RFC 2819
Remote Network Monitoring Management Information Base
Title Block ๐โจ
okay bestie, read this first ๐ This is RFC 2819 (Network Working Group, STD: 59) by S. Waldbusser of Lucent Technologies, dated May 2000. It's on the Standards Track, and it obsoletes RFC 1757 ๐ฆ. The title is "Remote Network Monitoring Management Information Base," aka the RMON MIB ๐ฅ
Status of this Memo ๐ธ
okay so this doc is an Internet standards track protocol for the Internet community, and it's asking for discussion and suggestions for improvements ๐ for the current standardization state and status, check the "Internet Official Protocol Standards" (STD 1). distribution of this memo is unlimited, so share it with everyone ๐ซถ
Copyright Notice ๐
Copyright (C) The Internet Society (2000). All Rights Reserved. โจ
Abstract ๐
this memo defines a chunk of the Management Information Base (MIB) for network management protocols in TCP/IP-based internets. the main point is objects for managing remote network monitoring devices ๐ง
this memo obsoletes RFC 1757. it extends that spec by writing the RMON MIB in SMIv2 format, and it stays semantically identical to the existing SMIv1-based MIB ๐
Table of Contents ๐
1 The SNMP Management Framework .............................. 2
2 Overview ................................................... 3
2.1 Remote Network Management Goals .......................... 4
2.2 Textual Conventions ...................................... 5
2.3 Structure of MIB ......................................... 5
2.3.1 The Ethernet Statistics Group .......................... 6
2.3.2 The History Control Group .............................. 6
2.3.3 The Ethernet History Group ............................. 6
2.3.4 The Alarm Group ........................................ 7
2.3.5 The Host Group ......................................... 7
2.3.6 The HostTopN Group ..................................... 7
2.3.7 The Matrix Group ....................................... 7
2.3.8 The Filter Group ....................................... 7
2.3.9 The Packet Capture Group ............................... 8
2.3.10 The Event Group ....................................... 8
3 Control of Remote Network Monitoring Devices ............... 8
3.1 Resource Sharing Among Multiple Management Stations ... 9
3.2 Row Addition Among Multiple Management Stations .......... 10
4 Conventions ................................................ 11
5 Definitions ................................................ 12
6 Security Considerations .................................... 94
7 Acknowledgments ............................................ 95
8 Author's Address ........................................... 95
9 References ................................................. 95
10 Intellectual Property ..................................... 97
11 Full Copyright Statement .................................. 98
1. The SNMP Management Framework ๐ฆ
okay so the SNMP Management Framework currently has five major components ๐
- Architecture ๐ธ: an overall architecture, described in RFC 2571 [1].
- Describing and naming ๐ : mechanisms for describing and naming objects and events for management purposes. the first version of this Structure of Management Information (SMI) is SMIv1, described in STD 16, RFC 1155 [2], STD 16, RFC 1212 [3] and RFC 1215 [4]. the second version, SMIv2, is described in STD 58, RFC 2578 [5], RFC 2579 [6] and RFC 2580 [7].
- Message protocols ๐: for transferring management information. the first version of the SNMP message protocol is SNMPv1, described in STD 15, RFC 1157 [8]. a second version, SNMPv2c, which is not an Internet standards track protocol, is described in RFC 1901 [9] and RFC 1906 [10]. the third version of the message protocol is SNMPv3, described in RFC 1906 [10], RFC 2572 [11] and RFC 2574 [12].
- Protocol operations ๐ง: for accessing management information. the first set of protocol operations and associated PDU formats is described in STD 15, RFC 1157 [8]. a second set of protocol operations and associated PDU formats is described in RFC 1905 [13].
- Fundamental applications ๐: a set of fundamental applications is described in RFC 2573 [14], and the view-based access control mechanism is described in RFC 2575 [15].
if you want the deeper intro to the current SNMP Management Framework, check RFC 2570 [22] ๐ซถ
managed objects are accessed through a virtual information store called the Management Information Base, or MIB. objects in the MIB are defined using the mechanisms defined in the SMI ๐
this memo specifies a MIB module that is compliant to SMIv2. a MIB conforming to SMIv1 can be produced through the appropriate translations. the translated MIB must be semantically equivalent, except where objects or events are omitted because no translation is possible (use of Counter64). some machine readable information in SMIv2 gets converted into textual descriptions in SMIv1 during translation. however, that loss of machine readable information is not considered to change the semantics of the MIB โจ
2. Overview ๐ธ
okay so remote network monitoring devices, often called monitors or probes, are instruments that exist to manage a network ๐ฅ they're often stand-alone devices and they devote significant internal resources to nothing but managing a network. an organization may employ many of these, one per network segment, to manage its internet. these devices may also be used by a network management service provider to access a client network, which is often geographically remote ๐ฆ
the objects in this document are meant to be an interface between an RMON agent and an RMON management application. they are not meant for direct manipulation by humans ๐ some users may tolerate direct display of some of these objects, but few will tolerate the complexity of manually manipulating objects to accomplish row creation. those jobs should be handled by the management application ๐
most objects here work for managing any type of network, but some are specific to Ethernet. those are the objects in the etherStatsTable, the etherHistoryTable, and some attributes of the filterPktStatus and capturBufferPacketStatus objects. the design of this MIB lets similar objects be defined for other network types, and future versions of this document and additional documents are intended to define extensions for other network types ๐
there are a bunch of companion documents to the RMON MIB ๐ the Token Ring RMON MIB [19] has objects for managing Token Ring networks. the RMON-2 MIB [20] extends RMON by providing RMON analysis up to the application layer. the SMON MIB [21] extends RMON by providing RMON analysis for switched networks โจ
2.1. Remote Network Management Goals ๐
- Offline Operation ๐
sometimes a management station won't be in constant contact with its remote monitoring devices. that can be by design, to lower communication costs (especially over a WAN or dialup link), or by accident, when network failures get in the way of communication between the management station and the probe ๐ญ
so this MIB lets a probe be configured to run diagnostics and collect statistics continuously, even when talking to the management station may not be possible or efficient. the probe may then try to notify the management station when something exceptional happens. that way, even when the connection between station and probe isn't continuous, fault, performance, and configuration information can keep building up and get sent to the management station conveniently and efficiently ๐ซถ
- Proactive Monitoring ๐ง
the monitor has resources to spare, so it's potentially helpful for it to keep running diagnostics and logging network performance all the time. the monitor is always available at the onset of any failure. it can notify the management station about the failure and store historical statistical info about it. the management station can play that history back to dig further into the cause of the problem ๐ฅ
- Problem Detection and Reporting ๐
the monitor can be set up to recognize conditions, especially error conditions, and keep checking for them. when one of those conditions happens, the event may be logged, and management stations may be notified in a number of ways ๐
- Value Added Data ๐
a remote monitoring device is a network resource dedicated entirely to network management, and it sits right on the monitored part of the network. so it has the chance to add real value to the data it collects. for example, by highlighting the hosts that generate the most traffic or errors, the probe can hand the management station exactly the info it needs to solve a class of problems ๐ฆ
- Multiple Managers ๐ธ
an organization may have multiple management stations for different units, for different functions (e.g. engineering and operations), and to provide disaster recovery. since environments with multiple management stations are common, the remote network monitoring device has to deal with more than its own management station, potentially using its resources at the same time ๐
2.2. Textual Conventions ๐
two new data types are introduced as textual conventions in this MIB document: OwnerString and EntryStatus โจ
2.3. Structure of MIB ๐
okay so the objects are arranged into these groups ๐ง
ethernet statisticshistory controlethernet historyalarmhosthostTopNmatrixfilterpacket captureevent
these groups are the basic unit of conformance ๐ฅ if a remote monitoring device implements a group, then it must implement all objects in that group. for example, an agent that implements the host group must implement the hostControlTable, the hostTable and the hostTimeTable ๐ซถ this section is just the overview of grouping and conformance info. the authoritative reference for that is in the MODULE-COMPLIANCE and OBJECT-GROUP macros later in this MIB ๐
all groups in this MIB are optional ๐ธ implementations of this MIB must also implement the system group of MIB-II [16] and the IF-MIB [17]. MIB-II may also mandate implementation of additional groups ๐
these groups exist to provide a way of assigning object identifiers, and a method for implementors of managed agents to know which objects they must implement ๐
2.3.1. The Ethernet Statistics Group ๐ฆ
okay so the ethernet statistics group is where the probe keeps its stats for each ethernet interface it monitors on this device ๐ bestie, it's giving one big table: the etherStatsTable ๐
2.3.2. The History Control Group ๐ฐ๏ธ
the history control group is the boss of periodic sampling โจ it controls how data gets sampled from different types of networks over time. this group is just the historyControlTable ๐ธ
2.3.3. The Ethernet History Group ๐
the ethernet history group records periodic statistical samples from an ethernet network and stores them so you can pull them back up later ๐ซถ it consists of the etherHistoryTable ๐
2.3.4. The Alarm Group ๐จ
the alarm group periodically takes statistical samples from variables in the probe and compares them to thresholds that were configured earlier ๐ if a monitored variable crosses a threshold, an event gets generated ๐ฅ
A hysteresis mechanism is implemented to limit the generation of alarms ๐ก๏ธ this group consists of the alarmTable and requires the implementation of the event group ๐ง
2.3.5. The Host Group ๐
the host group holds statistics for each host discovered on the network ๐ฅ๏ธ it finds hosts by keeping a list of source and destination MAC Addresses seen in good packets promiscuously received from the network ๐ this group consists of the hostControlTable, the hostTable, and the hostTimeTable ๐
2.3.6. The HostTopN Group ๐
the hostTopN group prepares reports about the hosts that top a list ordered by one of their statistics ๐ the available statistics are samples of one of their base statistics over an interval the management station specifies, so they're rate based ๐ the management station also picks how many hosts get reported ๐ this group consists of the hostTopNControlTable and the hostTopNTable, and requires the implementation of the host group ๐ซถ
2.3.7. The Matrix Group ๐งฉ
the matrix group stores statistics for conversations between sets of two addresses ๐ when the device detects a new conversation, it creates a new entry in its tables ๐ this group consists of the matrixControlTable, the matrixSDTable and the matrixDSTable ๐ท
2.3.8. The Filter Group ๐ง
the filter group lets packets get matched by a filter equation ๐ฏ those matched packets form a data stream that may be captured or may generate events ๐ this group consists of the filterTable and the channelTable ๐ฆ
2.3.9. The Packet Capture Group ๐ฆ
the Packet Capture group lets packets get captured after they flow through a channel ๐ธ this group consists of the bufferControlTable and the captureBufferTable, and requires the implementation of the filter group ๐ซง
2.3.10. The Event Group ๐ฃ
the event group controls the generation and notification of events from this device ๐ this group consists of the eventTable and the logTable ๐
3. Control of Remote Network Monitoring Devices โจ
okay so these devices do a lot of complicated stuff, so the functions usually need user configuration ๐๏ธ in lots of cases a function needs parameters set up for a data collection operation first ๐ the operation can only proceed once those parameters are fully set up ๐ฆ
Lots of functional groups in this MIB have one or more tables for setting up control parameters ๐๏ธ and one or more data tables where the results land ๐ the control tables are typically read-write, while the data tables are typically read-only ๐ here's the tea: the parameters in a control table often describe the resulting data in the data table, so a lot of those parameters can only be modified when the control entry is invalid ๐ so the way to change them is to invalidate the control entry, which deletes it along with any associated data entries, and then create a new control entry with the proper parameters ๐ deleting the control entry is also a handy way to reclaim the resources the associated data was using โป๏ธ
Some objects in this MIB can trigger an action on the remote monitoring device โก those objects may execute an action because of a change in the state of the object ๐ง for those objects in this MIB, a request to set an object to the value it already holds would cause no action to occur ๐ โโ๏ธ
To make control by multiple managers work, resources have to be shared among the managers ๐ค these resources are typically the memory and computation resources a function requires ๐พ
3.1. Resource Sharing Among Multiple Management Stations ๐ซฑ๐ปโ๐ซฒ๐ฝ
when multiple management stations want to use functions that compete for a finite amount of resources on a device, a method to facilitate sharing those resources is required ๐ potential conflicts include:
- Two management stations wish to simultaneously use resources that together would exceed the capability of the device. ๐ฌ
- A management station uses a significant amount of resources for a long period of time. โณ
- A management station uses resources and then crashes, forgetting to free the resources so others may use them. ๐
a mechanism is provided for each management station initiated function in this MIB to avoid these conflicts and help resolve them when they happen ๐ ๏ธ each function has a label identifying the initiator (owner) of the function ๐ท๏ธ the initiator sets this label to allow for the following possibilities:
- A management station may recognize resources it owns and no longer needs. ๐
- A network operator can find the management station that owns the resource and negotiate for it to be freed. ๐ค
- A network operator may decide to unilaterally free resources another network operator has reserved. ๐
- Upon initialization, a management station may recognize resources it had reserved in the past. With this information it may free the resources if it no longer needs them. ๐งน
management stations and probes should support any format of the owner string dictated by the local policy of the organization ๐ it's suggested that this name contain one or more of the following: IP address, management station name, network manager's name, location, or phone number ๐ this info helps users share resources more effectively ๐ซถ
there's often default functionality that the device or the administrator of the probe (often the network administrator) wants to set up ๐๏ธ the resources tied to that functionality are then owned by the device itself or by the network administrator, and they're meant to be long-lived ๐ฐ๏ธ in this case, the device or the administrator sets the relevant owner object to a string starting with 'monitor' ๐ indiscriminate modification of the monitor-owned configuration by network management stations is discouraged ๐ โโ๏ธ in fact, a network management station should only modify these objects under the direction of the administrator of the probe ๐ซก
resources on a probe are scarce and are typically allocated when control rows are created by an application ๐ฎโ๐จ since many applications may be using a probe at the same time, indiscriminate allocation of resources to particular applications is very likely to cause resource shortages in the probe ๐จ
when a network management station wants to use a function in a monitor, it is encouraged to first scan the control table of that function to find an instance with similar parameters to share ๐ this is especially true for instances owned by the monitor, which can be assumed to change infrequently ๐ข if a management station decides to share an instance owned by another management station, it should understand that the management station that owns the instance may indiscriminately modify or delete it โ ๏ธ
it should be noted that a management application should have the most trust in a monitor-owned row, because it should be changed very infrequently ๐ a row owned by the management application is less long-lived, because a network administrator is more likely to re-assign resources from a row in use by one user than from a monitor-owned row that's potentially in use by many users ๐งโ๐คโ๐ง a row owned by another application would be even less long-lived, because that application may delete or modify the row completely at its discretion ๐
3.2. Row Addition Among Multiple Management Stations โ
adding new rows is achieved using the method described in RFC 1905 [13] โ in this MIB, rows are often added to a table to configure a function ๐งโ๐ง this configuration usually involves parameters that control how the function operates ๐๏ธ the agent must check these parameters to make sure they're appropriate given the restrictions defined in this MIB, as well as any implementation specific restrictions such as lack of resources ๐ง the agent implementor may be confused about when to check these parameters and when to signal the management station that they're invalid ๐ตโ๐ซ there are two opportunities:
- When the management station sets each parameter object. ๐ฏ
- When the management station sets the entry status object to valid. โ๏ธ
if the latter is chosen, it would be unclear to the management station which of the several parameters was invalid and caused the badValue error to be emitted ๐คทโโ๏ธ so wherever possible, the implementor should choose the former, since it gives the management station more information ๐ง
a problem can come up when multiple management stations try to set configuration information at the same time using SNMP ๐ฅด when this involves adding a new conceptual row to the same control table, the managers may collide, all trying to create the same entry ๐ฅ to guard against these collisions, each such control entry contains a status object with special semantics that help arbitrate among the managers ๐ก๏ธ if an attempt is made with the row addition mechanism to create such a status object and that object already exists, an error is returned โ when more than one manager tries to create the same conceptual row at once, only the first can succeed ๐ฅ the others will get an error ๐ญ
when a manager wants to create a new control entry, it needs to choose an index for that row ๐ข it can choose this index in a variety of ways, hopefully minimizing the chances that the index is already in use by another manager ๐ค if the index is in use, the mechanism mentioned previously will guard against collisions ๐งฑ examples of schemes for choosing index values include random selection or scanning the control table for the first unused index ๐ฒ because index values may be any valid value in the range and they're chosen by the manager, the agent must allow a row to be created with any unused index value if it has the resources to create a new row ๐ซถ
some tables in this MIB reference other tables within this MIB ๐ when creating or deleting entries in these tables, it's generally allowable for dangling references to exist ๐ชข there is no defined order for creating or deleting entries in these tables ๐
4. Conventions โจ
okay so these are the ground rules that the whole RMON MIB and its companion docs run on, bestie ๐ everything else builds on this, so let's get it right.
