RFC 1493
Definitions of Managed Objects for Bridges
RFC 1493: Definitions of Managed Objects for Bridges πΈ
okay bestie, this one is a whole author squad π E. Decker from cisco Systems, Inc., P. Langille and A. Rijsinghani from Digital Equipment Corporation, and K. McCloghrie from Hughes LAN Systems, Inc. It's from the Network Working Group, dated July 1993. It obsoletes RFC 1286, so 1286 is retired and this is the newer version. It's an IAB standards track protocol, which is the official "this is a real standard" category π₯
Status of this Memo
This is an IAB standards track protocol for the Internet community, and it's looking for discussion and suggestions for improvements π£οΈ For the standardization state and status, check the current edition of the "IAB Official Protocol Standards". Distribution of this memo is unlimited π¦
Abstract
This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in TCP/IP based internets π It's all about objects for managing MAC bridges, based on the IEEE 802.1D-1990 standard, between Local Area Network (LAN) segments. It makes room for transparent bridging, and it's also set up so these objects can apply to bridges connected by subnetworks other than LAN segments β¨
Table of Contents
1. The Network Management Framework ...................... 2
2. Objects ............................................... 2
2.1 Format of Definitions ................................ 3
3. Overview .............................................. 3
3.1 Structure of MIB ..................................... 3
3.1.1 The dot1dBase Group ................................ 6
3.1.2 The dot1dStp Group ................................. 6
3.1.3 The dot1dSr Group .................................. 6
3.1.4 The dot1dTp Group .................................. 6
3.1.5 The dot1dStatic Group .............................. 6
3.2 Relationship to Other MIBs ........................... 6
3.2.1 Relationship to the 'system' group ................. 6
3.2.2 Relationship to the 'interfaces' group ............. 7
3.3 Textual Conventions .................................. 8
4. Changes from RFC 1286 ................................. 8
5. Definitions ........................................... 9
5.1 Groups in the Bridge MIB ............................. 11
5.2 The dot1dBase Group Definitions ...................... 11
5.3 The dot1dStp Group Definitions ....................... 14
5.4 The dot1dTp Group Definitions ........................ 22
5.5 The dot1dStatic Group Definitions .................... 28
5.6 Traps for use by Bridges ............................. 31
6. Acknowledgments ....................................... 31
7. References ............................................ 33
8. Security Considerations ............................... 33
9. Authors' Addresses .................................... 34
1. The Network Management Framework β¨
okay so the Internet-standard Network Management Framework has three parts π§©
STD16/RFC 1155defines the SMI, the mechanisms used for describing and naming objects for management.STD16/RFC 1212adds a more concise description mechanism, and it's totally consistent with the SMI.RFC 1156defines MIB-I, the core set of managed objects for the Internet suite of protocols.STD17/RFC 1213defines MIB-II, which is MIB-I evolved based on implementation experience and new operational requirements.STD15/RFC 1157defines SNMP, the protocol used for network access to managed objects.
The Framework also lets new objects be defined for experimentation and evaluation π§ͺ
2. Objects ποΈ
Managed objects are accessed through a virtual information store called the Management Information Base, or MIB. Objects in the MIB are defined using the subset of Abstract Syntax Notation One (ASN.1) [7] that the SMI defines. Each object is named by an OBJECT IDENTIFIER, an administratively assigned name that specifies an object type. The object type together with an object instance uniquely identifies one specific instantiation of the object. For human convenience, a textual string called the descriptor is often used to refer to the object type too π
2.1. Format of Definitions
Section 5 contains the specification of all object types in this MIB module. The object types are defined using the conventions in the SMI, as amended by the extensions specified in [9,10] π
3. Overview π
A bridge is a super common device in lots of networks. It connects Local Area Network segments below the network layer.
There are two major bridging modes: transparent and source route. Transparent bridging is defined in the draft IEEE 802.1d specification [11]. This memo defines the objects needed to manage a bridging entity running in transparent mode, plus some objects that apply to all types of bridges π¦
To stay consistent with IAB directives and good engineering practice, they really tried to keep this MIB as simple as possible π«Ά Every object proposed for inclusion was judged by these criteria:
- Start with a small set of essential objects, and only add more as they're needed.
- Objects need to be essential for either fault or configuration management.
- Look for evidence of current use and/or utility.
- Limit the total number of objects.
- Leave out objects that can be simply derived from others in this or other MIBs.
