reverse direction.

If the router does not have an IPv6 address that satisfies the properties above, it MUST discard the Measurement Request with no further processing.

The Intermediate Point MUST then complete the processing of the received Measurement Request as specified in Section 5.5.


5.4. When Measuring a Source Route ๐Ÿ“

last one in this group, and it's a Source Route being measured (so H = 0) ๐Ÿง  The Intermediate Point MUST process the received Measurement Request like this:

If the Num field is set to zero, which means an Address vector is not present, the Intermediate Point MUST discard the received message with no further processing.

The Intermediate Point MUST verify that the Address[Index] element lists one of its unicast global or unique-local IPv6 addresses (minus the prefix whose length in octets is specified in the Compr field). If it doesn't, it MUST discard the Measurement Request with no further processing. Then the Intermediate Point MUST increment the Index field and use the Address[Index] element as the next hop (unless the Index value is now Num). If the Index value is now Num, the Intermediate Point MUST use the End Point Address as the next hop.

The Intermediate Point MUST then complete the processing of the received Measurement Request as specified in Section 5.5.


5.5. Final Processing ๐Ÿ’–

this is the last step, and it's where everything gets wrapped up ๐ŸŽ€ The Intermediate Point MUST drop the received Measurement Request with no further processing in any of these cases:

  • if the next-hop address is not a unicast address; or
  • if the next hop is not on-link; or
  • if the next hop is not in the same RPL routing domain as the Intermediate Point.

Next, the Intermediate Point MUST update the routing metric objects inside the Metric Container option(s) in the Measurement Request. It can do that by updating the aggregated value for the routing metric or by attaching the local values for the metric inside the object. An Intermediate Point can only update the existing metric objects and MUST NOT add any new routing metric objects to the Metric Container. If the Intermediate Point cannot update a routing metric object specified inside the Metric Container, it MUST drop the Measurement Request with no further processing.

Finally, the Intermediate Point MUST unicast the Measurement Request to the next hop ๐Ÿฆ‹โœจ

6. Processing a Measurement Request at the End Point โœจ

okay so when an MO shows up, a router can decide to look at it more closely ๐Ÿ‘€. If it finds one of its unicast global or unique-local IPv6 addresses (minus the prefix whose length in octets is specified in the Compr field) listed as the End Point Address, it's officially the End Point ๐Ÿ‘‘, and it MUST process the received MO like this:

The End Point MUST discard the received message with no further processing if it is not a Measurement Request (i.e., T = 0). no cap, that's a hard no ๐Ÿ™…โ€โ™€๏ธ

If the received Measurement Request traveled on a Hop-by-hop Route with a local RPLInstanceID with route accumulation on (i.e., H = 1, RPLInstanceID has a local value, and A = 1), elements Address[0] through Address[Index - 1] in the Address vector contain a complete Source Route from the Start Point to the End Point ๐Ÿ—บ๏ธ. The End Point MAY use that route, after reversal, to reach the Start Point. Note that the Source Route in the Address vector does not include the Start Point and the End Point addresses, and that the individual addresses do not include the common prefix whose length in octets is specified in the Compr field. bestie, read that twice, it matters ๐Ÿซถ

If the received Measurement Request traveled on a Source Route and the Reverse flag is set to one (i.e., H = 0 and R = 1), elements Address[0] through Address[Num - 1] in the Address vector contain a complete Source Route from the Start Point to the End Point ๐Ÿ’…. Again, the Source Route in the Address vector does not include the Start Point and the End Point addresses, and the individual addresses do not include the common prefix whose length in octets is specified in the Compr field. The End Point MAY use that route, after reversal, to reach the Start Point.

The End Point MUST update the routing metric objects in the Metric Container options if required ๐Ÿ“Š and MAY note the measured values for the complete route. This is especially likely when the received Measurement Request is a response to an earlier Measurement Request that the End Point had sent to the Start Point with the B flag set to one ๐Ÿ”.

The End Point MUST generate a Measurement Reply message as specified in Section 6.1 ๐Ÿ’–. If the B flag is set to one in the received Measurement Request, the End Point SHOULD generate a new Measurement Request to measure the cost of its current (or the most preferred) route to the Start Point ๐ŸŒˆ. The routing metrics used in the new Measurement Request MUST include the routing metrics specified in the received Measurement Request. the metrics carry over, no drama ๐Ÿ’œ

