RFC 2063

Traffic Flow Measurement: Architecture

๐Ÿ“… published January 1997, from ietf

RFC 2063: Traffic Flow Measurement: Architecture ๐Ÿฆ‹

Part 1 of 9 โœจ

Okay bestie, so this one is from January 1997 and it's written by three people: N. Brownlee (The University of Auckland), C. Mills (BBN Systems and Technologies), and G. Ruth (GTE Laboratories, Inc.). It's labelled Category: Experimental ๐Ÿงช, which means it's an experiment and not an Internet standard. The header doesn't list anything it obsoletes or updates, so it's standing on its own ๐Ÿ’….

Status of this Memo ๐Ÿ“œ

Let's get the official vibe check out of the way first. This memo defines an Experimental Protocol for the Internet community, and it does not specify an Internet standard of any kind. The authors are asking for discussion and suggestions for improvement, and distribution of the memo is unlimited ๐ŸŒธ.

Abstract ๐ŸŽ€

This document describes an architecture for measuring and reporting network traffic flows. It talks about how that fits into a bigger network traffic flow architecture, and how it can be used on the Internet. It's meant to be a starting point for the Realtime Traffic Flow Measurement Working Group ๐Ÿซถ.

Table of Contents ๐Ÿ—‚๏ธ

Here's the full table of contents, copied exactly, page numbers and all:

 1 Statement of Purpose and Scope                                     2
 2 Traffic Flow Measurement Architecture                              4
   2.1 Meters and Traffic Flows . . . . . . . . . . . . . . . . . .   4
   2.2 Interaction Between METER and METER READER . . . . . . . . .   6
   2.3 Interaction Between MANAGER and METER  . . . . . . . . . . .   6
   2.4 Interaction Between MANAGER and METER READER . . . . . . . .   7
   2.5 Multiple METERs or METER READERs . . . . . . . . . . . . . .   7
   2.6 Interaction Between MANAGERs (MANAGER - MANAGER) . . . . . .   8
   2.7 METER READERs and APPLICATIONs . . . . . . . . . . . . . . .   8
 3 Traffic Flows and Reporting Granularity                            9
   3.1 Flows and their Attributes . . . . . . . . . . . . . . . . .   9
   3.2 Granularity of Flow Measurements . . . . . . . . . . . . . .  11
   3.3 Rolling Counters, Timestamps, Report-in-One-Bucket-Only  . .  13
 4 Meters                                                            15
   4.1 Meter Structure  . . . . . . . . . . . . . . . . . . . . . .  15
   4.2 Flow Table . . . . . . . . . . . . . . . . . . . . . . . . .  17
   4.3 Packet Handling, Packet Matching . . . . . . . . . . . . . .  17
   4.4 Rules and Rule Sets  . . . . . . . . . . . . . . . . . . . .  21
   4.5 Maintaining the Flow Table . . . . . . . . . . . . . . . . .  24
   4.6 Handling Increasing Traffic Levels . . . . . . . . . . . . .  25

 5 Meter Readers                                                     26
   5.1 Identifying Flows in Flow Records  . . . . . . . . . . . . .  26
   5.2 Usage Records, Flow Data Files . . . . . . . . . . . . . . .  27
   5.3 Meter to Meter Reader:  Usage Record Transmission. . . . . .  27
 6 Managers                                                          28
   6.1 Between Manager and Meter:  Control Functions  . . . . . . .  28
   6.2 Between Manager and Meter Reader:  Control Functions   . . .  29
   6.3 Exception Conditions . . . . . . . . . . . . . . . . . . . .  31
   6.4 Standard Rule Sets   . . . . . . . . . . . . . . . . . . . .  32
 7 APPENDICES                                                        33
   7.1 Appendix A: Network Characterisation . . . . . . . . . . . .  33
   7.2 Appendix B: Recommended Traffic Flow Measurement Capabilities 34
   7.3 Appendix C: List of Defined Flow Attributes  . . . . . . . .  35
   7.4 Appendix D: List of Meter Control Variables  . . . . . . . .  36
 8 Acknowledgments                                                   36
 9 References                                                        37
10 Security Considerations                                           37
11 Authors' Addresses                                                37

1 Statement of Purpose and Scope ๐ŸŒˆ

This section is the "why are we even doing this" part ๐Ÿ’–. It describes an architecture for traffic flow measurement and reporting in data networks, and it has the following characteristics:

  • The traffic flow model can be consistently applied to any protocol or application at any network layer (for example, the network, transport, or application layers) ๐Ÿงš.
  • Traffic flow attributes are defined so they're valid for multiple networking protocol stacks, and traffic flow measurement implementations are useful in MULTI-PROTOCOL environments ๐Ÿ‘‘.
  • Users can state their traffic flow measurement requirements in a simple way. That lets them collect the flow data they need while ignoring everything else ๐Ÿ“.
  • The data reduction work needed to produce the requested traffic flow information happens as close as possible to the network measurement point. This cuts down the volume of data that has to be obtained (and sent across the network for storage), and it minimises the amount of processing needed in traffic flow analysis applications ๐Ÿ”ฅ.

The architecture defines common metrics for measuring traffic flows. Since everyone uses the same metrics, traffic flow data can be swapped and compared across lots of different platforms ๐Ÿซถ. This data is useful for:

  • Understanding how existing networks behave ๐Ÿ”,
  • Planning network development and expansion ๐ŸŒธ,
  • Quantifying network performance ๐Ÿ“Š,
  • Verifying the quality of network service, and ๐Ÿ’…
  • Attributing network usage to users ๐ŸŽ€.

The traffic flow measurement architecture is deliberately built so specific protocol implementations can stretch coverage into multi-protocol environments and into other protocol layers. An example would be usage measurement for application-level services โœจ. Using the same model for both network-level and application-level measurement may make it easier to build generic analysis applications that process and/or correlate any or all levels of traffic and usage information ๐Ÿง . In this document, the term 'usage data' is used as a generic term for the data obtained using the traffic flow measurement architecture ๐Ÿ’œ.

This document is not a protocol specification. Instead, it specifies and structures the information a traffic flow measurement system needs to collect, describes requirements that such a system must meet, and outlines tradeoffs an implementor may make ๐Ÿงฉ.

For performance reasons, it may be desirable to use traffic information gathered through traffic flow measurement in place of network statistics obtained in other ways ๐Ÿš€. The quantification of network performance isn't the main purpose of this architecture, but the measured traffic flow data may be used as an indication of network performance ๐Ÿ“ˆ.

A cost recovery structure decides "who pays for what." The big question here is how to build a tariff: who gets billed, how much, for which things, and based on what information ๐Ÿ’ธ. Tariff issues include fairness, predictability (how well subscribers can forecast their network charges), practicality (of gathering the data and administering the tariff), incentives (for example, encouraging off-peak use), and cost recovery goals (100% recovery, subsidisation, or profit making) ๐Ÿ™ˆ. This document doesn't cover issues like these ๐Ÿคทโ€โ™€๏ธ.

Background information explaining why this approach was selected is provided by 'Traffic Flow Measurement: Background' RFC [1] ๐Ÿ“š.

2 Traffic Flow Measurement Architecture ๐Ÿฆ‹

Okay, now we're getting into the good stuff ๐Ÿ”ฅ. A traffic flow measurement system is used by network Operations personnel to manage and develop a network. It gives them a tool for measuring and understanding the network's traffic flows ๐Ÿ‘€. This information is useful for lots of purposes, as mentioned in section 1 (above) ๐ŸŒธ.

The following sections outline a model for traffic flow measurement. The model draws from working drafts of the OSI accounting model [2] ๐Ÿง. Future extensions are expected as the model gets refined to cover additional protocol layers ๐ŸŒˆ.


