RFC 4836
Definitions of Managed Objects for IEEE 802.3 Medium Attachment Units (MAUs)
Definitions of Managed Objects for IEEE 802.3 Medium Attachment Units (MAUs) 🎀
Part 1 of 13 💖
Okay bestie, this is RFC 4836, and it's giving main character energy ✨. It's a Standards Track document from the IETF, written by E. Beili of Actelis Networks, dated April 2007. It obsoletes RFC 3636, so if you see 3636 in the wild, it's the old version and this is the glow-up 💅. Its job is to define managed objects for IEEE 802.3 Medium Attachment Units (MAUs), which are the bits of Ethernet hardware that network managers poke at.
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. The Internet-Standard Management Framework . . . . . . . . . . 3
3. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.1. Relationship to RFC 3636 . . . . . . . . . . . . . . . . . 4
3.2. Relationship to Other MIBs . . . . . . . . . . . . . . . . 5
3.2.1. Relationship to the Interfaces MIB . . . . . . . . . . 5
3.2.2. Relationship to the 802.3 Repeater MIB Module . . . . 6
3.3. Management of Internal MAUs . . . . . . . . . . . . . . . 6
3.4. Mapping of IEEE 802.3 Managed Objects . . . . . . . . . . 6
3.5. Addition of New MAU Types . . . . . . . . . . . . . . . . 9
3.5.1. dot3MauType OBJECT-IDENTITIES . . . . . . . . . . . . 9
3.5.2. IANAifMauTypeListBits TEXTUAL-CONVENTION . . . . . . . 9
3.5.3. IANAifMauMediaAvailable TEXTUAL-CONVENTION . . . . . . 9
3.5.4. IANAifMauAutoNegCapBits TEXTUAL-CONVENTION . . . . . . 10
3.5.5. JackType TEXTUAL-CONVENTION . . . . . . . . . . . . . 10
4. MAU MIB Definitions . . . . . . . . . . . . . . . . . . . . . 10
5. IANA-Maintained MAU TC Definitions . . . . . . . . . . . . . . 46
6. Security Considerations . . . . . . . . . . . . . . . . . . . 62
7. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 63
8. Acknowledgments . . . . . . . . . . . . . . . . . . . . . . . 63
9. References . . . . . . . . . . . . . . . . . . . . . . . . . . 64
9.1. Normative References . . . . . . . . . . . . . . . . . . . 64
9.2. Informative References . . . . . . . . . . . . . . . . . . 66
Status of This Memo ✨
This is an Internet standards track protocol for the Internet community, and the authors are asking for discussion and suggestions for improvements 🫶. To find out where this protocol stands in standardization, check the current edition of the "Internet Official Protocol Standards" (STD 1). Distribution of this memo is unlimited.
Copyright Notice 🌸
Copyright (C) The IETF Trust (2007).
Abstract 🦋
Okay so the whole point here is defining a slice of the Management Information Base (MIB), which is the thing network management protocols use to see what's going on, and this slice is all about IEEE 802.3 Medium Attachment Units (MAUs) 🔥. This document obsoletes RFC 3636. It's an update that moves MAU type OBJECT-IDENTITY definitions and the relevant textual conventions out into a separate MIB module maintained by the Internet Assigned Number Authority (IANA), which is so smart because it means fewer edits to the main module 💅. On top of that, it adds management information for Ethernet in the First Mile (EFM) and 10GBASE-CX4 MAUs, so it's giving full coverage 🌈.
Table of Contents 💜
The table of contents is copied over exactly as it appears in the original, page numbers and all:
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. The Internet-Standard Management Framework . . . . . . . . . . 3
3. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.1. Relationship to RFC 3636 . . . . . . . . . . . . . . . . . 4
3.2. Relationship to Other MIBs . . . . . . . . . . . . . . . . 5
3.2.1. Relationship to the Interfaces MIB . . . . . . . . . . 5
3.2.2. Relationship to the 802.3 Repeater MIB Module . . . . 6
3.3. Management of Internal MAUs . . . . . . . . . . . . . . . 6
3.4. Mapping of IEEE 802.3 Managed Objects . . . . . . . . . . 6
3.5. Addition of New MAU Types . . . . . . . . . . . . . . . . 9
3.5.1. dot3MauType OBJECT-IDENTITIES . . . . . . . . . . . . 9
3.5.2. IANAifMauTypeListBits TEXTUAL-CONVENTION . . . . . . . 9
3.5.3. IANAifMauMediaAvailable TEXTUAL-CONVENTION . . . . . . 9
3.5.4. IANAifMauAutoNegCapBits TEXTUAL-CONVENTION . . . . . . 10
3.5.5. JackType TEXTUAL-CONVENTION . . . . . . . . . . . . . 10
4. MAU MIB Definitions . . . . . . . . . . . . . . . . . . . . . 10
5. IANA-Maintained MAU TC Definitions . . . . . . . . . . . . . . 46
6. Security Considerations . . . . . . . . . . . . . . . . . . . 62
7. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 63
8. Acknowledgments . . . . . . . . . . . . . . . . . . . . . . . 63
9. References . . . . . . . . . . . . . . . . . . . . . . . . . . 64
9.1. Normative References . . . . . . . . . . . . . . . . . . . 64
9.2. Informative References . . . . . . . . . . . . . . . . . . 66
1. Introduction ✨
So this doc is about the same MIB stuff as before, specifically objects for managing IEEE 802.3 [IEEE802.3] Medium Attachment Units (MAUs) 💖.
The previous version, RFC 3636 [RFC3636], had one single MIB module. This document splits that into two. The frequently updated object identities and textual conventions now live in their own IANA-maintained MIB module, which means the basic MAU MIB module doesn't need constant updating 🧚.
The first version of that IANA-maintained module also extends the list of managed objects so it can support Ethernet in the First Mile (EFM) and 10GBASE-CX4 interfaces 🌸.
Ethernet keeps evolving under the IEEE 802.3 Working Group, with faster speeds, new cabling and interfaces, and new features popping up all the time 🚀. That evolution might mean the managed objects need to change to match the new stuff. This document is a snapshot of Ethernet at one stage of its evolution, the same as the other documents from this working group. Later on, this document might get revised, or the Ethernet Interfaces and Hub MIB Working Group might issue new documents to keep up with Ethernet 💅.
2. The Internet-Standard Management Framework 🎀
For a detailed overview of the documents describing the current Internet-Standard Management Framework, check out section 7 of RFC 3410 [RFC3410] 📚.
Managed objects are accessed through a virtual information store called the Management Information Base, or MIB. Usually you reach MIB objects through the Simple Network Management Protocol (SNMP) 🫧. The objects in the MIB are defined using the mechanisms in the Structure of Management Information (SMI). This memo specifies a MIB module that's compliant with SMIv2, which is described in STD 58, RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580 [RFC2580] 💜.
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in RFC 2119 [RFC2119]. These are the official requirement words, so when you see them in caps, they're doing serious work 🔥.
3. Overview 🦋
Instances of these object types represent attributes of an IEEE 802.3 MAU. The IEEE 802.3 CSMA/CD standard [IEEE802.3] defines several types of MAUs. These MAUs may be connected to IEEE 802.3 repeaters or to 802.3 (Ethernet-like) interfaces. For convenience, this document calls these devices "repeater MAUs" and "interface MAUs" 🍓.
The definitions here are based on three parts of IEEE Std. 802.3-2005 [IEEE802.3]: Section 30.5, "Layer Management for 10 Mb/s, 100 Mb/s, 1000 Mb/s, and 10 Gb/s Medium Attachment Units (MAUs)", Section 30.6, "Management for link Auto-Negotiation", and Annex 30A, "GDMO Specifications for 802.3 managed object classes". The goal is to cover management of all types of Ethernet/802.3 MAUs 🌈.
3.1. Relationship to RFC 3636 💅
The management definitions in this document are meant to be a superset of the ones defined in RFC 3636 [RFC3636] ✨.
To avoid having to update the basic MAU MIB module every time there's a new MAU type, Media Available state, Auto-Negotiation capability, or Jack type, all the relevant object identities and textual conventions were moved to a separate, IANA-maintained MIB module called IANA-MAU-MIB. The first version of that module is defined in this document. So when the IEEE 802.3 working group defines a new MAU type, Media Available state, Auto-Negotiation capability, or Jack type, only the IANA-maintained module needs revising, and the basic MAU-MIB module stays unchanged 🫶.
On top of that, the new definitions go into the IANA-maintained MIB module to support Ethernet in the First Mile (EFM) and 10GBASE-CX4 interfaces. Those are defined in IEEE Std 802.3ah-2004 [IEEE802.3ah] and IEEE Std 802.3ak-2004 [IEEE802.3ak], and they're now part of IEEE Std 802.3-2005 [IEEE802.3] 🎀.
Now, heads up, this one's a bit of a plot twist 👀. The changes in this revision won't be entirely backward-compatible with MIB modules that currently import MAU type object identity descriptors from the MAU-MIB. Those modules will need to be revised to import the DESCRIPTORS from the IANA-MAU-MIB instead. Management applications that process the object identity definitions (for example, to show the DESCRIPTION text to a user) will also need to get those definitions from the IANA-MAU-MIB instead of the MAU-MIB. It's true that changes needing these adjustments aren't strictly compliant with the SMIv2 rules for MIB module revisions (see [RFC2578] Section 10). But in this case, the continued high maintenance costs of not making these changes make the deviation from the rules justified 💖. The working group also said it couldn't find any MIB modules or management applications that would actually be negatively affected by the changes, so phew 😭.
3.2. Relationship to Other MIBs 🧚
It's assumed that an agent implementing MAU-MIB will also implement (at least) the 'system' group defined in the SNMPv2 MIB [RFC3418]. The following sections identify other MIBs that such an agent should implement 🌸.
3.2.1. Relationship to the Interfaces MIB 🫧
The sections of this document that define interface MAU-related objects specify an extension to the Interfaces MIB [RFC2863]. An agent implementing these interface-MAU related objects MUST also implement the relevant groups of the ifCompliance3 MODULE-COMPLIANCE statement of the Interface MIB. The value of the object ifMauIfIndex is the same as the value of 'ifIndex' used to instantiate the interface the MAU is connected to 💜.
It is REQUIRED that an agent implementing the interface-MAU related objects in the MAU-MIB also fully comply with the dot3Compliance2 MODULE-COMPLIANCE statement of the Ethernet-like Interfaces MIB, [RFC3635]. Furthermore, when the interface-MAU related objects are used to manage a 10GBASE-W PHY (that is, when ifMauType equals dot3MauType10GigBaseW or any other 10GBASE-W variant), then the agent MUST also support the Ethernet WAN Interface Sublayer (WIS) MIB [RFC3637] and must follow the interface layering model specified there. In that case, the value of the object ifMauIfIndex is the same as the value of 'ifIndex' for the layer at the top of the stack, which is the ifTable entry whose ifType equals ethernetCsmacd(6). 🔥
If the interface-MAU related objects are used to manage a PHY that lets the MAU type change dynamically, then the agent SHALL create ifTable, ifStackTable, and ifInvStackTable entries that pertain to the WIS. It does this when ifMauDefaultType is changed to a 10GBASE-W variant (that is, one of dot3MauType10GigBaseW, dot3MauType10GigBaseEW, dot3MauType10GigBaseLW, or dot3MauType10GigBaseSW) from any other type. It shall destroy the WIS-related entries when ifMauDefaultType is changed to a non-10GBASE-W type. The agent SHALL also change the values of 'ifConnectorPresent' and 'ifHighSpeed' in the ifTable entry indexed by ifMauIfIndex, as specified in [RFC3635] and [RFC3637], when ifMauDefaultType is manipulated this way. But the agent SHALL NOT otherwise alter that entry 🦋.
(Note that repeater ports are not represented as interfaces in the Interface MIB. 🙈)
3.2.2. Relationship to the 802.3 Repeater MIB Module 🍓
The section of this document that defines repeater MAU-related objects specifies an extension to the 802.3 Repeater MIB defined in [RFC2108]. An agent implementing these repeater-MAU related objects MUST also comply with the snmpRptrModCompl compliance statement of the 802.3 Repeater MIB module 💖.
The values of rpMauGroupIndex and rpMauPortIndex used to instantiate a repeater MAU variable SHALL be the same as the values of rptrPortGroupIndex and rptrPortIndex used to instantiate the port that the given MAU is connected to ✨.