Good Packets
Good packets are the error-free ones with a valid frame length ๐ For Ethernet, that means error-free packets between 64 octets long and 1518 octets long. They follow the form defined in IEEE 802.3 section 3.2.all ๐ง
Bad Packets
Bad packets are a little messier ๐ They have proper framing, so the device recognizes them as packets, but they have errors inside or an invalid length. On Ethernet, a bad packet has a valid preamble and SFD but a bad CRC, or it's shorter than 64 octets or longer than 1518 octets. Not me having to keep track of all of this ๐
5. Definitions โจ
bestie, this is where the actual MIB lives ๐ It's long and very detailed, so here's the whole thing exactly as it's written:
RMON-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY,
NOTIFICATION-TYPE, mib-2, Counter32,
Integer32, TimeTicks FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP FROM SNMPv2-CONF;
-- Remote Network Monitoring MIB
rmonMibModule MODULE-IDENTITY
LAST-UPDATED "200005110000Z" -- 11 May, 2000
ORGANIZATION "IETF RMON MIB Working Group"
CONTACT-INFO
"Steve Waldbusser
Phone: +1-650-948-6500
Fax: +1-650-745-0671
Email: waldbusser@nextbeacon.com"
DESCRIPTION
"Remote network monitoring devices, often called
monitors or probes, are instruments that exist for
the purpose of managing a network. This MIB defines
objects for managing remote network monitoring devices."
REVISION "200005110000Z" -- 11 May, 2000
DESCRIPTION
"Reformatted into SMIv2 format.
This version published as RFC 2819."
REVISION "199502010000Z" -- 1 Feb, 1995
DESCRIPTION
"Bug fixes, clarifications and minor changes based on
implementation experience, published as RFC1757 [18].
Two changes were made to object definitions:
1) A new status bit has been defined for the
captureBufferPacketStatus object, indicating that the
packet order within the capture buffer may not be identical to
the packet order as received off the wire. This bit may only
be used for packets transmitted by the probe. Older NMS
applications can safely ignore this status bit, which might be
used by newer agents.
2) The packetMatch trap has been removed. This trap was never
actually 'approved' and was not added to this document along
with the risingAlarm and fallingAlarm traps. The packetMatch
trap could not be throttled, which could cause disruption of
normal network traffic under some circumstances. An NMS should
configure a risingAlarm threshold on the appropriate
channelMatches instance if a trap is desired for a packetMatch
event. Note that logging of packetMatch events is still
supported--only trap generation for such events has been
removed.
In addition, several clarifications to individual object
definitions have been added to assist agent and NMS
implementors:
- global definition of 'good packets' and 'bad packets'
- more detailed text governing conceptual row creation and
modification
- instructions for probes relating to interface changes and
disruptions
- clarification of some ethernet counter definitions
- recommended formula for calculating network utilization
- clarification of channel and captureBuffer behavior for some
unusual conditions
- examples of proper instance naming for each table"
REVISION "199111010000Z" -- 1 Nov, 1991
DESCRIPTION
"The original version of this MIB, published as RFC1271."
::= { rmonConformance 8 }
rmon OBJECT IDENTIFIER ::= { mib-2 16 }
-- textual conventions
OwnerString ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This data type is used to model an administratively
assigned name of the owner of a resource. Implementations
must accept values composed of well-formed NVT ASCII
sequences. In addition, implementations should accept
values composed of well-formed UTF-8 sequences.
It is suggested that this name contain one or more of
the following: IP address, management station name,
network manager's name, location, or phone number.
In some cases the agent itself will be the owner of
an entry. In these cases, this string shall be set
to a string starting with 'monitor'.
SNMP access control is articulated entirely in terms
of the contents of MIB views; access to a particular
SNMP object instance depends only upon its presence
or absence in a particular MIB view and never upon
its value or the value of related object instances.
Thus, objects of this type afford resolution of
resource contention only among cooperating
managers; they realize no access control function
with respect to uncooperative parties."
SYNTAX OCTET STRING (SIZE (0..127))
EntryStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The status of a table entry.
Setting this object to the value invalid(4) has the
effect of invalidating the corresponding entry.
That is, it effectively disassociates the mapping
identified with said entry.
It is an implementation-specific matter as to whether
the agent removes an invalidated entry from the table.
Accordingly, management stations must be prepared to
receive tabular information from agents that corresponds
to entries currently not in use. Proper
interpretation of such entries requires examination
of the relevant EntryStatus object.
An existing instance of this object cannot be set to
createRequest(2). This object may only be set to
createRequest(2) when this instance is created. When
this object is created, the agent may wish to create
supplemental object instances with default values
to complete a conceptual row in this table. Because the
creation of these default objects is entirely at the option
of the agent, the manager must not assume that any will be
created, but may make use of any that are created.
Immediately after completing the create operation, the agent
must set this object to underCreation(3).
When in the underCreation(3) state, an entry is allowed to
exist in a possibly incomplete, possibly inconsistent state,
usually to allow it to be modified in multiple PDUs. When in
this state, an entry is not fully active.
Entries shall exist in the underCreation(3) state until
the management station is finished configuring the entry
and sets this object to valid(1) or aborts, setting this
object to invalid(4). If the agent determines that an
entry has been in the underCreation(3) state for an
abnormally long time, it may decide that the management
station has crashed. If the agent makes this decision,
it may set this object to invalid(4) to reclaim the
entry. A prudent agent will understand that the
management station may need to wait for human input
and will allow for that possibility in its
determination of this abnormally long period.
An entry in the valid(1) state is fully configured and
consistent and fully represents the configuration or
operation such a row is intended to represent. For
example, it could be a statistical function that is
configured and active, or a filter that is available
in the list of filters processed by the packet capture
process.
A manager is restricted to changing the state of an entry in
the following ways:
To: valid createRequest underCreation invalid
From:
valid OK NO OK OK
createRequest N/A N/A N/A N/A
underCreation OK NO OK OK
invalid NO NO NO OK
nonExistent NO OK NO OK
In the table above, it is not applicable to move the state
from the createRequest state to any other state because the
manager will never find the variable in that state. The
nonExistent state is not a value of the enumeration, rather
it means that the entryStatus variable does not exist at all.
An agent may allow an entryStatus variable to change state in
additional ways, so long as the semantics of the states are
followed. This allowance is made to ease the implementation of
the agent and is made despite the fact that managers should
never exercise these additional state transitions."
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
statistics OBJECT IDENTIFIER ::= { rmon 1 }
history OBJECT IDENTIFIER ::= { rmon 2 }
alarm OBJECT IDENTIFIER ::= { rmon 3 }
hosts OBJECT IDENTIFIER ::= { rmon 4 }
hostTopN OBJECT IDENTIFIER ::= { rmon 5 }
matrix OBJECT IDENTIFIER ::= { rmon 6 }
filter OBJECT IDENTIFIER ::= { rmon 7 }
capture OBJECT IDENTIFIER ::= { rmon 8 }
event OBJECT IDENTIFIER ::= { rmon 9 }
rmonConformance OBJECT IDENTIFIER ::= { rmon 20 }
-- The Ethernet Statistics Group
--
-- Implementation of the Ethernet Statistics group is optional.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The ethernet statistics group contains statistics measured by the
-- probe for each monitored interface on this device. These
-- statistics take the form of free running counters that start from
-- zero when a valid entry is created.
--
-- This group currently has statistics defined only for
-- Ethernet interfaces. Each etherStatsEntry contains statistics
-- for one Ethernet interface. The probe must create one
-- etherStats entry for each monitored Ethernet interface
-- on the device.
etherStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtherStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Ethernet statistics entries."
::= { statistics 1 }
etherStatsEntry OBJECT-TYPE
SYNTAX EtherStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of statistics kept for a particular
Ethernet interface. As an example, an instance of the
etherStatsPkts object might be named etherStatsPkts.1"
INDEX { etherStatsIndex }
::= { etherStatsTable 1 }
okay so this is where the etherStats table really starts to shine ๐ the SEQUENCE below is basically the full list of counters for one Ethernet segment, and it's giving organized โจ
EtherStatsEntry ::= SEQUENCE {
etherStatsIndex Integer32,
etherStatsDataSource OBJECT IDENTIFIER,
etherStatsDropEvents Counter32,
etherStatsOctets Counter32,
etherStatsPkts Counter32,
etherStatsBroadcastPkts Counter32,
etherStatsMulticastPkts Counter32,
etherStatsCRCAlignErrors Counter32,
etherStatsUndersizePkts Counter32,
etherStatsOversizePkts Counter32,
etherStatsFragments Counter32,
etherStatsJabbers Counter32,
etherStatsCollisions Counter32,
etherStatsPkts64Octets Counter32,
etherStatsPkts65to127Octets Counter32,
etherStatsPkts128to255Octets Counter32,
etherStatsPkts256to511Octets Counter32,
etherStatsPkts512to1023Octets Counter32,
etherStatsPkts1024to1518Octets Counter32,
etherStatsOwner OwnerString,
etherStatsStatus EntryStatus
}
okay the first one is the index ๐ฆ it's the unique ID for each etherStats entry, and it's a number from 1 up to 65535. Iconic.
etherStatsIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object uniquely identifies this
etherStats entry."
::= { etherStatsEntry 1 }
next up is the data source ๐ this one is an OBJECT IDENTIFIER that points at the interface you want to watch. The example in the description is literally "ifIndex.1" for interface #1, so you always know exactly which port is getting analyzed. The stats cover every packet on the local segment attached to that interface, not just the ones meant for the probe ๐
There's also a lowkey important warning in here. The agent might not always know if the physical media changed, like when someone yanks out an ethernet card and swaps in a token-ring one. If the agent does know, it's recommended that it invalidate the entry. And the object can't be changed while the status is valid(1) ๐
etherStatsDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the source of the data that
this etherStats entry is configured to analyze. This
source can be any ethernet interface on this device.
In order to identify a particular interface, this object
shall identify the instance of the ifIndex object,
defined in RFC 2233 [17], for the desired interface.
For example, if an entry were to receive data from
interface #1, this object would be set to ifIndex.1.
The statistics in this group reflect all packets
on the local network segment attached to the identified
interface.
An agent may or may not be able to tell if fundamental
changes to the media of the interface have occurred and
necessitate an invalidation of this entry. For example, a
hot-pluggable ethernet card could be pulled out and replaced
by a token-ring card. In such a case, if the agent has such
knowledge of the change, it is recommended that it
invalidate this entry.
This object may not be modified if the associated
etherStatsStatus object is equal to valid(1)."
::= { etherStatsEntry 2 }
the drop events counter is next ๐ it counts how many times the probe had to drop packets because it ran out of resources. The thing to remember is that it counts the events, not the actual number of packets that got dropped. So one event could be a bunch of packets, ngl ๐
etherStatsDropEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of events in which packets
were dropped by the probe due to lack of resources.
Note that this number is not necessarily the number of
packets dropped; it is just the number of times this
condition has been detected."
::= { etherStatsEntry 3 }
okay now the octets counter ๐ this one counts every octet of data that came in, including the ones in bad packets. It leaves out the framing bits but keeps the FCS octets. It's also the one that can give you a rough idea of how busy a 10-Megabit ethernet segment is. If you want something more precise, you sample the octets and packet counters before and after the same interval, then plug those differences into the formula. It's a little math moment but the payoff is worth it โจ
etherStatsOctets OBJECT-TYPE
SYNTAX Counter32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets of data (including
those in bad packets) received on the
network (excluding framing bits but including
FCS octets).
This object can be used as a reasonable estimate of
10-Megabit ethernet utilization. If greater precision is
desired, the etherStatsPkts and etherStatsOctets objects
should be sampled before and after a common interval. The
differences in the sampled values are Pkts and Octets,
respectively, and the number of seconds in the interval is
Interval. These values are used to calculate the Utilization
as follows:
Pkts * (9.6 + 6.4) + (Octets * .8)
Utilization = -------------------------------------
Interval * 10,000
The result of this equation is the value Utilization which
is the percent utilization of the ethernet segment on a
scale of 0 to 100 percent."
::= { etherStatsEntry 4 }
next is the total packet count ๐ฆ every packet that shows up, including the bad ones, plus the broadcast and multicast ones.
etherStatsPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad packets,
broadcast packets, and multicast packets) received."
::= { etherStatsEntry 5 }
broadcast and multicast are separate counters, and they're not the same thing ๐ธ the broadcast one only counts good packets sent to the broadcast address, and it doesn't include multicast. The multicast one is the reverse. It only counts good packets sent to a multicast address, and it doesn't include broadcast. They're besties, but they don't overlap ๐ซถ
etherStatsBroadcastPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of good packets received that were
directed to the broadcast address. Note that this
does not include multicast packets."
::= { etherStatsEntry 6 }
etherStatsMulticastPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of good packets received that were
directed to a multicast address. Note that this number
does not include packets directed to the broadcast
address."
::= { etherStatsEntry 7 }
the CRC and alignment errors counter is for packets between 64 and 1518 octets (inclusive) that have a bad FCS. If the bad FCS has a whole number of octets, it's counted as an FCS error. If it has a non-integral number of octets, it's an alignment error. Very detailed, very on-brand for ethernet ๐ฅ
etherStatsCRCAlignErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that
had a length (excluding framing bits, but
including FCS octets) of between 64 and 1518
octets, inclusive, but had either a bad
Frame Check Sequence (FCS) with an integral
number of octets (FCS Error) or a bad FCS with
a non-integral number of octets (Alignment Error)."
::= { etherStatsEntry 8 }
now the size buckets ๐ง undersized packets are the ones under 64 octets that are otherwise well formed, and oversized packets are the ones over 1518 octets that are also otherwise well formed. Notice how the size counts here don't care about errors, only the "well formed" part matters.
etherStatsUndersizePkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
less than 64 octets long (excluding framing bits,
but including FCS octets) and were otherwise well
formed."
::= { etherStatsEntry 9 }
etherStatsOversizePkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
longer than 1518 octets (excluding framing bits,
but including FCS octets) and were otherwise
well formed."
::= { etherStatsEntry 10 }
fragments are the under-64-octet packets that have a bad FCS, so it's the bad cousin of undersized ๐ the description says it's totally normal for this one to go up, because it counts both runts from collisions and noise hits. Not a crisis, just Ethernet being Ethernet ๐
etherStatsFragments OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were less than
64 octets in length (excluding framing bits but including
FCS octets) and had either a bad Frame Check Sequence
(FCS) with an integral number of octets (FCS Error) or a
bad FCS with a non-integral number of octets (Alignment
Error).
Note that it is entirely normal for etherStatsFragments to
increment. This is because it counts both runts (which are
normal occurrences due to collisions) and noise hits."
::= { etherStatsEntry 11 }
jabbers are the oversized packets with bad FCS ๐ญ the description also says this doesn't match the IEEE-802.3 idea of jabber, which is about packets going over 20 ms. The range the probe uses to detect jabber is 20 ms to 150 ms, so keep that difference in mind if you're comparing numbers across tools ๐
etherStatsJabbers OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
longer than 1518 octets (excluding framing bits,
but including FCS octets), and had either a bad
Frame Check Sequence (FCS) with an integral number
of octets (FCS Error) or a bad FCS with a non-integral
number of octets (Alignment Error).
Note that this definition of jabber is different
than the definition in IEEE-802.3 section 8.2.1.5
(10BASE5) and section 10.3.1.4 (10BASE2). These
documents define jabber as the condition where any
packet exceeds 20 ms. The allowed range to detect
jabber is between 20 ms and 150 ms."
::= { etherStatsEntry 12 }
collisions are the trickiest one ๐ the number you get depends on where the probe is sitting. A station has to detect a collision in receive mode when three or more stations transmit at once, but a repeater port only needs two. So a probe on a repeater port could count more collisions than a probe on a station on the same segment. On 10BASE-T the difference is way smaller, and probes on a station and a repeater should report the same number. And a probe inside a repeater should ideally count transmit collisions plus receiver collisions seen on any coax segments attached to it. It's giving "where you stand matters" ๐
etherStatsCollisions OBJECT-TYPE
SYNTAX Counter32
UNITS "Collisions"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimate of the total number of collisions
on this Ethernet segment.