- Don't heavily instrument critical sections. The guideline was one counter per critical section per layer.
3.1. Structure of MIB π§
Okay so the objects are sorted into groups, and each group is a set of related objects. Here's the overall layout, with the matching IEEE 802.1d management object name included where there is one π
Bridge MIB Name IEEE 802.1d Name
dot1dBridge
dot1dBase
BridgeAddress Bridge.BridgeAddress
NumPorts Bridge.NumberOfPorts
Type
PortTable
Port BridgePort.PortNumber
IfIndex
Circuit
DelayExceededDiscards .DiscardTransitDelay
MtuExceededDiscards .DiscardOnError
dot1dStp
ProtocolSpecification
Priority SpanningTreeProtocol
.BridgePriority
TimeSinceTopologyChange .TimeSinceTopologyChange
TopChanges .TopologyChangeCount
DesignatedRoot .DesignatedRoot
RootCost .RootCost
RootPort .RootPort
MaxAge .MaxAge
HelloTime .HelloTime
HoldTime .HoldTime
ForwardDelay .ForwardDelay
BridgeMaxAge .BridgeMaxAge
BridgeHelloTime .BridgeHelloTime
BridgeForwardDelay .BridgeForwardDelay
PortTable
Port SpanningTreeProtocolPort
.PortNumber
Priority .PortPriority
State .SpanningTreeState
Enable
PathCost .PortPathCost
DesignatedRoot .DesignatedRoot
DesignatedCost .DesignatedCost
DesignatedBridge .DesignatedBridge
DesignatedPort .DesignatedPort
ForwardTransitions
dot1dTp
LearnedEntryDiscards BridgeFilter.DatabaseSize
.NumDynamic,NumStatic
AgingTime BridgeFilter.AgingTime
FdbTable
Address
Port
Status
PortTable
Port
MaxInfo
InFrames BridgePort.FramesReceived
OutFrames .ForwardOutbound
InDiscards .DiscardInbound
dot1dStatic
StaticTable
Address
ReceivePort
AllowedToGoTo
Status
Some IEEE 802.1d management objects were left out of the Bridge MIB, and here's why π
IEEE 802.1d Object Disposition
Bridge.BridgeName Same as sysDescr (MIB II)
Bridge.BridgeUpTime Same as sysUpTime (MIB II)
Bridge.PortAddresses Same as ifPhysAddress (MIB II)
BridgePort.PortName Same as ifDescr (MIB II)
BridgePort.PortType Same as ifType (MIB II)
BridgePort.RoutingType Derivable from the implemented
groups
SpanningTreeProtocol
.BridgeIdentifier Combination of dot1dStpPriority
and dot1dBaseBridgeAddress
.TopologyChange Since this is transitory, it
is not considered useful.
SpanningTreeProtocolPort
.Uptime Same as ifLastChange (MIB II)
.PortIdentifier Combination of dot1dStpPort
and dot1dStpPortPriority
.TopologyChangeAcknowledged Since this is transitory, it
is not considered useful.
.DiscardLackOfBuffers Redundant
Transmission Priority These objects are not required
as per the Pics Proforma and
not considered useful.
.TransmissionPriorityName
.OutboundUserPriority
.OutboundAccessPriority
3.1.1. The dot1dBase Group π§±
This one's the mandatory group, and it holds the objects that apply to all types of bridges. No skipping it!
3.1.2. The dot1dStp Group π³
This group holds the objects that show the bridge's state with respect to the Spanning Tree Protocol. If a node doesn't implement the Spanning Tree Protocol, then this group won't be implemented either β¨
3.1.3. The dot1dSr Group β¨
This group holds the objects that describe the entity's state for source route bridging πΈ. If source routing isn't supported, this group won't be implemented, bestie. It only applies to source route bridges and SRT bridges π . Source route bridging gets its own separate document, so this one doesn't cover it.
3.1.4. The dot1dTp Group π¦
This group has the objects that describe the entity's state for transparent bridging π. If transparent bridging isn't supported, this group won't be implemented. It applies to transparent bridges and SRT bridges π«Ά.
3.1.5. The dot1dStatic Group π
This group holds the objects that describe the entity's state for destination-address filtering π. If destination-address filtering isn't supported, this group won't be implemented either. It applies to any bridge that does destination-address filtering, so it's a whole vibe π§.