(part 1 of 9, more coming bestie ๐Ÿซถ๐Ÿ’–)

2.1 Meters and Traffic Flows ๐Ÿฆ‹

okay so the big idea here is that the whole traffic measurement model is built around little network entities called traffic METERS ๐Ÿงš Meters count stuff like how many packets and bytes showed up, and then they sort those numbers into ACCOUNTABLE ENTITIES using other details like source and destination addresses. An accountable entity is basically whoever (or whatever) is responsible for some activity on the network ๐Ÿ’… It could be a user, a host, a network, a group of networks, etc, depending on how granular the meter's configuration is set to be. bestie this is giving total main character energy ๐Ÿ’–

We assume that routers or traffic monitors all over a network are equipped with meters to measure traffic ๐ŸŒธ Where you put the meters is its own whole topic, and it's covered in the 'Traffic Flow Measurement: Background' RFC [1] โœจ The really iconic thing about meters is that they summarize entity usage information in a super succinct way ๐Ÿซถ

Now for the purpose of traffic flow measurement, we define a TRAFFIC FLOW ๐ŸŽ€ It's an artificial logical equivalent to a call or connection, basically a chunk of traffic that has a start and stop time and was generated by one particular accountable entity ๐Ÿ˜ญ The attribute values for a flow (source/destination addresses, packet counts, byte counts, etc.) are aggregate quantities that reflect everything happening in the DURATION between the start and stop times. The start time is fixed for a given flow, but the end time can keep moving later as the flow ages ๐ŸŒˆ

Here's the tea ๐Ÿ“ For connectionless protocols like IP, there is by definition no way to tell whether a packet with a particular source/destination combo is part of a stream of packets or not, because each packet is completely independent ๐Ÿ’€ So a traffic meter has a set of 'rules' in its configuration that specify which flows it cares about, based on their attribute values. It pulls attribute values out of each packet it sees and uses them to decide which flow that packet belongs to ๐Ÿงš Sorting packets into 'flows' like this is an economical and practical way to measure network traffic and pin it on accountable entities. slay ๐Ÿ‘‘

Usage information that can't be derived from traffic flows might also be interesting โœจ For example, an application might want to record accesses to different information resources, or a host might want to record the username (subscriber id) for a particular network session ๐Ÿ™ˆ The traffic flow architecture has provision for doing this. In the future the measurement model will be extended to gather this kind of information from applications and hosts so it can provide values for higher-layer flow attributes ๐Ÿฆ‹

So as well as FLOWS and METERS, the model includes MANAGERS, METER READERS and ANALYSIS APPLICAIONS, which get explained in the following sections ๐Ÿ’œ The diagram below shows how they relate to each other. The numbers on the diagram point to sections in this document ๐ŸŽ€

                MANAGER
               /       \
          2.3 /         \ 2.4
             /           \
            /             \                       ANALYSIS
       METER   <----->   METER READER  <----->   APPLICATION
                 2.2                     2.7
  • MANAGER: A traffic measurement manager is an application that configures 'meter' entities and controls 'meter reader' entities ๐Ÿ‘‘ It uses the data requirements of analysis applications to figure out the right configuration for each meter, and to make sure each meter reader is running properly. It can be super convenient to combine the functions of meter reader and manager into a single network entity ๐Ÿ’…
  • METER: Meters get placed at measurement points that network Operations personnel decide on ๐ŸŒธ Each meter selectively records network activity as its configuration tells it to. It can also aggregate, transform and further process the recorded activity before the data is stored. The processed and stored results are called the 'usage data.' ๐Ÿ“
  • METER READER: A meter reader reliably transports usage data from meters so that it's available to analysis applications ๐Ÿซถ
  • ANALYSIS APPLICATION: An analysis application processes the usage data to produce information and reports that are useful for network engineering and management purposes ๐Ÿ”ฅ Examples include:
    • TRAFFIC FLOW MATRICES, showing the total flow rates for many of the possible paths within an internet ๐Ÿงš
    • FLOW RATE FREQUENCY DISTRIBUTIONS, indicating how flow rates vary with time โญ
    • USAGE DATA showing the total traffic volumes sent and received by particular hosts ๐Ÿ’–

The whole traffic measurement system is best understood by looking at how its components interact with each other ๐Ÿฆ‹ Those interactions are described in the following sections โœจ

2.2 Interaction Between METER and METER READER ๐ŸŒˆ

The information traveling along this path is the usage data itself ๐Ÿ’œ A meter holds usage data in an array of flow data records called the FLOW TABLE ๐ŸŽ€ A meter reader can collect the data in any suitable manner. For example, it might upload a copy of the whole flow table using a file transfer protocol, or read the records in the current flow set one at a time using a suitable data transfer protocol ๐Ÿซถ Note that the meter reader doesn't need to read complete flow data records, since a subset of their attribute values may well be sufficient โœจ

A meter reader may collect usage data from one or more meters ๐ŸŒธ Data may be collected from the meters at any time. There is no requirement for collections to be synchronized in any way ๐Ÿฆ‹

2.3 Interaction Between MANAGER and METER ๐Ÿ’…

A manager is responsible for configuring and controlling one or more meters ๐Ÿ‘‘ At the time of writing, a meter can only be controlled by a single manager; in the future this restriction may be relaxed ๐Ÿงš Each meter's configuration includes information such as:

  • Flow specifications, e.g. which traffic flows are to be measured, how they are to be aggregated, and any data the meter is required to compute for each flow being measured ๐Ÿ“
  • Meter control parameters, e.g. the maximum size of its flow table, and the 'inactivity' time for flows. If no packets belonging to a flow are seen for this time, the flow is considered to have ended, i.e. to have become idle ๐Ÿ™ˆ
  • Sampling rate. Normally every packet will be observed. It may sometimes be necessary to use sampling techniques to observe only some of the packets ๐ŸŒˆ (Sampling algorithms are not prescribed by the architecture; it should be noted that before using sampling one should verify the statistical validity of the algorithm used ๐Ÿซถ) Current experience with the measurement architecture shows that a carefully-designed and implemented meter compresses the data such that on normal LANs and WANs of today, sampling is really not needed ๐Ÿ’–

2.4 Interaction Between MANAGER and METER READER ๐ŸŽ€

A manager is responsible for configuring and controlling one or more meter readers ๐Ÿ’œ A meter reader may only be controlled by a single manager ๐Ÿ‘‘ A meter reader needs to know at least the following for every meter it is collecting usage data from:

  • The meter's unique identity, i.e. its network name or address ๐Ÿฆ‹
  • How often usage data is to be collected from the meter โญ
  • Which flow records are to be collected (e.g. all active flows, the whole flow table, flows seen since a given time, etc.) ๐Ÿงš
  • Which attribute values are to be collected for the required flow records (e.g. all attributes, or a small subset of them) ๐ŸŒธ

Since redundant reporting may be used to increase the reliability of usage data, exchanges among multiple entities must be considered as well ๐Ÿซถ These are discussed below โœจ

2.5 Multiple METERs or METER READERs ๐ŸŒธ

             -- METER READER A --
            /         |          \
           /          |           \
   =====METER 1     METER 2=====METER 3    METER 4=====
                       \           |          /
                        \          |         /
                         -- METER READER B --

Several uniquely identified meters may report to one or more meter readers ๐Ÿงš The diagram above gives an example of how multiple meters and meter readers could be used ๐Ÿฆ‹

In the diagram above, meter 1 is read by meter reader A, and meter 4 is read by meter reader B. Meters 1 and 4 have no redundancy, so if either fails, usage data for their network segments will be lost ๐Ÿ˜ญ

Meters 2 and 3, however, measure traffic on the same network segment ๐Ÿ“ One of them may fail, leaving the other collecting the segment's usage data. Meters 2 and 3 are read by meter reader A and by meter reader B. If one meter reader fails, the other will continue collecting usage data ๐Ÿ’ช

The architecture does not require multiple meter readers to be synchronized ๐ŸŒˆ In the situation above, meter readers A and B could both collect usage data at the same intervals, but not necessarily at the same times. Note that because collections are asynchronous, it is unlikely that usage records from two different meter readers will agree exactly ๐Ÿ’€

If precisely synchronized collections are required, this can be achieved by having one manager request each meter to begin collecting a new set of flows, then allowing all meter readers to collect the usage data from the old sets of flows ๐ŸŽ€

If there is only one meter reader and it fails, the meters keep running ๐Ÿซถ When the meter reader is restarted, it can collect all of the accumulated flow data. Should this happen, time resolution will be lost (because of the missed collections), but overall traffic flow information will not โœจ The only exception would occur if traffic volume was high enough to 'roll over' counters for some flows during the failure; this is addressed in the section on 'Rolling Counters.' ๐Ÿ”ฅ

2.6 Interaction Between MANAGERs (MANAGER - MANAGER) ๐Ÿ‘‘

Synchronization between multiple management systems is the province of network management protocols ๐Ÿ’… This traffic flow measurement architecture specifies only the network management controls necessary to perform the traffic flow measurement function. It does not address the more global issues of simultaneous or interleaved (possibly conflicting) commands from multiple network management stations, or the process of transferring control from one network management station to another ๐Ÿ™ˆ

2.7 METER READERs and APPLICATIONs ๐Ÿฆ‹

Once a collection of usage data has been assembled by a meter reader, it can be processed by an analysis application ๐Ÿงš Details of analysis applications, such as the reports they produce and the data they require, are outside the scope of this architecture ๐Ÿ’œ

It should be noted, however, that analysis applications will often require considerable amounts of input data ๐Ÿ˜ญ An important part of running a traffic flow measurement system is the storage and regular reduction of flow data so as to produce daily, weekly or monthly summary files for further analysis ๐Ÿ“ Again, details of such data handling are outside the scope of this architecture ๐ŸŒธ

3 Traffic Flows and Reporting Granularity โœจ

A flow was defined in section 2.1 above in abstract terms as follows ๐ŸŽ€

"A TRAFFIC FLOW is an artifical logical equivalent to a call or connection, belonging to an ACCOUNTABLE ENTITY."