The value returned will depend on the location of the
RMON probe. Section 8.2.1.3 (10BASE-5) and section
10.3.1.3 (10BASE-2) of IEEE standard 802.3 states that a
station must detect a collision, in the receive mode, if
three or more stations are transmitting simultaneously. A
repeater port must detect a collision when two or more
stations are transmitting simultaneously. Thus a probe
placed on a repeater port could record more collisions
than a probe connected to a station on the same segment
would.
Probe location plays a much smaller role when considering
10BASE-T. 14.2.1.4 (10BASE-T) of IEEE standard 802.3
defines a collision as the simultaneous presence of signals
on the DO and RD circuits (transmitting and receiving
at the same time). A 10BASE-T station can only detect
collisions when it is transmitting. Thus probes placed on
a station and a repeater, should report the same number of
collisions.
Note also that an RMON probe inside a repeater should
ideally report collisions between the repeater and one or
more other hosts (transmit collisions as defined by IEEE
802.3k) plus receiver collisions observed on any coax
segments to which the repeater is connected."
::= { etherStatsEntry 13 }
the last group is the packet size histogram ๐ these buckets count every packet, bad ones included, by its length (with FCS but without framing bits). We've got 64 octets exactly, then 65 to 127, 128 to 255, 256 to 511, and 512 to 1023. The 1024 to 1518 bucket is coming up next, so stay tuned ๐ซถ
etherStatsPkts64Octets OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were 64 octets in length
(excluding framing bits but including FCS octets)."
::= { etherStatsEntry 14 }
etherStatsPkts65to127Octets OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
65 and 127 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { etherStatsEntry 15 }
etherStatsPkts128to255Octets OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
128 and 255 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { etherStatsEntry 16 }
etherStatsPkts256to511Octets OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
256 and 511 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { etherStatsEntry 17 }
etherStatsPkts512to1023Octets OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
512 and 1023 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { etherStatsEntry 18 }
etherStatsPkts1024to1518Octets OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
1024 and 1518 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { etherStatsEntry 19 }
etherStatsOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is therefore
using the resources assigned to it."
::= { etherStatsEntry 20 }
etherStatsStatus OBJECT-TYPE
SYNTAX EntryStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this etherStats entry."
::= { etherStatsEntry 21 }
Okay so the last three etherStats objects are giving main character energy ๐. The packet counter for 1024 to 1518 octets is a Counter32 that counts packets, bad ones included, with framing bits left out but FCS octets counted in ๐ซถ. The owner and status columns are both read-create, and the owner is whoever set up the entry and is therefore using its resources โจ.
-- The History Control Group
-- Implementation of the History Control group is optional.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The history control group controls the periodic statistical
-- sampling of data from various types of networks. The
-- historyControlTable stores configuration entries that each
-- define an interface, polling period, and other parameters.
-- Once samples are taken, their data is stored in an entry
-- in a media-specific table. Each such entry defines one
-- sample, and is associated with the historyControlEntry that
-- caused the sample to be taken. Each counter in the
-- etherHistoryEntry counts the same event as its similarly-named
-- counterpart in the etherStatsEntry, except that each value here
-- is a cumulative sum during a sampling period.
--
-- If the probe keeps track of the time of day, it should start
-- the first sample of the history at a time such that
-- when the next hour of the day begins, a sample is
-- started at that instant. This tends to make more
-- user-friendly reports, and enables comparison of reports
-- from different probes that have relatively accurate time
-- of day.
--
-- The probe is encouraged to add two history control entries
-- per monitored interface upon initialization that describe a short
-- term and a long term polling period. Suggested parameters are 30
-- seconds for the short term polling period and 30 minutes for
-- the long term period.
historyControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF HistoryControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of history control entries."
::= { history 1 }
historyControlEntry OBJECT-TYPE
SYNTAX HistoryControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of parameters that set up a periodic sampling of
statistics. As an example, an instance of the
historyControlInterval object might be named
historyControlInterval.2"
INDEX { historyControlIndex }
::= { historyControlTable 1 }
HistoryControlEntry ::= SEQUENCE {
historyControlIndex Integer32,
historyControlDataSource OBJECT IDENTIFIER,
historyControlBucketsRequested Integer32,
historyControlBucketsGranted Integer32,
historyControlInterval Integer32,
historyControlOwner OwnerString,
historyControlStatus EntryStatus
}
Now we're in the History Control Group ๐ง. Bestie, this one is basically the probe's little diary ๐. Implementing it is optional, and the MODULE-COMPLIANCE macro is the place to check what's actually required ๐ . Each history control entry sets up periodic sampling for an interface, and the samples land in a media-specific table, one sample per entry, each tied back to the history control entry that made it. The Ethernet counters mirror the etherStats ones, except here each value is a running total for one sampling period ๐ธ.
There's also a tip about timing. If the probe knows the time of day, it should start the first sample so a new sample begins right as each hour starts, which makes reports easier to read and lets you compare probes with roughly accurate clocks ๐. The probe is encouraged to set up two history control entries per interface when it starts, a short-term one and a long-term one, with suggested periods of 30 seconds and 30 minutes ๐ฆ.
historyControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
historyControl table. Each such entry defines a
set of samples at a particular interval for an
interface on the device."
::= { historyControlEntry 1 }
historyControlDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the source of the data for
which historical data was collected and
placed in a media-specific table on behalf of this
historyControlEntry. This source can be any
interface on this device. In order to identify
a particular interface, this object shall identify
the instance of the ifIndex object, defined
in RFC 2233 [17], for the desired interface.
For example, if an entry were to receive data from
interface #1, this object would be set to ifIndex.1.
The statistics in this group reflect all packets
on the local network segment attached to the identified
interface.
An agent may or may not be able to tell if fundamental
changes to the media of the interface have occurred and
necessitate an invalidation of this entry. For example, a
hot-pluggable ethernet card could be pulled out and replaced
by a token-ring card. In such a case, if the agent has such
knowledge of the change, it is recommended that it
invalidate this entry.
This object may not be modified if the associated
historyControlStatus object is equal to valid(1)."
::= { historyControlEntry 2 }
historyControlBucketsRequested OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The requested number of discrete time intervals
over which data is to be saved in the part of the
media-specific table associated with this
historyControlEntry.
When this object is created or modified, the probe
should set historyControlBucketsGranted as closely to
this object as is possible for the particular probe
implementation and available resources."
DEFVAL { 50 }
::= { historyControlEntry 3 }
historyControlBucketsGranted OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of discrete sampling intervals
over which data shall be saved in the part of
the media-specific table associated with this
historyControlEntry.
When the associated historyControlBucketsRequested
object is created or modified, the probe
should set this object as closely to the requested
value as is possible for the particular
probe implementation and available resources. The
probe must not lower this value except as a result
of a modification to the associated
historyControlBucketsRequested object.
There will be times when the actual number of
buckets associated with this entry is less than
the value of this object. In this case, at the
end of each sampling interval, a new bucket will
be added to the media-specific table.
When the number of buckets reaches the value of
this object and a new bucket is to be added to the
media-specific table, the oldest bucket associated
with this historyControlEntry shall be deleted by
the agent so that the new bucket can be added.
When the value of this object changes to a value less
than the current value, entries are deleted
from the media-specific table associated with this
historyControlEntry. Enough of the oldest of these
entries shall be deleted by the agent so that their
number remains less than or equal to the new value of
this object.
When the value of this object changes to a value greater
than the current value, the number of associated media-
specific entries may be allowed to grow."
::= { historyControlEntry 4 }
historyControlInterval OBJECT-TYPE
SYNTAX Integer32 (1..3600)
UNITS "Seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The interval in seconds over which the data is
sampled for each bucket in the part of the
media-specific table associated with this
historyControlEntry. This interval can
be set to any number of seconds between 1 and
3600 (1 hour).
Because the counters in a bucket may overflow at their
maximum value with no indication, a prudent manager will
take into account the possibility of overflow in any of
the associated counters. It is important to consider the
minimum time in which any counter could overflow on a
particular media type and set the historyControlInterval
object to a value less than this interval. This is
typically most important for the 'octets' counter in any
media-specific table. For example, on an Ethernet
network, the etherHistoryOctets counter could overflow
in about one hour at the Ethernet's maximum
utilization.
This object may not be modified if the associated
historyControlStatus object is equal to valid(1)."
DEFVAL { 1800 }
::= { historyControlEntry 5 }
historyControlOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is therefore
using the resources assigned to it."
::= { historyControlEntry 6 }
historyControlStatus OBJECT-TYPE
SYNTAX EntryStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this historyControl entry.
Each instance of the media-specific table associated
with this historyControlEntry will be deleted by the agent
if this historyControlEntry is not equal to valid(1)."
::= { historyControlEntry 7 }
Okay the historyControl columns are where the drama is ๐. The index is just a unique ID for each entry, and each one defines a set of samples at a particular interval for an interface on the device ๐. The data source is an ifIndex instance pointing at the interface, like ifIndex.1 for interface #1, and it can't be changed while the status is valid(1) ๐ . The statistics cover every packet on the local network segment attached to that interface ๐.
Agents might not always know if the interface media changed under them, like a hot-pluggable card getting swapped for a totally different type. If the agent does know, it is recommended that it invalidate the entry ๐.
For buckets, the requested count defaults to 50 and the probe should get as close to it as it can, but the granted count is what it actually saves ๐งบ. The probe must not lower the granted value unless the requested one gets modified. When the buckets are full, the oldest one gets deleted to make room, and if the count goes down, the oldest extras get deleted too. If it goes up, the media-specific entries may be allowed to grow ๐.
The interval is in seconds, anywhere from 1 up to 3600 (one hour), and it defaults to 1800 โฑ๏ธ. Counters can overflow silently, so a prudent manager should think about how fast each counter could overflow on the media type and pick an interval shorter than that. The octets counter is usually the one to watch, and on Ethernet the etherHistoryOctets counter could overflow in about one hour at maximum utilization ๐ญ.
Owner is just the entity that set the entry up, same vibe as before ๐ซถ. And the status column is the boss here: if the history control entry isn't valid(1), every media-specific table instance tied to it gets deleted by the agent ๐.
-- The Ethernet History Group
-- Implementation of the Ethernet History group is optional.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The Ethernet History group records periodic statistical samples
-- from a network and stores them for later retrieval.
-- Once samples are taken, their data is stored in an entry
-- in a media-specific table. Each such entry defines one
-- sample, and is associated with the historyControlEntry that
-- caused the sample to be taken. This group defines the
-- etherHistoryTable, for Ethernet networks.
--
etherHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtherHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Ethernet history entries."
::= { history 2 }
etherHistoryEntry OBJECT-TYPE
SYNTAX EtherHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An historical sample of Ethernet statistics on a particular
Ethernet interface. This sample is associated with the
historyControlEntry which set up the parameters for
a regular collection of these samples. As an example, an
instance of the etherHistoryPkts object might be named
etherHistoryPkts.2.89"
INDEX { etherHistoryIndex , etherHistorySampleIndex }
::= { etherHistoryTable 1 }
Last stop for this bit is the Ethernet History Group ๐. Implementing it is optional too, and it's where the periodic Ethernet samples get recorded and stored so you can pull them back out later ๐. Each sample lives in a media-specific table and is tied to the history control entry that triggered it, and this group defines the etherHistoryTable for Ethernet networks โจ. Each sample is identified by an index and a sample index together, so an etherHistoryPkts instance can look like etherHistoryPkts.2.89 ๐.
okay bestie, we're back in the MIB and this part is giving data-hoarding energy ๐โจ
EtherHistoryEntry ::= SEQUENCE {
etherHistoryIndex Integer32,
etherHistorySampleIndex Integer32,
etherHistoryIntervalStart TimeTicks,
etherHistoryDropEvents Counter32,
etherHistoryOctets Counter32,
etherHistoryPkts Counter32,
etherHistoryBroadcastPkts Counter32,
etherHistoryMulticastPkts Counter32,
etherHistoryCRCAlignErrors Counter32,
etherHistoryUndersizePkts Counter32,
etherHistoryOversizePkts Counter32,
etherHistoryFragments Counter32,
etherHistoryJabbers Counter32,
etherHistoryCollisions Counter32,
etherHistoryUtilization Integer32
}
etherHistoryIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The history of which this entry is a part. The
history identified by a particular value of this
index is the same history as identified
by the same value of historyControlIndex."
::= { etherHistoryEntry 1 }
etherHistorySampleIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies the particular
sample this entry represents among all samples
associated with the same historyControlEntry.
This index starts at 1 and increases by one
as each new sample is taken."
::= { etherHistoryEntry 2 }
etherHistoryIntervalStart OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the start of the interval
over which this sample was measured. If the probe
keeps track of the time of day, it should start
the first sample of the history at a time such that
when the next hour of the day begins, a sample is
started at that instant. Note that following this
rule may require the probe to delay collecting the
first sample of the history, as each sample must be
of the same interval. Also note that the sample which
is currently being collected is not accessible in this
table until the end of its interval."
::= { etherHistoryEntry 3 }
etherHistoryDropEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of events in which packets
were dropped by the probe due to lack of resources
during this sampling interval. Note that this number
is not necessarily the number of packets dropped, it
is just the number of times this condition has been
detected."
::= { etherHistoryEntry 4 }
etherHistoryOctets OBJECT-TYPE
SYNTAX Counter32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets of data (including
those in bad packets) received on the
network (excluding framing bits but including
FCS octets)."
::= { etherHistoryEntry 5 }
etherHistoryPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets (including bad packets)
received during this sampling interval."
::= { etherHistoryEntry 6 }
etherHistoryBroadcastPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of good packets received during this
sampling interval that were directed to the
broadcast address."
::= { etherHistoryEntry 7 }
etherHistoryMulticastPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of good packets received during this
sampling interval that were directed to a
multicast address. Note that this number does not
include packets addressed to the broadcast address."
::= { etherHistoryEntry 8 }
etherHistoryCRCAlignErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets received during this
sampling interval that had a length (excluding
framing bits but including FCS octets) between
64 and 1518 octets, inclusive, but had either a bad Frame
Check Sequence (FCS) with an integral number of octets
(FCS Error) or a bad FCS with a non-integral number
of octets (Alignment Error)."
::= { etherHistoryEntry 9 }
etherHistoryUndersizePkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets received during this
sampling interval that were less than 64 octets
long (excluding framing bits but including FCS
octets) and were otherwise well formed."
::= { etherHistoryEntry 10 }
etherHistoryOversizePkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets received during this
sampling interval that were longer than 1518
octets (excluding framing bits but including
FCS octets) but were otherwise well formed."
::= { etherHistoryEntry 11 }
etherHistoryFragments OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received during this
sampling interval that were less than 64 octets in
length (excluding framing bits but including FCS
octets) had either a bad Frame Check Sequence (FCS)
with an integral number of octets (FCS Error) or a bad
FCS with a non-integral number of octets (Alignment
Error).
Note that it is entirely normal for etherHistoryFragments to
increment. This is because it counts both runts (which are
normal occurrences due to collisions) and noise hits."
::= { etherHistoryEntry 12 }
etherHistoryJabbers OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets received during this
sampling interval that were longer than 1518 octets
(excluding framing bits but including FCS octets),
and had either a bad Frame Check Sequence (FCS)
with an integral number of octets (FCS Error) or
a bad FCS with a non-integral number of octets
(Alignment Error).
Note that this definition of jabber is different
than the definition in IEEE-802.3 section 8.2.1.5
(10BASE5) and section 10.3.1.4 (10BASE2). These
documents define jabber as the condition where any
packet exceeds 20 ms. The allowed range to detect
jabber is between 20 ms and 150 ms."
::= { etherHistoryEntry 13 }
etherHistoryCollisions OBJECT-TYPE
SYNTAX Counter32
UNITS "Collisions"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimate of the total number of collisions
on this Ethernet segment during this sampling
interval.
The value returned will depend on the location of the
RMON probe. Section 8.2.1.3 (10BASE-5) and section
10.3.1.3 (10BASE-2) of IEEE standard 802.3 states that a
station must detect a collision, in the receive mode, if
three or more stations are transmitting simultaneously. A
repeater port must detect a collision when two or more
stations are transmitting simultaneously. Thus a probe
placed on a repeater port could record more collisions
than a probe connected to a station on the same segment
would.
Probe location plays a much smaller role when considering
10BASE-T. 14.2.1.4 (10BASE-T) of IEEE standard 802.3
defines a collision as the simultaneous presence of signals
on the DO and RD circuits (transmitting and receiving
at the same time). A 10BASE-T station can only detect
collisions when it is transmitting. Thus probes placed on
a station and a repeater, should report the same number of
collisions.