3.3. Management of Internal MAUs 🧚
okay so sometimes a MAU is "internal" 👀 which just means all of its functionality lives inside one device. like, a managed repeater might have an internal repeater-MAU and/or an internal interface-MAU, and the management messages coming in through one of the repeater's external ports go through those so they can reach the management agent for the repeater 💅 these internal MAUs may or may not be managed. if they ARE managed, their attribute objects should show up in the right MIB subtree: dot3RpMauBasicGroup for internal repeater-MAUs and dot3IfMauBasicGroup for internal interface-MAUs 🫶
3.4. Mapping of IEEE 802.3 Managed Objects 📋
this section is the ultimate cheat sheet ✨ it maps the relevant managed objects (attributes) defined in [IEEE802.3] Clause 30 to the managed objects defined in this document 🦋
+----------------------------------+--------------------------------+
| IEEE 802.3 Managed Object | Corresponding SNMP Object |
+----------------------------------+--------------------------------+
| oMAU | |
+----------------------------------+--------------------------------+
| .aMAUID | rpMauIndex or ifMauIndex or |
| | broadMauIndex |
+----------------------------------+--------------------------------+
| .aMAUType | rpMauType or ifMauType |
+----------------------------------+--------------------------------+
| .aMAUTypeList | ifMauTypeListBits |
+----------------------------------+--------------------------------+
| .aMediaAvailable | rpMauMediaAvailable or |
| | ifMauMediaAvailable |
+----------------------------------+--------------------------------+
| .aLoseMediaCounter | rpMauMediaAvailableStateExits |
| | or |
| | ifMauMediaAvailableStateExits |
+----------------------------------+--------------------------------+
| .aJabber | rpMauJabberState and |
| | rpMauJabberingStateEnters or |
| | ifMauJabberState and |
| | ifMauJabberingStateEnters |
+----------------------------------+--------------------------------+
| .aMAUAdminState | rpMauStatus or ifMauStatus |
+----------------------------------+--------------------------------+
| .aBbMAUXmitRcvSplitType | broadMauXmtRcvSplitType |
+----------------------------------+--------------------------------+
| .aBroadbandFrequencies | broadMauXmtCarrierFreq and |
| | broadMauTranslationFreq |
+----------------------------------+--------------------------------+
| .aFalseCarriers | rpMauFalseCarriers or |
| | ifMauFalseCarriers |
+----------------------------------+--------------------------------+
| .acResetMAU | rpMauStatus or ifMauStatus |
+----------------------------------+--------------------------------+
| .acMAUAdminControl | rpMauStatus or ifMauStatus |
+----------------------------------+--------------------------------+
| .nJabber | rpMauJabberTrap or |
| | ifMauJabberTrap |
+----------------------------------+--------------------------------+
| oAutoNegotiation | |
+----------------------------------+--------------------------------+
| .aAutoNegID | ifMauIndex |
+----------------------------------+--------------------------------+
| .aAutoNegAdminState | ifMauAutoNegAdminStatus |
+----------------------------------+--------------------------------+
| .aAutoNegRemoteSignalling | ifMauAutoNegRemoteSignalling |
| .aAutoNegAutoConfig | ifMauAutoNegConfig |
+----------------------------------+--------------------------------+
| .aAutoNegLocalTechnologyAbility | ifMauAutoNegCapabilityBits |
+----------------------------------+--------------------------------+
| .aAutoNegAdvertisedTechnologyAbi | ifMauAutoNegAdvertisedBits and |
| lity | ifMauAutoNegRemoteFaultAdverti |
| | sed |
+----------------------------------+--------------------------------+
| .aAutoNegReceivedTechnologyAbili | ifMauAutoNegReceivedBits and |
| ty | ifMauAutoNegRemoteFaultReceive |
| | d |
+----------------------------------+--------------------------------+
| .acAutoNegRestartAutoConfig | ifMauAutoNegRestart |
+----------------------------------+--------------------------------+
| .acAutoNegAdminControl | ifMauAutoNegAdminStatus |
+----------------------------------+--------------------------------+
Table 1: Mapping of IEEE 802.3 Managed Objects
the following IEEE 802.3 managed objects did NOT make it into the MAU-MIB, and here's why 😭
+------------------------------------+------------------------------+
| IEEE 802.3 Managed Object | Reason for exclusion |
+------------------------------------+------------------------------+
| oMAU | |
+------------------------------------+------------------------------+
| .aIdleErrorCount | Only useful for 100BaseT2, |
| | which is not widely |
| | implemented. |
+------------------------------------+------------------------------+
| oAutoNegotiation | |
+------------------------------------+------------------------------+
| .aAutoNegLocalSelectorAbility | Only needed for support of |
| | isoethernet (802.9a), which |
| | is not supported by MAU-MIB. |
+------------------------------------+------------------------------+
| .aAutoNegAdvertisedSelectorAbility | |
+------------------------------------+------------------------------+
| .aAutoNegReceivedSelectorAbility | |
+------------------------------------+------------------------------+
Table 2: Unmapped IEEE 802.3 Managed Objects
3.5. Addition of New MAU Types 🌈
3.5.1. dot3MauType OBJECT-IDENTITIES
the dot3MauType OBJECT IDENTIFIER and its OBJECT-IDENTITY definitions have moved out of the MAU-MIB and into the IANA-maintained IANA-MAU-MIB 🎀 the first version of that one is defined in this document.
when a brand new IEEE 802.3 MAU gets defined, IANA can re-issue a version of IANA-MAU-MIB with the new dot3MauType OBJECT-IDENTITY, its matching IANAifMauTypeListBits textual convention value and, possibly, new IANAifMauMediaAvailable, IANAifMauAutoNegCapBits, and/or IANAifJackType values 🦋
An Expert Review, as defined in RFC 2434 [RFC2434], is REQUIRED for the addition of the new MAU, Media Available states, Auto Negotiation capabilities, and/or Jack types 💅
in some cases, new MAU types may need extra managed objects or may have side effects on how the existing managed objects behave 👀 in those cases a standards-track specification (which may be a new document or a revision of this document) is also REQUIRED. any such document is REQUIRED to note any special properties of the MAU types it defines, like side effects on the ifStackTable (as this document notes for 10GBASE-W MAUs) 🫶
3.5.2. IANAifMauTypeListBits TEXTUAL-CONVENTION
the syntax of ifMauTypeListBits is now a textual convention 🍓 so the enumerated integer values live in the textual convention IANAifMauTypeListBits. that can be re-specified (with extra values, once IEEE 802.3 defines them) in the IANA-maintained MIB module without issuing a new version of this document 💜
3.5.3. IANAifMauMediaAvailable TEXTUAL-CONVENTION
the syntax of ifMauMediaAvailable and rpMauMediaAvailable is now a textual convention too ✨ the enumerated integer values are defined in IANAifMauMediaAvailable, which can be re-specified (with extra values, once IEEE 802.3 defines them) in the IANA-maintained MIB module without issuing a new version of this document 🌸
3.5.4. IANAifMauAutoNegCapBits TEXTUAL-CONVENTION
the syntax of ifMauAutoNegCapabilityBits, ifMauAutoNegCapAdvertisedBits, and ifMauAutoNegCapReceivedBits is now a textual convention 🧚 the enumerated integer values are defined in IANAifMauAutoNegCapBits, which can be re-specified (with extra values, once IEEE 802.3 defines them) in the IANA-maintained MIB module without issuing a new version of this document 🎀
3.5.5. JackType TEXTUAL-CONVENTION
the JackType Textual Convention has been deprecated in favor of IANAifJackType, which is defined in the IANA-maintained MIB module 🙈 that means new Jack types can be added (once IEEE 802.3 defines them) without issuing a new version of this document 🔥
4. MAU MIB Definitions 💖
the MIB module starts right here, and it's giving full-on definitions 💅
MAU-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter32, Integer32, Counter64,
OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, mib-2
FROM SNMPv2-SMI -- RFC 2578
TruthValue, AutonomousType, TEXTUAL-CONVENTION
FROM SNMPv2-TC -- RFC 2579
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
FROM SNMPv2-CONF -- RFC 2580
InterfaceIndex
FROM IF-MIB -- RFC 2863
IANAifMauTypeListBits, IANAifMauMediaAvailable,
IANAifMauAutoNegCapBits, IANAifJackType
FROM IANA-MAU-MIB
-- http://www.iana.org/assignments/ianamau-mib
;
mauMod MODULE-IDENTITY
LAST-UPDATED "200704210000Z" -- April 21, 2007
ORGANIZATION "IETF Ethernet Interfaces and Hub MIB Working Group"
CONTACT-INFO
"WG charter:
http://www.ietf.org/html.charters/hubmib-charter.html
Mailing Lists:
General Discussion: hubmib@ietf.org
To Subscribe: hubmib-request@ietf.org
In Body: subscribe your_email_address
Chair: Bert Wijnen
Postal: Alcatel-Lucent
Schagen 33
3461 GL Linschoten
Netherlands
Phone: +31-348-407-775
EMail: bwijnen@alcatel-lucent.com
Editor: Edward Beili
Postal: Actelis Networks Inc.
25 Bazel St., P.O.B. 10173
Petach-Tikva 10173
Israel
Tel: +972-3-924-3491
EMail: edward.beili@actelis.com"
DESCRIPTION
"Management information for 802.3 MAUs.
The following reference is used throughout this MIB module:
okay so the MIB module keeps going and it's giving table energy 💅 here's the MODULE-IDENTITY tail, the revision history, and the first chunk of the Basic Repeater MAU Table 🎀
[IEEE802.3] refers to:
IEEE Std 802.3, 2005 Edition: 'IEEE Standard for Information
technology - Telecommunications and information exchange
between systems - Local and metropolitan area networks -
Specific requirements - Part 3: Carrier sense multiple
access with collision detection (CSMA/CD) access method and
physical layer specifications'.
Of particular interest is Clause 30, 'Management'.
Copyright (C) The IETF Trust (2007).
This version of this MIB module is part of RFC 4836;
see the RFC itself for full legal notices."
REVISION "200704210000Z" -- April 21, 2007
DESCRIPTION "Updated to reference IANA maintaned textual
conventions for MAU types, Media Availability state,
Auto Negotiation capabilities, and jack types,
instead of using internally defined values.
This version is published as RFC 4836."
REVISION "200309190000Z" -- September 19, 2003
DESCRIPTION "Updated to include support for 10 Gb/s MAUs.
This resulted in the following revisions:
- Added OBJECT-IDENTITY definitions for
10 gigabit MAU types
- Added fiberLC jack type to JackType TC
- Extended ifMauTypeListBits with bits for
the 10 gigabit MAU types
- Added enumerations to ifMauMediaAvailable,
and updated its DESCRIPTION to reflect
behaviour at 10 Gb/s
- Added 64-bit version of ifMauFalseCarriers
and added mauIfGrpHCStats object group to
contain the new object
- Deprecated mauModIfCompl2 and replaced it
with mauModIfCompl3, which includes the new
object group
This version published as RFC 3636."
REVISION "199908240400Z" -- August 24, 1999
DESCRIPTION "This version published as RFC 2668. Updated
to include support for 1000 Mb/sec
MAUs and flow control negotiation."
REVISION "199710310000Z" -- October 31, 1997
DESCRIPTION "Version published as RFC 2239."
REVISION "199309300000Z" -- September 30, 1993
DESCRIPTION "Initial version, published as RFC 1515."
::= { snmpDot3MauMgt 6 }
snmpDot3MauMgt OBJECT IDENTIFIER ::= { mib-2 26 }
-- Textual Conventions
JackType ::= TEXTUAL-CONVENTION
STATUS deprecated
DESCRIPTION "********* THIS TC IS DEPRECATED **********
This TC has been deprecated in favour of
IANAifJackType.
Common enumeration values for repeater
and interface MAU jack types."
SYNTAX INTEGER {
other(1),
rj45(2),
rj45S(3), -- rj45 shielded
db9(4),
bnc(5),
fAUI(6), -- female aui
mAUI(7), -- male aui
fiberSC(8),
fiberMIC(9),
fiberST(10),
telco(11),
mtrj(12), -- fiber MT-RJ
hssdc(13), -- fiber channel style-2
fiberLC(14)
}
dot3RpMauBasicGroup
OBJECT IDENTIFIER ::= { snmpDot3MauMgt 1 }
dot3IfMauBasicGroup
OBJECT IDENTIFIER ::= { snmpDot3MauMgt 2 }
dot3BroadMauBasicGroup
OBJECT IDENTIFIER ::= { snmpDot3MauMgt 3 }
-- OIDs under the following branch are reserved for
-- the IANA-MAU-MIB to assign as MAU type values:
-- { snmpDot3MauMgt 4 }
dot3IfMauAutoNegGroup
OBJECT IDENTIFIER ::= { snmpDot3MauMgt 5 }
-- the following OID is the MODULE-IDENTITY value
-- for this MIB module: { snmpDot3MauMgt 6 }
--
-- The Basic Repeater MAU Table
--
rpMauTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpMauEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of descriptive and status information
about the MAU(s) attached to the ports of a
repeater."
::= { dot3RpMauBasicGroup 1 }
rpMauEntry OBJECT-TYPE
SYNTAX RpMauEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table, containing information
about a single MAU."
INDEX { rpMauGroupIndex,
rpMauPortIndex,
rpMauIndex
}
::= { rpMauTable 1 }
RpMauEntry ::=
SEQUENCE {
rpMauGroupIndex Integer32,
rpMauPortIndex Integer32,
rpMauIndex Integer32,
rpMauType AutonomousType,
rpMauStatus INTEGER,
rpMauMediaAvailable IANAifMauMediaAvailable,
rpMauMediaAvailableStateExits Counter32,
rpMauJabberState INTEGER,
rpMauJabberingStateEnters Counter32,
rpMauFalseCarriers Counter32
}
rpMauGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION "This variable uniquely identifies the group
containing the port to which the MAU described
by this entry is connected.
Note: In practice, a group will generally be
a field-replaceable unit (i.e., module, card,
or board) that can fit in the physical system
enclosure, and the group number will correspond
to a number marked on the physical enclosure.
The group denoted by a particular value of this
object is the same as the group denoted by the
same value of rptrGroupIndex."
REFERENCE "RFC 2108, rptrGroupIndex."
::= { rpMauEntry 1 }
rpMauPortIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION "This variable uniquely identifies the repeater
port within group rpMauGroupIndex to which the
MAU described by this entry is connected."
REFERENCE "RFC 2108, rptrPortIndex."
::= { rpMauEntry 2 }
rpMauIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION "This variable uniquely identifies the MAU
described by this entry from among other
MAUs connected to the same port
(rpMauPortIndex)."
REFERENCE "[IEEE802.3], 30.5.1.1.1, aMAUID."
::= { rpMauEntry 3 }
rpMauType OBJECT-TYPE
SYNTAX AutonomousType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the MAU type. Values for
standard IEEE 802.3 MAU types are defined in the
IANA maintained IANA-MAU-MIB module, as
OBJECT-IDENTITIES of dot3MauType.
If the MAU type is unknown, the object identifier
zeroDotZero is returned."
REFERENCE "[IEEE802.3], 30.5.1.1.2, aMAUType."
::= { rpMauEntry 4 }
rpMauStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
operational(3),
standby(4),
shutdown(5),
reset(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The current state of the MAU. This object MAY
be implemented as a read-only object by those
agents and MAUs that do not implement software
control of the MAU state. Some agents may not
support setting the value of this object to some
of the enumerated values.