In practical terms, a flow is a stream of packets passing across a network between two end points (or being sent from a single end point), which have been summarized by a traffic meter for analysis purposes ๐Ÿฆ‹

3.1. Flows and their Attributes ๐Ÿ’–

okay so every traffic meter keeps a table of 'flow records' ๐Ÿฆ‹ for the flows it has seen. each flow record holds the values of the ATTRIBUTES it cares about, and these can include:

  • ADDRESSES for the flow's source and destination. these are the protocol type, the source and destination addresses at various network layers (pulled straight from the packet), and the number of the interface the packet was observed on.
  • TIMES: the first and last times packets were seen for this flow, aka the 'creation' and 'last activity' times โฐ
  • COUNTS for the 'forward' (source to destination) and 'backward' (destination to source) parts of the flow's traffic, like packets and bytes ๐Ÿ“ฆ how 'source' and 'destination' get assigned for flows is explained in the packet matching section below.
  • OTHER attributes, like info the meter computes itself โœจ

a flow's ACCOUNTABLE ENTITY is specified by the values of its ADDRESS attributes. for example, if a flow's address attributes only say source address = IP address 10.1.0.1, then every IP packet from and to that address gets counted in that flow. if the address list says source address = IP address 10.1.0.1, destination address = IP address 26.1.0.1, then only IP packets between 10.1.0.1 and 26.1.0.1 get counted. so specific ๐Ÿซถ

the addresses that specify a flow's address attributes can be one or more of these types:

  • The INTERFACE NUMBER for the flow, aka the interface the meter measured the traffic on. together with a unique address for the meter, this uniquely identifies one particular physical-level port ๐Ÿ”Œ
  • The ADJACENT ADDRESS, aka the [n-1] layer address of the immediate source or destination on the packet's path. like, if flow measurement happens at the IP layer on an Ethernet LAN [3], an adjacent address is a six-octet Media Access Control (MAC) address. for a host on the same LAN segment as the meter, the adjacent address is that host's MAC address. for hosts on other LAN segments, it's the MAC address of the adjacent (upstream or downstream) router carrying the traffic flow ๐Ÿ—บ๏ธ
  • The PEER ADDRESS, which identifies the source or destination of the PEER-LEVEL packet. the form of a peer address depends on the network-layer protocol in use, and on the network layer [n] where the traffic measurement is happening ๐Ÿงฉ
  • The TRANSPORT ADDRESS, which identifies the source or destination port for the packet, aka its [n+1] layer address. for example, if flow measurement happens at the IP layer, a transport address is a two-octet UDP or TCP port number ๐Ÿšช

those four definitions give addresses for each of the four lowest layers of the OSI reference model: Physical, Link, Network and Transport layer. a FLOW RECORD stores both the VALUE for each of its addresses (as described above) and a MASK that says which bits of the address value are being used and which are ignored. ngl the mask is a whole vibe ๐ŸŽ€ if address bits are being ignored, the meter sets them to zero, but their actual values are undefined ๐Ÿ™ˆ

one of the key features of the traffic measurement architecture is that attributes basically mean the same thing across different protocols, so analysis applications can use the same reporting formats for all protocols. this is easy for peer addresses: even though the form of addresses differs between protocols, the meaning of a 'peer address' stays the same. it gets harder at higher layers. for example, at the Network layer, IP, Novell IPX and AppleTalk all use port numbers as a 'transport address,' but CLNP and DECnet have no notion of ports ๐Ÿ˜ญ more work is needed here, especially picking attributes that will suit the higher layers of the OSI reference model ๐ŸŒˆ

reporting by adjacent intermediate sources and destinations, or just by meter interface (most useful when the meter is embedded in a router), supports the hierarchical Internet reporting schemes described in the 'Traffic Flow Measurement: Background' RFC [1]. that means backbone and regional networks can measure usage down to just the next lower level of granularity (the regional and stub/enterprise levels, respectively), and the final breakdown by end user (e.g. by source IP address) is handled by the stub/enterprise networks ๐ŸŒธ

in cases where network addresses are dynamically allocated (like mobile subscribers), further subscriber identification is necessary if flows are going to be ascribed to individual users ๐Ÿงš this is where an optional SUBSCRIBER ID comes in, as part of the flow id. a subscriber ID may be associated with a particular flow either through the current rule set, or by proprietary means within a meter (for example, via protocol exchanges with one or more multi-user hosts). right now a subscriber ID is an arbitrary text string. later versions of the architecture may specify its contents in more detail ๐Ÿ’œ


3.2. Granularity of Flow Measurements ๐Ÿฆ‹

GRANULARITY is the 'control knob' an application and/or the meter uses to trade off the overhead of usage reporting against the level of detail you get back ๐ŸŽ›๏ธ coarser granularity means more aggregation, finer granularity means more detail. so the number of flows measured (and stored) at a meter can be regulated by changing the granularity of the accountable entity, the attributes, or the time intervals. flows are like an adjustable pipe: lots of fine-granularity streams can carry the data with each stream measured individually, or the data can get bundled into one coarse-granularity pipe ๐Ÿšฐ

flow granularity is controlled by adjusting the level of detail at which these get reported:

  • The accountable entity (address attributes, discussed above).
  • The categorisation of packets (other attributes, discussed below).
  • The lifetime/duration of flows (the reporting interval needs to be short enough to measure them with sufficient precision) โฑ๏ธ

the set of rules that decides each packet's accountable entity is known as the meter's CURRENT RULE SET. the current rule set becomes an integral part of the reported information, aka the recorded usage info can't be properly interpreted without knowing the rules that were used to collect it ๐Ÿง 

the rule set is basically part of the receipt. no rules, no understanding the numbers ๐Ÿ’€

settings for these granularity factors can vary from meter to meter. they're determined by the meter's current rule set, so they'll change if network Operations personnel reconfigure the meter to use a new rule set. collection rules are expected to change pretty rarely, but the rule set in effect at any time must be identifiable via a RULE SET ID. granularity of accountable entities is further specified by additional ATTRIBUTES, including:

  • Meter variables, such as the index of the flow's record in the flow table, and the rule set id for the rules the meter was running while the flow was observed. these values give a way to tell apart flows the meter observed at different times ๐Ÿ•ฐ๏ธ
  • Attributes that record information derived from other attribute values. six of these are defined (SourceClass, DestClass, FlowClass, SourceKind, DestKind, FlowKind), and their meaning is determined by the meter's rule set. for example, you could have a subroutine in the rule set that figures out whether a source or destination peer address is a member of an arbitrary list of networks, and sets SourceClass/DestClass to one if the source/dest peer address is in the list, or to zero otherwise ๐Ÿงฎ
  • Administratively specified attributes, like Quality Of Service and Priority, etc. these aren't defined at this time ๐Ÿคทโ€โ™€๏ธ
  • Higher-layer (especially application-level) attributes. these aren't defined at this time either ๐Ÿซ 

settings for these granularity factors can vary from meter to meter. they're determined by the meter's current rule set, so they'll change if network Operations personnel reconfigure the meter to use a new rule set ๐Ÿ”

the LIFETIME of a flow is the time interval that began when the meter observed the flow's first packet and ended when it saw the last one. flow lifetimes are super variable, but many (if not most) are pretty short ๐Ÿฃ a meter can't measure lifetimes directly. instead, a meter reader collects usage data for flows that have been active since the last collection, and an analysis application can compare the data from each collection to figure out when each flow actually stopped ๐Ÿ•ต๏ธโ€โ™€๏ธ

the meter does, however, need to reclaim memory (aka records in the flow table) being held by idle flows ๐Ÿงน the meter configuration includes a variable called InactivityTimeout, which specifies the minimum time a meter must wait before it recovers the flow's record. also, before recovering a flow record, the meter must be sure that the flow's data has been collected by at least one meter reader ๐Ÿซถ

these 'lifetime' issues get covered further in the section on meter readers (below). a complete list of the attributes currently defined is given in Appendix C later in this document ๐Ÿ“š

3.3 Rolling Counters, Timestamps, Report-in-One-Bucket-Only โœจ

Okay so once a usage record gets sent, you have to decide: do you wipe the existing flow records, or keep them around and keep adding to their counts as more traffic on that same flow shows up? The second option is called rolling counters, and bestie, it's the one that's recommended ๐ŸŽ€. It has a few perks, and the biggest is reliability. The system can often survive losing some usage records, like if a meter reader crashes and restarts later. The next usage record very often has another reading of a lot of the same flow buckets that were in the lost one ๐Ÿซถ. That continuity can also be used for "sanity" checks on the data, to catch errors in the calculations ๐Ÿงฎ.