Note also that an RMON probe inside a repeater should
ideally report collisions between the repeater and one or
more other hosts (transmit collisions as defined by IEEE
802.3k) plus receiver collisions observed on any coax
segments to which the repeater is connected."
::= { etherHistoryEntry 14 }
etherHistoryUtilization OBJECT-TYPE
SYNTAX Integer32 (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimate of the mean physical layer
network utilization on this interface during this
sampling interval, in hundredths of a percent."
::= { etherHistoryEntry 15 }
the etherHistory objects are basically the probe writing down its notes sample by sample ๐ง every row has an index pair that tells you which history and which sample it belongs to, and the counters are the good stuff ๐
now we're in the Alarm Group ๐จ this is the probe keeping an eye on variables and getting a little dramatic when they cross a line. the alarm table holds the setup for each watch, like which variable, how often to check, and where the thresholds sit ๐
-- The Alarm Group
-- Implementation of the Alarm group is optional. The Alarm Group
-- requires the implementation of the Event group.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The Alarm group periodically takes statistical samples from
-- variables in the probe and compares them to thresholds that have
-- been configured. The alarm table stores configuration
-- entries that each define a variable, polling period, and
-- threshold parameters. If a sample is found to cross the
-- threshold values, an event is generated. Only variables that
-- resolve to an ASN.1 primitive type of INTEGER (INTEGER, Integer32,
-- Counter32, Counter64, Gauge32, or TimeTicks) may be monitored in
-- this way.
--
-- This function has a hysteresis mechanism to limit the generation
-- of events. This mechanism generates one event as a threshold
-- is crossed in the appropriate direction. No more events are
-- generated for that threshold until the opposite threshold is
-- crossed.
--
-- In the case of a sampling a deltaValue, a probe may implement
-- this mechanism with more precision if it takes a delta sample
-- twice per period, each time comparing the sum of the latest two
-- samples to the threshold. This allows the detection of threshold
-- crossings that span the sampling boundary. Note that this does
-- not require any special configuration of the threshold value.
-- It is suggested that probes implement this more precise algorithm.
so the hysteresis thing is lowkey genius ๐ง one alert when a threshold gets crossed in the right direction, then radio silence until it crosses the other way. no spam, just vibes ๐ซถ
alarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of alarm entries."
::= { alarm 1 }
alarmEntry OBJECT-TYPE
SYNTAX AlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of parameters that set up a periodic checking
for alarm conditions. For example, an instance of the
alarmValue object might be named alarmValue.8"
INDEX { alarmIndex }
::= { alarmTable 1 }
Okay bestie, the alarm table is all about setting up thresholds that go off like a little alarm bell ๐๐ Here's the full definition, exactly as the spec has it:
AlarmEntry ::= SEQUENCE {
alarmIndex Integer32,
alarmInterval Integer32,
alarmVariable OBJECT IDENTIFIER,
alarmSampleType INTEGER,
alarmValue Integer32,
alarmStartupAlarm INTEGER,
alarmRisingThreshold Integer32,
alarmFallingThreshold Integer32,
alarmRisingEventIndex Integer32,
alarmFallingEventIndex Integer32,
alarmOwner OwnerString,
alarmStatus EntryStatus
}
alarmIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
alarm table. Each such entry defines a
diagnostic sample at a particular interval
for an object on the device."
::= { alarmEntry 1 }
alarmInterval OBJECT-TYPE
SYNTAX Integer32
UNITS "Seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The interval in seconds over which the data is
sampled and compared with the rising and falling
thresholds. When setting this variable, care
should be taken in the case of deltaValue
sampling - the interval should be set short enough
that the sampled variable is very unlikely to
increase or decrease by more than 2^31 - 1 during
a single sampling interval.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { alarmEntry 2 }
alarmVariable OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The object identifier of the particular variable to be
sampled. Only variables that resolve to an ASN.1 primitive
type of INTEGER (INTEGER, Integer32, Counter32, Counter64,
Gauge, or TimeTicks) may be sampled.
Because SNMP access control is articulated entirely
in terms of the contents of MIB views, no access
control mechanism exists that can restrict the value of
this object to identify only those objects that exist
in a particular MIB view. Because there is thus no
acceptable means of restricting the read access that
could be obtained through the alarm mechanism, the
probe must only grant write access to this object in
those views that have read access to all objects on
the probe.
During a set operation, if the supplied variable name is
not available in the selected MIB view, a badValue error
must be returned. If at any time the variable name of
an established alarmEntry is no longer available in the
selected MIB view, the probe must change the status of
this alarmEntry to invalid(4).
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { alarmEntry 3 }
alarmSampleType OBJECT-TYPE
SYNTAX INTEGER {
absoluteValue(1),
deltaValue(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The method of sampling the selected variable and
calculating the value to be compared against the
thresholds. If the value of this object is
absoluteValue(1), the value of the selected variable
will be compared directly with the thresholds at the
end of the sampling interval. If the value of this
object is deltaValue(2), the value of the selected
variable at the last sample will be subtracted from
the current value, and the difference compared with
the thresholds.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { alarmEntry 4 }
alarmValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the statistic during the last sampling
period. For example, if the sample type is deltaValue,
this value will be the difference between the samples
at the beginning and end of the period. If the sample
type is absoluteValue, this value will be the sampled
value at the end of the period.
This is the value that is compared with the rising and
falling thresholds.
The value during the current sampling period is not
made available until the period is completed and will
remain available until the next period completes."
::= { alarmEntry 5 }
alarmStartupAlarm OBJECT-TYPE
SYNTAX INTEGER {
risingAlarm(1),
fallingAlarm(2),
risingOrFallingAlarm(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The alarm that may be sent when this entry is first
set to valid. If the first sample after this entry
becomes valid is greater than or equal to the
risingThreshold and alarmStartupAlarm is equal to
risingAlarm(1) or risingOrFallingAlarm(3), then a single
rising alarm will be generated. If the first sample
after this entry becomes valid is less than or equal
to the fallingThreshold and alarmStartupAlarm is equal
to fallingAlarm(2) or risingOrFallingAlarm(3), then a
single falling alarm will be generated.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { alarmEntry 6 }
alarmRisingThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A threshold for the sampled statistic. When the current
sampled value is greater than or equal to this threshold,
and the value at the last sampling interval was less than
this threshold, a single event will be generated.
A single event will also be generated if the first
sample after this entry becomes valid is greater than or
equal to this threshold and the associated
alarmStartupAlarm is equal to risingAlarm(1) or
risingOrFallingAlarm(3).
After a rising event is generated, another such event
will not be generated until the sampled value
falls below this threshold and reaches the
alarmFallingThreshold.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { alarmEntry 7 }
alarmFallingThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A threshold for the sampled statistic. When the current
sampled value is less than or equal to this threshold,
and the value at the last sampling interval was greater than
this threshold, a single event will be generated.
A single event will also be generated if the first
sample after this entry becomes valid is less than or
equal to this threshold and the associated
alarmStartupAlarm is equal to fallingAlarm(2) or
risingOrFallingAlarm(3).
After a falling event is generated, another such event
will not be generated until the sampled value
rises above this threshold and reaches the
alarmRisingThreshold.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { alarmEntry 8 }
alarmRisingEventIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The index of the eventEntry that is
used when a rising threshold is crossed. The
eventEntry identified by a particular value of
this index is the same as identified by the same value
of the eventIndex object. If there is no
corresponding entry in the eventTable, then
no association exists. In particular, if this value
is zero, no associated event will be generated, as
zero is not a valid event index.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { alarmEntry 9 }
alarmFallingEventIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The index of the eventEntry that is
used when a falling threshold is crossed. The
eventEntry identified by a particular value of
this index is the same as identified by the same value
of the eventIndex object. If there is no
corresponding entry in the eventTable, then
no association exists. In particular, if this value
is zero, no associated event will be generated, as
zero is not a valid event index.
This object may not be modified if the associated
alarmStatus object is equal to valid(1)."
::= { alarmEntry 10 }
alarmOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is therefore
using the resources assigned to it."
::= { alarmEntry 11 }
alarmStatus OBJECT-TYPE
SYNTAX EntryStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this alarm entry."
::= { alarmEntry 12 }
-- The Host Group
-- Implementation of the Host group is optional.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The host group discovers new hosts on the network by
-- keeping a list of source and destination MAC Addresses seen
-- in good packets. For each of these addresses, the host group
-- keeps a set of statistics. The hostControlTable controls
-- which interfaces this function is performed on, and contains
-- some information about the process. On behalf of each
-- hostControlEntry, data is collected on an interface and placed
-- in both the hostTable and the hostTimeTable. If the
-- monitoring device finds itself short of resources, it may
-- delete entries as needed. It is suggested that the device
-- delete the least recently used entries first.
-- The hostTable contains entries for each address discovered on
-- a particular interface. Each entry contains statistical
-- data about that host. This table is indexed by the
-- MAC address of the host, through which a random access
-- may be achieved.
-- The hostTimeTable contains data in the same format as the
-- hostTable, and must contain the same set of hosts, but is
-- indexed using hostTimeCreationOrder rather than hostAddress.
-- The hostTimeCreationOrder is an integer which reflects
-- the relative order in which a particular entry was discovered
-- and thus inserted into the table. As this order, and thus
-- the index, is among those entries currently in the table,
-- the index for a particular entry may change if an
-- (earlier) entry is deleted. Thus the association between
-- hostTimeCreationOrder and hostTimeEntry may be broken at
-- any time.
-- The hostTimeTable has two important uses. The first is the
-- fast download of this potentially large table. Because the
-- index of this table runs from 1 to the size of the table,
-- inclusive, its values are predictable. This allows very
-- efficient packing of variables into SNMP PDU's and allows
-- a table transfer to have multiple packets outstanding.
-- These benefits increase transfer rates tremendously.
okay so this bit is where the host table gets its superpowers ๐ The management station can keep track of new rows and notice when old ones get deleted.
-- The second use of the hostTimeTable is the efficient discovery
-- by the management station of new entries added to the table.
-- After the management station has downloaded the entire table,
-- it knows that new entries will be added immediately after the
-- end of the current table. It can thus detect new entries there
-- and retrieve them easily.
-- Because the association between hostTimeCreationOrder and
-- hostTimeEntry may be broken at any time, the management
-- station must monitor the related hostControlLastDeleteTime
-- object. When the management station thus detects a deletion,
-- it must assume that any such associations have been broken,
-- and invalidate any it has stored locally. This includes
-- restarting any download of the hostTimeTable that may have been
-- in progress, as well as rediscovering the end of the
-- hostTimeTable so that it may detect new entries. If the
-- management station does not detect the broken association,
-- it may continue to refer to a particular host by its
-- creationOrder while unwittingly retrieving the data associated
-- with another host entirely. If this happens while downloading
-- the host table, the management station may fail to download
-- all of the entries in the table.
ngl the "association may be broken at any time" part is giving high-stakes drama ๐ญ So if the manager sees hostControlLastDeleteTime move, it has to treat its saved links as busted and throw them out. Otherwise it could be looking at a totally different host's numbers while thinking it's on the right one ๐
hostControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF HostControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of host table control entries."
::= { hosts 1 }
hostControlEntry OBJECT-TYPE
SYNTAX HostControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of parameters that set up the discovery of hosts
on a particular interface and the collection of statistics
about these hosts. For example, an instance of the
hostControlTableSize object might be named
hostControlTableSize.1"
INDEX { hostControlIndex }
::= { hostControlTable 1 }
HostControlEntry ::= SEQUENCE {
hostControlIndex Integer32,
hostControlDataSource OBJECT IDENTIFIER,
hostControlTableSize Integer32,
hostControlLastDeleteTime TimeTicks,
hostControlOwner OwnerString,
hostControlStatus EntryStatus
}
hostControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
hostControl table. Each such entry defines
a function that discovers hosts on a particular interface
and places statistics about them in the hostTable and
the hostTimeTable on behalf of this hostControlEntry."
::= { hostControlEntry 1 }
hostControlDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the source of the data for
this instance of the host function. This source
can be any interface on this device. In order
to identify a particular interface, this object shall
identify the instance of the ifIndex object, defined
in RFC 2233 [17], for the desired interface.
For example, if an entry were to receive data from
interface #1, this object would be set to ifIndex.1.
The statistics in this group reflect all packets
on the local network segment attached to the identified
interface.
An agent may or may not be able to tell if fundamental
changes to the media of the interface have occurred and
necessitate an invalidation of this entry. For example, a
hot-pluggable ethernet card could be pulled out and replaced
by a token-ring card. In such a case, if the agent has such
knowledge of the change, it is recommended that it
invalidate this entry.
This object may not be modified if the associated
hostControlStatus object is equal to valid(1)."
::= { hostControlEntry 2 }
hostControlTableSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of hostEntries in the hostTable and the
hostTimeTable associated with this hostControlEntry."
::= { hostControlEntry 3 }
hostControlLastDeleteTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the last entry
was deleted from the portion of the hostTable
associated with this hostControlEntry. If no
deletions have occurred, this value shall be zero."
::= { hostControlEntry 4 }
hostControlOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is therefore
using the resources assigned to it."
::= { hostControlEntry 5 }
hostControlStatus OBJECT-TYPE
SYNTAX EntryStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this hostControl entry.
If this object is not equal to valid(1), all associated
entries in the hostTable, hostTimeTable, and the
hostTopNTable shall be deleted by the agent."
::= { hostControlEntry 6 }
okay the hostControl table is basically the boss of everything ๐ It decides which interface gets watched, keeps count of the hosts, and even has an owner field so you know who set it up ๐ซถ and if hostControlStatus isn't valid(1), the agent has to delete all the related rows in the hostTable, hostTimeTable and hostTopNTable. no cap, that's a whole clean-up crew ๐งน
hostTable OBJECT-TYPE
SYNTAX SEQUENCE OF HostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of host entries."
::= { hosts 2 }
hostEntry OBJECT-TYPE
SYNTAX HostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of statistics for a particular host that has
been discovered on an interface of this device. For example,
an instance of the hostOutBroadcastPkts object might be
named hostOutBroadcastPkts.1.6.8.0.32.27.3.176"
INDEX { hostIndex, hostAddress }
::= { hostTable 1 }
HostEntry ::= SEQUENCE {
hostAddress OCTET STRING,
hostCreationOrder Integer32,
hostIndex Integer32,
hostInPkts Counter32,
hostOutPkts Counter32,
hostInOctets Counter32,
hostOutOctets Counter32,
hostOutErrors Counter32,
hostOutBroadcastPkts Counter32,
hostOutMulticastPkts Counter32
}
hostAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The physical address of this host."
::= { hostEntry 1 }
hostCreationOrder OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that defines the relative ordering of
the creation time of hosts captured for a
particular hostControlEntry. This index shall
be between 1 and N, where N is the value of
the associated hostControlTableSize. The ordering
of the indexes is based on the order of each entry's
insertion into the table, in which entries added earlier
have a lower index value than entries added later.
It is important to note that the order for a
particular entry may change as an (earlier) entry
is deleted from the table. Because this order may
change, management stations should make use of the
hostControlLastDeleteTime variable in the
hostControlEntry associated with the relevant
portion of the hostTable. By observing
this variable, the management station may detect
the circumstances where a previous association
between a value of hostCreationOrder
and a hostEntry may no longer hold."
::= { hostEntry 2 }
hostIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The set of collected host statistics of which
this entry is a part. The set of hosts
identified by a particular value of this
index is associated with the hostControlEntry
as identified by the same value of hostControlIndex."
::= { hostEntry 3 }
hostInPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of good packets transmitted to this
address since it was added to the hostTable."
::= { hostEntry 4 }
hostOutPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, including bad packets, transmitted
by this address since it was added to the hostTable."
::= { hostEntry 5 }
hostInOctets OBJECT-TYPE
SYNTAX Counter32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets transmitted to this address since
it was added to the hostTable (excluding framing
bits but including FCS octets), except for those
octets in bad packets."
::= { hostEntry 6 }
hostOutOctets OBJECT-TYPE
SYNTAX Counter32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets transmitted by this address since
it was added to the hostTable (excluding framing
bits but including FCS octets), including those
octets in bad packets."
::= { hostEntry 7 }
hostOutErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bad packets transmitted by this address
since this host was added to the hostTable."
::= { hostEntry 8 }
hostOutBroadcastPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of good packets transmitted by this
address that were directed to the broadcast address
since this host was added to the hostTable."