The value other(1) is returned if the MAU is in
a state other than one of the states 2 through
6.
The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized.
A MAU in the operational(3) state is fully
functional; it operates, and passes signals to its
attached DTE or repeater port in accordance to
its specification.
A MAU in standby(4) state forces DI and CI to
idle, and the media transmitter to idle or fault,
if supported. Standby(4) mode only applies to
link type MAUs. The state of
rpMauMediaAvailable is unaffected.
A MAU in shutdown(5) state assumes the same
condition on DI, CI, and the media transmitter,
as though it were powered down or not connected.
The MAU MAY return other(1) value for the
rpMauJabberState and rpMauMediaAvailable objects
when it is in this state. For an AUI, this
state will remove power from the AUI.
Setting this variable to the value reset(6)
resets the MAU in the same manner as a
power-off, power-on cycle of at least one-half
second would. The agent is not required to
return the value reset(6).
Setting this variable to the value
operational(3), standby(4), or shutdown(5)
causes the MAU to assume the respective state,
except that setting a mixing-type MAU or an AUI
to standby(4) will cause the MAU to enter the
shutdown state."
REFERENCE "[IEEE802.3], 30.5.1.1.7, aMAUAdminState,
30.5.1.2.2, acMAUAdminControl, and 30.5.1.2.1,
acResetMAU."
::= { rpMauEntry 5 }
rpMauMediaAvailable OBJECT-TYPE
SYNTAX IANAifMauMediaAvailable
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies Media Available state of
the MAU, complementary to the rpMauStatus. Values
for the standard IEEE 802.3 Media Available states
are defined in the IANA maintained IANA-MAU-MIB
module, as IANAifMauMediaAvailable TC."
REFERENCE "[IEEE802.3], 30.5.1.1.4, aMediaAvailable."
::= { rpMauEntry 6 }
okay bestie, we're deep in the MAU MIB now 🧚💅 rpMauMediaAvailableStateExits is basically a tally of how many times the MAU leaves the available(3) state, and the rptrMonitorPortLastChange thing from RFC 2108 is the tea for when those counts can reset 🫶
rpMauMediaAvailableStateExits OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of the number of times that
rpMauMediaAvailable for this MAU instance leaves
the state available(3).
Discontinuities in the value of this counter can
occur at re-initialization of the management
system and at other times, as indicated by the
value of rptrMonitorPortLastChange."
REFERENCE "[IEEE802.3], 30.5.1.1.5, aLoseMediaCounter.
RFC 2108, rptrMonitorPortLastChange"
::= { rpMauEntry 7 }
rpMauJabberState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
noJabber(3),
jabbering(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value other(1) is returned if the jabber
state is not 2, 3, or 4. The agent MUST always
return other(1) for MAU type dot3MauTypeAUI.
The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized.
If the MAU is not jabbering the agent returns
noJabber(3). This is the 'normal' state.
If the MAU is in jabber state the agent returns
the jabbering(4) value."
REFERENCE "[IEEE802.3], 30.5.1.1.6, aJabber.jabberFlag."
::= { rpMauEntry 8 }
rpMauJabberingStateEnters OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of the number of times that
mauJabberState for this MAU instance enters the
state jabbering(4). For MAUs of type
dot3MauTypeAUI, dot3MauType100BaseT4,
dot3MauType100BaseTX, dot3MauType100BaseFX, and
all 1000Mbps types, this counter will always
indicate zero.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system and at other times, as indicated by the
value of rptrMonitorPortLastChange."
REFERENCE "[IEEE802.3], 30.5.1.1.6, aJabber.jabberCounter.
RFC 2108, rptrMonitorPortLastChange"
::= { rpMauEntry 9 }
rpMauFalseCarriers OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of the number of false carrier events
during IDLE in 100BASE-X links. This counter
does not increment at the symbol rate. It can
increment after a valid carrier completion at a
maximum rate of once per 100 ms until the next
carrier event.
This counter increments only for MAUs of type
dot3MauType100BaseT4, dot3MauType100BaseTX,
dot3MauType100BaseFX, and all 1000Mbps types.
For all other MAU types, this counter will
always indicate zero.
The approximate minimum time for rollover of
this counter is 7.4 hours.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system and at other times, as indicated by the
value of rptrMonitorPortLastChange."
REFERENCE "[IEEE802.3], 30.5.1.1.10, aFalseCarriers.
RFC 2108, rptrMonitorPortLastChange"
::= { rpMauEntry 10 }
-- The rpJackTable applies to MAUs attached to repeaters
-- which have one or more external jacks (connectors).
rpJackTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpJackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Information about the external jacks attached
to MAUs attached to the ports of a repeater."
::= { dot3RpMauBasicGroup 2 }
rpJackEntry OBJECT-TYPE
SYNTAX RpJackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table, containing information
about a particular jack."
INDEX { rpMauGroupIndex,
rpMauPortIndex,
rpMauIndex,
rpJackIndex
}
::= { rpJackTable 1 }
RpJackEntry ::=
SEQUENCE {
rpJackIndex Integer32,
rpJackType IANAifJackType
}
rpJackIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This variable uniquely identifies the jack
described by this entry from among other jacks
attached to the same MAU (rpMauIndex)."
::= { rpJackEntry 1 }
rpJackType OBJECT-TYPE
SYNTAX IANAifJackType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The jack connector type, as it appears on the
outside of the system."
::= { rpJackEntry 2 }
--
-- The Basic Interface MAU Table
--
ifMauTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfMauEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of descriptive and status information
about MAU(s) attached to an interface."
::= { dot3IfMauBasicGroup 1 }
ifMauEntry OBJECT-TYPE
SYNTAX IfMauEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table, containing information
about a single MAU."
INDEX { ifMauIfIndex,
ifMauIndex
}
::= { ifMauTable 1 }
IfMauEntry ::=
SEQUENCE {
ifMauIfIndex InterfaceIndex,
ifMauIndex Integer32,
ifMauType AutonomousType,
ifMauStatus INTEGER,
ifMauMediaAvailable IANAifMauMediaAvailable,
ifMauMediaAvailableStateExits Counter32,
ifMauJabberState INTEGER,
ifMauJabberingStateEnters Counter32,
ifMauFalseCarriers Counter32,
ifMauTypeList Integer32,
ifMauDefaultType AutonomousType,
ifMauAutoNegSupported TruthValue,
ifMauTypeListBits IANAifMauTypeListBits,
ifMauHCFalseCarriers Counter64
}
ifMauIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION "This variable uniquely identifies the interface
to which the MAU described by this entry is
connected."
REFERENCE "RFC 2863, ifIndex"
::= { ifMauEntry 1 }
ifMauIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION "This variable uniquely identifies the MAU
described by this entry from among other MAUs
connected to the same interface (ifMauIfIndex)."
REFERENCE "[IEEE802.3], 30.5.1.1.1, aMAUID."
::= { ifMauEntry 2 }
ifMauType OBJECT-TYPE
SYNTAX AutonomousType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies the MAU type. Values for
standard IEEE 802.3 MAU types are defined in the
IANA maintained IANA-MAU-MIB module, as
OBJECT-IDENTITIES of dot3MauType.
If the MAU type is unknown, the object identifier
zeroDotZero is returned.
This object represents the operational type of
the MAU, as determined by either 1) the result
of the auto-negotiation function or 2) if
auto-negotiation is not enabled or is not
implemented for this MAU, by the value of the
object ifMauDefaultType. In case 2), a set to
the object ifMauDefaultType will force the MAU
into the new operating mode."
REFERENCE "[IEEE802.3], 30.5.1.1.2, aMAUType."
::= { ifMauEntry 3 }
ifMauStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
operational(3),
standby(4),
shutdown(5),
reset(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The current state of the MAU. This object MAY
be implemented as a read-only object by those
agents and MAUs that do not implement software
control of the MAU state. Some agents may not
support setting the value of this object to some
of the enumerated values.
The value other(1) is returned if the MAU is in
a state other than one of the states 2 through
6.
The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized.
A MAU in the operational(3) state is fully
functional; it operates, and passes signals to its
attached DTE or repeater port in accordance to
its specification.
A MAU in standby(4) state forces DI and CI to
idle and the media transmitter to idle or fault,
if supported. Standby(4) mode only applies to
link type MAUs. The state of
ifMauMediaAvailable is unaffected.
A MAU in shutdown(5) state assumes the same
condition on DI, CI, and the media transmitter,
as though it were powered down or not connected.
The MAU MAY return other(1) value for the
ifMauJabberState and ifMauMediaAvailable objects
when it is in this state. For an AUI, this
state will remove power from the AUI.
okay bestie, the MAU knobs keep coming 💅 picking up right where we left off ✨
Setting this variable to the value reset(6)
resets the MAU in the same manner as a
power-off, power-on cycle of at least one-half
second would. The agent is not required to
return the value reset(6).
Setting this variable to the value
operational(3), standby(4), or shutdown(5)
causes the MAU to assume the respective state,
except that setting a mixing-type MAU or an AUI
to standby(4) will cause the MAU to enter the
shutdown state."
REFERENCE "[IEEE802.3], 30.5.1.1.7, aMAUAdminState,
30.5.1.2.2, acMAUAdminControl, and 30.5.1.2.1,
acResetMAU."
::= { ifMauEntry 4 }
ifMauMediaAvailable OBJECT-TYPE
SYNTAX IANAifMauMediaAvailable
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object identifies Media Available state of
the MAU, complementary to the ifMauStatus. Values
for the standard IEEE 802.3 Media Available states
are defined in the IANA maintained IANA-MAU-MIB
module, as IANAifMauMediaAvailable TC."
REFERENCE "[IEEE802.3], 30.5.1.1.4, aMediaAvailable."
::= { ifMauEntry 5 }
ifMauMediaAvailableStateExits OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of the number of times that
ifMauMediaAvailable for this MAU instance leaves
the state available(3).
Discontinuities in the value of this counter can
occur at re-initialization of the management
system and at other times, as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE802.3], 30.5.1.1.5, aLoseMediaCounter.
RFC 2863, ifCounterDiscontinuityTime."
::= { ifMauEntry 6 }
ifMauJabberState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
noJabber(3),
jabbering(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value other(1) is returned if the jabber
state is not 2, 3, or 4. The agent MUST always
return other(1) for MAU type dot3MauTypeAUI.
The value unknown(2) is returned when the MAU's
true state is unknown; for example, when it is
being initialized.
If the MAU is not jabbering the agent returns
noJabber(3). This is the 'normal' state.
If the MAU is in jabber state the agent returns
the jabbering(4) value."
REFERENCE "[IEEE802.3], 30.5.1.1.6, aJabber.jabberFlag."
::= { ifMauEntry 7 }
ifMauJabberingStateEnters OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of the number of times that
mauJabberState for this MAU instance enters the
state jabbering(4). This counter will always
indicate zero for MAUs of type dot3MauTypeAUI
and those of speeds above 10Mbps.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system and at other times, as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE802.3], 30.5.1.1.6, aJabber.jabberCounter.
RFC 2863, ifCounterDiscontinuityTime."
::= { ifMauEntry 8 }
ifMauFalseCarriers OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of the number of false carrier events
during IDLE in 100BASE-X and 1000BASE-X links.
For all other MAU types, this counter will
always indicate zero. This counter does not
increment at the symbol rate.
It can increment after a valid carrier
completion at a maximum rate of once per 100 ms
for 100BASE-X and once per 10us for 1000BASE-X
until the next CarrierEvent.
This counter can roll over very quickly. A
management station is advised to poll the
ifMauHCFalseCarriers instead of this counter in
order to avoid loss of information.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system and at other times, as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE802.3], 30.5.1.1.10, aFalseCarriers.
RFC 2863, ifCounterDiscontinuityTime."
::= { ifMauEntry 9 }
ifMauTypeList OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This object has been deprecated in favour of
ifMauTypeListBits.
A value that uniquely identifies the set of
possible IEEE 802.3 types that the MAU could be.
The value is a sum that initially takes the
value zero. Then, for each type capability of
this MAU, 2 raised to the power noted below is
added to the sum. For example, a MAU that has
the capability to be only 10BASE-T would have a
value of 512 (2**9). In contrast, a MAU that
supports both 10Base-T (full duplex) and
100BASE-TX (full duplex) would have a value of
((2**11) + (2**16)), or 67584.
The powers of 2 assigned to the capabilities are
these:
Power Capability
0 other or unknown
1 AUI
2 10BASE-5
3 FOIRL
4 10BASE-2
5 10BASE-T duplex mode unknown
6 10BASE-FP
7 10BASE-FB
8 10BASE-FL duplex mode unknown
9 10BROAD36
10 10BASE-T half duplex mode
11 10BASE-T full duplex mode
12 10BASE-FL half duplex mode
13 10BASE-FL full duplex mode
14 100BASE-T4
15 100BASE-TX half duplex mode
16 100BASE-TX full duplex mode
17 100BASE-FX half duplex mode
18 100BASE-FX full duplex mode
19 100BASE-T2 half duplex mode
20 100BASE-T2 full duplex mode
If auto-negotiation is present on this MAU, this
object will map to ifMauAutoNegCapability."
::= { ifMauEntry 10 }
ifMauDefaultType OBJECT-TYPE
SYNTAX AutonomousType
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object identifies the default
administrative baseband MAU type to be used in
conjunction with the operational MAU type
denoted by ifMauType.
The set of possible values for this object is
the same as the set defined for the ifMauType
object.
This object represents the
administratively-configured type of the MAU. If
auto-negotiation is not enabled or is not
implemented for this MAU, the value of this
object determines the operational type of the
MAU. In this case, a set to this object will
force the MAU into the specified operating mode.
If auto-negotiation is implemented and enabled
for this MAU, the operational type of the MAU
is determined by auto-negotiation, and the value
of this object denotes the type to which the MAU
will automatically revert if/when
auto-negotiation is later disabled.