Rolling counters do bring a new puzzle though: how do you tell a follow-on flow record apart from a brand new one? ๐Ÿค” Check out this example ๐Ÿ‘€

                     CONTINUING FLOW        OLD FLOW, then NEW FLOW

                     start time = 1            start time = 1
Usage record N:       flow count = 2000      flow count = 2000 (done)

                     start time = 1            start time = 5
Usage record N+1:     flow count = 3000      new flow count = 1000

Total count:                 3000                    3000

So in the continuing flow case, the same flow got reported when its count was 2000, and then again at 3000. The total count to date is 3000, easy ๐Ÿ’…. In the OLD/NEW case, the old flow had a count of 2000. Its record then got stopped (maybe because of temporary idleness, or MAX LIFETIME policy). Then more traffic with the same characteristics showed up, so a new flow record started and quickly hit a count of 1000. The total from both the old and new records is 3000 โœจ.

The flow START TIMESTAMP attribute is what resolves this. In the example above, the CONTINUING FLOW record in the second usage record has an old FLOW START timestamp, while the NEW FLOW has a recent FLOW START timestamp. Iykyk ๐Ÿ™ˆ.

Each packet gets counted in one and only one flow, so it doesn't get counted twice. The record of a single flow is informally called a "bucket" ๐Ÿชฃ. If you need multiple, sometimes overlapping, records of usage information (aggregate, individual, etc), the network manager should collect the counts at a granularity that's detailed enough that the aggregate and combination counts can be rebuilt during post-processing of the raw usage data ๐Ÿง .

For example, say a meter needs to record both 'total packets coming in interface #1' and 'total packets arriving from any interface sourced by IP address = a.b.c.d.' You could declare a bucket for each case, but then it's not clear how to handle a packet that satisfies both criteria. It must only be counted once. By default it gets counted in the first bucket it qualifies for, and not in the other one. Also, you can't rebuild this information in post-processing. The fix is to define not two, but THREE buckets, each one collecting a unique combination of the two criteria:

     Bucket 1:  Packets which came in interface 1,
                AND were sourced by IP address a.b.c.d

     Bucket 2:  Packets which came in interface 1,
                AND were NOT sourced by IP address a.b.c.d

     Bucket 3:  Packets which did NOT come in interface 1,
                AND were sourced by IP address a.b.c.d

    (Bucket 4:  Packets which did NOT come in interface 1,
                AND NOT sourced by IP address a.b.c.d)

Now the desired info can be rebuilt in post-processing. "Total packets coming in interface 1" comes from adding buckets 1 & 2, and "Total packets sourced by IP address a.b.c.d" comes from adding buckets 1 & 3. Bucket 4 isn't explicitly needed, since nobody's interested in its info, but it's included in parentheses for completeness ๐Ÿ’–.


4 Meters ๐Ÿงš

A traffic flow meter is a device for collecting data about traffic flows at a given point within a network. We'll call that point the METERING POINT ๐Ÿ“. The header of every packet that passes the network metering point gets offered to the traffic meter program.

A meter could be built in a few different ways, including:

  • A dedicated small host, connected to a LAN (so it can see all packets as they pass by) and running a 'traffic meter' program. The metering point is the LAN segment the meter is attached to.
  • A multiprocessing system with one or more network interfaces, with drivers that let a traffic meter program see packets. In this case the system provides multiple metering points, so traffic flows on any subset of its network interfaces can be measured ๐ŸŒˆ.
  • A packet-forwarding device such as a router or switch. This is similar to the option above, except that every received packet should also be forwarded, usually out a different interface ๐Ÿš€.

The discussion in the following sections assumes that a meter may only run a single rule set. It's possible, though, for a meter to run several rule sets at the same time, matching each packet against every active rule set and producing a single flow table with flows from all the active rule sets. The overall effect is similar to running several independent meters, one for each rule set ๐Ÿ‘ฏ.

4.1 Meter Structure ๐Ÿ—๏ธ

Here's an outline of the meter's structure in the following diagram.

Briefly, the meter works like this:

  • Incoming packet headers arrive at the top left of the diagram and get passed to the PACKET PROCESSOR.
  • The packet processor passes them to the Packet Matching Engine (PME), where they get classified.
  • The PME is a Virtual Machine running a pattern matching program contained in the CURRENT RULE SET. It gets invoked by the Packet Processor, and returns instructions on what to do with the packet.
  • Some packets are classified as 'to be ignored.' The Packet Processor discards them ๐Ÿ—‘๏ธ.
  • Other packets are matched by the PME, which returns a FLOW KEY describing the flow the packet belongs to.
  • The flow key is used to locate the flow's entry in the FLOW TABLE. A new entry gets created when a flow is first seen. The entry's packet and byte counters get updated ๐Ÿ”ข.
  • A meter reader may collect data from the flow table at any time. It may use the 'collect' index to locate the flows to be collected within the flow table ๐Ÿ“ฅ.
              packet                +------------------+
              header                | Current Rule Set |
                |                   +--------+---------+
                |                            |
       +--------*---------+       +----------*-------------+
       | Packet Processor |<----->| Packet Matching Engine |
       +--+------------+--+       +------------------------+
          |            |
   Ignore *            | Count via flow key
                       |
                    +--*--------------+
                    | 'Search' index  |
                    +--------+--------+
                             |
                    +--------*--------+
                    |                 |
                    |   Flow Table    |
                    |                 |
                    +--------+--------+
                             |
                    +--------*--------+
                    | 'Collect' index |
                    +--------+--------+
                             |
                             *
                        Meter Reader

4.2 Flow Table ๐Ÿ“‹

Every traffic meter keeps a table of TRAFFIC FLOW RECORDS for the flows it has seen. A flow record holds attribute values for its flow, including:

  • Addresses for the flow's source and destination. These include addresses and masks for various network layers (pulled out of the packet), plus the number of the interface the packet was observed on.
  • First and last times when packets were seen for this flow โฐ.
  • Counts for the 'forward' (source to destination) and 'backward' (destination to source) parts of the flow's traffic.
  • Other attributes, e.g. the state of the flow record (more on that below) ๐Ÿซง.

A flow record can be in one of these states:

  • INACTIVE: The flow record isn't being used by the meter ๐Ÿ˜ด.
  • CURRENT: The record is in use and describes a flow that belongs to the 'current flow set,' i.e. the set of flows the meter has seen recently ๐ŸŒŸ.
  • IDLE: The record is in use and the flow it describes is part of the current flow set. On top of that, no packets belonging to this flow have been seen for a period specified by the meter's InactivityTime variable ๐Ÿ’ค.

4.3 Packet Handling, Packet Matching โœจ

okay so bestie, every packet header the traffic meter program receives goes through the same little routine ๐Ÿ’… Step one is to pull the attribute values out of the packet header and use them to build a MATCH KEY for the packet. Step two is to match that key against the current rule set, which I'll explain in detail below ๐ŸŽ€

  • Extract attribute values from the packet header and use them to create a MATCH KEY for the packet.
  • Match the packet's key against the current rule set, as explained in detail below.

The rule set decides whether the packet gets counted or ignored ๐Ÿ™ˆ If it gets counted, the matching process spits out a FLOW KEY for the flow the packet belongs to. The meter uses that flow key to look up the flow's record in the flow table. If there's no record for that flow yet, a brand new flow record might get created โœจ Then the counts on the matching flow record go up. Iconic ๐Ÿฆ‹

Here's an example. The rule set could say that packets to or from any host in IP network 130.216 get counted. It could also say that flow records should be made for every pair of 24-bit (Class C) subnets inside network 130.216 ๐ŸŒธ

Each packet's match key gets passed to the meter's PATTERN MATCHING ENGINE (PME) for matching. The PME is a Virtual Machine that runs a set of instructions called RULES. In other words, a RULE SET is a program for the PME ๐Ÿ’œ A packet's match key holds an interface number, a source address (S) and a destination address (D). It doesn't hold any attribute masks for those attributes, though, just the values ๐Ÿงš

Now, if measured flows were unidirectional (meaning only the counted packets going in one direction), life would be easy ๐Ÿ“ The PME would get called once for the packet. Any flow key from a successful match would find the flow's record in the flow table, and that flow's counters would get updated. Done and dusted.