6.1. Generating the Measurement Reply ๐Ÿฆ‹

A Measurement Reply MUST have the Type (T) flag set to zero and need not contain the Address vector. The following fields inside a Measurement Reply MUST have the same values as they had inside the corresponding Measurement Request: RPLInstanceID, Compr, SeqNo, Start Point Address, End Point Address, and Metric Container option(s). The remaining fields inside a Measurement Reply may have any value and MUST be ignored on reception at the Start Point ๐Ÿ™ˆ. The received Measurement Request can therefore trivially be converted into a Measurement Reply by setting the Type (T) flag to zero. literally a glow-up with one bit flip โœจ

A Measurement Reply MUST be unicast back to the Start Point:

  • If the Measurement Request traveled along a global DAG, identified by the RPLInstanceID field, the Measurement Reply MAY be unicast back to the Start Point along the same DAG ๐Ÿ“.
  • If the Measurement Request traveled along a Hop-by-hop Route with a local RPLInstanceID and accumulated a Source Route from the Start Point to the End Point, this Source Route MAY be used after reversal to send the Measurement Reply back to the Start Point ๐Ÿงš.
  • If the Measurement Request traveled along a Source Route and the R flag inside the received message is set to one, the End Point MAY reverse the Source Route contained in the Address vector and use it to send the Measurement Reply back to the Start Point ๐Ÿ”„.

7. Processing a Measurement Reply at the Start Point ๐ŸŽ€

When a router receives an MO, it checks whether one of its unicast IPv6 addresses is listed as the Start Point Address. If yes, the router is the Start Point ๐Ÿฅฐ and MUST process the received message in the following manner.

If the Start Point discovers that the received MO is not a Measurement Reply, or if it no longer maintains state for the corresponding Measurement Request, it MUST discard the received message with no further processing ๐Ÿ—‘๏ธ. not the vibe, bestie.

The Start Point can use the routing metric objects inside the Metric Container to evaluate the metrics for the measured P2P route ๐Ÿ“ˆ. If a routing metric object contains local metric values recorded by routers on the route, the Start Point can make use of those local values by aggregating them into an end-to-end metric, according to the aggregation rules for the specific metric. A Start Point is then free to interpret the metrics for the route according to its local policy ๐Ÿง .

8. Security Considerations ๐Ÿ”

okay this section is serious, so let's get into it ๐Ÿ™ˆ.

In general, the security considerations for the route measurement mechanism described in this document are similar to those for RPL (as described in Section 19 of the RPL specification [RFC6550]). Sections 6.1 and 10 of [RFC6550] describe RPL's security framework, which provides data confidentiality, authentication, replay protection, and delay protection services. This security framework is applicable to the route measurement mechanism described here as well, after taking into account the constraints specified in Section 3.2.

This document requires that all routers participating in a secure invocation of the route measurement process use the Security Configuration chosen by the Start Point. The intention is to avoid compromising the overall security of the route measurement due to some routers using a weaker Security Configuration. A router is allowed to participate in a "secure" route measurement only if it can support the Security Configuration in use, which also specifies the key in use. It does not matter whether the key is preinstalled or dynamically acquired after proper authentication. The router must have the key in use before it can process or generate Secure MO messages. Hence, from the perspective of the route measurement mechanism, there is no distinction between the "preinstalled" and "authenticated" security modes described in the RPL specification [RFC6550]. Of course, if a compromised router has the key being used, it could cause the route measurement to fail, or worse, insert wrong information in Secure MO messages ๐Ÿ’€.

A rogue router acting as the Start Point could use the route measurement mechanism defined in this document to measure routes from itself to other routers and thus find out key information about the LLN, e.g., the topological features of the LLN (such as the identity of the key routers in the topology) or the remaining energy levels [RFC6551] in the routers. This information can potentially be used to attack the LLN ๐Ÿ˜ฑ. A rogue router could also use this mechanism to send bogus Measurement Requests to arbitrary End Points. If sufficient Measurement Requests are sent, then it may cause CPU overload in the routers in the network, drain their batteries, and cause traffic congestion in the network ๐Ÿ”‹. Note that some of these problems would occur even if the compromised router were to generate bogus data traffic to arbitrary destinations.

To protect against such misuse, this document allows RPL routers implementing this mechanism to not process MO messages (or process such messages selectively), based on a local policy. For example, an LLN deployment might require the use of Secure MO messages generated using a key that could be obtained only after proper authentication ๐Ÿ”‘. Note that this document requires that an LLN deployment support Secure MO messages so that such policies can be enforced where considered essential.

Since a Measurement Request can travel along a Source Route specified in the Address vector, some of the security concerns that led to the deprecation of Type 0 routing headers [RFC5095] may be valid here. To address such concerns, the mechanism described in this document includes several remedies, in the form of the following requirements:

  • A route inserted inside the Address vector must be a strict Source Route and must not include any multicast addresses.
  • An MO message must not cross the boundaries of the RPL routing domain where it originated. A router must not forward a received MO message further if the next hop belongs to a different RPL routing domain. Hence, any security problems associated with the mechanism would be limited to one RPL routing domain ๐Ÿšง.
  • A router must drop a received Measurement Request if the next-hop address is not on-link or if it is not a unicast address.