::= { hostEntry 9 }
hostOutMulticastPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of good packets transmitted by this
address that were directed to a multicast address
since this host was added to the hostTable.
Note that this number does not include packets
directed to the broadcast address."
::= { hostEntry 10 }
the hostTable is where all the host stats live, bestie ๐ hostCreationOrder is kinda the sneaky one ๐ Its number can shift when an earlier row gets deleted, which is exactly why the management station has to keep an eye on hostControlLastDeleteTime ๐ฆ
-- host Time Table
hostTimeTable OBJECT-TYPE
SYNTAX SEQUENCE OF HostTimeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of time-ordered host table entries."
::= { hosts 3 }
hostTimeEntry OBJECT-TYPE
SYNTAX HostTimeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of statistics for a particular host that has
been discovered on an interface of this device. This
collection includes the relative ordering of the creation
time of this object. For example, an instance of the
hostTimeOutBroadcastPkts object might be named
hostTimeOutBroadcastPkts.1.687"
INDEX { hostTimeIndex, hostTimeCreationOrder }
::= { hostTimeTable 1 }
okay bestie, first up is the hostTimeEntry ๐ง it's one row of the hostTimeTable, with ten columns, and every single one is read-only, so managers can look but not touch ๐
HostTimeEntry ::= SEQUENCE {
hostTimeAddress OCTET STRING,
hostTimeCreationOrder Integer32,
hostTimeIndex Integer32,
hostTimeInPkts Counter32,
hostTimeOutPkts Counter32,
hostTimeInOctets Counter32,
hostTimeOutOctets Counter32,
hostTimeOutErrors Counter32,
hostTimeOutBroadcastPkts Counter32,
hostTimeOutMulticastPkts Counter32
}
hostTimeAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The physical address of this host."
::= { hostTimeEntry 1 }
hostTimeCreationOrder OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in
the hostTime table among those entries associated
with the same hostControlEntry. This index shall
be between 1 and N, where N is the value of
the associated hostControlTableSize. The ordering
of the indexes is based on the order of each entry's
insertion into the table, in which entries added earlier
have a lower index value than entries added later.
Thus the management station has the ability to
learn of new entries added to this table without
downloading the entire table.
It is important to note that the index for a
particular entry may change as an (earlier) entry
is deleted from the table. Because this order may
change, management stations should make use of the
hostControlLastDeleteTime variable in the
hostControlEntry associated with the relevant
portion of the hostTimeTable. By observing
this variable, the management station may detect
the circumstances where a download of the table
may have missed entries, and where a previous
association between a value of hostTimeCreationOrder
and a hostTimeEntry may no longer hold."
::= { hostTimeEntry 2 }
hostTimeIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The set of collected host statistics of which
this entry is a part. The set of hosts
identified by a particular value of this
index is associated with the hostControlEntry
as identified by the same value of hostControlIndex."
::= { hostTimeEntry 3 }
hostTimeInPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of good packets transmitted to this
address since it was added to the hostTimeTable."
::= { hostTimeEntry 4 }
hostTimeOutPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, including bad packets, transmitted
by this address since it was added to the hostTimeTable."
::= { hostTimeEntry 5 }
hostTimeInOctets OBJECT-TYPE
SYNTAX Counter32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets transmitted to this address since
it was added to the hostTimeTable (excluding framing
bits but including FCS octets), except for those
octets in bad packets."
::= { hostTimeEntry 6 }
hostTimeOutOctets OBJECT-TYPE
SYNTAX Counter32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets transmitted by this address since
it was added to the hostTimeTable (excluding framing
bits but including FCS octets), including those
octets in bad packets."
::= { hostTimeEntry 7 }
hostTimeOutErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bad packets transmitted by this address
since this host was added to the hostTimeTable."
::= { hostTimeEntry 8 }
hostTimeOutBroadcastPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of good packets transmitted by this
address that were directed to the broadcast address
since this host was added to the hostTimeTable."
::= { hostTimeEntry 9 }
hostTimeOutMulticastPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of good packets transmitted by this
address that were directed to a multicast address
since this host was added to the hostTimeTable.
Note that this number does not include packets directed
to the broadcast address."
::= { hostTimeEntry 10 }
okay so hostTimeCreationOrder is the ordering index ๐ it gets numbered by insertion order, so older entries get lower numbers and newer ones get higher ones, from 1 up to N, where N is the associated hostControlTableSize โจ that means a manager can spot new entries without downloading the whole table, which is lowkey genius ๐ซถ
โ ๏ธ the catch: when an earlier entry gets deleted, the indexes can shift! so the manager should check hostControlLastDeleteTime to figure out if a download might've missed stuff or if an old index-to-entry match is no longer valid ๐
now the Host Top "N" Group ๐ธ this group is optional, and it needs the host group to be implemented first. the MODULE-COMPLIANCE macro is the real source of truth for conformance, so go check there ๐ basically, it makes reports ranking hosts by one of their stats, and those stats are rate-based samples taken over an interval the manager picks ๐
-- The Host Top "N" Group
-- Implementation of the Host Top N group is optional. The Host Top N
-- group requires the implementation of the host group.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The Host Top N group is used to prepare reports that describe
-- the hosts that top a list ordered by one of their statistics.
-- The available statistics are samples of one of their
-- base statistics, over an interval specified by the management
-- station. Thus, these statistics are rate based. The management
-- station also selects how many such hosts are reported.
-- The hostTopNControlTable is used to initiate the generation of
-- such a report. The management station may select the parameters
-- of such a report, such as which interface, which statistic,
-- how many hosts, and the start and stop times of the sampling.
-- When the report is prepared, entries are created in the
-- hostTopNTable associated with the relevant hostTopNControlEntry.
-- These entries are static for each report after it has been
-- prepared.
hostTopNControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF HostTopNControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of top N host control entries."
::= { hostTopN 1 }
hostTopNControlEntry OBJECT-TYPE
SYNTAX HostTopNControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of parameters that control the creation of a report
of the top N hosts according to several metrics. For
example, an instance of the hostTopNDuration object might
be named hostTopNDuration.3"
INDEX { hostTopNControlIndex }
::= { hostTopNControlTable 1 }
HostTopNControlEntry ::= SEQUENCE {
hostTopNControlIndex Integer32,
hostTopNHostIndex Integer32,
hostTopNRateBase INTEGER,
hostTopNTimeRemaining Integer32,
hostTopNDuration Integer32,
hostTopNRequestedSize Integer32,
hostTopNGrantedSize Integer32,
hostTopNStartTime TimeTicks,
hostTopNOwner OwnerString,
hostTopNStatus EntryStatus
}
hostTopNControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry
in the hostTopNControl table. Each such
entry defines one top N report prepared for
one interface."
::= { hostTopNControlEntry 1 }
hostTopNHostIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The host table for which a top N report will be prepared
on behalf of this entry. The host table identified by a
particular value of this index is associated with the same
host table as identified by the same value of
hostIndex.
This object may not be modified if the associated
hostTopNStatus object is equal to valid(1)."
::= { hostTopNControlEntry 2 }
hostTopNRateBase OBJECT-TYPE
SYNTAX INTEGER {
hostTopNInPkts(1),
hostTopNOutPkts(2),
hostTopNInOctets(3),
hostTopNOutOctets(4),
hostTopNOutErrors(5),
hostTopNOutBroadcastPkts(6),
hostTopNOutMulticastPkts(7)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The variable for each host that the hostTopNRate
variable is based upon.
This object may not be modified if the associated
hostTopNStatus object is equal to valid(1)."
::= { hostTopNControlEntry 3 }
hostTopNTimeRemaining OBJECT-TYPE
SYNTAX Integer32
UNITS "Seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of seconds left in the report currently being
collected. When this object is modified by the management
station, a new collection is started, possibly aborting
a currently running report. The new value is used
as the requested duration of this report, which is
loaded into the associated hostTopNDuration object.
When this object is set to a non-zero value, any
associated hostTopNEntries shall be made
inaccessible by the monitor. While the value of this
object is non-zero, it decrements by one per second until
it reaches zero. During this time, all associated
hostTopNEntries shall remain inaccessible. At the time
that this object decrements to zero, the report is made
accessible in the hostTopNTable. Thus, the hostTopN
table needs to be created only at the end of the collection
interval."
DEFVAL { 0 }
::= { hostTopNControlEntry 4 }
hostTopNDuration OBJECT-TYPE
SYNTAX Integer32
UNITS "Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that this report has collected
during the last sampling interval, or if this
report is currently being collected, the number
of seconds that this report is being collected
during this sampling interval.
When the associated hostTopNTimeRemaining object is set,
this object shall be set by the probe to the same value
and shall not be modified until the next time
the hostTopNTimeRemaining is set.
This value shall be zero if no reports have been
requested for this hostTopNControlEntry."
DEFVAL { 0 }
::= { hostTopNControlEntry 5 }
hostTopNRequestedSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of hosts requested for the top N
table.
When this object is created or modified, the probe
should set hostTopNGrantedSize as closely to this
object as is possible for the particular probe
implementation and available resources."
DEFVAL { 10 }
::= { hostTopNControlEntry 6 }
hostTopNGrantedSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of hosts in the top N table.
okay bestie, the hostTopN MIB is still going, and we're about to hit the Matrix group ๐ โจ
When the associated hostTopNRequestedSize object is
created or modified, the probe should set this
object as closely to the requested value as is possible
for the particular implementation and available
resources. The probe must not lower this value except
as a result of a set to the associated
hostTopNRequestedSize object.
Hosts with the highest value of hostTopNRate shall be
placed in this table in decreasing order of this rate
until there is no more room or until there are no more
hosts."
::= { hostTopNControlEntry 7 }
hostTopNStartTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this top N report was
last started. In other words, this is the time that
the associated hostTopNTimeRemaining object was
modified to start the requested report."
::= { hostTopNControlEntry 8 }
hostTopNOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is therefore
using the resources assigned to it."
::= { hostTopNControlEntry 9 }
hostTopNStatus OBJECT-TYPE
SYNTAX EntryStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this hostTopNControl entry.
If this object is not equal to valid(1), all associated
hostTopNEntries shall be deleted by the agent."
::= { hostTopNControlEntry 10 }
hostTopNTable OBJECT-TYPE
SYNTAX SEQUENCE OF HostTopNEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of top N host entries."
::= { hostTopN 2 }
hostTopNEntry OBJECT-TYPE
SYNTAX HostTopNEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of statistics for a host that is part of a top N
report. For example, an instance of the hostTopNRate
object might be named hostTopNRate.3.10"
INDEX { hostTopNReport, hostTopNIndex }
::= { hostTopNTable 1 }
HostTopNEntry ::= SEQUENCE {
hostTopNReport Integer32,
hostTopNIndex Integer32,
hostTopNAddress OCTET STRING,
hostTopNRate Integer32
}
hostTopNReport OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the top N report of which
this entry is a part. The set of hosts
identified by a particular value of this
object is part of the same report as identified
by the same value of the hostTopNControlIndex object."
::= { hostTopNEntry 1 }
hostTopNIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in
the hostTopN table among those in the same report.
This index is between 1 and N, where N is the
number of entries in this table. Increasing values
of hostTopNIndex shall be assigned to entries with
decreasing values of hostTopNRate until index N
is assigned to the entry with the lowest value of
hostTopNRate or there are no more hostTopNEntries."
::= { hostTopNEntry 2 }
hostTopNAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The physical address of this host."
::= { hostTopNEntry 3 }
hostTopNRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of change in the selected variable
during this sampling interval. The selected
variable is this host's instance of the object
selected by hostTopNRateBase."
::= { hostTopNEntry 4 }
-- The Matrix Group
-- Implementation of the Matrix group is optional.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The Matrix group consists of the matrixControlTable, matrixSDTable
-- and the matrixDSTable. These tables store statistics for a
-- particular conversation between two addresses. As the device
-- detects a new conversation, including those to a non-unicast
-- address, it creates a new entry in both of the matrix tables.
-- It must only create new entries based on information
-- received in good packets. If the monitoring device finds
-- itself short of resources, it may delete entries as needed.
-- It is suggested that the device delete the least recently used
-- entries first.
matrixControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF MatrixControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information entries for the
traffic matrix on each interface."
::= { matrix 1 }
matrixControlEntry OBJECT-TYPE
SYNTAX MatrixControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a traffic matrix on a particular
interface. For example, an instance of the
matrixControlLastDeleteTime object might be named
matrixControlLastDeleteTime.1"
INDEX { matrixControlIndex }
::= { matrixControlTable 1 }
MatrixControlEntry ::= SEQUENCE {
matrixControlIndex Integer32,
matrixControlDataSource OBJECT IDENTIFIER,
matrixControlTableSize Integer32,
matrixControlLastDeleteTime TimeTicks,
matrixControlOwner OwnerString,
matrixControlStatus EntryStatus
}
matrixControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
matrixControl table. Each such entry defines
a function that discovers conversations on a particular
interface and places statistics about them in the
matrixSDTable and the matrixDSTable on behalf of this
matrixControlEntry."
::= { matrixControlEntry 1 }
matrixControlDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the source of
the data from which this entry creates a traffic matrix.
This source can be any interface on this device. In
order to identify a particular interface, this object
shall identify the instance of the ifIndex object,
defined in RFC 2233 [17], for the desired
interface. For example, if an entry were to receive data
from interface #1, this object would be set to ifIndex.1.
The statistics in this group reflect all packets
on the local network segment attached to the identified
interface.
An agent may or may not be able to tell if fundamental
changes to the media of the interface have occurred and
necessitate an invalidation of this entry. For example, a
hot-pluggable ethernet card could be pulled out and replaced
by a token-ring card. In such a case, if the agent has such
knowledge of the change, it is recommended that it
invalidate this entry.
This object may not be modified if the associated
matrixControlStatus object is equal to valid(1)."
::= { matrixControlEntry 2 }
matrixControlTableSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of matrixSDEntries in the matrixSDTable
for this interface. This must also be the value of
the number of entries in the matrixDSTable for this
interface."
::= { matrixControlEntry 3 }
matrixControlLastDeleteTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the last entry
was deleted from the portion of the matrixSDTable
or matrixDSTable associated with this matrixControlEntry.
If no deletions have occurred, this value shall be
zero."
::= { matrixControlEntry 4 }
matrixControlOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is therefore
using the resources assigned to it."
::= { matrixControlEntry 5 }
matrixControlStatus OBJECT-TYPE
SYNTAX EntryStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this matrixControl entry.
If this object is not equal to valid(1), all associated
entries in the matrixSDTable and the matrixDSTable
shall be deleted by the agent."
::= { matrixControlEntry 6 }
matrixSDTable OBJECT-TYPE
SYNTAX SEQUENCE OF MatrixSDEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of traffic matrix entries indexed by
source and destination MAC address."
::= { matrix 2 }
matrixSDEntry OBJECT-TYPE
SYNTAX MatrixSDEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of statistics for communications between
two addresses on a particular interface. For example,
an instance of the matrixSDPkts object might be named
matrixSDPkts.1.6.8.0.32.27.3.176.6.8.0.32.10.8.113"
INDEX { matrixSDIndex,
matrixSDSourceAddress, matrixSDDestAddress }
::= { matrixSDTable 1 }
MatrixSDEntry ::= SEQUENCE {
matrixSDSourceAddress OCTET STRING,
matrixSDDestAddress OCTET STRING,
matrixSDIndex Integer32,
matrixSDPkts Counter32,
matrixSDOctets Counter32,
matrixSDErrors Counter32
}
matrixSDSourceAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The source physical address."
::= { matrixSDEntry 1 }
matrixSDDestAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The destination physical address."
::= { matrixSDEntry 2 }
matrixSDIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The set of collected matrix statistics of which
this entry is a part. The set of matrix statistics
identified by a particular value of this index
is associated with the same matrixControlEntry
as identified by the same value of matrixControlIndex."
::= { matrixSDEntry 3 }
matrixSDPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets transmitted from the source
address to the destination address (this number includes
bad packets)."
::= { matrixSDEntry 4 }
matrixSDOctets OBJECT-TYPE
SYNTAX Counter32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets (excluding framing bits but
including FCS octets) contained in all packets
transmitted from the source address to the
destination address."
::= { matrixSDEntry 5 }
the matrix tables are next, and they're giving detailed conversation tracking vibes ๐ฆ๐
Okay so the matrix tables are wrapping up here ๐ matrixSDErrors is the counter for bad packets going from source to destination, and then we switch lanes to the destination-to-source tables ๐ฆ
matrixSDErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bad packets transmitted from
the source address to the destination address."