NOTE TO IMPLEMENTORS: It may be necessary to
provide for underlying hardware implementations
which do not follow the exact behavior specified
above. In particular, when
ifMauAutoNegAdminStatus transitions from enabled
to disabled, the agent implementation MUST
ensure that the operational type of the MAU (as
reported by ifMauType) correctly transitions to
the value specified by this object, rather than
continuing to operate at the value earlier
determined by the auto-negotiation function."
REFERENCE "[IEEE802.3], 30.5.1.1.1, aMAUID, and 22.2.4.1.4."
::= { ifMauEntry 11 }
ifMauAutoNegSupported OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object indicates whether or not
auto-negotiation is supported on this MAU."
::= { ifMauEntry 12 }
ifMauTypeListBits OBJECT-TYPE
SYNTAX IANAifMauTypeListBits
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value that uniquely identifies the set of
possible IEEE 802.3 types that the MAU could be.
If auto-negotiation is present on this MAU, this
object will map to ifMauAutoNegCapabilityBits.
Note that this MAU may be capable of operating
as a MAU type that is beyond the scope of this
MIB. This is indicated by returning the
bit value bOther in addition to any bit values
for standard capabilities that are listed in the
IANAifMauTypeListBits TC."
::= { ifMauEntry 13 }
ifMauHCFalseCarriers OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of the number of false carrier events
during IDLE in 100BASE-X and 1000BASE-X links.
For all other MAU types, this counter will
always indicate zero. This counter does not
increment at the symbol rate.
Okay bestie, we're picking up right where the ifMauFalseCarriers description left off 🎀 The 64-bit counter is basically the glow-up of the 32-bit one 💖
This counter is a 64-bit version of
ifMauFalseCarriers. Since the 32-bit version of
this counter can roll over very quickly,
management stations are advised to poll the
64-bit version instead, in order to avoid loss
of information.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system and at other times, as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE802.3], 30.5.1.1.10, aFalseCarriers.
RFC 2863, ifCounterDiscontinuityTime."
::= { ifMauEntry 14 }
Next up is the jack table 🔌 It covers MAUs attached to interfaces that have one or more external jacks (connectors). Main character energy for the hardware side 💅
-- The ifJackTable applies to MAUs attached to interfaces
-- which have one or more external jacks (connectors).
ifJackTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfJackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Information about the external jacks attached
to MAUs attached to an interface."
::= { dot3IfMauBasicGroup 2 }
ifJackEntry OBJECT-TYPE
SYNTAX IfJackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table, containing information
about a particular jack."
INDEX { ifMauIfIndex,
ifMauIndex,
ifJackIndex
}
::= { ifJackTable 1 }
IfJackEntry ::=
SEQUENCE {
ifJackIndex Integer32,
ifJackType IANAifJackType
}
ifJackIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This variable uniquely identifies the jack
described by this entry from among other jacks
attached to the same MAU."
::= { ifJackEntry 1 }
ifJackType OBJECT-TYPE
SYNTAX IANAifJackType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The jack connector type, as it appears on the
outside of the system."
::= { ifJackEntry 2 }
Now we're entering the auto-negotiation era 🤝 This is the MAU Auto-Negotiation Table, which holds the config and status stuff for the auto-negotiation function of MAUs attached to interfaces. Fair warning, it's a whole vibe ✨
--
-- The MAU Auto-Negotiation Table
--
ifMauAutoNegTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfMauAutoNegEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Configuration and status objects for the
auto-negotiation function of MAUs attached to
interfaces.
The ifMauAutoNegTable applies to systems in
which auto-negotiation is supported on one or
more MAUs attached to interfaces. Note that if
auto-negotiation is present and enabled, the
ifMauType object reflects the result of the
auto-negotiation function."
::= { dot3IfMauAutoNegGroup 1 }
ifMauAutoNegEntry OBJECT-TYPE
SYNTAX IfMauAutoNegEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table, containing configuration
and status information for the auto-negotiation
function of a particular MAU."
INDEX { ifMauIfIndex,
ifMauIndex
}
::= { ifMauAutoNegTable 1 }
IfMauAutoNegEntry ::=
SEQUENCE {
ifMauAutoNegAdminStatus INTEGER,
ifMauAutoNegRemoteSignaling INTEGER,
ifMauAutoNegConfig INTEGER,
ifMauAutoNegCapability Integer32,
ifMauAutoNegCapAdvertised Integer32,
ifMauAutoNegCapReceived Integer32,
ifMauAutoNegRestart INTEGER,
ifMauAutoNegCapabilityBits IANAifMauAutoNegCapBits,
ifMauAutoNegCapAdvertisedBits IANAifMauAutoNegCapBits,
ifMauAutoNegCapReceivedBits IANAifMauAutoNegCapBits,
ifMauAutoNegRemoteFaultAdvertised INTEGER,
ifMauAutoNegRemoteFaultReceived INTEGER
}
Let's talk about the admin switch 🎚️ Turning it on enables the auto-negotiation signaling ability on the interface. Turning it off is where it gets spicy 🌶️ The interface acts as if it had no auto-negotiation signaling, and the MAU gets forced to whatever ifMauDefaultType says. There's also an implementor note with a serious BCP 14 moment in it, so read it closely 👀
ifMauAutoNegAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Setting this object to enabled(1) will cause
the interface that has the auto-negotiation
signaling ability to be enabled.
If the value of this object is disabled(2) then
the interface will act as it would if it had no
auto-negotiation signaling. Under these
conditions, an IEEE 802.3 MAU will immediately
be forced to the state indicated by the value of
the object ifMauDefaultType.
NOTE TO IMPLEMENTORS: When
ifMauAutoNegAdminStatus transitions from enabled
to disabled, the agent implementation MUST
ensure that the operational type of the MAU (as
reported by ifMauType) correctly transitions to
the value specified by the ifMauDefaultType
object, rather than continuing to operate at the
value earlier determined by the auto-negotiation
function."
REFERENCE "[IEEE802.3], 30.6.1.1.2, aAutoNegAdminState,
and 30.6.1.2.2, acAutoNegAdminControl."
::= { ifMauAutoNegEntry 1 }
Remote signaling is a read-only status flag 📡 It only reads detected(1) if FLP Bursts were received during the previous link negotiation, so it's basically checking whether the other end is also doing auto-negotiation 🫶
ifMauAutoNegRemoteSignaling OBJECT-TYPE
SYNTAX INTEGER {
detected(1),
notdetected(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value indicating whether the remote end of
the link is using auto-negotiation signaling. It
takes the value detected(1) if and only if,
during the previous link negotiation, FLP Bursts
were received."
REFERENCE "[IEEE802.3], 30.6.1.1.3,
aAutoNegRemoteSignaling."
::= { ifMauAutoNegEntry 2 }
ifMauAutoNegConfig OBJECT-TYPE
SYNTAX INTEGER {
other(1),
configuring(2),
complete(3),
disabled(4),
parallelDetectFail(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value indicating the current status of the
auto-negotiation process. The enumeration
parallelDetectFail(5) maps to a failure in
parallel detection as defined in 28.2.3.1 of
[IEEE802.3]."
REFERENCE "[IEEE802.3], 30.6.1.1.4, aAutoNegAutoConfig."
::= { ifMauAutoNegEntry 4 }
Now the deprecated crew 🪦 These objects have all been replaced by their Bits cousins, but they're still in the MIB, so they're still in the story. The capability object uses a sum of powers of 2, which is a fun little math moment 🧮
ifMauAutoNegCapability OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This object has been deprecated in favour of
ifMauAutoNegCapabilityBits.
A value that uniquely identifies the set of
capabilities of the local auto-negotiation
entity. The value is a sum that initially
takes the value zero. Then, for each capability
of this interface, 2 raised to the power noted
below is added to the sum. For example, an
interface that has the capability to support
only 100Base-TX half duplex would have a value
of 32768 (2**15). In contrast, an interface
that supports both 100Base-TX half duplex and
100Base-TX full duplex would have a value of
98304 ((2**15) + (2**16)).
The powers of 2 assigned to the capabilities are
these:
Power Capability
0 other or unknown
(1-9) (reserved)
10 10BASE-T half duplex mode
11 10BASE-T full duplex mode
12 (reserved)
13 (reserved)
14 100BASE-T4
15 100BASE-TX half duplex mode
16 100BASE-TX full duplex mode
17 (reserved)
18 (reserved)
19 100BASE-T2 half duplex mode
20 100BASE-T2 full duplex mode
Note that interfaces that support this MIB may
have capabilities that extend beyond the scope
of this MIB."
REFERENCE "[IEEE802.3], 30.6.1.1.5,
aAutoNegLocalTechnologyAbility."
::= { ifMauAutoNegEntry 5 }
The advertised one is the writable deprecated sibling 📣 Anything not in the capability object can't be enabled, so no sneaking in features 🙅♀️
ifMauAutoNegCapAdvertised OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This object has been deprecated in favour of
ifMauAutoNegCapAdvertisedBits.
A value that uniquely identifies the set of
capabilities advertised by the local
auto-negotiation entity. Refer to
ifMauAutoNegCapability for a description of the
possible values of this object.
Capabilities in this object that are not
available in ifMauAutoNegCapability cannot be
enabled."
REFERENCE "[IEEE802.3], 30.6.1.1.6,
aAutoNegAdvertisedTechnologyAbility."
::= { ifMauAutoNegEntry 6 }
And last but not least, the received capabilities from the remote side 📥 The note here is that the other end might have capabilities beyond what this MIB covers, which is a very mature way to think about it 🌸
ifMauAutoNegCapReceived OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This object has been deprecated in favour of
ifMauAutoNegCapReceivedBits.
A value that uniquely identifies the set of
capabilities received from the remote
auto-negotiation entity. Refer to
ifMauAutoNegCapability for a description of the
possible values of this object.
Note that interfaces that support this MIB may
be attached to remote auto-negotiation entities
that have capabilities beyond the scope of this
MIB."
REFERENCE "[IEEE802.3], 30.6.1.1.7,
aAutoNegReceivedTechnologyAbility."
::= { ifMauAutoNegEntry 7 }
Okay bestie, we're picking up right where the MIB definitions are getting spicy 💅✨ Auto-negotiation controls are next, so let's go 🦋
ifMauAutoNegRestart OBJECT-TYPE
SYNTAX INTEGER {
restart(1),
norestart(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "If the value of this object is set to
restart(1) then this will force auto-negotiation
to begin link renegotiation. If auto-negotiation
signaling is disabled, a write to this object
has no effect.
Setting the value of this object to norestart(2)
has no effect."
REFERENCE "[IEEE802.3], 30.6.1.2.1,
acAutoNegRestartAutoConfig."
::= { ifMauAutoNegEntry 8 }
ifMauAutoNegCapabilityBits OBJECT-TYPE
SYNTAX IANAifMauAutoNegCapBits
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value that uniquely identifies the set of
capabilities of the local auto-negotiation
entity. Note that interfaces that support this
MIB may have capabilities that extend beyond the
scope of this MIB.
Note that the local auto-negotiation entity may
support some capabilities beyond the scope of
this MIB. This is indicated by returning the
bit value bOther in addition to any bit values
for standard capabilities that are listed in the
IANAifMauAutoNegCapBits TC."
REFERENCE "[IEEE802.3], 30.6.1.1.5,
aAutoNegLocalTechnologyAbility."
::= { ifMauAutoNegEntry 9 }
ifMauAutoNegCapAdvertisedBits OBJECT-TYPE
SYNTAX IANAifMauAutoNegCapBits
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A value that uniquely identifies the set of
capabilities advertised by the local
auto-negotiation entity.
Capabilities in this object that are not
available in ifMauAutoNegCapabilityBits cannot
be enabled.
Note that the local auto-negotiation entity may
advertise some capabilities beyond the scope of
this MIB. This is indicated by returning the
bit value bOther in addition to any bit values
for standard capabilities that are listed in the
IANAifMauAutoNegCapBits TC."
REFERENCE "[IEEE802.3], 30.6.1.1.6,
aAutoNegAdvertisedTechnologyAbility."
::= { ifMauAutoNegEntry 10 }
ifMauAutoNegCapReceivedBits OBJECT-TYPE
SYNTAX IANAifMauAutoNegCapBits
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value that uniquely identifies the set of
capabilities received from the remote
auto-negotiation entity.
Note that interfaces that support this MIB may
be attached to remote auto-negotiation entities
that have capabilities beyond the scope of this
MIB. This is indicated by returning the bit
value bOther in addition to any bit values for
standard capabilities that are listed in the
IANAifMauAutoNegCapBits TC."
REFERENCE "[IEEE802.3], 30.6.1.1.7,
aAutoNegReceivedTechnologyAbility."
::= { ifMauAutoNegEntry 11 }
ifMauAutoNegRemoteFaultAdvertised OBJECT-TYPE
SYNTAX INTEGER {
noError(1),
offline(2),
linkFailure(3),
autoNegError(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A value that identifies any local fault
indications that this MAU has detected and will
advertise at the next auto-negotiation
interaction for 1000Mbps MAUs."
REFERENCE "[IEEE802.3], 30.6.1.1.6,
aAutoNegAdvertisedTechnologyAbility."
::= { ifMauAutoNegEntry 12 }
ifMauAutoNegRemoteFaultReceived OBJECT-TYPE
SYNTAX INTEGER {
noError(1),
offline(2),
linkFailure(3),
autoNegError(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value that identifies any fault indications
received from the far end of a link by the
local auto-negotiation entity for 1000Mbps
MAUs."
REFERENCE "[IEEE802.3], 30.6.1.1.7,
aAutoNegReceivedTechnologyAbility."
::= { ifMauAutoNegEntry 13 }
So that's the auto-negotiation crew all wrapped up 🎀 You can restart the negotiation, check what your side can do, what you're advertising, and what the other end sent back, plus the 1000Mbps fault stuff (ngl the fault enums are giving very "noError, offline, linkFailure, autoNegError" energy 💀).