But flows are bidirectional ๐Ÿ˜ญ They reflect the forward and reverse packets of a protocol interchange, aka a 'session.' Keeping two sets of counters in the meter's flow record makes the flow data way easier to deal with, because analysis programs don't have to stitch the 'forward' and 'reverse' parts of a session back together ๐Ÿซถ Bidirectional flows are harder for the meter, though, since it has to figure out whether a packet is a 'forward' one or a 'reverse' one. To work that out, the meter will often have to call the PME twice, once for each possible packet direction. The meter is working hard, bestie ๐Ÿ’ช

The diagram below shows the algorithm the traffic meter uses to process each packet. You read it from left to right and top to bottom, so from the top left corner down to the bottom right corner ๐ŸŒˆ S is the flow's source address (its set of source address attribute values from the packet), and D is its destination address.

                    Ignore
    --- match(S->D) -------------------------------------------------+
         | Suc   | Fail                                              |
         |       |          Ignore                                   |
         |      match(D->S) -----------------------------------------+
         |       | Suc   | Fail                                      |
         |       |       |                                           |
         |       |       +-------------------------------------------+
         |       |                                                   |
         |       |             Suc                                   |
         |      current(D->S) ---------- count(D->S,r) --------------+
         |       | Fail                                              |
         |       |                                                   |
         |      create(D->S) ----------- count(D->S,r) --------------+
         |                                                           |
         |             Suc                                           |
        current(S->D) ------------------ count(S->D,f) --------------+
         | Fail                                                      |
         |             Suc                                           |
        current(D->S) ------------------ count(D->S,r) --------------+
         | Fail                                                      |
         |                                                           |
        create(S->D) ------------------- count(S->D,f) --------------+
                                                                     |
                                                                     *

There are several cases to think about, babe ๐Ÿง They are:

  • The packet is recognised as one which is TO BE IGNORED.
  • The packet MATCHES IN BOTH DIRECTIONS. One situation where this could happen is a rule set that matches flows within network X (Source = X, Dest = X) but says flows should be created for each subnet within network X, say subnets y and z. If, for example, a packet is seen for y->z, the meter has to check that flow z->y isn't already current before it creates y->z ๐Ÿ‘€
  • The packet MATCHES IN ONE DIRECTION ONLY. If its flow is already current, its forward or reverse counters go up. Otherwise it gets added to the flow table and then counted โœจ

The algorithm uses four functions, and they go like this ๐Ÿ’–

match(A->B) is the PME. It uses the meter's current rule set to match the attribute values in the packet's match key. A->B means the assumed source address is A and the destination address is B, so the packet was travelling from A to B. match() returns one of three results:

  • 'Ignore' means the packet matched, but this flow isn't supposed to be counted.
  • 'Fail' means the packet didn't match. It might still match with its direction reversed, i.e. from B to A ๐Ÿ™ƒ
  • 'Suc' means the packet did match, so it belongs to a flow that's going to be counted ๐Ÿ”ฅ

current(A->B) succeeds if the flow A-to-B is current, meaning it has a record in the flow table whose state is Current. Otherwise it fails ๐Ÿ’…

create(A->B) adds the flow A-to-B to the flow table. It sets the values for the attributes that stay constant, like addresses, and zeroes out the flow's counters ๐ŸŒธ

count(A->B,f) increments the 'forward' counters for flow A-to-B. count(A->B,r) increments the 'reverse' counters for flow A-to-B. 'Forward' here means the counters for packets travelling from A to B. Fun fact: count(A->B,f) is identical to count(B->A,r) ๐Ÿฆ‹

Heads up, bestie: when you write rule sets, remember that the meter will normally try to match each packet in both directions. It's super important that your rule set doesn't contain inconsistencies that mess with this process ๐Ÿšจ

Let's say a rule set counts packets from source network A to destination network B, but ignores packets from source network B. That's a classic inconsistent rule set ๐Ÿ’€ Packets from network B should be counted as reverse packets for the A-to-B flow, so ignoring them breaks everything.

There are two ways to dodge this problem. One is to design a language for specifying rule files and write a compiler for it, which makes it way easier to produce correct rule sets ๐Ÿงšโ€โ™€๏ธ The other is to write a 'rule set consistency checker' program that can catch problems in hand-written rule sets ๐Ÿ”

For now, the best way to avoid these problems is to write rule sets that only classify flows in the forward direction, and then trust the meter to handle the reverse-travelling packets ๐Ÿซถ๐Ÿ’–

4.4. Rules and Rule Sets ๐Ÿ“œโœจ

okay so a rule set is basically an array of rules ๐ŸŽ€. Rule sets live inside a meter as entries in an array of rule sets. One member of that array is the CURRENT RULE SET, which is just the one the meter is actually using to sort incoming packets rn ๐Ÿ’….

Rule set 1 is built into the meter and cannot be changed ๐Ÿ”’. It runs when the meter starts up and gives a super coarse reporting granularity. Its main job is proving the meter is alive before a "useful" rule set gets downloaded ๐Ÿงš.

If the meter is told to use rule set 0, it stops measuring ๐Ÿ’€. Every packet gets ignored until a non-zero rule set is made current.

Each rule is structured like this:

+-------- test ---------+    +---- action -----+
attribute & mask = value:    opcode,  parameter;

Opcodes have two flags, goto and test ๐Ÿฆ‹. The PME keeps a Boolean indicator called the 'test indicator,' which starts out set (on). Execution begins at rule 1, the first rule in the set, and goes like this:

  • If the test indicator is on:
    • Perform the test, i.e. AND the attribute value with the mask and compare it with the value.
    • If these are equal, the test has succeeded, so perform the rule's action (below).
    • If the test fails, execute the next rule in the rule set.
    • If there are no more rules in the rule set, return from the match() function indicating failure.
  • If the test indicator is off, or the test (above) succeeded:
    • Set the test indicator to this rule's test flag value.
    • Determine the next rule to execute.
      • If the opcode has its goto flag set, its parameter value specifies the number of the next rule.
      • Opcodes which don't have their goto flags set either determine the next rule in special ways (Return), or they terminate execution (Ignore, Fail, Count, CountPkt).
    • Perform the action.

The PME maintains two 'history' data structures ๐Ÿ“š. The first, the 'return' stack, simply records the index (i.e. 1-origin rule number) of each Gosub rule as it is executed, and Return rules pop their Gosub rule index. The second, the 'pattern' queue, is used to save information for later use in building a flow key. A flow key is built by zeroing all its attribute values, then copying attribute and mask information from the pattern stack in the order it was enqueued.

The opcodes are:

      opcode         goto    test

   1  Ignore           0       -
   2  Fail             0       -
   3  Count            0       -
   4  CountPkt         0       -
   5  Return           0       0
   6  Gosub            1       1
   7  GosubAct         1       0
   8  Assign           1       1
   9  AssignAct        1       0
  10  Goto             1       1
  11  GotoAct          1       0
  12  PushRuleTo       1       1
  13  PushRuleToAct    1       0
  14  PushPktTo        1       1
  15  PushPktToAct     1       0

And here's what each one actually does ๐Ÿ”ฅ:

  • Ignore: Stop matching, and return from the match() function indicating that the packet is to be ignored.
  • Fail: Stop matching, and return from the match() function indicating failure.
  • Count: Stop matching. Save this rule's attribute name, mask and value in the PME's pattern queue, then construct a flow key for the flow to which this packet belongs. Return from the match() function indicating success. The meter will use the flow key to locate the flow record for this packet's flow.
  • CountPkt: As for Count, except that the masked value from the packet is saved in the PME's pattern queue instead of the rule's value.
  • Gosub: Call a rule-matching subroutine. Push the current rule number on the PME's return stack, set the test indicator, then goto the specified rule.
  • GosubAct: Same as Gosub, except that the test indicator is cleared before going to the specified rule.
  • Return: Return from a rule-matching subroutine. Pop the number of the calling gosub rule from the PME's 'return' stack and add this rule's parameter value to it to determine the 'target' rule. Clear the test indicator, then goto the target rule.

A subroutine call looks like a Gosub rule followed by a small group of following rules ๐ŸŒธ. Since a Return action clears the test flag, the action of one of these 'following' rules will be executed. This lets the subroutine return a result, on top of any info it saved in the PME's pattern queue.