3.2. Relationship to Other MIBs π
Some IEEE 802.1d management objects aren't in this MIB, and that's on purpose π. They overlap with objects in other MIBs that a bridge implementing this MIB also uses. Specifically, it's assumed that a bridge implementing this MIB will also implement (at least) the "system" group and the "interfaces" group from MIB-II [6] β¨.
3.2.1. Relationship to the 'system' group πΈ
In MIB-II, the "system" group is mandatory for all systems. That means every managed entity has one instance of each object in the "system" group π. Those objects apply to the entity as a whole, whether its only job is bridging or bridging is just part of what it does π.
3.2.2. Relationship to the 'interfaces' group π¦
In MIB-II, the "interfaces" group is mandatory for all systems too. It holds info about an entity's interfaces, and each interface is thought of as attached to a "subnetwork" π₯. (Careful, this isn't the same as "subnet," which means an addressing partition used in the Internet protocol suite π.) This memo uses "segment" for that subnetwork, and it could be an Ethernet segment, a "ring," a WAN link, or even an X.25 virtual circuit π.
The Bridge MIB has the idea of ports on a bridge built in π§. Each port is tied to one interface from the "interfaces" group. Usually each port has its own, different interface π . But sometimes several ports share the same interface. For example, several ports could each match one X.25 virtual circuit, all on the same interface π.
Each port has its own port number to identify it π. A port number doesn't have to match an interface number. In the simple case, though, the port number is the same value as its interface's interface number β¨. Port numbers fall in the range (1..dot1dBaseNumPorts) π.
Some entities do other things besides bridging, like sending and receiving data on their interfaces π«Ά. In those cases, only part of the data on an interface belongs to the bridging job πΈ. That part is split by protocol: some protocols get bridged, and others don't π . If an entity only bridges, every protocol counts as bridged π. But if an entity routes IP datagrams and only bridges the other protocols, only the non-IP data counts as bridged π.
So this Bridge MIB, and especially its counters, only applies to the slice of data on an entity's interfaces that gets sent or received for a bridged protocol π¦. All of that data goes through the bridge's ports π.
3.3. Textual Conventions π
The datatypes MacAddress, BridgeId and Timeout are used as textual conventions in this document π. These conventions have NO effect on either the syntax or the semantics of any managed object π. Objects defined with them are always encoded using the rules for their primitive type π§. So no changes to the SMI or the SNMP are needed to support them, since they're just there to make life easier for readers π«Ά.
4. Changes from RFC 1286 β¨
Here's the tea on what changed since RFC 1286 π:
- (1) Updated all text to remove references to source route bridging where they didn't apply πΈ. The SR MIB is getting its own separate document π .
- (2) Removed dot1dSrPortTable π, but kept the OID definition of dot1dSr π¦.
- (3) Changed every reference to "draft P802.1d/D9" to "IEEE 802.1D-1990" π.
- (4) Updated the bibliography πβ¨.
- (5) Added some clarification to the description of dot1dPortPathCost π.
- (6) Put the recommended default in the description of dot1dStaticAllowedToGoTo π«Ά.
- (7) Put the recommended default in the description of dot1dStaticStatus π.
- (8) Put the recommended default in the description of dot1dTpAgingTime, and specified the range
(10..1000000)π₯. - (9) Updated all port number syntaxes used as an index to use the range
(1..65535)π§. - (10) Updated the definitions of dot1dTpPortInFrames and dot1dTpPortOutFrames π.
- (11) Added text to the traps saying they're optional π.
- (12) Clarified the definition of dot1dStpForwardDelay π .
5. Definitions π
Here's the MIB module itself, bestie π¦. Every line stays exactly as written π:
BRIDGE-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter, TimeTicks
FROM RFC1155-SMI
mib-2
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215;
-- All representations of MAC addresses in this MIB Module
-- use, as a textual convention (i.e. this convention does
-- not affect their encoding), the data type:
MacAddress ::= OCTET STRING (SIZE (6)) -- a 6 octet address
-- in the
-- "canonical"
-- order
-- defined by IEEE 802.1a, i.e., as if it were transmitted
-- least significant bit first, even though 802.5 (in
-- contrast to other n802.x protocols) requires MAC
-- addresses to be transmitted most significant bit first.
--
-- 16-bit addresses, if needed, are represented by setting
-- their upper 4 octets to all 0's, i.e., AAFF would be
-- represented as 00000000AAFF.