Next up is the broadband table, which is deprecated 🥀 Read the warnings in here, they're not kidding 👀
--
-- The Basic Broadband MAU Table
--
broadMauBasicTable OBJECT-TYPE
SYNTAX SEQUENCE OF BroadMauBasicEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This entire table has been deprecated. There
have been no reported implementations of this
table, and it is unlikely that there ever will
be. IEEE recommends that broadband MAU types
should not be used for new installations.
Table of descriptive and status information
about the broadband MAUs connected to
interfaces."
::= { dot3BroadMauBasicGroup 1 }
broadMauBasicEntry OBJECT-TYPE
SYNTAX BroadMauBasicEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
An entry in the table, containing information
about a single broadband MAU."
INDEX { broadMauIfIndex,
broadMauIndex
}
::= { broadMauBasicTable 1 }
BroadMauBasicEntry ::=
SEQUENCE {
broadMauIfIndex InterfaceIndex,
broadMauIndex Integer32,
broadMauXmtRcvSplitType INTEGER,
broadMauXmtCarrierFreq Integer32,
broadMauTranslationFreq Integer32
}
broadMauIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This variable uniquely identifies the interface
to which the MAU described by this entry is
connected."
REFERENCE "RFC 2863, ifIndex."
::= { broadMauBasicEntry 1 }
broadMauIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This variable uniquely identifies the MAU
connected to interface broadMauIfIndex that is
described by this entry."
REFERENCE "[IEEE802.3], 30.5.1.1.1, aMAUID."
::= { broadMauBasicEntry 2 }
broadMauXmtRcvSplitType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
single(2),
dual(3)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This object indicates the type of frequency
multiplexing/cabling system used to separate the
transmit and receive paths for the 10BROAD36
MAU.
The value other(1) is returned if the split type
is not either single or dual.
The value single(2) indicates a single cable
system. The value dual(3) indicates a dual
cable system, offset normally zero."
REFERENCE "[IEEE802.3], 30.5.1.1.8, aBbMAUXmitRcvSplitType."
::= { broadMauBasicEntry 3 }
broadMauXmtCarrierFreq OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This variable indicates the transmit carrier
frequency of the 10BROAD36 MAU in MHz/4; that
is, in units of 250 kHz."
REFERENCE "[IEEE802.3], 30.5.1.1.9,
aBroadbandFrequencies.xmitCarrierFrequency."
::= { broadMauBasicEntry 4 }
broadMauTranslationFreq OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "********* THIS OBJECT IS DEPRECATED **********
This variable indicates the translation offset
frequency of the 10BROAD36 MAU in MHz/4; that
is, in units of 250 kHz."
REFERENCE "[IEEE802.3], 30.5.1.1.9,
aBroadbandFrequencies.translationFrequency."
::= { broadMauBasicEntry 5 }
Okay so the whole broadband table has been retired 🪦 The original says there have been no reported implementations and it's unlikely there ever will be, and IEEE recommends that broadband MAU types should not be used for new installations. Every object in here is still marked deprecated, so you'll see that label on each one 💜
Last stretch of this part: the traps and the conformance groups 🧚
-- Notifications for use by 802.3 MAUs
snmpDot3MauTraps OBJECT IDENTIFIER ::= { snmpDot3MauMgt 0 }
rpMauJabberTrap NOTIFICATION-TYPE
OBJECTS { rpMauJabberState }
STATUS current
DESCRIPTION "This trap is sent whenever a managed repeater
MAU enters the jabber state.
The agent MUST throttle the generation of
consecutive rpMauJabberTraps so that there is at
least a five-second gap between them."
REFERENCE "[IEEE802.3], 30.5.1.3.1, nJabber notification."
::= { snmpDot3MauTraps 1 }
ifMauJabberTrap NOTIFICATION-TYPE
OBJECTS { ifMauJabberState }
STATUS current
DESCRIPTION "This trap is sent whenever a managed interface
MAU enters the jabber state.
The agent MUST throttle the generation of
consecutive ifMauJabberTraps so that there is at
least a five-second gap between them."
REFERENCE "[IEEE802.3], 30.5.1.3.1, nJabber notification."
::= { snmpDot3MauTraps 2 }
-- Conformance information
mauModConf
OBJECT IDENTIFIER ::= { mauMod 1 }
mauModCompls
OBJECT IDENTIFIER ::= { mauModConf 1 }
mauModObjGrps
OBJECT IDENTIFIER ::= { mauModConf 2 }
mauModNotGrps
OBJECT IDENTIFIER ::= { mauModConf 3 }
Two jabber traps are here, one for repeater MAUs and one for interface MAUs 🚨 Both say the agent MUST throttle them so there's at least a five-second gap between consecutive ones, which is the vibe of a well-behaved agent 🫶 And then the conformance identifiers hang out at the bottom, grouping everything into compliances, object groups, and notification groups 🌈
Okay so we're still deep in the MIB definitions in section 4 🧚 These are the object groups, which bundle objects so devices can say "yep, I support this bit," then the notification groups, and then the compliance statements that spell out what a device has to implement. Lowkey the most organized part of the whole doc 💅
-- Object groups
mauRpGrpBasic OBJECT-GROUP
OBJECTS { rpMauGroupIndex,
rpMauPortIndex,
rpMauIndex,
rpMauType,
rpMauStatus,
rpMauMediaAvailable,
rpMauMediaAvailableStateExits,
rpMauJabberState,
rpMauJabberingStateEnters
}
STATUS current
DESCRIPTION "Basic conformance group for MAUs attached to
repeater ports. This group is also the
conformance specification for RFC 1515
implementations."
::= { mauModObjGrps 1 }
mauRpGrp100Mbs OBJECT-GROUP
OBJECTS { rpMauFalseCarriers }
STATUS current
DESCRIPTION "Conformance group for MAUs attached to
repeater ports with 100 Mb/s or greater
capability."
::= { mauModObjGrps 2 }
mauRpGrpJack OBJECT-GROUP
OBJECTS { rpJackType }
STATUS current
DESCRIPTION "Conformance group for MAUs attached to
repeater ports with managed jacks."
::= { mauModObjGrps 3 }
mauIfGrpBasic OBJECT-GROUP
OBJECTS { ifMauIfIndex,
ifMauIndex,
ifMauType,
ifMauStatus,
ifMauMediaAvailable,
ifMauMediaAvailableStateExits,
ifMauJabberState,
ifMauJabberingStateEnters
}
STATUS current
DESCRIPTION "Basic conformance group for MAUs attached to
interfaces. This group also provides a
conformance specification for RFC 1515
implementations."
::= { mauModObjGrps 4 }
mauIfGrp100Mbs OBJECT-GROUP
OBJECTS { ifMauFalseCarriers,
ifMauTypeList,
ifMauDefaultType,
ifMauAutoNegSupported
}
STATUS deprecated
DESCRIPTION "********* THIS GROUP IS DEPRECATED **********
Conformance group for MAUs attached to
interfaces with 100 Mb/s capability.
This object group has been deprecated in favor
of mauIfGrpHighCapacity."
::= { mauModObjGrps 5 }
mauIfGrpJack OBJECT-GROUP
OBJECTS { ifJackType }
STATUS current
DESCRIPTION "Conformance group for MAUs attached to
interfaces with managed jacks."
::= { mauModObjGrps 6 }
mauIfGrpAutoNeg OBJECT-GROUP
OBJECTS { ifMauAutoNegAdminStatus,
ifMauAutoNegRemoteSignaling,
ifMauAutoNegConfig,
ifMauAutoNegCapability,
ifMauAutoNegCapAdvertised,
ifMauAutoNegCapReceived,
ifMauAutoNegRestart
}
STATUS deprecated
DESCRIPTION "********* THIS GROUP IS DEPRECATED **********
Conformance group for MAUs attached to
interfaces with managed auto-negotiation.
This object group has been deprecated in favor
of mauIfGrpAutoNeg2."
::= { mauModObjGrps 7 }
mauBroadBasic OBJECT-GROUP
OBJECTS { broadMauIfIndex,
broadMauIndex,
broadMauXmtRcvSplitType,
broadMauXmtCarrierFreq,
broadMauTranslationFreq
}
STATUS deprecated
DESCRIPTION "********* THIS GROUP IS DEPRECATED **********
Conformance group for broadband MAUs attached
to interfaces.
This object group is deprecated. There have
been no reported implementations of this group,
and it was felt to be unlikely that there will
be any future implementations."
::= { mauModObjGrps 8 }
mauIfGrpHighCapacity OBJECT-GROUP
OBJECTS { ifMauFalseCarriers,
ifMauTypeListBits,
ifMauDefaultType,
ifMauAutoNegSupported
}
STATUS current
DESCRIPTION "Conformance group for MAUs attached to
interfaces with 100 Mb/s or greater capability."
::= { mauModObjGrps 9 }
mauIfGrpAutoNeg2 OBJECT-GROUP
OBJECTS { ifMauAutoNegAdminStatus,
ifMauAutoNegRemoteSignaling,
ifMauAutoNegConfig,
ifMauAutoNegCapabilityBits,
ifMauAutoNegCapAdvertisedBits,
ifMauAutoNegCapReceivedBits,
ifMauAutoNegRestart
}
STATUS current
DESCRIPTION "Conformance group for MAUs attached to
interfaces with managed auto-negotiation."
::= { mauModObjGrps 10 }
mauIfGrpAutoNeg1000Mbps OBJECT-GROUP
OBJECTS { ifMauAutoNegRemoteFaultAdvertised,
ifMauAutoNegRemoteFaultReceived
}
STATUS current
DESCRIPTION "Conformance group for 1000Mbps MAUs attached to
interfaces with managed auto-negotiation."
::= { mauModObjGrps 11 }
mauIfGrpHCStats OBJECT-GROUP
OBJECTS { ifMauHCFalseCarriers }
STATUS current
DESCRIPTION "Conformance for high capacity statistics for
MAUs attached to interfaces."
::= { mauModObjGrps 12 }
-- Notification groups
rpMauNotifications NOTIFICATION-GROUP
NOTIFICATIONS { rpMauJabberTrap }
STATUS current
DESCRIPTION "Notifications for repeater MAUs."
::= { mauModNotGrps 1 }
ifMauNotifications NOTIFICATION-GROUP
NOTIFICATIONS { ifMauJabberTrap }
STATUS current
DESCRIPTION "Notifications for interface MAUs."
::= { mauModNotGrps 2 }
-- Compliances
mauModRpCompl MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "******** THIS COMPLIANCE IS DEPRECATED ********
Compliance for MAUs attached to repeater
ports.
This compliance is deprecated and replaced by
mauModRpCompl2, which corrects an oversight by
allowing rpMauStatus to be implemented
read-only."
MODULE -- this module
MANDATORY-GROUPS { mauRpGrpBasic }
GROUP mauRpGrp100Mbs
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have 100Mb/s or
greater capability."
GROUP mauRpGrpJack
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have one or more
external jacks."
GROUP rpMauNotifications
DESCRIPTION "Implementation of this group is recommended
for MAUs attached to repeater ports."
::= { mauModCompls 1 }
mauModIfCompl MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "******** THIS COMPLIANCE IS DEPRECATED ********
Compliance for MAUs attached to interfaces.
This compliance is deprecated and replaced by
mauModIfCompl2."
MODULE -- this module
MANDATORY-GROUPS { mauIfGrpBasic }
GROUP mauIfGrp100Mbs
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have 100Mb/s
capability."
GROUP mauIfGrpJack
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have one or more
external jacks."
GROUP mauIfGrpAutoNeg
DESCRIPTION "Implementation of this group is mandatory
for MAUs that support managed
auto-negotiation."
GROUP mauBroadBasic
DESCRIPTION "Implementation of this group is mandatory
for broadband MAUs."
GROUP ifMauNotifications
DESCRIPTION "Implementation of this group is recommended
for MAUs attached to interfaces."
::= { mauModCompls 2 }
mauModIfCompl2 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "******** THIS COMPLIANCE IS DEPRECATED ********
Compliance for MAUs attached to interfaces.
This compliance is deprecated and replaced by
mauModIfCompl3."
MODULE -- this module
MANDATORY-GROUPS { mauIfGrpBasic }
GROUP mauIfGrpHighCapacity
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have 100Mb/s
or greater capability."
GROUP mauIfGrpJack
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have one or more
external jacks."
GROUP mauIfGrpAutoNeg2
DESCRIPTION "Implementation of this group is mandatory
for MAUs that support managed
auto-negotiation."
GROUP mauIfGrpAutoNeg1000Mbps
DESCRIPTION "Implementation of this group is mandatory
for MAUs that have 1000Mb/s or greater
capability and support managed
auto-negotiation."
GROUP ifMauNotifications
DESCRIPTION "Implementation of this group is recommended
for MAUs attached to interfaces."
OBJECT ifMauStatus
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
::= { mauModCompls 3 }
mauModRpCompl2 MODULE-COMPLIANCE
STATUS current
DESCRIPTION "Compliance for MAUs attached to repeater
ports.
Note that compliance with this compliance
statement requires compliance with the
snmpRptrModCompl MODULE-COMPLIANCE statement of
the SNMP-REPEATER-MIB (RFC 2108)."
MODULE -- this module
MANDATORY-GROUPS { mauRpGrpBasic }
GROUP mauRpGrp100Mbs
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have 100Mb/s or
greater capability."
GROUP mauRpGrpJack
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have one or more
external jacks."
GROUP rpMauNotifications
DESCRIPTION "Implementation of this group is recommended
for MAUs attached to repeater ports."
OBJECT rpMauStatus
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
::= { mauModCompls 4 }
mauModIfCompl3 MODULE-COMPLIANCE
STATUS current
DESCRIPTION "Compliance for MAUs attached to interfaces.
Note that compliance with this compliance
statement requires compliance with the
ifCompliance3 MODULE-COMPLIANCE statement of the
IF-MIB (RFC 2863) and the dot3Compliance2
MODULE-COMPLIANCE statement of the
EtherLike-MIB (RFC3635)."