::= { matrixSDEntry 6 }
-- Traffic matrix tables from destination to source
matrixDSTable OBJECT-TYPE
SYNTAX SEQUENCE OF MatrixDSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of traffic matrix entries indexed by
destination and source MAC address."
::= { matrix 3 }
matrixDSEntry OBJECT-TYPE
SYNTAX MatrixDSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of statistics for communications between
two addresses on a particular interface. For example,
an instance of the matrixSDPkts object might be named
matrixSDPkts.1.6.8.0.32.10.8.113.6.8.0.32.27.3.176"
INDEX { matrixDSIndex,
matrixDSDestAddress, matrixDSSourceAddress }
::= { matrixDSTable 1 }
MatrixDSEntry ::= SEQUENCE {
matrixDSSourceAddress OCTET STRING,
matrixDSDestAddress OCTET STRING,
matrixDSIndex Integer32,
matrixDSPkts Counter32,
matrixDSOctets Counter32,
matrixDSErrors Counter32
}
matrixDSSourceAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The source physical address."
::= { matrixDSEntry 1 }
matrixDSDestAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The destination physical address."
::= { matrixDSEntry 2 }
matrixDSIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The set of collected matrix statistics of which
this entry is a part. The set of matrix statistics
identified by a particular value of this index
is associated with the same matrixControlEntry
as identified by the same value of matrixControlIndex."
::= { matrixDSEntry 3 }
matrixDSPkts OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets transmitted from the source
address to the destination address (this number includes
bad packets)."
::= { matrixDSEntry 4 }
matrixDSOctets OBJECT-TYPE
SYNTAX Counter32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets (excluding framing bits
but including FCS octets) contained in all packets
transmitted from the source address to the
destination address."
::= { matrixDSEntry 5 }
matrixDSErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bad packets transmitted from
the source address to the destination address."
::= { matrixDSEntry 6 }
-- The Filter Group
-- Implementation of the Filter group is optional.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The Filter group allows packets to be captured with an
-- arbitrary filter expression. A logical data and
-- event stream or "channel" is formed by the packets
-- that match the filter expression.
--
-- This filter mechanism allows the creation of an arbitrary
-- logical expression with which to filter packets. Each
-- filter associated with a channel is OR'ed with the others.
-- Within a filter, any bits checked in the data and status are
-- AND'ed with respect to other bits in the same filter. The
-- NotMask also allows for checking for inequality. Finally,
-- the channelAcceptType object allows for inversion of the
-- whole equation.
--
-- If a management station wishes to receive a trap to alert it
-- that new packets have been captured and are available for
-- download, it is recommended that it set up an alarm entry that
-- monitors the value of the relevant channelMatches instance.
--
-- The channel can be turned on or off, and can also
-- generate events when packets pass through it.
filterTable OBJECT-TYPE
SYNTAX SEQUENCE OF FilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of packet filter entries."
::= { filter 1 }
filterEntry OBJECT-TYPE
SYNTAX FilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of parameters for a packet filter applied on a
particular interface. As an example, an instance of the
filterPktData object might be named filterPktData.12"
INDEX { filterIndex }
::= { filterTable 1 }
FilterEntry ::= SEQUENCE {
filterIndex Integer32,
filterChannelIndex Integer32,
filterPktDataOffset Integer32,
filterPktData OCTET STRING,
filterPktDataMask OCTET STRING,
filterPktDataNotMask OCTET STRING,
filterPktStatus Integer32,
filterPktStatusMask Integer32,
filterPktStatusNotMask Integer32,
filterOwner OwnerString,
filterStatus EntryStatus
}
filterIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry
in the filter table. Each such entry defines
one filter that is to be applied to every packet
received on an interface."
::= { filterEntry 1 }
filterChannelIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the channel of which this filter
is a part. The filters identified by a particular value
of this object are associated with the same channel as
identified by the same value of the channelIndex object."
::= { filterEntry 2 }
filterPktDataOffset OBJECT-TYPE
SYNTAX Integer32
UNITS "Octets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The offset from the beginning of each packet where
a match of packet data will be attempted. This offset
is measured from the point in the physical layer
packet after the framing bits, if any. For example,
in an Ethernet frame, this point is at the beginning of
the destination MAC address.
This object may not be modified if the associated
filterStatus object is equal to valid(1)."
DEFVAL { 0 }
::= { filterEntry 3 }
filterPktData OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The data that is to be matched with the input packet.
For each packet received, this filter and the accompanying
filterPktDataMask and filterPktDataNotMask will be
adjusted for the offset. The only bits relevant to this
match algorithm are those that have the corresponding
filterPktDataMask bit equal to one. The following three
rules are then applied to every packet:
(1) If the packet is too short and does not have data
corresponding to part of the filterPktData, the packet
will fail this data match.
(2) For each relevant bit from the packet with the
corresponding filterPktDataNotMask bit set to zero, if
the bit from the packet is not equal to the corresponding
bit from the filterPktData, then the packet will fail
this data match.
(3) If for every relevant bit from the packet with the
corresponding filterPktDataNotMask bit set to one, the
bit from the packet is equal to the corresponding bit
from the filterPktData, then the packet will fail this
data match.
Any packets that have not failed any of the three matches
above have passed this data match. In particular, a zero
length filter will match any packet.
This object may not be modified if the associated
filterStatus object is equal to valid(1)."
::= { filterEntry 4 }
filterPktDataMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The mask that is applied to the match process.
After adjusting this mask for the offset, only those
bits in the received packet that correspond to bits set
in this mask are relevant for further processing by the
match algorithm. The offset is applied to filterPktDataMask
in the same way it is applied to the filter. For the
purposes of the matching algorithm, if the associated
filterPktData object is longer than this mask, this mask is
conceptually extended with '1' bits until it reaches the
length of the filterPktData object.
This object may not be modified if the associated
filterStatus object is equal to valid(1)."
::= { filterEntry 5 }
filterPktDataNotMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The inversion mask that is applied to the match
process. After adjusting this mask for the offset,
those relevant bits in the received packet that correspond
to bits cleared in this mask must all be equal to their
corresponding bits in the filterPktData object for the packet
to be accepted. In addition, at least one of those relevant
bits in the received packet that correspond to bits set in
this mask must be different to its corresponding bit in the
filterPktData object.
For the purposes of the matching algorithm, if the associated
filterPktData object is longer than this mask, this mask is
conceptually extended with '0' bits until it reaches the
length of the filterPktData object.
This object may not be modified if the associated
filterStatus object is equal to valid(1)."
::= { filterEntry 6 }
filterPktStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status that is to be matched with the input packet.
The only bits relevant to this match algorithm are those that
have the corresponding filterPktStatusMask bit equal to one.
The following two rules are then applied to every packet:
(1) For each relevant bit from the packet status with the
corresponding filterPktStatusNotMask bit set to zero, if
the bit from the packet status is not equal to the
corresponding bit from the filterPktStatus, then the
packet will fail this status match.
(2) If for every relevant bit from the packet status with the
corresponding filterPktStatusNotMask bit set to one, the
bit from the packet status is equal to the corresponding
bit from the filterPktStatus, then the packet will fail
this status match.
Any packets that have not failed either of the two matches
above have passed this status match. In particular, a zero
length status filter will match any packet's status.
Okay so the packet status is literally a sum, bestie ๐งฎโจ It starts at zero, and then for every error E found in the packet, you add 2 raised to the number that represents E. The bits depend on the media type of the interface the channel is receiving from, so it's not one-size-fits-all ๐
The value of the packet status is a sum. This sum
initially takes the value zero. Then, for each
error, E, that has been discovered in this packet,
2 raised to a value representing E is added to the sum.
The errors and the bits that represent them are dependent
on the media type of the interface that this channel
is receiving packets from.
The errors defined for a packet captured off of an
Ethernet interface are as follows:
bit # Error
0 Packet is longer than 1518 octets
1 Packet is shorter than 64 octets
2 Packet experienced a CRC or Alignment error
For example, an Ethernet fragment would have a
value of 6 (2^1 + 2^2).
As this MIB is expanded to new media types, this object
will have other media-specific errors defined.
For the purposes of this status matching algorithm, if the
packet status is longer than this filterPktStatus object,
this object is conceptually extended with '0' bits until it
reaches the size of the packet status.
This object may not be modified if the associated
filterStatus object is equal to valid(1)."
::= { filterEntry 7 }
So an Ethernet fragment is bits 1 and 2 together, which is 2 + 4 = 6 ๐ฆ Also, the status can grow with new media types later, so keep an eye on this one ๐
filterPktStatusMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The mask that is applied to the status match process.
Only those bits in the received packet that correspond to
bits set in this mask are relevant for further processing
by the status match algorithm. For the purposes
of the matching algorithm, if the associated filterPktStatus
object is longer than this mask, this mask is conceptually
extended with '1' bits until it reaches the size of the
filterPktStatus. In addition, if a packet status is longer
than this mask, this mask is conceptually extended with '0'
bits until it reaches the size of the packet status.
This object may not be modified if the associated
filterStatus object is equal to valid(1)."
::= { filterEntry 8 }
The mask is the filter for the status check itself ๐ญ Only the bits that are set in the mask get looked at, and the mask gets padded out with '1' bits or '0' bits depending on how long things are. The padding rules are a whole vibe, so read them carefully ๐ธ
filterPktStatusNotMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The inversion mask that is applied to the status match
process. Those relevant bits in the received packet status
that correspond to bits cleared in this mask must all be
equal to their corresponding bits in the filterPktStatus
object for the packet to be accepted. In addition, at least
one of those relevant bits in the received packet status
that correspond to bits set in this mask must be different
to its corresponding bit in the filterPktStatus object for
the packet to be accepted.
For the purposes of the matching algorithm, if the associated
filterPktStatus object or a packet status is longer than this
mask, this mask is conceptually extended with '0' bits until
it reaches the longer of the lengths of the filterPktStatus
object and the packet status.
This object may not be modified if the associated
filterStatus object is equal to valid(1)."
::= { filterEntry 9 }
This one is the inversion mask, and it's kind of a plot twist ๐ For bits cleared in the mask, the packet's relevant bits have to match filterPktStatus exactly. For bits set in the mask, at least one of them has to be different. The padding goes to whichever length is longer, so it's extra careful ๐ง
filterOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is therefore
using the resources assigned to it."
::= { filterEntry 10 }
filterStatus OBJECT-TYPE
SYNTAX EntryStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this filter entry."
::= { filterEntry 11 }
filterOwner is basically "whoever made this entry and is using its resources" ๐โโ๏ธ and filterStatus is the entry's status, plain and simple ๐
channelTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of packet channel entries."
::= { filter 2 }
channelEntry OBJECT-TYPE
SYNTAX ChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of parameters for a packet channel applied on a
particular interface. As an example, an instance of the
channelMatches object might be named channelMatches.3"
INDEX { channelIndex }
::= { channelTable 1 }
ChannelEntry ::= SEQUENCE {
channelIndex Integer32,
channelIfIndex Integer32,
channelAcceptType INTEGER,
channelDataControl INTEGER,
channelTurnOnEventIndex Integer32,
channelTurnOffEventIndex Integer32,
channelEventIndex Integer32,
channelEventStatus INTEGER,
channelMatches Counter32,
channelDescription DisplayString,
channelOwner OwnerString,
channelStatus EntryStatus
}
Now we're on channels ๐ก The channelTable is just a list of packet channel entries, and each entry is a set of parameters for one channel on one interface. The table is indexed by channelIndex, and the ChannelEntry sequence lists everything that lives in a channel row โจ
channelIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the channel
table. Each such entry defines one channel, a logical
data and event stream.
It is suggested that before creating a channel, an
application should scan all instances of the
filterChannelIndex object to make sure that there are no
pre-existing filters that would be inadvertently be linked
to the channel."
::= { channelEntry 1 }
channelIndex is the unique ID for each channel, and the suggestion here is pretty sensible ๐ง Before you make a new channel, scan the filterChannelIndex objects so you don't accidentally link an old filter to it ๐
channelIfIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object uniquely identifies the
interface on this remote network monitoring device to which
the associated filters are applied to allow data into this
channel. The interface identified by a particular value
of this object is the same interface as identified by the
same value of the ifIndex object, defined in RFC 2233 [17].
The filters in this group are applied to all packets on
the local network segment attached to the identified
interface.
An agent may or may not be able to tell if fundamental
changes to the media of the interface have occurred and
necessitate an invalidation of this entry. For example, a
hot-pluggable ethernet card could be pulled out and replaced
by a token-ring card. In such a case, if the agent has such
knowledge of the change, it is recommended that it
invalidate this entry.
This object may not be modified if the associated
channelStatus object is equal to valid(1)."
::= { channelEntry 2 }
channelIfIndex picks which interface the channel listens on, and it lines up with the ifIndex from RFC 2233 [17] ๐ The filters apply to everything on that interface's local segment. There's also the hot-swap example, where an Ethernet card gets yanked and swapped for a token-ring card, and the agent is recommended to invalidate the entry if it knows that happened. Very dramatic, very real ๐ญ
channelAcceptType OBJECT-TYPE
SYNTAX INTEGER {
acceptMatched(1),
acceptFailed(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls the action of the filters
associated with this channel. If this object is equal
to acceptMatched(1), packets will be accepted to this
channel if they are accepted by both the packet data and
packet status matches of an associated filter. If
this object is equal to acceptFailed(2), packets will
be accepted to this channel only if they fail either
the packet data match or the packet status match of
each of the associated filters.
In particular, a channel with no associated filters will
match no packets if set to acceptMatched(1) case and will
match all packets in the acceptFailed(2) case.
This object may not be modified if the associated
channelStatus object is equal to valid(1)."
::= { channelEntry 3 }
channelAcceptType is where the drama really is ๐ญ With acceptMatched(1), a packet only gets in if it passes both the data match and the status match. With acceptFailed(2), a packet gets in only if it fails either one. And a channel with no filters at all? It catches nothing in acceptMatched(1) mode and literally everything in acceptFailed(2) mode ๐ Iconic, honestly.
channelDataControl OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls the flow of data through this channel.
If this object is on(1), data, status and events flow
through this channel. If this object is off(2), data,
status and events will not flow through this channel."
DEFVAL { off }
::= { channelEntry 4 }
channelDataControl is the on/off switch for the whole channel ๐ฆ When it's on(1), data, status and events flow. When it's off(2), none of them do. The default is off, so nothing flows until you turn it on ๐
channelTurnOnEventIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the event
that is configured to turn the associated
channelDataControl from off to on when the event is
generated. The event identified by a particular value
of this object is the same event as identified by the
same value of the eventIndex object. If there is no
corresponding entry in the eventTable, then no
association exists. In fact, if no event is intended
for this channel, channelTurnOnEventIndex must be
set to zero, a non-existent event index.
This object may not be modified if the associated
channelStatus object is equal to valid(1)."
::= { channelEntry 5 }
channelTurnOffEventIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the event
that is configured to turn the associated
channelDataControl from on to off when the event is
generated. The event identified by a particular value
of this object is the same event as identified by the
same value of the eventIndex object. If there is no
corresponding entry in the eventTable, then no
association exists. In fact, if no event is intended
for this channel, channelTurnOffEventIndex must be
set to zero, a non-existent event index.
This object may not be modified if the associated
channelStatus object is equal to valid(1)."
::= { channelEntry 6 }
These two are the event triggers for the channel's on/off switch โก channelTurnOnEventIndex flips it from off to on when its event fires, and channelTurnOffEventIndex flips it from on to off. They both point into the eventTable through eventIndex. If you don't want an event involved, set it to zero, which is basically the "no event here" number ๐ซถ
channelEventIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the event
that is configured to be generated when the
associated channelDataControl is on and a packet
is matched. The event identified by a particular value
of this object is the same event as identified by the
same value of the eventIndex object. If there is no
corresponding entry in the eventTable, then no
association exists. In fact, if no event is intended
for this channel, channelEventIndex must be
set to zero, a non-existent event index.
This object may not be modified if the associated
channelStatus object is equal to valid(1)."
::= { channelEntry 7 }
channelEventIndex is the event that gets generated when the channel is on and a packet matches ๐ Same deal as before: no event wanted means zero, and it won't change while the channel is valid ๐
channelEventStatus OBJECT-TYPE
SYNTAX INTEGER {
eventReady(1),
eventFired(2),
eventAlwaysReady(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The event status of this channel.