-- Similarly, all representations of Bridge-Id in this MIB
-- Module use, as a textual convention (i.e. this
-- convention does not affect their encoding), the data
-- type:
BridgeId ::= OCTET STRING (SIZE (8)) -- the
-- Bridge-Identifier
-- as used in the
-- Spanning Tree
-- Protocol to uniquely identify a bridge. Its first two
-- octets (in network byte order) contain a priority
-- value and its last 6 octets contain the MAC address
-- used to refer to a bridge in a unique fashion
-- (typically, the numerically smallest MAC address
-- of all ports on the bridge).
-- Several objects in this MIB module represent values of
-- timers used by the Spanning Tree Protocol. In this
-- MIB, these timers have values in units of hundreths of
-- a second (i.e. 1/100 secs).
-- These timers, when stored in a Spanning Tree Protocol's
-- BPDU, are in units of 1/256 seconds. Note, however,
-- that 802.1D-1990 specifies a settable granularity of
-- no more than 1 second for these timers. To avoid
-- ambiguity, a data type is defined here as a textual
-- convention and all representation of these timers
-- in this MIB module are defined using this data type. An
-- algorithm is also defined for converting between the
-- different units, to ensure a timer's value is not
-- distorted by multiple conversions.
-- The data type is:
Timeout ::= INTEGER -- a STP timer in units of 1/100 seconds
-- To convert a Timeout value into a value in units of
-- 1/256 seconds, the following algorithm should be used:
--
-- b = floor( (n * 256) / 100)
--
-- where:
-- floor = quotient [ignore remainder]
-- n is the value in 1/100 second units
-- b is the value in 1/256 second units
--
-- To convert the value from 1/256 second units back to
-- 1/100 seconds, the following algorithm should be used:
--
-- n = ceiling( (b * 100) / 256)
--
-- where:
-- ceiling = quotient [if remainder is 0], or
-- quotient + 1 [if remainder is non-zero]
-- n is the value in 1/100 second units
-- b is the value in 1/256 second units
--
-- Note: it is important that the arithmetic operations are
-- done in the order specified (i.e., multiply first, divide
-- second).
dot1dBridge OBJECT IDENTIFIER ::= { mib-2 17 }
-- groups in the Bridge MIB
dot1dBase OBJECT IDENTIFIER ::= { dot1dBridge 1 }
dot1dStp OBJECT IDENTIFIER ::= { dot1dBridge 2 }
dot1dSr OBJECT IDENTIFIER ::= { dot1dBridge 3 }
-- separately documented
dot1dTp OBJECT IDENTIFIER ::= { dot1dBridge 4 }
dot1dStatic OBJECT IDENTIFIER ::= { dot1dBridge 5 }
-- the dot1dBase group
-- Implementation of the dot1dBase group is mandatory for all
-- bridges.
dot1dBaseBridgeAddress OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address used by this bridge when it must
be referred to in a unique fashion. It is
recommended that this be the numerically smallest
MAC address of all ports that belong to this
bridge. However it is only required to be unique.
When concatenated with dot1dStpPriority a unique
BridgeIdentifier is formed which is used in the
Spanning Tree Protocol."
REFERENCE
"IEEE 802.1D-1990: Sections 6.4.1.1.3 and 3.12.5"
::= { dot1dBase 1 }
dot1dBaseNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of ports controlled by this bridging
entity."
REFERENCE
"IEEE 802.1D-1990: Section 6.4.1.1.3"
::= { dot1dBase 2 }
dot1dBaseType OBJECT-TYPE
okay the dot1dStp group is the spanning tree bit πΈ and it's optional, so only bridges that actually speak STP need it π«Ά
SYNTAX INTEGER {
unknown(1),
transparent-only(2),
sourceroute-only(3),
srt(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates what type of bridging this bridge can
perform. If a bridge is actually performing a
certain type of bridging this will be indicated by
entries in the port table for the given type."
::= { dot1dBase 3 }
-- The Generic Bridge Port Table
dot1dBasePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1dBasePortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains generic information about
every port that is associated with this bridge.
Transparent, source-route, and srt ports are
included."
::= { dot1dBase 4 }
dot1dBasePortEntry OBJECT-TYPE
SYNTAX Dot1dBasePortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of information for each port of the
bridge."