MODULE -- this module
MANDATORY-GROUPS { mauIfGrpBasic }
GROUP mauIfGrpHighCapacity
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have 100Mb/s
or greater capability."
GROUP mauIfGrpHCStats
DESCRIPTION "Implementation of this group is mandatory
for MAUs that have 1000Mb/s capacity, and
is recommended for MAUs that have 100Mb/s
capacity."
GROUP mauIfGrpJack
DESCRIPTION "Implementation of this optional group is
recommended for MAUs that have one or more
external jacks."
GROUP mauIfGrpAutoNeg2
DESCRIPTION "Implementation of this group is mandatory
for MAUs that support managed
auto-negotiation."
GROUP mauIfGrpAutoNeg1000Mbps
DESCRIPTION "Implementation of this group is mandatory
for MAUs that have 1000Mb/s or greater
capability and support managed
auto-negotiation."
GROUP ifMauNotifications
DESCRIPTION "Implementation of this group is recommended
for MAUs attached to interfaces."
OBJECT ifMauStatus
MIN-ACCESS read-only
DESCRIPTION "Write access is not required."
::= { mauModCompls 5 }
END
5. IANA-Maintained MAU TC Definitions ✨
Okay, bestie, this bit is where IANA keeps the official lists for the MAU-MIB. Think of it as the master menu of MAU types, media states, auto-neg capabilities and jack types. 💅 Here's the module itself:
IANA-MAU-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-IDENTITY, mib-2
FROM SNMPv2-SMI
TEXTUAL-CONVENTION
FROM SNMPv2-TC
;
ianaMauMIB MODULE-IDENTITY
LAST-UPDATED "200704210000Z" -- April 21, 2007
ORGANIZATION "IANA"
CONTACT-INFO " Internet Assigned Numbers Authority
Postal: ICANN
4676 Admiralty Way, Suite 330
Marina del Rey, CA 90292
Tel: +1-310-823-9358
EMail: iana@iana.org"
DESCRIPTION
"This MIB module defines dot3MauType OBJECT-IDENTITIES and
IANAifMauListBits, IANAifMauMediaAvailable,
IANAifMauAutoNegCapBits, and IANAifJackType
TEXTUAL-CONVENTIONs, specifying enumerated values of the
ifMauTypeListBits, ifMauMediaAvailable / rpMauMediaAvailable,
ifMauAutoNegCapabilityBits / ifMauAutoNegCapAdvertisedBits /
ifMauAutoNegCapReceivedBits and ifJackType / rpJackType objects
respectively, defined in the MAU-MIB.
It is intended that each new MAU type, Media Availability
state, Auto Negotiation capability and/or Jack type defined by
the IEEE 802.3 working group and approved for publication in a
revision of IEEE Std 802.3 will be added to this MIB module,
provided that it is suitable for being managed by the base
objects in the MAU-MIB. An Expert Review, as defined in
RFC 2434 [RFC2434], is REQUIRED for such additions.
The following reference is used throughout this MIB module:
[IEEE802.3] refers to:
IEEE Std 802.3, 2005 Edition: 'IEEE Standard for
Information technology - Telecommunications and information
exchange between systems - Local and metropolitan area
networks - Specific requirements -
Part 3: Carrier sense multiple access with collision
detection (CSMA/CD) access method and physical layer
specifications'.
This reference should be updated as appropriate when new
MAU types, Media Availability states, Auto Negotiation
capabilities, and/or Jack types are added to this MIB module.
Copyright (C) The IETF Trust (2007).
The initial version of this MIB module was published in
RFC 4836; for full legal notices see the RFC itself.
Supplementary information may be available at:
http://www.ietf.org/copyrights/ianamib.html"
REVISION "200704210000Z" -- April 21, 2007
DESCRIPTION "Initial version of this MIB as published in
RFC 4836."
::= { mib-2 154 }
-- Textual Conventions
IANAifMauTypeListBits ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This data type is used as the syntax of the ifMauTypeListBits
object in the (updated) definition of MAU-MIB's ifMauTable.
The most recent version of this textual convention is available
in the online version of this MIB module on the IANA web site.
Requests for new values should be made to IANA via email
(iana@iana.org).
Note that changes in this textual convention SHALL be
synchronized with relevant changes in the dot3MauType
OBJECT-IDENTITIES."
REFERENCE
"[IEEE802.3], Section 30.5.1.1.2"
SYNTAX BITS {
bOther(0), -- other or unknown
bAUI(1), -- AUI
b10base5(2), -- 10BASE-5
bFoirl(3), -- FOIRL
b10base2(4), -- 10BASE-2
b10baseT(5), -- 10BASE-T duplex mode unknown
b10baseFP(6), -- 10BASE-FP
b10baseFB(7), -- 10BASE-FB
b10baseFL(8), -- 10BASE-FL duplex mode unknown
b10broad36(9), -- 10BROAD36
b10baseTHD(10), -- 10BASE-T half duplex mode
b10baseTFD(11), -- 10BASE-T full duplex mode
b10baseFLHD(12), -- 10BASE-FL half duplex mode
b10baseFLFD(13), -- 10BASE-FL full duplex mode
b100baseT4(14), -- 100BASE-T4
b100baseTXHD(15), -- 100BASE-TX half duplex mode
b100baseTXFD(16), -- 100BASE-TX full duplex mode
b100baseFXHD(17), -- 100BASE-FX half duplex mode
b100baseFXFD(18), -- 100BASE-FX full duplex mode
b100baseT2HD(19), -- 100BASE-T2 half duplex mode
b100baseT2FD(20), -- 100BASE-T2 full duplex mode
b1000baseXHD(21), -- 1000BASE-X half duplex mode
b1000baseXFD(22), -- 1000BASE-X full duplex mode
b1000baseLXHD(23), -- 1000BASE-LX half duplex mode
b1000baseLXFD(24), -- 1000BASE-LX full duplex mode
b1000baseSXHD(25), -- 1000BASE-SX half duplex mode
b1000baseSXFD(26), -- 1000BASE-SX full duplex mode
b1000baseCXHD(27), -- 1000BASE-CX half duplex mode
b1000baseCXFD(28), -- 1000BASE-CX full duplex mode
b1000baseTHD(29), -- 1000BASE-T half duplex mode
b1000baseTFD(30), -- 1000BASE-T full duplex mode
b10GbaseX(31), -- 10GBASE-X
b10GbaseLX4(32), -- 10GBASE-LX4
b10GbaseR(33), -- 10GBASE-R
b10GbaseER(34), -- 10GBASE-ER
b10GbaseLR(35), -- 10GBASE-LR
b10GbaseSR(36), -- 10GBASE-SR
b10GbaseW(37), -- 10GBASE-W
b10GbaseEW(38), -- 10GBASE-EW
b10GbaseLW(39), -- 10GBASE-LW
b10GbaseSW(40), -- 10GBASE-SW
-- new since RFC 3636
b10GbaseCX4(41), -- 10GBASE-CX4
b2BaseTL(42), -- 2BASE-TL
b10PassTS(43), -- 10PASS-TS
b100BaseBX10D(44), -- 100BASE-BX10D
b100BaseBX10U(45), -- 100BASE-BX10U
b100BaseLX10(46), -- 100BASE-LX10
b1000BaseBX10D(47), -- 1000BASE-BX10D
b1000BaseBX10U(48), -- 1000BASE-BX10U
b1000BaseLX10(49), -- 1000BASE-LX10
b1000BasePX10D(50), -- 1000BASE-PX10D
b1000BasePX10U(51), -- 1000BASE-PX10U
b1000BasePX20D(52), -- 1000BASE-PX20D
b1000BasePX20U(53) -- 1000BASE-PX20U
}
IANAifMauMediaAvailable ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This data type is used as the syntax of the
ifMauMediaAvailable and rpMauMediaAvailable objects in the
(updated) definition of MAU-MIB's ifMauTable and rpMauTable
respectively.
Possible values are:
other(1) - undefined (not listed below)
unknown(2) - MAU's true state is unknown; e.g.,
during initialization
available(3) - link, light, or loopback is normal
notAvailable(4) - link loss, low light, or no loopback
remoteFault(5) - a fault has been detected at the
remote end of the link. This value
applies to 10BASE-FB, 100BASE-T4 Far
End Fault Indication and non-specified
remote faults from a system running
auto-negotiation
invalidSignal(6) - invalid signal has been received from
the other end of the link, 10BASE-FB
only
remoteJabber(7) - remote fault, due to jabber
remoteLinkLoss(8) - remote fault, due to link loss
remoteTest(9) - remote fault, due to test
offline(10) - offline, Clause 37 Auto-Negotiation
only
autoNegError(11) - Auto-Negotiation Error, Clause 37
Auto-Negotiation only
pmdLinkFault(12) - PMA/PMD receive link fault. In case
of PAF (2BASE-TL / 10PASS-TS PHYs),
all PMEs in the aggregation group have
detected a link fault
wisFrameLoss(13) - WIS loss of frame, 10GBASE-W only
wisSignalLoss(14) - WIS loss of signal, 10GBASE-W only
pcsLinkFault(15) - PCS receive link fault
excessiveBER(16) - PCS Bit Error Ratio monitor
reporting excessive error ratio
dxsLinkFault(17) - DTE XGXS receive link fault, XAUI only
pxsLinkFault(18) - PHY XGXS receive link fault, XAUI only
availableReduced(19) - link normal, reduced bandwidth,
2BASE-TL / 10PASS-TS only
ready(20) - at least one PME in the aggregation
group is detecting handshake tones,
2BASE-TL / 10PASS-TS only
Okay bestie, we're still deep in the IANA-maintained TC zone 💅 and the Media Available status is about to give us a whole personality 🦋 Here's the next chunk, straight from the source 🎀
If the MAU is a 10M b/s link or fiber type (FOIRL, 10BASE-T,
10BASE-F), then this is equivalent to the link test fail
state/low light function. For an AUI, 10BASE2, 10BASE5, or
10BROAD36 MAU, this indicates whether loopback is detected on
the DI circuit. The value of this attribute persists between
packets for MAU types AUI, 10BASE5, 10BASE2, 10BROAD36, and
10BASEFP.
At power-up or following a reset, the Media Available state
will be unknown(2) for AUI, 10BASE5, 10BASE2, 10BROAD36, and
10BASE-FP MAUs. For these MAUs loopback will be tested on each
transmission during which no collision is detected.
If DI is receiving input when DO returns to IDL after a
transmission and there has been no collision during the
transmission, then loopback will be detected. The Media
Available state will only change during noncollided
transmissions for AUI, 10BASE2, 10BASE5, 10BROAD36, and
10BASE-FP MAUs.
For 100BASE-T2, 100BASE-T4, 100BASE-TX, 100BASE-FX,
100BASE-LX10, and 100BASE-BX10 PHYs the enumerations match the
states within the link integrity state diagram.
Any MAU that implements management of [IEEE802.3] Clause
28 Auto-Negotiation, will map remote fault indication to
remoteFault(5).
Any MAU that implements management of Clause 37
Auto-Negotiation, will map the received RF1 and RF2 bits as
follows: Offline maps to offline(10), Link_Failure maps to
remoteFault(5), and Auto-Negotiation Error maps to
autoNegError(11).
The value remoteFault(5) applies to 10BASE-FB remote
fault indication, the 100BASE-X far-end fault indication, and
nonspecified remote faults from a system running Clause 28
Auto-Negotiation.
The value remoteJabber(7), remoteLink loss(8), or remoteTest(9)
SHOULD be used instead of remoteFault(5) where the reason for
remote fault is identified in the remote signaling protocol.
Where a Clause 22 MII or Clause 35 GMII is present, a logic
one in the remote fault bit maps to the value remoteFault(5),
a logic zero in the link status bit maps to the enumeration
notAvailable(4). The value notAvailable(4) takes precedence
over remoteFault(5).
For 2BASE-TL and 10PASS-TS PHYs, the value unknown(2) maps to
the condition where the PHY (PCS with connected PMEs) is
initializing, the value ready(20) maps to the condition where
the interface is down and at least one PME in the aggregation
group is ready for handshake, the value available(3) maps to
the condition where all the PMEs in the aggregation group are
up, the value notAvailable(4) maps to the condition where all
the PMEs in the aggregation group are down and no handshake
tones are detected, the value availableReduced(19) maps to the
condition where the interface is up, a link fault is detected
at the receive direction by one or more PMEs in the
aggregation group, but at least one PME is up and the
enumeration pmdLinkFault(12) maps to the condition where a link
fault is detected at the receive direction by all of the PMEs
in the aggregation group.
For 10 Gb/s the enumerations map to value of the link_fault
variable within the Link Fault Signaling state diagram
as follows: the value OK maps to the value available(3),
the value Local Fault maps to the value notAvailable(4),
and the value Remote Fault maps to the value remoteFault(5).
The value pmdLinkFault(12), wisFrameLoss(13),
wisSignalLoss(14), pcsLinkFault(15), excessiveBER(16), or
dxsLinkFault(17) SHOULD be used instead of the value
notAvailable(4), where the reason for the Local Fault state can
be identified through the use of the Clause 45 MDIO Interface.
Where multiple reasons for the Local Fault state can be
identified, only the highest precedence error SHOULD be
reported. This precedence in descending order is as follows:
pxsLinkFault
pmdLinkFault
wisFrameLoss
wisSignalLoss
pcsLinkFault
excessiveBER
dxsLinkFault.
Where a Clause 45 MDIO interface is present a logic zero in
the PMA/PMD Receive link status bit ([IEEE802.3]
Section 45.2.1.2.2) maps to the value pmdLinkFault(12),
logic one in the LOF status bit (Section 45.2.2.10.4) maps
to the value wisFrameLoss(13), a logic one in the LOS
status bit (Section 45.2.2.10.5) maps to the value
wisSignalLoss, a logic zero in the PCS Receive
link status bit (Section 45.2.3.2.2) maps to the value
pcsLinkFault(15), a logic one in the 10GBASE-R PCS Latched
high BER status bit (Section 45.2.3.12.2) maps to the value
excessiveBER, a logic zero in the DTE XS receive link status
bit (Section 45.2.5.2.2) maps to the value dxsLinkFault(17)
and a logic zero in the PHY XS transmit link status bit
(Section 45.2.4.2.2) maps to the value pxsLinkFault(18).