If this channel is configured to generate events
when packets are matched, a means of controlling
the flow of those events is often needed. When
this object is equal to eventReady(1), a single
event may be generated, after which this object
will be set by the probe to eventFired(2). While
in the eventFired(2) state, no events will be
generated until the object is modified to
eventReady(1) (or eventAlwaysReady(3)). The
management station can thus easily respond to a
notification of an event by re-enabling this object.
Last one for this chunk, and it's giving flow control ๐ If the channel makes events, you usually want a way to pace them. In eventReady(1), one event can fire, and then the probe flips it to eventFired(2) and holds off until someone sets it back to eventReady(1) or eventAlwaysReady(3). So the management station can see the notification and just re-enable it ๐
okay so the channel table is literally wrapping up ๐ here's the rest of the channel entry, no cap ๐
If the management station wishes to disable this
flow control and allow events to be generated
at will, this object may be set to
eventAlwaysReady(3). Disabling the flow control
is discouraged as it can result in high network
traffic or other performance problems."
DEFVAL { eventReady }
::= { channelEntry 8 }
channelMatches OBJECT-TYPE
SYNTAX Counter32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times this channel has matched a packet.
Note that this object is updated even when
channelDataControl is set to off."
::= { channelEntry 9 }
channelDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A comment describing this channel."
::= { channelEntry 10 }
channelOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is therefore
using the resources assigned to it."
::= { channelEntry 11 }
channelStatus OBJECT-TYPE
SYNTAX EntryStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this channel entry."
::= { channelEntry 12 }
ooh bestie, now we're entering the Packet Capture Group ๐ฆ it's optional to implement, but it requires the Filter Group first, so make sure that's already sorted ๐ซถ the vibe is that filters pick the packets and this group stores them in capture buffers. iconic, honestly โจ
-- The Packet Capture Group
-- Implementation of the Packet Capture group is optional. The Packet
-- Capture Group requires implementation of the Filter Group.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The Packet Capture group allows packets to be captured
-- upon a filter match. The bufferControlTable controls
-- the captured packets output from a channel that is
-- associated with it. The captured packets are placed
-- in entries in the captureBufferTable. These entries are
-- associated with the bufferControlEntry on whose behalf they
-- were stored.
bufferControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF BufferControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of buffers control entries."
::= { capture 1 }
bufferControlEntry OBJECT-TYPE
SYNTAX BufferControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of parameters that control the collection of a stream
of packets that have matched filters. As an example, an
instance of the bufferControlCaptureSliceSize object might
be named bufferControlCaptureSliceSize.3"
INDEX { bufferControlIndex }
::= { bufferControlTable 1 }
BufferControlEntry ::= SEQUENCE {
bufferControlIndex Integer32,
bufferControlChannelIndex Integer32,
bufferControlFullStatus INTEGER,
bufferControlFullAction INTEGER,
bufferControlCaptureSliceSize Integer32,
bufferControlDownloadSliceSize Integer32,
bufferControlDownloadOffset Integer32,
bufferControlMaxOctetsRequested Integer32,
bufferControlMaxOctetsGranted Integer32,
bufferControlCapturedPackets Integer32,
bufferControlTurnOnTime TimeTicks,
bufferControlOwner OwnerString,
bufferControlStatus EntryStatus
}
bufferControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry
in the bufferControl table. The value of this
index shall never be zero. Each such
entry defines one set of packets that is
captured and controlled by one or more filters."
::= { bufferControlEntry 1 }
bufferControlChannelIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An index that identifies the channel that is the
source of packets for this bufferControl table.
The channel identified by a particular value of this
index is the same as identified by the same value of
the channelIndex object.
This object may not be modified if the associated
bufferControlStatus object is equal to valid(1)."
::= { bufferControlEntry 2 }
bufferControlFullStatus OBJECT-TYPE
SYNTAX INTEGER {
spaceAvailable(1),
full(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows whether the buffer has room to
accept new packets or if it is full.
If the status is spaceAvailable(1), the buffer is
accepting new packets normally. If the status is
full(2) and the associated bufferControlFullAction
object is wrapWhenFull, the buffer is accepting new
packets by deleting enough of the oldest packets
to make room for new ones as they arrive. Otherwise,
if the status is full(2) and the
bufferControlFullAction object is lockWhenFull,
then the buffer has stopped collecting packets.
When this object is set to full(2) the probe must
not later set it to spaceAvailable(1) except in the
case of a significant gain in resources such as
an increase of bufferControlOctetsGranted. In
particular, the wrap-mode action of deleting old
packets to make room for newly arrived packets
must not affect the value of this object."
::= { bufferControlEntry 3 }
bufferControlFullAction OBJECT-TYPE
SYNTAX INTEGER {
lockWhenFull(1),
wrapWhenFull(2) -- FIFO
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls the action of the buffer when it
reaches the full status. When in the lockWhenFull(1)
state and a packet is added to the buffer that
fills the buffer, the bufferControlFullStatus will
be set to full(2) and this buffer will stop capturing
packets."
::= { bufferControlEntry 4 }
the capture slice settings are next and they're giving main character energy ๐
bufferControlCaptureSliceSize OBJECT-TYPE
SYNTAX Integer32
UNITS "Octets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of octets of each packet
that will be saved in this capture buffer.
For example, if a 1500 octet packet is received by
the probe and this object is set to 500, then only
500 octets of the packet will be stored in the
associated capture buffer. If this variable is set
to 0, the capture buffer will save as many octets
as is possible.
This object may not be modified if the associated
bufferControlStatus object is equal to valid(1)."
DEFVAL { 100 }
::= { bufferControlEntry 5 }
bufferControlDownloadSliceSize OBJECT-TYPE
SYNTAX Integer32
UNITS "Octets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of octets of each packet
in this capture buffer that will be returned in
an SNMP retrieval of that packet. For example,
if 500 octets of a packet have been stored in the
associated capture buffer, the associated
bufferControlDownloadOffset is 0, and this
object is set to 100, then the captureBufferPacket
object that contains the packet will contain only
the first 100 octets of the packet.
A prudent manager will take into account possible
interoperability or fragmentation problems that may
occur if the download slice size is set too large.
In particular, conformant SNMP implementations are not
required to accept messages whose length exceeds 484
octets, although they are encouraged to support larger
datagrams whenever feasible."
DEFVAL { 100 }
::= { bufferControlEntry 6 }
bufferControlDownloadOffset OBJECT-TYPE
SYNTAX Integer32
UNITS "Octets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The offset of the first octet of each packet
in this capture buffer that will be returned in
an SNMP retrieval of that packet. For example,
if 500 octets of a packet have been stored in the
associated capture buffer and this object is set to
100, then the captureBufferPacket object that
contains the packet will contain bytes starting
100 octets into the packet."
DEFVAL { 0 }
::= { bufferControlEntry 7 }
bufferControlMaxOctetsRequested OBJECT-TYPE
SYNTAX Integer32
UNITS "Octets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The requested maximum number of octets to be
saved in this captureBuffer, including any
implementation-specific overhead. If this variable
is set to -1, the capture buffer will save as many
octets as is possible.
When this object is created or modified, the probe
should set bufferControlMaxOctetsGranted as closely
to this object as is possible for the particular probe
implementation and available resources. However, if
the object has the special value of -1, the probe
must set bufferControlMaxOctetsGranted to -1."
DEFVAL { -1 }
::= { bufferControlEntry 8 }
bufferControlMaxOctetsGranted OBJECT-TYPE
SYNTAX Integer32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of octets that can be
saved in this captureBuffer, including overhead.
If this variable is -1, the capture buffer will save
as many octets as possible.
When the bufferControlMaxOctetsRequested object is
created or modified, the probe should set this object
as closely to the requested value as is possible for the
particular probe implementation and available resources.
However, if the request object has the special value
of -1, the probe must set this object to -1.
The probe must not lower this value except as a result of
a modification to the associated
bufferControlMaxOctetsRequested object.
When this maximum number of octets is reached
and a new packet is to be added to this
capture buffer and the corresponding
bufferControlFullAction is set to wrapWhenFull(2),
enough of the oldest packets associated with this
capture buffer shall be deleted by the agent so
that the new packet can be added. If the corresponding
bufferControlFullAction is set to lockWhenFull(1),
the new packet shall be discarded. In either case,
the probe must set bufferControlFullStatus to
full(2).
When the value of this object changes to a value less
than the current value, entries are deleted from
the captureBufferTable associated with this
bufferControlEntry. Enough of the
oldest of these captureBufferEntries shall be
deleted by the agent so that the number of octets
used remains less than or equal to the new value of
this object.
When the value of this object changes to a value greater
than the current value, the number of associated
captureBufferEntries may be allowed to grow."
::= { bufferControlEntry 9 }
Okay bestie, the buffer stuff is where the packets actually live ๐ฆโจ Here's how the captured-packet counter, timestamps, and error flags work, plus the Event Group's logging setup ๐
bufferControlCapturedPackets OBJECT-TYPE
SYNTAX Integer32
UNITS "Packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets currently in this captureBuffer."
::= { bufferControlEntry 10 }
bufferControlTurnOnTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this capture buffer was
first turned on."
::= { bufferControlEntry 11 }
bufferControlOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is therefore
using the resources assigned to it."
::= { bufferControlEntry 12 }
bufferControlStatus OBJECT-TYPE
SYNTAX EntryStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this buffer Control Entry."
::= { bufferControlEntry 13 }
captureBufferTable OBJECT-TYPE
SYNTAX SEQUENCE OF CaptureBufferEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of packets captured off of a channel."
::= { capture 2 }
captureBufferEntry OBJECT-TYPE
SYNTAX CaptureBufferEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A packet captured off of an attached network. As an
example, an instance of the captureBufferPacketData
object might be named captureBufferPacketData.3.1783"
INDEX { captureBufferControlIndex, captureBufferIndex }
::= { captureBufferTable 1 }
CaptureBufferEntry ::= SEQUENCE {
captureBufferControlIndex Integer32,
captureBufferIndex Integer32,
captureBufferPacketID Integer32,
captureBufferPacketData OCTET STRING,
captureBufferPacketLength Integer32,
captureBufferPacketTime Integer32,
captureBufferPacketStatus Integer32
}
captureBufferControlIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the bufferControlEntry with which
this packet is associated."
::= { captureBufferEntry 1 }
captureBufferIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry
in the captureBuffer table associated with a
particular bufferControlEntry. This index will
start at 1 and increase by one for each new packet
added with the same captureBufferControlIndex.
Should this value reach 2147483647, the next packet
added with the same captureBufferControlIndex shall
cause this value to wrap around to 1."
::= { captureBufferEntry 2 }
captureBufferPacketID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that describes the order of packets
that are received on a particular interface.
The packetID of a packet captured on an
interface is defined to be greater than the
packetID's of all packets captured previously on
the same interface. As the captureBufferPacketID
object has a maximum positive value of 2^31 - 1,
any captureBufferPacketID object shall have the
value of the associated packet's packetID mod 2^31."
::= { captureBufferEntry 3 }
captureBufferPacketData OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The data inside the packet, starting at the beginning
of the packet plus any offset specified in the
associated bufferControlDownloadOffset, including any
link level headers. The length of the data in this object
is the minimum of the length of the captured packet minus
the offset, the length of the associated
bufferControlCaptureSliceSize minus the offset, and the
associated bufferControlDownloadSliceSize. If this minimum
is less than zero, this object shall have a length of zero."
::= { captureBufferEntry 4 }
captureBufferPacketLength OBJECT-TYPE
SYNTAX Integer32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual length (off the wire) of the packet stored
in this entry, including FCS octets."
::= { captureBufferEntry 5 }
captureBufferPacketTime OBJECT-TYPE
SYNTAX Integer32
UNITS "Milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of milliseconds that had passed since
this capture buffer was first turned on when this
packet was captured."
::= { captureBufferEntry 6 }
captureBufferPacketStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A value which indicates the error status of this packet.
The value of this object is defined in the same way as
filterPktStatus. The value is a sum. This sum
initially takes the value zero. Then, for each
error, E, that has been discovered in this packet,
2 raised to a value representing E is added to the sum.
The errors defined for a packet captured off of an
Ethernet interface are as follows:
bit # Error
0 Packet is longer than 1518 octets
1 Packet is shorter than 64 octets
2 Packet experienced a CRC or Alignment error
3 First packet in this capture buffer after
it was detected that some packets were
not processed correctly.
4 Packet's order in buffer is only approximate
(May only be set for packets sent from
the probe)
For example, an Ethernet fragment would have a
value of 6 (2^1 + 2^2).
As this MIB is expanded to new media types, this object
will have other media-specific errors defined."
::= { captureBufferEntry 7 }
Next up is the Event Group, which is where the alarms get their hype ๐๐ Here's the setup: it's optional to implement, and the MODULE-COMPLIANCE macro is the source of truth for conformance ๐ซถ
-- The Event Group
-- Implementation of the Event group is optional.
-- Consult the MODULE-COMPLIANCE macro for the authoritative
-- conformance information for this MIB.
--
-- The Event group controls the generation and notification
-- of events from this device. Each entry in the eventTable
-- describes the parameters of the event that can be triggered.
-- Each event entry is fired by an associated condition located
-- elsewhere in the MIB. An event entry may also be associated
-- with a function elsewhere in the MIB that will be executed
-- when the event is generated. For example, a channel may
-- be turned on or off by the firing of an event.
--
-- Each eventEntry may optionally specify that a log entry
-- be created on its behalf whenever the event occurs.
-- Each entry may also specify that notification should
-- occur by way of SNMP trap messages. In this case, the
-- community for the trap message is given in the associated
-- eventCommunity object. The enterprise and specific trap
-- fields of the trap are determined by the condition that
-- triggered the event. Two traps are defined: risingAlarm and
-- fallingAlarm. If the eventTable is triggered by a condition
-- specified elsewhere, the enterprise and specific trap fields
-- must be specified for traps generated for that condition.
eventTable OBJECT-TYPE
SYNTAX SEQUENCE OF EventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of events to be generated."
::= { event 1 }
eventEntry OBJECT-TYPE
SYNTAX EventEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of parameters that describe an event to be generated
when certain conditions are met. As an example, an instance
of the eventLastTimeSent object might be named
eventLastTimeSent.6"
INDEX { eventIndex }
::= { eventTable 1 }
EventEntry ::= SEQUENCE {
eventIndex Integer32,
eventDescription DisplayString,
eventType INTEGER,
eventCommunity OCTET STRING,
eventLastTimeSent TimeTicks,
eventOwner OwnerString,
eventStatus EntryStatus
}
eventIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry in the
event table. Each such entry defines one event that
is to be generated when the appropriate conditions
occur."
::= { eventEntry 1 }
eventDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A comment describing this event entry."
::= { eventEntry 2 }
eventType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
log(2),
snmptrap(3), -- send an SNMP trap
logandtrap(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of notification that the probe will make
about this event. In the case of log, an entry is
made in the log table for each event. In the case of
snmp-trap, an SNMP trap is sent to one or more
management stations."
::= { eventEntry 3 }
eventCommunity OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..127))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"If an SNMP trap is to be sent, it will be sent to
the SNMP community specified by this octet string."
::= { eventEntry 4 }
eventLastTimeSent OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time this event
entry last generated an event. If this entry has
not generated any events, this value will be
zero."
::= { eventEntry 5 }
eventOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry and is therefore
using the resources assigned to it.
If this object contains a string starting with 'monitor'
and has associated entries in the log table, all connected
management stations should retrieve those log entries,
as they may have significance to all management stations
connected to this device"
::= { eventEntry 6 }
eventStatus OBJECT-TYPE
SYNTAX EntryStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this event entry.
If this object is not equal to valid(1), all associated
log entries shall be deleted by the agent."
::= { eventEntry 7 }
--
logTable OBJECT-TYPE
SYNTAX SEQUENCE OF LogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of events that have been logged."
::= { event 2 }
logEntry OBJECT-TYPE
SYNTAX LogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of data describing an event that has been
logged. For example, an instance of the logDescription
object might be named logDescription.6.47"
INDEX { logEventIndex, logIndex }
::= { logTable 1 }
okay bestie, the log table is up next ๐ Each logEntry is one row, and it's got four columns.
LogEntry ::= SEQUENCE {
logEventIndex Integer32,
logIndex Integer32,
logTime TimeTicks,
logDescription DisplayString
}
logEventIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The event entry that generated this log
entry. The log identified by a particular
value of this index is associated with the same
eventEntry as identified by the same value
of eventIndex."