REFERENCE
"IEEE 802.1D-1990: Section 6.4.2, 6.6.1"
INDEX { dot1dBasePort }
::= { dot1dBasePortTable 1 }
Dot1dBasePortEntry ::=
SEQUENCE {
dot1dBasePort
INTEGER,
dot1dBasePortIfIndex
INTEGER,
dot1dBasePortCircuit
OBJECT IDENTIFIER,
dot1dBasePortDelayExceededDiscards
Counter,
dot1dBasePortMtuExceededDiscards
Counter
}
dot1dBasePort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number of the port for which this entry
contains bridge management information."
::= { dot1dBasePortEntry 1 }
dot1dBasePortIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of the instance of the ifIndex object,
defined in MIB-II, for the interface corresponding
to this port."
::= { dot1dBasePortEntry 2 }
dot1dBasePortCircuit OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"For a port which (potentially) has the same value
of dot1dBasePortIfIndex as another port on the
same bridge, this object contains the name of an
object instance unique to this port. For example,
in the case where multiple ports correspond one-
to-one with multiple X.25 virtual circuits, this
value might identify an (e.g., the first) object
instance associated with the X.25 virtual circuit
corresponding to this port.
For a port which has a unique value of
dot1dBasePortIfIndex, this object can have the
value { 0 0 }."
::= { dot1dBasePortEntry 3 }
dot1dBasePortDelayExceededDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames discarded by this port due
to excessive transit delay through the bridge. It
is incremented by both transparent and source
route bridges."
REFERENCE
"IEEE 802.1D-1990: Section 6.6.1.1.3"
::= { dot1dBasePortEntry 4 }
dot1dBasePortMtuExceededDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames discarded by this port due
to an excessive size. It is incremented by both
transparent and source route bridges."
REFERENCE
"IEEE 802.1D-1990: Section 6.6.1.1.3"
::= { dot1dBasePortEntry 5 }
-- the dot1dStp group
-- Implementation of the dot1dStp group is optional. It is
-- implemented by those bridges that support the Spanning Tree
-- Protocol.
dot1dStpProtocolSpecification OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
decLb100(2),
ieee8021d(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An indication of what version of the Spanning
Tree Protocol is being run. The value
'decLb100(2)' indicates the DEC LANbridge 100
Spanning Tree protocol. IEEE 802.1d
implementations will return 'ieee8021d(3)'. If
future versions of the IEEE Spanning Tree Protocol
are released that are incompatible with the
current version a new value will be defined."
::= { dot1dStp 1 }
dot1dStpPriority OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of the write-able portion of the Bridge
ID, i.e., the first two octets of the (8 octet
long) Bridge ID. The other (last) 6 octets of the
Bridge ID are given by the value of
dot1dBaseBridgeAddress."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.7"
::= { dot1dStp 2 }
dot1dStpTimeSinceTopologyChange OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time (in hundredths of a second) since the
last time a topology change was detected by the
bridge entity."
REFERENCE
"IEEE 802.1D-1990: Section 6.8.1.1.3"
::= { dot1dStp 3 }
dot1dStpTopChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of topology changes detected by
this bridge since the management entity was last
reset or initialized."
REFERENCE
"IEEE 802.1D-1990: Section 6.8.1.1.3"
::= { dot1dStp 4 }
dot1dStpDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The bridge identifier of the root of the spanning
tree as determined by the Spanning Tree Protocol
as executed by this node. This value is used as
the Root Identifier parameter in all Configuration
Bridge PDUs originated by this node."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.1"
::= { dot1dStp 5 }
dot1dStpRootCost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The cost of the path to the root as seen from
this bridge."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.2"
::= { dot1dStp 6 }
dot1dStpRootPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number of the port which offers the
lowest cost path from this bridge to the root
bridge."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.3"
::= { dot1dStp 7 }
dot1dStpMaxAge OBJECT-TYPE
SYNTAX Timeout
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum age of Spanning Tree Protocol
information learned from the network on any port
before it is discarded, in units of hundredths of
a second. This is the actual value that this
bridge is currently using."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.4"
::= { dot1dStp 8 }
dot1dStpHelloTime OBJECT-TYPE
SYNTAX Timeout
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of time between the transmission of
Configuration bridge PDUs by this node on any port
when it is the root of the spanning tree or trying
to become so, in units of hundredths of a second.