The most recent version of this textual convention is available
in the online version of this MIB module on the IANA web site.
Requests for new values should be made to IANA via email
(iana@iana.org)."
REFERENCE
"[IEEE802.3], Section 30.5.1.1.4"
SYNTAX INTEGER {
other(1),
unknown(2),
available(3),
notAvailable(4),
remoteFault(5),
invalidSignal(6),
remoteJabber(7),
remoteLinkLoss(8),
remoteTest(9),
offline(10),
autoNegError(11),
pmdLinkFault(12),
wisFrameLoss(13),
wisSignalLoss(14),
pcsLinkFault(15),
excessiveBER(16),
dxsLinkFault(17),
pxsLinkFault(18),
availableReduced(19),
ready(20)
}
Next up is the auto-negotiation capability bits, which are basically a checklist of everything a MAU can flex 🌸 Bits, bits, bits 💜
IANAifMauAutoNegCapBits ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This data type is used as the syntax of the
ifMauAutoNegCapabilityBits, ifMauAutoNegCapAdvertisedBits, and
ifMauAutoNegCapReceivedBits objects in the (updated) definition
of MAU-MIB's ifMauAutoNegTable.
The most recent version of this textual convention is available
in the online version of this MIB module on the IANA web site.
Requests for new values should be made to IANA via email
(iana@iana.org)."
REFERENCE
"[IEEE802.3], Section 30.6.1.1.5"
SYNTAX BITS {
bOther(0), -- other or unknown
b10baseT(1), -- 10BASE-T half duplex mode
b10baseTFD(2), -- 10BASE-T full duplex mode
b100baseT4(3), -- 100BASE-T4
b100baseTX(4), -- 100BASE-TX half duplex mode
b100baseTXFD(5), -- 100BASE-TX full duplex mode
b100baseT2(6), -- 100BASE-T2 half duplex mode
b100baseT2FD(7), -- 100BASE-T2 full duplex mode
bFdxPause(8), -- PAUSE for full-duplex links
bFdxAPause(9), -- Asymmetric PAUSE for full-duplex
-- links
bFdxSPause(10), -- Symmetric PAUSE for full-duplex
-- links
bFdxBPause(11), -- Asymmetric and Symmetric PAUSE for
-- full-duplex links
b1000baseX(12), -- 1000BASE-X, -LX, -SX, -CX half
-- duplex mode
b1000baseXFD(13), -- 1000BASE-X, -LX, -SX, -CX full
-- duplex mode
b1000baseT(14), -- 1000BASE-T half duplex mode
b1000baseTFD(15) -- 1000BASE-T full duplex mode
}
Now the jack types, aka the plugs and ports that make the physical connection happen 🔌✨ Super practical, very iconic 🍓
IANAifJackType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Common enumeration values for repeater and interface MAU
jack types. This data type is used as the syntax of the
ifJackType and rpJackType objects in the (updated) definition
of MAU-MIB's ifJackTable and rpJackTable respectively.
Possible values are:
other(1) - undefined or unknown
rj45(2) - RJ45
rj45S(3) - RJ45 shielded
db9(4) - DB9
bnc(5) - BNC
fAUI(6) - AUI female
mAUI(7) - AUI male
fiberSC(8) - SC fiber
fiberMIC(9) - MIC fiber
fiberST(10) - ST fiber
telco(11) - Telco
mtrj(12) - MT-RJ fiber
hssdc(13) - fiber channel style-2
fiberLC(14) - LC fiber
cx4(15) - IB4X for 10GBASE-CX4
The most recent version of this textual convention is available
in the online version of this MIB module on the IANA web site.
Requests for new values should be made to IANA via email
(iana@iana.org)."
SYNTAX INTEGER {
other(1),
rj45(2),
rj45S(3),
db9(4),
bnc(5),
fAUI(6),
mAUI(7),
fiberSC(8),
fiberMIC(9),
fiberST(10),
telco(11),
mtrj(12),
hssdc(13),
fiberLC(14),
-- new since RFC 3636
cx4(15)
}
Last bit for this stretch: the MAU type object identifiers. These are the named little tags for each kind of MAU, and they're giving very organised energy 🧚💖
-- OBJECT IDENTITIES for MAU types
-- (see rpMauType and ifMauType of MAU-MIB for usage)
-- The following definitions has been moved from RFC 3636 and
-- no longer appear in its revision.
dot3MauType OBJECT IDENTIFIER ::= { mib-2 snmpDot3MauMgt(26) 4 }
dot3MauTypeAUI OBJECT-IDENTITY
STATUS current
DESCRIPTION "no internal MAU, view from AUI"
REFERENCE "[IEEE802.3], Section 7"
::= { dot3MauType 1 }
dot3MauType10Base5 OBJECT-IDENTITY
STATUS current
DESCRIPTION "thick coax MAU"
REFERENCE "[IEEE802.3], Section 7"
::= { dot3MauType 2 }
dot3MauTypeFoirl OBJECT-IDENTITY
STATUS current
DESCRIPTION "FOIRL MAU"
REFERENCE "[IEEE802.3], Section 9.9"
::= { dot3MauType 3 }
dot3MauType10Base2 OBJECT-IDENTITY
STATUS current
DESCRIPTION "thin coax MAU"
REFERENCE "[IEEE802.3], Section 10"
::= { dot3MauType 4 }
dot3MauType10BaseT OBJECT-IDENTITY
STATUS current
DESCRIPTION "UTP MAU.
Note that it is strongly recommended that
agents return either dot3MauType10BaseTHD or
dot3MauType10BaseTFD if the duplex mode is
known. However, management applications should
be prepared to receive this MAU type value from
older agent implementations."
REFERENCE "[IEEE802.3], Section 14"
::= { dot3MauType 5 }
dot3MauType10BaseFP OBJECT-IDENTITY
STATUS current
DESCRIPTION "passive fiber MAU"
REFERENCE "[IEEE802.3], Section 16"
::= { dot3MauType 6 }
dot3MauType10BaseFB OBJECT-IDENTITY
STATUS current
DESCRIPTION "sync fiber MAU"
REFERENCE "[IEEE802.3], Section 17"
::= { dot3MauType 7 }
dot3MauType10BaseFL OBJECT-IDENTITY STATUS current DESCRIPTION "async fiber MAU. Note that it is strongly recommended that agents return either dot3MauType10BaseFLHD or dot3MauType10BaseFLFD if the duplex mode is known. However, management applications should be prepared to receive this MAU type value from older agent implementations." REFERENCE "[IEEE802.3], Section 18" ::= { dot3MauType 8 }
dot3MauType10Broad36 OBJECT-IDENTITY STATUS current DESCRIPTION "broadband DTE MAU. Note that 10BROAD36 MAUs can be attached to interfaces but not to repeaters." REFERENCE "[IEEE802.3], Section 11" ::= { dot3MauType 9 }
------ new since RFC 1515: dot3MauType10BaseTHD OBJECT-IDENTITY STATUS current DESCRIPTION "UTP MAU, half duplex mode" REFERENCE "[IEEE802.3], Section 14" ::= { dot3MauType 10 }
dot3MauType10BaseTFD OBJECT-IDENTITY STATUS current DESCRIPTION "UTP MAU, full duplex mode" REFERENCE "[IEEE802.3], Section 14" ::= { dot3MauType 11 }
dot3MauType10BaseFLHD OBJECT-IDENTITY STATUS current DESCRIPTION "async fiber MAU, half duplex mode" REFERENCE "[IEEE802.3], Section 18" ::= { dot3MauType 12 }
dot3MauType10BaseFLFD OBJECT-IDENTITY STATUS current DESCRIPTION "async fiber MAU, full duplex mode" REFERENCE "[IEEE802.3], Section 18" ::= { dot3MauType 13 }
dot3MauType100BaseT4 OBJECT-IDENTITY STATUS current DESCRIPTION "4 pair category 3 UTP" REFERENCE "[IEEE802.3], Section 23" ::= { dot3MauType 14 }
dot3MauType100BaseTXHD OBJECT-IDENTITY STATUS current DESCRIPTION "2 pair category 5 UTP, half duplex mode" REFERENCE "[IEEE802.3], Section 25" ::= { dot3MauType 15 }
dot3MauType100BaseTXFD OBJECT-IDENTITY STATUS current DESCRIPTION "2 pair category 5 UTP, full duplex mode" REFERENCE "[IEEE802.3], Section 25" ::= { dot3MauType 16 }
dot3MauType100BaseFXHD OBJECT-IDENTITY STATUS current DESCRIPTION "X fiber over PMT, half duplex mode" REFERENCE "[IEEE802.3], Section 26" ::= { dot3MauType 17 }
dot3MauType100BaseFXFD OBJECT-IDENTITY STATUS current DESCRIPTION "X fiber over PMT, full duplex mode" REFERENCE "[IEEE802.3], Section 26" ::= { dot3MauType 18 }
dot3MauType100BaseT2HD OBJECT-IDENTITY STATUS current DESCRIPTION "2 pair category 3 UTP, half duplex mode" REFERENCE "[IEEE802.3], Section 32" ::= { dot3MauType 19 }
dot3MauType100BaseT2FD OBJECT-IDENTITY STATUS current DESCRIPTION "2 pair category 3 UTP, full duplex mode" REFERENCE "[IEEE802.3], Section 32" ::= { dot3MauType 20 }
------ new since RFC 2239: dot3MauType1000BaseXHD OBJECT-IDENTITY STATUS current DESCRIPTION "PCS/PMA, unknown PMD, half duplex mode" REFERENCE "[IEEE802.3], Section 36" ::= { dot3MauType 21 }
dot3MauType1000BaseXFD OBJECT-IDENTITY STATUS current DESCRIPTION "PCS/PMA, unknown PMD, full duplex mode" REFERENCE "[IEEE802.3], Section 36" ::= { dot3MauType 22 }
dot3MauType1000BaseLXHD OBJECT-IDENTITY STATUS current DESCRIPTION "Fiber over long-wavelength laser, half duplex mode" REFERENCE "[IEEE802.3], Section 38" ::= { dot3MauType 23 }
dot3MauType1000BaseLXFD OBJECT-IDENTITY STATUS current DESCRIPTION "Fiber over long-wavelength laser, full duplex mode" REFERENCE "[IEEE802.3], Section 38" ::= { dot3MauType 24 }
dot3MauType1000BaseSXHD OBJECT-IDENTITY STATUS current DESCRIPTION "Fiber over short-wavelength laser, half duplex mode" REFERENCE "[IEEE802.3], Section 38" ::= { dot3MauType 25 }
dot3MauType1000BaseSXFD OBJECT-IDENTITY STATUS current DESCRIPTION "Fiber over short-wavelength laser, full duplex mode" REFERENCE "[IEEE802.3], Section 38" ::= { dot3MauType 26 }
dot3MauType1000BaseCXHD OBJECT-IDENTITY STATUS current DESCRIPTION "Copper over 150-Ohm balanced cable, half duplex mode" REFERENCE "[IEEE802.3], Section 39" ::= { dot3MauType 27 }
dot3MauType1000BaseCXFD OBJECT-IDENTITY STATUS current DESCRIPTION "Copper over 150-Ohm balanced cable, full
duplex mode" REFERENCE "[IEEE802.3], Section 39" ::= { dot3MauType 28 }
dot3MauType1000BaseTHD OBJECT-IDENTITY STATUS current DESCRIPTION "Four-pair Category 5 UTP, half duplex mode" REFERENCE "[IEEE802.3], Section 40" ::= { dot3MauType 29 }
dot3MauType1000BaseTFD OBJECT-IDENTITY STATUS current DESCRIPTION "Four-pair Category 5 UTP, full duplex mode" REFERENCE "[IEEE802.3], Section 40" ::= { dot3MauType 30 }
------ new since RFC 2668: dot3MauType10GigBaseX OBJECT-IDENTITY STATUS current DESCRIPTION "X PCS/PMA, unknown PMD." REFERENCE "[IEEE802.3], Section 48" ::= { dot3MauType 31 }
dot3MauType10GigBaseLX4 OBJECT-IDENTITY STATUS current DESCRIPTION "X fiber over WWDM optics" REFERENCE "[IEEE802.3], Section 53" ::= { dot3MauType 32 }
dot3MauType10GigBaseR OBJECT-IDENTITY STATUS current DESCRIPTION "R PCS/PMA, unknown PMD." REFERENCE "[IEEE802.3], Section 49" ::= { dot3MauType 33 }
dot3MauType10GigBaseER OBJECT-IDENTITY STATUS current DESCRIPTION "R fiber over 1550 nm optics" REFERENCE "[IEEE802.3], Section 52" ::= { dot3MauType 34 }
dot3MauType10GigBaseLR OBJECT-IDENTITY STATUS current DESCRIPTION "R fiber over 1310 nm optics" REFERENCE "[IEEE802.3], Section 52" ::= { dot3MauType 35 }
dot3MauType10GigBaseSR OBJECT-IDENTITY
STATUS current DESCRIPTION "R fiber over 850 nm optics" REFERENCE "[IEEE802.3], Section 52" ::= { dot3MauType 36 }
dot3MauType10GigBaseW OBJECT-IDENTITY STATUS current DESCRIPTION "W PCS/PMA, unknown PMD." REFERENCE "[IEEE802.3], Section 49 and 50" ::= { dot3MauType 37 }
dot3MauType10GigBaseEW OBJECT-IDENTITY STATUS current DESCRIPTION "W fiber over 1550 nm optics" REFERENCE "[IEEE802.3], Section 52" ::= { dot3MauType 38 }
dot3MauType10GigBaseLW OBJECT-IDENTITY STATUS current DESCRIPTION "W fiber over 1310 nm optics" REFERENCE "[IEEE802.3], Section 52" ::= { dot3MauType 39 }
dot3MauType10GigBaseSW OBJECT-IDENTITY STATUS current DESCRIPTION "W fiber over 850 nm optics" REFERENCE "[IEEE802.3], Section 52" ::= { dot3MauType 40 }
------ new since RFC 3636: dot3MauType10GigBaseCX4 OBJECT-IDENTITY STATUS current DESCRIPTION "X copper over 8 pair 100-Ohm balanced cable" REFERENCE "[IEEE802.3], Section 54" ::= { dot3MauType 41 }
dot3MauType2BaseTL OBJECT-IDENTITY STATUS current DESCRIPTION "Voice grade UTP copper, up to 2700m, optional PAF" REFERENCE "[IEEE802.3], Sections 61 and 63" ::= { dot3MauType 42 }
dot3MauType10PassTS OBJECT-IDENTITY STATUS current DESCRIPTION "Voice grade UTP copper, up to 750m, optional PAF" REFERENCE "[IEEE802.3], Sections 61 and 62" ::= { dot3MauType 43 }
dot3MauType100BaseBX10D OBJECT-IDENTITY STATUS current DESCRIPTION "One single-mode fiber OLT, long wavelength, 10km" REFERENCE "[IEEE802.3], Section 58" ::= { dot3MauType 44 }
dot3MauType100BaseBX10U OBJECT-IDENTITY STATUS current DESCRIPTION "One single-mode fiber ONU, long wavelength, 10km" REFERENCE "[IEEE802.3], Section 58" ::= { dot3MauType 45 }
dot3MauType100BaseLX10 OBJECT-IDENTITY STATUS current DESCRIPTION "Two single-mode fibers, long wavelength, 10km" REFERENCE "[IEEE802.3], Section 58" ::= { dot3MauType 46 }