  • Assign: Set the attribute specified in this rule to the value specified in this rule. Set the test indicator, then goto the specified rule.
  • AssignAct: Same as Assign, except that the test indicator is cleared before going to the specified rule.
  • Goto: Set the test indicator, then goto the specified rule.
  • GotoAct: Clear the test indicator, then goto the specified rule.
  • PushRuleTo: Save this rule's attribute name, mask and value in the PME's pattern queue. Set the test indicator, then goto the specified rule.
  • PushRuleToAct: Same as PushRuleTo, except that the test indicator is cleared before going to the specified rule.

PushRuleTo actions can be used to save the value and mask used in a test, or (if the test is not performed) to save an arbitrary value and mask ๐Ÿฆ‹.

  • PushPktTo: Save this rule's attribute name and mask, together with the masked value from the packet, in the PME's pattern queue. SET the test indicator, then goto the specified rule.
  • PushPktToAct: Same as PushPktTo, except that the test indicator is cleared before going to the specified rule.

PushPktTo actions can be used to save a value from the packet using a specified mask. The test in PushPktTo rules will almost never be executed ๐Ÿ™ˆ.

As well as the attributes that apply directly to packets (such as SourcePeerAddress, DestTransAddress, etc.), the PME implements several further attributes. These are:

  • Null: Tests performed on the Null attribute always succeed.
  • v1 .. v5: v1, v2, v3, v4 and v5 are 'meter variables'. They provide a way to pass parameters into rule-matching subroutines. Each may hold the name of a normal attribute, and its value is set by an Assign action. When a meter variable appears as the attribute of a rule, its value specifies the actual attribute to be tested. For example, if v1 had been assigned SourcePeerAddress as its value, a rule with v1 as its attribute would actually test SourcePeerAddress. ๐Ÿงš
  • SourceClass, DestClass, FlowClass, SourceKind, DestKind, FlowKind: These six attributes may be set by executing PushRuleto actions. They allow the PME to save (in flow records) information which has been built up during matching. Since their values are only defined when matching is complete (and the flow key is built), their values may not be tested in rules ๐Ÿ’€.

4.5. Maintaining the Flow Table ๐Ÿ—‚๏ธ๐Ÿ’–

The flow table may be thought of as a 1-origin array of flow records. (A particular implementation may, of course, use whatever data structure is most suitable.) When the meter starts up there are no known flows, and all the flow records are in the 'inactive' state ๐Ÿ˜ด.

Each time a packet is seen for a flow that is not in the current flow set, a flow record is set up for it, and the state of that record is 'current.' When selecting a record for the new flow, the meter searches the flow table for an 'inactive' record. There is no particular significance in the ordering of records within the table ๐ŸŒˆ.

Flow data may be collected by a 'meter reader' at any time. There is no requirement for collections to be synchronized. The reader can collect the data in any suitable manner. For example, it could upload a copy of the whole flow table using a file transfer protocol, or it could read the records in the current flow set row by row using a suitable data transfer protocol ๐Ÿ“ฅ.

The meter keeps information about collections. In particular, it maintains a LastCollectTime variable, which remembers the time the last collection was made. A second variable, InactivityTime, specifies the minimum time the meter will wait before considering that a flow is idle โฐ.

The meter must recover records used for idle flows, if only to prevent it running out of flow records. Recovered flow records are returned to the 'inactive' state. A variety of recovery strategies are possible, including the following ๐Ÿ‘‘:

One possible recovery strategy is to recover idle flow records as soon as possible after their data has been collected. To implement this, the meter could run a background process which scans the flow table looking for 'current' flows whose 'last packet' time is earlier than the meter's LastCollectTime. This would be suitable when one is interested in measuring flow lifetimes โญ.

Another recovery strategy is to leave idle flows alone for as long as possible. This would be suitable if one was only interested in measuring total traffic volumes. It could be implemented by having the meter search for collected idle flows only when it runs out of 'inactive' flow records ๐Ÿ“.

One further factor a meter should consider before recovering a flow is the number of meter readers which have collected the flow's data. If there are multiple meter readers operating, network Operations personnel should be able to specify the minimum number of meters (or perhaps a specific list of meters) which should collect a flow's data before its memory can be recovered. This issue will be further developed in the future ๐Ÿ”ฎ.


4.6. Handling Increasing Traffic Levels ๐Ÿ“ˆ๐Ÿซถ

Under normal conditions, the meter reader specifies which set of usage records it wants to collect, and the meter provides them ๐Ÿ’œ.

If memory usage rises above the high-water mark, the meter should switch to a STANDBY RULE SET so as to increase the granularity of flow collection and decrease the rate at which new flows are created ๐Ÿšจ. When the manager, usually as part of a regular poll, becomes aware that the meter is using its standby rule set, it could decrease the interval between collections. The meter should also increase its efforts to recover flow memory, so as to reduce the number of idle flows in memory. When the situation returns to normal, the manager may request the meter to switch back to its normal rule set โœจ.

5. Meter Readers ๐Ÿ“ฌโœจ

okay so a meter (think a router ๐Ÿ–ฅ๏ธ) piles up usage data for as long as its memory allows. Then meter readers come by at regular reporting intervals to grab it, on whatever schedule the manager has specified. ๐Ÿ’… Everything they collect gets saved to a disk file called a FLOW DATA FILE ๐Ÿ’พ, which is built out of a bunch of USAGE RECORDS.

The next sections cover what usage records and flow data files look like. heads up tho, the architecture does not pin down the details of these at this stage ๐Ÿ™ˆ. A common format for them would be a seriously worthwhile thing to build later.

5.1. Identifying Flows in Flow Records

Once a packet has been classified and is ready to be counted, there has to be a matching flow data record already in the flow table. If there isn't one, it gets created ๐Ÿง. The flow record is super flexible, so any identification attributes that aren't needed can just be left out. Which attributes go in, and what values they get, is decided by the current rule set.

Here's the lowkey important bit ๐Ÿ”‘: the combination of start time, rule set id and subscript (row number in the flow table) gives you a unique flow identifier, no matter what the other attributes are.

The current rule set can also add extra info, like a computed attribute value such as FlowKind, into the attribute section of the usage record. So if a particular flow is matched by the rule set, its flow record should be marked not only with the qualifying identification attributes, but also with that extra info ๐ŸŽ€. Since several flows can each carry the same FlowKind value, the resulting usage records can be used in post-processing, or between the meter reader and the meter as a criterion for collection. it's giving organisation ๐Ÿ’œ.

5.2. Usage Records, Flow Data Files

The collected usage data is stored in flow data files on the meter reader, with one file for each meter ๐Ÿ—‚๏ธ. Besides the measured usage data, flow data files must contain information that uniquely identifies the meter the data came from ๐Ÿชช.

A USAGE RECORD contains the descriptions of, and values for, one or more flows. Quantities are counted as number of packets and number of bytes per flow ๐Ÿ”ข. Each usage record contains the entity identifier of the meter (a network address), a timestamp, and a list of reported flows (FLOW DATA RECORDS). A meter reader builds up a file of usage records by regularly collecting flow data from a meter, using that data to make usage records, and concatenating them onto the tail of a file. That file is called a FLOW DATA FILE ๐Ÿฆ‹.

A usage record contains the following information in some form:

+-------------------------------------------------------------------+
|    RECORD IDENTIFIERS:                                            |
|      Meter Id (& digital signature if required)                   |
|      Timestamp                                                    |
|      Collection Rules ID                                          |
+-------------------------------------------------------------------+
|    FLOW IDENTIFIERS:            |    COUNTERS                     |
|      Address List               |       Packet Count              |
|      Subscriber ID (Optional)   |       Byte Count                |
|      Attributes (Optional)      |    Flow Start/Stop Time         |
+-------------------------------------------------------------------+

5.3. Meter to Meter Reader: Usage Record Transmission

Usage records are literally the reason this whole system exists ๐Ÿ’–. So the accuracy, reliability, and security of transmission are the primary concerns of the meter/meter reader exchange ๐Ÿ”. Errors can happen on networks, and Internet packets may get dropped, so some mechanism is needed to make sure the usage info arrives intact.

Flow data moves from meter to meter reader through a series of protocol exchanges between them ๐Ÿ”. This can happen in various ways, like moving individual attribute values, complete flows, or the entire flow table (i.e. all the active flows). One possible method is to use SNMP ๐Ÿ›ฐ๏ธ; the 'Traffic Flow Measurement: Meter MIB' document [4] gives the details. Note that this is simply one example, because the transfer of flow data from meter to meter reader is not specified in this document.

The reliability of the data transfer method under light, normal, and extreme network loads should be understood before you pick among collection methods ๐Ÿง.