::= { logEntry 1 }
logIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies an entry
in the log table amongst those generated by the
same eventEntries. These indexes are
assigned beginning with 1 and increase by one
with each new log entry. The association
between values of logIndex and logEntries
is fixed for the lifetime of each logEntry.
The agent may choose to delete the oldest
instances of logEntry as required because of
lack of memory. It is an implementation-specific
matter as to when this deletion may occur."
::= { logEntry 2 }
logTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this log entry was created."
::= { logEntry 3 }
logDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An implementation dependent description of the
event that activated this log entry."
::= { logEntry 4 }
Now the traps! ๐ These are the SNMP notifications that get sent out when an alarm crosses its thresholds. Both only fire for alarm entries whose event is set up to send traps. ๐ฆ
-- Remote Network Monitoring Traps
rmonEventsV2 OBJECT-IDENTITY
STATUS current
DESCRIPTION "Definition point for RMON notifications."
::= { rmon 0 }
risingAlarm NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmVariable, alarmSampleType,
alarmValue, alarmRisingThreshold }
STATUS current
DESCRIPTION
"The SNMP trap that is generated when an alarm
entry crosses its rising threshold and generates
an event that is configured for sending SNMP
traps."
::= { rmonEventsV2 1 }
fallingAlarm NOTIFICATION-TYPE
OBJECTS { alarmIndex, alarmVariable, alarmSampleType,
alarmValue, alarmFallingThreshold }
STATUS current
DESCRIPTION
"The SNMP trap that is generated when an alarm
entry crosses its falling threshold and generates
an event that is configured for sending SNMP
traps."
::= { rmonEventsV2 2 }
Next up is conformance โจ This is the part that spells out which groups an implementation has to have. Here we go ๐
-- Conformance information
rmonCompliances OBJECT IDENTIFIER ::= { rmonConformance 9 }
rmonGroups OBJECT IDENTIFIER ::= { rmonConformance 10 }
-- Compliance Statements
rmonCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The requirements for conformance to the RMON MIB. At least
one of the groups in this module must be implemented to
conform to the RMON MIB. Implementations of this MIB
must also implement the system group of MIB-II [16] and the
IF-MIB [17]."
MODULE -- this module
GROUP rmonEtherStatsGroup
DESCRIPTION
"The RMON Ethernet Statistics Group is optional."
GROUP rmonHistoryControlGroup
DESCRIPTION
"The RMON History Control Group is optional."
GROUP rmonEthernetHistoryGroup
DESCRIPTION
"The RMON Ethernet History Group is optional."
GROUP rmonAlarmGroup
DESCRIPTION
"The RMON Alarm Group is optional."
GROUP rmonHostGroup
DESCRIPTION
"The RMON Host Group is mandatory when the
rmonHostTopNGroup is implemented."
GROUP rmonHostTopNGroup
DESCRIPTION
"The RMON Host Top N Group is optional."
GROUP rmonMatrixGroup
DESCRIPTION
"The RMON Matrix Group is optional."
GROUP rmonFilterGroup
DESCRIPTION
"The RMON Filter Group is mandatory when the
rmonPacketCaptureGroup is implemented."
GROUP rmonPacketCaptureGroup
DESCRIPTION
"The RMON Packet Capture Group is optional."
GROUP rmonEventGroup
DESCRIPTION
"The RMON Event Group is mandatory when the
rmonAlarmGroup is implemented."
::= { rmonCompliances 1 }
Now the group definitions ๐ง Each one is just a bundle of objects that get listed together.
rmonEtherStatsGroup OBJECT-GROUP
OBJECTS {
etherStatsIndex, etherStatsDataSource,
etherStatsDropEvents, etherStatsOctets, etherStatsPkts,
etherStatsBroadcastPkts, etherStatsMulticastPkts,
etherStatsCRCAlignErrors, etherStatsUndersizePkts,
etherStatsOversizePkts, etherStatsFragments,
etherStatsJabbers, etherStatsCollisions,
etherStatsPkts64Octets, etherStatsPkts65to127Octets,
etherStatsPkts128to255Octets,
etherStatsPkts256to511Octets,
etherStatsPkts512to1023Octets,
etherStatsPkts1024to1518Octets,
etherStatsOwner, etherStatsStatus
}
STATUS current
DESCRIPTION
"The RMON Ethernet Statistics Group."
::= { rmonGroups 1 }
rmonHistoryControlGroup OBJECT-GROUP
OBJECTS {
historyControlIndex, historyControlDataSource,
historyControlBucketsRequested,
historyControlBucketsGranted, historyControlInterval,
historyControlOwner, historyControlStatus
}
STATUS current
DESCRIPTION
"The RMON History Control Group."
::= { rmonGroups 2 }
rmonEthernetHistoryGroup OBJECT-GROUP
OBJECTS {
etherHistoryIndex, etherHistorySampleIndex,
etherHistoryIntervalStart, etherHistoryDropEvents,
etherHistoryOctets, etherHistoryPkts,
etherHistoryBroadcastPkts, etherHistoryMulticastPkts,
etherHistoryCRCAlignErrors, etherHistoryUndersizePkts,
etherHistoryOversizePkts, etherHistoryFragments,
etherHistoryJabbers, etherHistoryCollisions,
etherHistoryUtilization
}
STATUS current
DESCRIPTION
"The RMON Ethernet History Group."
::= { rmonGroups 3 }
rmonAlarmGroup OBJECT-GROUP
OBJECTS {
alarmIndex, alarmInterval, alarmVariable,
alarmSampleType, alarmValue, alarmStartupAlarm,
alarmRisingThreshold, alarmFallingThreshold,
alarmRisingEventIndex, alarmFallingEventIndex,
alarmOwner, alarmStatus
}
STATUS current
DESCRIPTION
"The RMON Alarm Group."
::= { rmonGroups 4 }
rmonHostGroup OBJECT-GROUP
OBJECTS {
hostControlIndex, hostControlDataSource,
hostControlTableSize, hostControlLastDeleteTime,
hostControlOwner, hostControlStatus,
hostAddress, hostCreationOrder, hostIndex,
hostInPkts, hostOutPkts, hostInOctets,
hostOutOctets, hostOutErrors, hostOutBroadcastPkts,
hostOutMulticastPkts, hostTimeAddress,
hostTimeCreationOrder, hostTimeIndex,
hostTimeInPkts, hostTimeOutPkts, hostTimeInOctets,
hostTimeOutOctets, hostTimeOutErrors,
hostTimeOutBroadcastPkts, hostTimeOutMulticastPkts
}
STATUS current
DESCRIPTION
"The RMON Host Group."
::= { rmonGroups 5 }
rmonHostTopNGroup OBJECT-GROUP
OBJECTS {
hostTopNControlIndex, hostTopNHostIndex,
hostTopNRateBase, hostTopNTimeRemaining,
hostTopNDuration, hostTopNRequestedSize,
hostTopNGrantedSize, hostTopNStartTime,
hostTopNOwner, hostTopNStatus,
hostTopNReport, hostTopNIndex,
hostTopNAddress, hostTopNRate
}
STATUS current
DESCRIPTION
"The RMON Host Top 'N' Group."
::= { rmonGroups 6 }
rmonMatrixGroup OBJECT-GROUP
OBJECTS {
matrixControlIndex, matrixControlDataSource,
matrixControlTableSize, matrixControlLastDeleteTime,
matrixControlOwner, matrixControlStatus,
matrixSDSourceAddress, matrixSDDestAddress,
matrixSDIndex, matrixSDPkts,
matrixSDOctets, matrixSDErrors,
matrixDSSourceAddress, matrixDSDestAddress,
matrixDSIndex, matrixDSPkts,
matrixDSOctets, matrixDSErrors
}
STATUS current
DESCRIPTION
"The RMON Matrix Group."
::= { rmonGroups 7 }
rmonFilterGroup OBJECT-GROUP
OBJECTS {
filterIndex, filterChannelIndex, filterPktDataOffset,
filterPktData, filterPktDataMask,
filterPktDataNotMask, filterPktStatus,
filterPktStatusMask, filterPktStatusNotMask,
filterOwner, filterStatus,
channelIndex, channelIfIndex, channelAcceptType,
channelDataControl, channelTurnOnEventIndex,
channelTurnOffEventIndex, channelEventIndex,
channelEventStatus, channelMatches,
channelDescription, channelOwner, channelStatus
}
STATUS current
DESCRIPTION
"The RMON Filter Group."
::= { rmonGroups 8 }
rmonPacketCaptureGroup OBJECT-GROUP
OBJECTS {
bufferControlIndex, bufferControlChannelIndex,
bufferControlFullStatus, bufferControlFullAction,
bufferControlCaptureSliceSize,
bufferControlDownloadSliceSize,
bufferControlDownloadOffset,
bufferControlMaxOctetsRequested,
bufferControlMaxOctetsGranted,
bufferControlCapturedPackets,
bufferControlTurnOnTime,
bufferControlOwner, bufferControlStatus,
captureBufferControlIndex, captureBufferIndex,
captureBufferPacketID, captureBufferPacketData,
captureBufferPacketLength, captureBufferPacketTime,
captureBufferPacketStatus
}
STATUS current
DESCRIPTION
"The RMON Packet Capture Group."
::= { rmonGroups 9 }
rmonEventGroup OBJECT-GROUP
OBJECTS {
eventIndex, eventDescription, eventType,
eventCommunity, eventLastTimeSent,
eventOwner, eventStatus,
logEventIndex, logIndex, logTime,
logDescription
}
STATUS current
DESCRIPTION
"The RMON Event Group."
::= { rmonGroups 10 }
rmonNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { risingAlarm, fallingAlarm }
STATUS current
DESCRIPTION
"The RMON Notification Group."
::= { rmonGroups 11 }
END
That's the whole MIB module, bestie! ๐โจ
6. Security Considerations โจ
okay bestie, this section is SO important, so let's get into it ๐๐
In order to implement this MIB, a probe has to capture all packets on the locally-attached network, including packets between third parties ๐ Those packets get analyzed to collect network addresses, protocol usage info, and conversation statistics. Data like this can be considered sensitive in some environments, so the administrator may want to restrict SNMP access to the probe ๐๐
This MIB also has functions for returning the contents of captured packets, which could include sensitive user data or passwords ๐ญ It is recommended that SNMP access to these functions be restricted ๐ซถ
There are a bunch of management objects in this MIB with a MAX-ACCESS clause of read-write and/or read-create. Those objects may be considered sensitive or vulnerable in some network environments ๐จ Supporting SET operations in a non-secure environment without proper protection can have a negative effect on network operations, so be careful, periodt ๐
SNMPv1 by itself is not a secure environment. Even if the network itself is secure (for example by using IPSec), there is still no control over who on that secure network is allowed to access and GET/SET (read/change/create/delete) the objects in this MIB ๐ค Like, the lock on the door doesn't tell you who has the key ๐๏ธ
It is recommended that implementors consider the security features provided by the SNMPv3 framework. Specifically, the use of the User-based Security Model RFC 2574 [12] and the View-based Access Control Model RFC 2575 [15] is recommended ๐ธโจ
It is then a customer/user responsibility to make sure the SNMP entity giving access to an instance of this MIB is properly configured, so access to the objects is only given to those principals (users) who have legitimate rights to GET or SET (change/create/delete) them ๐ Main character energy means only the right people get the keys ๐
7. Acknowledgments ๐
This document was produced by the IETF Remote Network Monitoring Working Group ๐ง
8. Author's Address ๐
Steve Waldbusser
Phone: +1-650-948-6500 Fax: +1-650-745-0671 Email: waldbusser@nextbeacon.com
9. References ๐
[1] Harrington, D., Presuhn, R., and B. Wijnen, "An Architecture for
Describing SNMP Management Frameworks", RFC 2571, April 1999.
[2] Rose, M. and K. McCloghrie, "Structure and Identification of
Management Information for TCP/IP-based Internets", STD 16, RFC
1155, May 1990.
[3] Rose, M. and K. McCloghrie, "Concise MIB Definitions", STD 16,
RFC 1212, March 1991.
[4] Rose, M., "A Convention for Defining Traps for use with the
SNMP", RFC 1215, March 1991.
[5] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
M. and S. Waldbusser, "Structure of Management Information
Version 2 (SMIv2)", STD 58, RFC 2578, April 1999.
[6] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
M. and S. Waldbusser, "Textual Conventions for SMIv2", STD 58,
RFC 2579, April 1999.
[7] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose,
M. and S. Waldbusser, "Conformance Statements for SMIv2", STD
58, RFC 2580, April 1999.
[8] Case, J., Fedor, M., Schoffstall, M. and J. Davin, "Simple
Network Management Protocol", STD 15, RFC 1157, May 1990.
[9] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
"Introduction to Community-based SNMPv2", RFC 1901, January
1996.
[10] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Transport
Mappings for Version 2 of the Simple Network Management Protocol
(SNMPv2)", RFC 1906, January 1996.
[11] Case, J., Harrington D., Presuhn R. and B. Wijnen, "Message
Processing and Dispatching for the Simple Network Management
Protocol (SNMP)", RFC 2572, April 1999.
[12] Blumenthal, U. and B. Wijnen, "User-based Security Model (USM)
for version 3 of the Simple Network Management Protocol
(SNMPv3)", RFC 2574, April 1999.
[13] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Protocol
Operations for Version 2 of the Simple Network Management
Protocol (SNMPv2)", RFC 1905, January 1996.
[14] Levi, D., Meyer, P. and B. Stewart, "SNMPv3 Applications", RFC
2573, April 1999.
[15] Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based Access
Control Model (VACM) for the Simple Network Management Protocol
(SNMP)", RFC 2575, April 1999.
[16] McCloghrie, K. and M. Rose, Editors, "Management Information
Base for Network Management of TCP/IP-based internets: MIB-II",
STD 17, RFC 1213, March 1991.
[17] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB
using SMIv2", RFC 2233, November 1997.
[18] Waldbusser, S., "Remote Network Monitoring MIB", RFC 1757,
February 1995.
[19] Waldbusser, S., "Token Ring Extensions to the Remote Network
Monitoring MIB", RFC 1513, September 1993.
[20] Waldbusser, S., "Remote Network Monitoring Management
Information Base Version 2 using SMIv2", RFC 2021, January 1997.
[21] Waterman, R., Lahaye, B., Romascanu, D. and S. Waldbusser,
"Remote Network Monitoring MIB Extensions for Switched Networks
Version 1.0", RFC 2613, June 1999.
[22] Case, J., Mundy, R., Partain, D. and B. Stewart, "Introduction
to Version 3 of the Internet-standard Network Management
Framework", RFC 2570, April 1999.
10. Intellectual Property ๐ง
The IETF takes no position regarding the validity or scope of any intellectual property or other rights that might be claimed to pertain to the implementation or use of the technology described in this document, or the extent to which any license under such rights might or might not be available. It also doesn't represent that it has made any effort to identify any such rights. Information on the IETF's procedures with respect to rights in standards-track and standards-related documentation can be found in BCP-11. Copies of claims of rights made available for publication, any assurances of licenses to be made available, or the result of an attempt made to obtain a general license or permission for the use of such proprietary rights by implementors or users of this specification can be obtained from the IETF Secretariat ๐ฌ
The IETF invites any interested party to bring to its attention any copyrights, patents or patent applications, or other proprietary rights which may cover technology that may be required to practice this standard. Please address the information to the IETF Executive Director ๐ผ
11. Full Copyright Statement ยฉ๏ธ
Copyright (C) The Internet Society (2000). All Rights Reserved.
This document and translations of it may be copied and furnished to others, and derivative works that comment on or otherwise explain it or assist in its implementation may be prepared, copied, published and distributed, in whole or in part, without restriction of any kind, provided that the above copyright notice and this paragraph are included on all such copies and derivative works. However, this document itself may not be modified in any way, such as by removing the copyright notice or references to the Internet Society or other Internet organizations, except as needed for the purpose of developing Internet standards in which case the procedures for copyrights defined in the Internet Standards process must be followed, or as required to translate it into languages other than English ๐
The limited permissions granted above are perpetual and will not be revoked by the Internet Society or its successors or assigns ๐
This document and the information contained herein is provided on an "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ๐ซ
Acknowledgement ๐ท
Funding for the RFC Editor function is currently provided by the Internet Society ๐
๐ฆ where this page comes from
- ietf: rfc2819 2000-05
- ๐ girlified by claude-haiku-5-5 on : a language model's rewrite of the original, under its terms