dot3MauType1000BaseBX10D OBJECT-IDENTITY STATUS current DESCRIPTION "One single-mode fiber OLT, long wavelength, 10km" REFERENCE "[IEEE802.3], Section 59" ::= { dot3MauType 47 }
dot3MauType1000BaseBX10U OBJECT-IDENTITY STATUS current DESCRIPTION "One single-mode fiber ONU, long wavelength, 10km" REFERENCE "[IEEE802.3], Section 59" ::= { dot3MauType 48 }
dot3MauType1000BaseLX10 OBJECT-IDENTITY STATUS current DESCRIPTION "Two sigle-mode fiber, long wavelength, 10km" REFERENCE "[IEEE802.3], Section 59" ::= { dot3MauType 49 }
dot3MauType1000BasePX10D OBJECT-IDENTITY STATUS current DESCRIPTION "One single-mode fiber EPON OLT, 10km" REFERENCE "[IEEE802.3], Section 60" ::= { dot3MauType 50 }
dot3MauType1000BasePX10U OBJECT-IDENTITY STATUS current DESCRIPTION "One single-mode fiber EPON ONU, 10km" REFERENCE "[IEEE802.3], Section 60" ::= { dot3MauType 51 }
dot3MauType1000BasePX20D OBJECT-IDENTITY STATUS current DESCRIPTION "One single-mode fiber EPON OLT, 20km" REFERENCE "[IEEE802.3], Section 60" ::= { dot3MauType 52 }
dot3MauType1000BasePX20U OBJECT-IDENTITY STATUS current DESCRIPTION "One single-mode fiber EPON ONU, 20km" REFERENCE "[IEEE802.3], Section 60" ::= { dot3MauType 53 }
END
6. Security Considerations 🔒✨
Okay bestie, this is the serious bit 🫶 The IANA-MAU-MIB doesn't define any management objects of its own. What it does is define a set of textual conventions that the MAU-MIB uses, and other MIB modules can use them too to define their own objects. So real security considerations can only be written for MIB modules that actually define management objects 💅
The MAU-MIB has a bunch of objects with a MAX-ACCESS of read-write, and changing those can seriously mess with how the network runs 😭 Things like:
- enabling or disabling a MAU
- changing a MAU's default type
- enabling, disabling, or restarting autonegotiation
- modifying the capabilities that a MAU advertizes during autonegotiation
These objects can be sensitive or vulnerable in some network environments 💀 Supporting SET operations in a non-secure environment, without proper protection, can have a negative effect on network operations. Not a vibe 🙅♀️
Some of the readable objects in the MAU-MIB (the ones whose MAX-ACCESS isn't not-accessible) can also be sensitive in some environments 🌸 Sometimes you really don't want unauthorized people peeking at statistics or status info about individual links. So it's important to control even GET and/or NOTIFY access to these objects, and maybe even encrypt their values when they're sent over the network via SNMP 🔐
Here's the tea ☕ SNMP versions before SNMPv3 didn't include adequate security. And even if the network itself is secure (say, by using IPsec), there's still no control over who on that secure network gets to GET and SET (read, change, create, or delete) the objects in the MAU-MIB module 🙈
It is RECOMMENDED that the implementors consider the security features provided by the SNMPv3 framework (see [RFC3410], section 8), including full support for the SNMPv3 cryptographic mechanisms (for authentication and privacy) 🦋
Furthermore, deploying SNMP versions prior to SNMPv3 is NOT RECOMMENDED 🚫 Instead, it is RECOMMENDED to deploy SNMPv3 and turn on cryptographic security. And then it's a customer/operator responsibility to make sure the SNMP entity giving access to an instance of the MAU-MIB module is configured properly, so the objects are only accessible to the principals (users) who have legitimate rights to GET or SET (change, create, or delete) them 👑
7. IANA Considerations 🌈
This document defines the first version of the IANA-maintained IANA-MAU-MIB module 🎀 The plan is to add each new MAU type, Media Available state, Auto Negotiation capability, and/or Jack type that the IEEE 802.3 working group defines and approves for publication in a revision of IEEE Std 802.3, to the IANA-maintaned MIB module. That's provided it's suitable for being managed by the base objects in the MAU-MIB module ✨
For each new MAU type added, a short description of the MAU technology should be specified, and wherever possible, a reference to a publicly available specification SHOULD be specified too 📚 An Expert Review, as defined in RFC 2434 [RFC2434], is REQUIRED for each modification 🧚
8. Acknowledgments 💜
This document was produced by the IETF Ethernet Interfaces and Hub MIB Working Group, whose efforts were hugely advanced by the contributions of these lovely people 🫶
- Mike Heard
- John Flick
- Dan Romascanu
This document is based on the Proposed Standard MAU MIB, RFC 3636 [RFC3636], edited by John Flick of Hewlett-Packard and produced by the Ethernet Interfaces and Hub MIB Working Group. It extends that document by moving the object identities and textual conventions for MAU types into an IANA-maintained MIB module. On top of that, support is provided for the EFM and 10GBASE-CX4 MAUs as defined in [IEEE802.3ah] and [IEEE802.3ak] respectively 🍓
RFC 3636, in turn, was based on the Proposed Standard MAU MIB, RFC 2668 [RFC2668], edited by John Flick of Hewlett-Packard and Andrew Smith, then of Extreme Networks, and produced by the Ethernet Interfaces and Hub MIB Working Group. It extends that document by providing support for 10 Gb/s MAUs as defined in [IEEE802.3ae] 🔥
RFC 2668, in turn, was based on the Proposed Standard MAU MIB, RFC 2239 [RFC2239], edited by Kathryn de Graaf, then of 3Com, and Dan Romascanu, then of Madge Networks, and produced by the Ethernet Interfaces and Hub MIB Working Group. It extended that document by providing support for 1000 Mb/sec MAUs, PAUSE negotiation and remote fault status as defined in [IEEE802.3] 🌸
RFC 2239, in turn, was based on the Proposed Standard MAU MIB, RFC 1515 [RFC1515], edited by Donna McMaster, then of SynOptics Communications, Keith McCloghrie, then of Hughes LAN Systems, and Sam Roberts, then of Farallon Computing, and produced by the Hub MIB Working Group. It extended that document by providing support for 100 Mb/sec MAUs, full duplex MAUs, auto-negotiation, and jack management as defined in [IEEE802.3] 🧚♀️
9. References 📖
9.1. Normative References
These are the must-read ones 🤓 Here they are, exactly as written:
[IEEE802.3] IEEE, "IEEE Standard for Information technology -
Telecommunications and information exchange between
systems - Local and metropolitan area networks -
Specific requirements - Part 3: Carrier sense multiple
access with collision detection (CSMA/CD) access
method and physical layer specifications", IEEE
Std 802.3-2005, December 2005.
[IEEE802.3ae] IEEE, "IEEE Standard for Information technology -
Telecommunications and information exchange between
systems - Local and metropolitan area networks -
Specific requirements - Part 3: Carrier sense multiple
access with collision detection (CSMA/CD) access
method and physical layer specifications - Media
Access Control (MAC) Parameters, Physical Layer and
Management Parameters for 10 Gb/s Operation", IEEE
Std 802.3ae-2002, August 2002.
[IEEE802.3ah] IEEE, "Information technology - Telecommunications and
information exchange between systems - Local and
metropolitan area networks - Specific requirements -
Part 3: Carrier sense multiple access with collision
detection (CSMA/CD) access method and physical layer
specifications - Media Access Control Parameters,
Physical Layers and Management Parameters for
Subscriber Access Networks", IEEE Std 802.3ah-2004,
September 2004.
[IEEE802.3ak] IEEE, "IEEE Standard for Information technology -
Telecommunications and information exchange between
systems - Local and metropolitan area networks -
Specific requirements - Part 3: Carrier sense multiple
access with collision detection (CSMA/CD) access
method and physical layer specifications - Physical
Layer and Management Parameters for 10Gb/s Operation,
Type 10GBASE-CX4", IEEE Std 802.3ak-2004, March 2004.
[RFC2108] de Graaf, K., Romascanu, D., McMaster, D., and K.
McCloghrie, "Definitions of Managed Objects for IEEE
802.3 Repeater Devices using SMIv2", RFC 2108,
February 1997.
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119, March 1997.
[RFC2434] Narten, T. and H. Alvestrand, "Guidelines for Writing
an IANA Considerations Section in RFCs", BCP 26,
RFC 2434, October 1998.
[RFC2578] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Structure of Management
Information Version 2 (SMIv2)", STD 58, RFC 2578,
April 1999.
[RFC2579] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Textual Conventions for SMIv2",
STD 58, RFC 2579, April 1999.
[RFC2580] McCloghrie, K., Perkins, D., and J. Schoenwaelder,
"Conformance Statements for SMIv2", STD 58, RFC 2580,
April 1999.
[RFC2863] McCloghrie, K. and F. Kastenholz, "The Interfaces
Group MIB", RFC 2863, June 2000.
[RFC3635] Flick, J., "Definitions of Managed Objects for the
Ethernet-like Interface Types", RFC 3635,
September 2003.
9.2. Informative References
These ones are more for background vibes 🌙
[RFC1515] McMaster, D., McCloghrie, K., and S. Roberts,
"Definitions of Managed Objects for IEEE 802.3 Medium
Attachment Units (MAUs)", RFC 1515, September 1993.
[RFC2239] de Graaf, K., Romascanu, D., McMaster, D., McCloghrie,
K., and S. Roberts, "Definitions of Managed Objects
for IEEE 802.3 Medium Attachment Units (MAUs) using
SMIv2", RFC 2239, November 1997.
[RFC2668] Smith, A., Flick, J., de Graaf, K., Romascanu, D.,
McMaster, D., McCloghrie, K., and S. Roberts,
"Definitions of Managed Objects for IEEE 802.3 Medium
Attachment Units (MAUs)", RFC 2668, August 1999.
[RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart,
"Introduction and Applicability Statements for
Internet-Standard Management Framework", RFC 3410,
December 2002.
[RFC3418] Presuhn, R., "Management Information Base (MIB) for
the Simple Network Management Protocol (SNMP)",
STD 62, RFC 3418, December 2002.
[RFC3636] Flick, J., "Definitions of Managed Objects for IEEE
802.3 Medium Attachment Units (MAUs)", RFC 3636,
September 2003.
[RFC3637] Heard, C., "Definitions of Managed Objects for the
Ethernet WAN Interface Sublayer", RFC 3637,
September 2003.
Author's Address 🖊️
Edward Beili
Actelis Networks
Bazel 25
Petach-Tikva
Israel
Phone: +972-3-924-3491
EMail: edward.beili@actelis.com
Full Copyright Statement ©️
Copyright (C) The IETF Trust (2007).
This document is subject to the rights, licenses and restrictions contained in BCP 78, and except as set forth therein, the authors retain all their rights.
This document and the information contained herein are provided on an "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY, THE IETF TRUST AND THE INTERNET ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 💖
Intellectual Property ✨
okay bestie, so the IETF is NOT taking a side on whether any patents or other IP rights that someone might claim over the tech in this doc are valid, or how far they reach 💅. It also doesn't say whether any license for them exists or doesn't 🙈, and it's not claiming it went digging for those rights itself. If you want the rules on IP stuff for RFC documents, check out BCP 78 and BCP 79 🎀.
Next up: copies of IPR disclosures sent to the IETF Secretariat, any assurances that licenses will be available, and the results of any attempt to get a general license or permission for implementers or users to use those proprietary rights can all be found in the IETF online IPR repository at http://www.ietf.org/ipr 🦋.
The IETF also invites anyone to flag any copyrights, patents, patent applications, or other proprietary rights that might cover tech needed to implement this standard 🫶. Send that info to the IETF at ietf-ipr@ietf.org 💌.
Acknowledgement
Funding for the RFC Editor function is currently provided by the Internet Society 🌸💜
📦 where this page comes from
- ietf: rfc4836 2007-04
- 💖 girlified by claude-haiku-5-5 on : a language model's rewrite of the original, under its terms