In normal operation the meter runs a rule file that provides the required degree of flow reporting granularity. The meter reader(s) collect the flow data often enough to let the meter's garbage collection mechanism keep memory usage stable ๐Ÿงน.

In the worst case, traffic may climb to the point where the meter is in danger of running completely out of flow memory ๐Ÿ˜ญ. The meter implementor has to decide how to handle this. For example, they could switch to a default (extremely coarse granularity) rule set, send a trap to the manager, or try dumping flow data to the meter reader.

Users of the Traffic Flow Measurement system should analyse their requirements carefully. They need to decide for themselves whether it matters more to collect flow data at normal granularity (raising the collection frequency as needed to keep up with traffic volumes), or to accept flow data at a coarser granularity. Similarly, it may be fine to lose flow data for a short time, in return for making sure the meter keeps running properly and isn't overwhelmed by rising traffic levels ๐Ÿซถ.

6. Managers ๐Ÿ‘‘

A manager configures meters and controls meter readers. It does this through the interactions described below ๐Ÿ’….

6.1. Between Manager and Meter: Control Functions

  • DOWNLOAD RULE SET: A meter may hold an array of rule sets. One of these, the 'default' rule set, is built into the meter and cannot be changed. The others must be downloaded by the manager ๐Ÿ“ฅ. A manager may use any suitable protocol exchange to do this, for example an FTP file transfer or a series of SNMP SETs, one for each row of the rule set.
  • SWITCH TO SPECIFIED RULE SET: Once the rule sets have been downloaded, the manager must tell the meter which rule set it is to actually run (i.e. which is to be the current rule set), and which is to be the standby rule set ๐Ÿ”€.
  • SET HIGH WATER MARK: A percentage value that the meter interprets to know when to switch to its standby rule set. This increases the granularity of the flows and conserves the meter's flow memory ๐Ÿง . Once that has happened, the manager may also change the polling frequency or the meter's control parameters, so the meter can recover memory from idle flows faster ๐Ÿƒโ€โ™€๏ธ.

If the high traffic levels persist, the meter's normal rule set may have to be rewritten to permanently reduce the reporting granularity ๐Ÿ“‰.

  • SET FLOW TERMINATION PARAMETERS: The meter should have the good sense, in situations where lack of resources may cause data loss, to purge flow records from its tables ๐Ÿงฝ. Such records may include:
    • Flows that have already been reported to at least one meter reader, and show no activity since the last report,
    • Oldest flows, or
    • Flows with the smallest number of unreported packets.
  • SET INACTIVITY TIMEOUT: This is a time in seconds since the last packet was seen for a flow โฑ๏ธ. Flow records may be reclaimed if they have been idle for at least this amount of time, and have been collected in accordance with the current collection criteria.

6.2. Between Manager and Meter Reader: Control Functions

Lots of parameters have to be set for traffic flow measurement to work properly ๐ŸŽ›๏ธ. Viable settings can change as network traffic characteristics change, so dynamic network management is preferred over static meter configurations ๐ŸŒŠ. A lot of these operations come down to space tradeoffs. If memory at the meter runs out, either the reporting interval has to go down or a coarser granularity of aggregation has to be used, so more data fits into less space ๐Ÿ“ฆ.

Increasing the reporting interval effectively stores data in the meter. Usage data in transit is limited by the effective bandwidth of the virtual link between the meter and the meter reader. These limited network resources are usually also used to carry user data (the whole purpose of the network), so the level of traffic flow measurement traffic should be kept to an affordable fraction of the bandwidth ๐Ÿ’ธ. ("Affordable" is a policy decision made by the network Operations personnel.) At any rate, it must be understood that the operations below do not represent the setting of independent variables. On the contrary, each value set has a direct and measurable effect on the behaviour of the other variables ๐Ÿ”—.

Network management operations follow:

  • MANAGER and METER READER IDENTIFICATION: The manager should make sure meters report to the correct set of collection stations, and take steps to prevent unauthorised access to usage information ๐Ÿ”’. The collection stations identified should be prepared to poll if necessary, and to accept data from the appropriate meters. Alternate collection stations may be identified in case both the primary manager and the primary collection station are unavailable. Similarly, alternate managers may be identified ๐Ÿง‘โ€๐Ÿคโ€๐Ÿง‘.
  • REPORTING INTERVAL CONTROL: The usual reporting interval should be selected to cope with normal traffic patterns. However, a meter may still run out of memory during traffic spikes even with a correctly set reporting interval ๐Ÿ“ˆ. So some mechanism must be available for the meter to tell the manager it is in danger of exhausting its memory (by declaring a 'high water' condition). The manager can then arbitrate, by decreasing the polling interval, letting nature take its course, or by telling the meter to ask for help sooner next time ๐Ÿ™.
  • GRANULARITY CONTROL: Granularity control is a catch-all for all the parameters that can be tuned and traded off to optimise the system's ability to reliably measure and store information on all the traffic (or as close to all the traffic as an administration requires) ๐ŸŽฏ. Granularity:
    • Controls flow-id granularities for each interface, and
    • Determines the number of buckets into which user traffic will be lumped together ๐Ÿชฃ.

Since granularity is controlled by the meter's current rule set, the manager can only change it by requesting that the meter switch to a different rule set. The new rule set could be downloaded when required, or it could have been downloaded as part of the meter's initial configuration ๐Ÿง.

  • FLOW LIFETIME CONTROL: Flow termination parameters include timeout parameters for obsoleting inactive flows and removing them from tables, as well as maximum flow lifetimes โณ. This is intertwined with reporting interval and granularity, so it must be set in accordance with the other parameters ๐Ÿงถ.

6.3 Exception Conditions โœจ

okay so exception conditions are a whole thing and they must be handled, especially when the meter runs out of buffer space ๐Ÿ˜ญ bestie, the tea is that packets can only be counted in one flow at any given time (so nothing gets counted twice ๐Ÿ’…), which means if you toss records you lose information. here's how we deal with it:

  • METER OUTAGES: if a meter outage is coming (controlled crashes, etc.) the meter could send a trap to the manager. then the manager could ask one or more meter readers to grab the usage record from the meter ๐Ÿงš

after an uncontrolled outage like a power failure, the meter could send a trap to the manager saying it restarted. then the manager could download the meter's correct rule set and tell the meter reader(s) that the meter is back up โœจ or, alternatively, the meter reader might notice from its regular poll that a meter failed and restarted. then it could tell the manager directly, instead of waiting on a trap from the meter ๐Ÿฆ‹

  • METER READER OUTAGES: if the collection system is down or isolated, the meter should try to let the manager know it can't reach the collection system ๐Ÿ“ž the usage data is safe though! it lives in the flows' rolling counters, so it can be recovered once the meter reader is restarted ๐Ÿซถ
  • MANAGER OUTAGES: if the manager fails for any reason, the meter should keep measuring and the meter reader(s) should keep gathering usage records. the show goes on ๐Ÿ’–
  • BUFFER PROBLEMS: the network manager might realise there's a 'low memory' condition in the meter ๐Ÿฅบ this can usually be traced back to how these controls interact:
    • The reporting interval is too infrequent,
    • The reporting granularity is too fine, or
    • The throughput/bandwidth of circuits carrying the usage data is too low.

the manager may change any of these parameters when the meter (or meter reader's) begs for help ๐Ÿ™

6.4 Standard Rule Sets ๐Ÿ“

the rule table is super flexible, but ngl it can get really complex ๐Ÿฅด so it's helpful to make some rule sets for the common stuff:

  • PROTOCOL TYPE: the meter records packets by protocol type. this will be the default rule table for Traffic Flow Meters ๐ŸŽ€
  • ADJACENT SYSTEMS: the meter records packets by the MAC address of the Adjacent Systems (neighbouring originator or next-hop). (variants on this table are "report source" or "report sink" only.) this strategy might be used by a regional or backbone network that wants to know how much aggregate traffic flows to or from its subscriber networks ๐ŸŒˆ
  • END SYSTEMS: the meter records packets by the IP address pair contained in the packet. (variants on this table are "report source" or "report sink" only.) this strategy might be used by an End System network to get detailed host traffic matrix usage data ๐Ÿ‘‘
  • TRANSPORT TYPE: the meter records packets by transport address. for IP packets this gives usage info for the various IP services ๐Ÿ’œ
  • HYBRID SYSTEMS: combinations of the above, e.g. for one interface report End Systems, and for another interface report Adjacent Systems. this strategy might be used by an enterprise network that wants detail about local usage and an aggregate count for the shared regional network ๐Ÿซถ

7 APPENDICES ๐ŸŽ€

7.1 Appendix A: Network Characterisation ๐ŸŒธ

internet users have wildly diverse requirements, bestie ๐Ÿฆ‹ networks differ in size, speed, throughput, and processing power (among other things), and there's a whole range of traffic flow measurement capabilities and requirements. for traffic flow measurement purposes, the Internet can be viewed as a continuum that changes character as traffic passes through these representative levels:

        International                    |
        Backbones/National        ---------------
                                 /              \
        Regional/MidLevel     ----------   ----------
                             /   \     \  /   /     \
        Stub/Enterprise     ---   ---   ---   ----   ----
                            |||   |||   |||   ||||   ||||
        End-Systems/Hosts   xxx   xxx   xxx   xxxx   xxxx

note that mesh architectures can also be built out of these components, and these are just descriptive terms ๐Ÿ’… a single network can cover any or all of the descriptions below, although some networks can clearly be identified as a single type.