9. IANA Considerations ๐ŸŒธ

This document defines two new RPL messages:

  • "Measurement Object" (see Section 3.1), assigned a value of 0x06 from the "RPL Control Codes" space [RFC6550].
  • "Secure Measurement Object" (see Section 3.2), assigned a value of 0x86 from the "RPL Control Codes" space [RFC6550].
+------+---------------------------+---------------+
| Code |        Description        |   Reference   |
+------+---------------------------+---------------+
| 0x06 |     Measurement Object    | This document |
| 0x86 | Secure Measurement Object | This document |
+------+---------------------------+---------------+

                 RPL Control Codes

10. Acknowledgements ๐Ÿซถ

the authors gratefully acknowledge the contributions of Ralph Droms, Adrian Farrel, Joel Halpern, Matthias Philipp, Pascal Thubert, Richard Kelsey, and Zach Shelby in the development of this document ๐Ÿ’œโœจ.

11. References ๐Ÿ“š

11.1. Normative References

[RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
           Requirement Levels", BCP 14, RFC 2119, March 1997.

[RFC4443]  Conta, A., Deering, S., and M. Gupta, "Internet Control
           Message Protocol (ICMPv6) for the Internet Protocol
           Version 6 (IPv6) Specification", RFC 4443, March 2006.

[RFC6550]  Winter, T., Thubert, P., Brandt, A., Hui, J., Kelsey, R.,
           Levis, P., Pister, K., Struik, R., Vasseur, JP., and R.
           Alexander, "RPL: IPv6 Routing Protocol for Low-Power and
           Lossy Networks", RFC 6550, March 2012.

[RFC6554]  Hui, J., Vasseur, JP., Culler, D., and V. Manral, "An IPv6
           Routing Header for Source Routes with the Routing Protocol
           for Low-Power and Lossy Networks (RPL)", RFC 6554,
           March 2012.

[RFC6997]  Goyal, M., Ed., Baccelli, E., Philipp, M., Brandt, A., and
           J. Martocci, "Reactive Discovery of Point-to-Point Routes
           in Low-Power and Lossy Networks", RFC 6997, August 2013.

11.2. Informative References ๐Ÿ“šโœจ

okay so these are the bonus reads ๐Ÿงš they're not required to get the spec, but they're giving background, the kind of stuff that makes you go "oh, THAT'S why" ๐Ÿ’…

[RFC5095]  Abley, J., Savola, P., and G. Neville-Neil, "Deprecation
           of Type 0 Routing Headers in IPv6", RFC 5095,
           December 2007.

[RFC5826]  Brandt, A., Buron, J., and G. Porcu, "Home Automation
           Routing Requirements in Low-Power and Lossy Networks",
           RFC 5826, April 2010.

[RFC5867]  Martocci, J., De Mil, P., Riou, N., and W. Vermeylen,
           "Building Automation Routing Requirements in Low-Power and
           Lossy Networks", RFC 5867, June 2010.

[RFC6551]  Vasseur, JP., Kim, M., Pister, K., Dejean, N., and D.
           Barthel, "Routing Metrics Used for Path Calculation in
           Low-Power and Lossy Networks", RFC 6551, March 2012.

[ROLL-TERMS]
           Vasseur, JP., "Terminology in Low power And Lossy
           Networks", Work in Progress, March 2013.

Authors' Addresses ๐ŸŽ€

meet the squad ๐Ÿซถ these are the people who built this whole thing, so if you ever want to ask them something, here's where to find them ๐Ÿ’Œ

Mukul Goyal (editor)
University of Wisconsin Milwaukee
3200 N. Cramer St.
Milwaukee, WI  53201
USA

Phone: +1-414-229-5001
EMail: mukul@uwm.edu


Emmanuel Baccelli
INRIA

Phone: +33-169-335-511
EMail: Emmanuel.Baccelli@inria.fr
URI:   http://www.emmanuelbaccelli.org/


Anders Brandt
Sigma Designs
Emdrupvej 26A, 1.
Copenhagen, Dk-2100
Denmark

Phone: +45-29609501
EMail: abr@sdesigns.dk


Jerald Martocci
Johnson Controls
507 E. Michigan Street
Milwaukee, WI  53202
USA

Phone: +1-414-524-4010
EMail: jerald.p.martocci@jci.com