BACKBONE networks are typically bulk carriers that connect other networks. individual hosts (except for network management devices and backbone service hosts) typically aren't directly connected to backbones ๐ŸŒˆ

REGIONAL networks are closely related to backbones and differ only in size, the number of networks connected via each port, and geographical coverage. regionals may have directly connected hosts, acting as hybrid backbone/stub networks. a regional network is a SUBSCRIBER to the backbone ๐Ÿงš

STUB/ENTERPRISE networks connect hosts and local area networks. STUB/ENTERPRISE networks are SUBSCRIBERS to regional and backbone networks โœจ

END SYSTEMS, colloquially HOSTS, are SUBSCRIBERS to any of the above networks ๐Ÿ’–

providing a uniform identification of the SUBSCRIBER at a finer granularity than end-system (e.g. user/account) is beyond the scope of the current architecture ๐Ÿ™ˆ but an optional attribute in the traffic flow measurement record may carry system-specific "accountable (billable) party" labels, so meters can implement proprietary or non-standard schemes for attributing network traffic to responsible parties ๐Ÿ“

here are the initial recommended traffic flow measurement conventions, organised by these Internet building blocks. it's important to understand what complexity reporting adds at each network level. the hierarchy was described top-down in the previous section, but reporting requirements are easier to address bottom-up ๐Ÿซถ

        End-Systems
        Stub Networks
        Enterprise Networks
        Regional Networks
        Backbone Networks

END-SYSTEMS are currently responsible for allocating network usage to end-users, if that capability is wanted ๐Ÿ’… from the Internet Protocol perspective, end-systems are the finest granularity that can be identified without protocol modifications. even if a meter broke protocol boundaries and tracked higher-level protocols, not all packets could be correctly allocated by user, and the definition of user varies too much from operating system to operating system (e.g. how to trace network usage back to users from shared processes) ๐Ÿคฏ

STUB and ENTERPRISE networks will usually collect traffic data either by end-system network address or by network address pair if detailed reporting is needed in the local area network ๐ŸŽ€ if no local reporting is needed, they may record usage in the exit router to track external traffic only. (these are the only networks that routinely use attributes to report at granularities finer than end-system or intermediate-system network address ๐Ÿ‘‘)

REGIONAL networks are intermediate networks ๐ŸŒธ in some cases, subscribers will be enterprise networks, and then the intermediate system network address is enough to identify the regional's immediate subscriber. in other cases, individual hosts or a disjoint group of hosts may be a subscriber, so end-system network address pairs need to be tracked for those subscribers. when the source may be an aggregate entity (such as a network, or an adjacent router representing traffic from a world of hosts beyond) and the destination is a singular entity (or vice versa), the meter is said to be operating as a HYBRID system ๐ŸŒˆ

at the regional level, if the overhead is tolerable, it may be advantageous to report usage both by intermediate system network address (e.g. adjacent router address) and by end-system network address or end-system network address pair โœจ

BACKBONE networks are the highest-level networks, operating at the highest link speeds and traffic levels ๐Ÿš€ the high volume of traffic will in most cases rule out detailed traffic flow measurement, so backbone networks will usually account for traffic by adjacent routers' network addresses ๐Ÿ’œ

7.3 Appendix C: List of Defined Flow Attributes ๐Ÿ’–

this appendix is a checklist of the attributes defined so far ๐Ÿ“‹ more will be added later as the Traffic Measurement Architecture develops further ๐Ÿงš

   0  Null
   1  Flow Subscript                Integer    Flow table info
   2  Flow Status                   Integer

   4  Source Interface              Integer    Source Address
   5  Source Adjacent Type          Integer
   6  Source Adjacent Address       String
   7  Source Adjacent Mask          String
   8  Source Peer Type              Integer
   9  Source Peer Address           String
  10  Source Peer Mask              String
  11  Source Trans Type             Integer
  12  Source Trans Address          String
  13  Source Trans Mask             String

  14  Destination Interface         Integer    Destination Address
  15  Destination Adjacent Type     Integer
  16  Destination Adjacent Address  String
  17  Destination AdjacentMask      String
  18  Destination PeerType          Integer
  19  Destination PeerAddress       String
  20  Destination PeerMask          String
  21  Destination TransType         Integer
  22  Destination TransAddress      String
  23  Destination TransMask         String

  24  Packet Scale Factor           Integer    'Other' attributes
  25  Byte Scale Factor             Integer
  26  Rule Set Number               Integer
  27  Forward Bytes                 Counter    Source-to-Dest counters
  28  Forward Packets               Counter
  29  Reverse Bytes                 Counter    Dest-to-Source counters
  30  Reverse Packets               Counter
  31  First Time                    TimeTicks  Activity times
  32  Last Active Time              TimeTicks
  33  Source Subscriber ID          String     Session attributes
  34  Destination Subscriber ID     String
  35  Session ID                    String

  36  Source Class                  Integer    'Computed' attributes
  37  Destination Class             Integer
  38  Flow Class                    Integer
  39  Source Kind                   Integer
  40  Destination Kind              Integer
  41  Flow Kind                     Integer

  51  V1                            Integer    Meter variables
  52  V2                            Integer
  53  V3                            Integer
  54  V4                            Integer
  55  V5                            Integer

7.4 Appendix D: List of Meter Control Variables ๐Ÿฆ„

      Current Rule Set Number       Integer
      Standby Rule Set Number       Integer
      High Water Mark               Percentage
      Flood Mark                    Percentage
      Inactivity Timeout (seconds)  Integer
      Last Collect Time             TimeTicks

8. Acknowledgments โœจ

This document was first put together under the IETF's Internet Accounting Working Group, with help from the SNMP, RMON and SAAG working groups ๐Ÿซถ. This version writes down the implementation work the Internet Accounting Working Group did, and it's meant to be a starting point for the Realtime Traffic Flow Measurement Working Group ๐ŸŒธ. Huge thanks to Stephen Stibler (IBM Research) for his patient and careful comments while this memo was being prepared ๐Ÿ’–.

9. References ๐Ÿ“š

[1] Mills, C., Hirsch, G. and G. Ruth, "Internet Accounting Background", RFC 1272, Bolt Beranek and Newman Inc., Meridian Technology Corporation, November 1991.

[2] International Standards Organisation (ISO), "Management Framework," Part 4 of Information Processing Systems Open Systems Interconnection Basic Reference Model, ISO 7498-4, 1994.

[3] IEEE 802.3/ISO 8802-3 Information Processing Systems - Local Area Networks - Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications, 2nd edition, September 21, 1990.

[4] Brownlee, N., "Traffic Flow Measurement: Meter MIB", RFC 2064, The University of Auckland, January 1997.

10. Security Considerations ๐Ÿ”

Okay bestie, real talk, this one's a bit of a plot twist ๐Ÿ˜ญ. Security issues are not discussed in detail in this document. Instead, the meter's management and collection protocols are the ones on the hook for providing sufficient data integrity and confidentiality ๐Ÿ’€. So if you're building or running this stuff, the protection has to come from those protocols, not from the meter spec itself ๐Ÿ›ก๏ธโœจ.

11. Authors' Addresses ๐Ÿฆ‹

Here's who wrote this, with their contact details, so you can reach out if you're confused ๐ŸŒˆ.

Nevil Brownlee Information Technology Systems & Services The University of Auckland

Phone: +64 9 373 7599 x8941
EMail: n.brownlee @auckland.ac.nz

Cyndi Mills BBN Systems and Technologies

Phone: +1 617 873 4143
EMail: cmills@bbn.com

Greg Ruth GTE Laboratories, Inc

Phone: +1 617 466 2448
EMail: gruth@gte.com

And that's the whole RFC, bestie! ๐ŸŽ€๐Ÿ’…๐Ÿ‘‘