This is the actual value that this bridge is
currently using."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.5"
::= { dot1dStp 9 }
dot1dStpHoldTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This time value determines the interval length
during which no more than two Configuration bridge
PDUs shall be transmitted by this node, in units
of hundredths of a second."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.14"
::= { dot1dStp 10 }
dot1dStpForwardDelay OBJECT-TYPE
SYNTAX Timeout
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This time value, measured in units of hundredths
of a second, controls how fast a port changes its
spanning state when moving towards the Forwarding
state. The value determines how long the port
stays in each of the Listening and Learning
states, which precede the Forwarding state. This
value is also used, when a topology change has
been detected and is underway, to age all dynamic
entries in the Forwarding Database. [Note that
this value is the one that this bridge is
currently using, in contrast to
dot1dStpBridgeForwardDelay which is the value that
this bridge and all others would start using
if/when this bridge were to become the root.]"
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.6"
::= { dot1dStp 11 }
okay bestie, the bridge timers are up next π these are the values every bridge uses when it's the root, so they're kinda the main character of the spanning tree π
dot1dStpBridgeMaxAge OBJECT-TYPE
SYNTAX Timeout (600..4000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value that all bridges use for MaxAge when
this bridge is acting as the root. Note that
802.1D-1990 specifies that the range for this
parameter is related to the value of
dot1dStpBridgeHelloTime. The granularity of this
timer is specified by 802.1D-1990 to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.8"
::= { dot1dStp 12 }
dot1dStpBridgeHelloTime OBJECT-TYPE
SYNTAX Timeout (100..1000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value that all bridges use for HelloTime when
this bridge is acting as the root. The
granularity of this timer is specified by 802.1D-
1990 to be 1 second. An agent may return a
badValue error if a set is attempted to a value
which is not a whole number of seconds."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.9"
::= { dot1dStp 13 }
dot1dStpBridgeForwardDelay OBJECT-TYPE
SYNTAX Timeout (400..3000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value that all bridges use for ForwardDelay
when this bridge is acting as the root. Note that
802.1D-1990 specifies that the range for this
parameter is related to the value of
dot1dStpBridgeMaxAge. The granularity of this
timer is specified by 802.1D-1990 to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.3.10"
::= { dot1dStp 14 }
-- The Spanning Tree Port Table
dot1dStpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1dStpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains port-specific information
for the Spanning Tree Protocol."
::= { dot1dStp 15 }
dot1dStpPortEntry OBJECT-TYPE
SYNTAX Dot1dStpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of information maintained by every port
about the Spanning Tree Protocol state for that
port."
INDEX { dot1dStpPort }
::= { dot1dStpPortTable 1 }
Dot1dStpPortEntry ::=
SEQUENCE {
dot1dStpPort
INTEGER,
dot1dStpPortPriority
INTEGER,
dot1dStpPortState
INTEGER,
dot1dStpPortEnable
INTEGER,
dot1dStpPortPathCost
INTEGER,
dot1dStpPortDesignatedRoot
BridgeId,
dot1dStpPortDesignatedCost
INTEGER,
dot1dStpPortDesignatedBridge
BridgeId,
dot1dStpPortDesignatedPort
OCTET STRING,
dot1dStpPortForwardTransitions
Counter
}
dot1dStpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number of the port for which this entry
contains Spanning Tree Protocol management
information."
REFERENCE
"IEEE 802.1D-1990: Section 6.8.2.1.2"
::= { dot1dStpPortEntry 1 }
dot1dStpPortPriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of the priority field which is
contained in the first (in network byte order)
octet of the (2 octet long) Port ID. The other
octet of the Port ID is given by the value of
dot1dStpPort."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.1"
::= { dot1dStpPortEntry 2 }
dot1dStpPortState OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
blocking(2),
listening(3),
learning(4),
forwarding(5),
broken(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port's current state as defined by
application of the Spanning Tree Protocol. This
state controls what action a port takes on
reception of a frame. If the bridge has detected
a port that is malfunctioning it will place that
port into the broken(6) state. For ports which
are disabled (see dot1dStpPortEnable), this object
will have a value of disabled(1)."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.2"
::= { dot1dStpPortEntry 3 }
dot1dStpPortEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The enabled/disabled status of the port."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.2"
::= { dot1dStpPortEntry 4 }
dot1dStpPortPathCost OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The contribution of this port to the path cost of
paths towards the spanning tree root which include
this port. 802.1D-1990 recommends that the
default value of this parameter be in inverse
proportion to the speed of the attached LAN."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.3"
::= { dot1dStpPortEntry 5 }
dot1dStpPortDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique Bridge Identifier of the Bridge
recorded as the Root in the Configuration BPDUs
transmitted by the Designated Bridge for the
segment to which the port is attached."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.4"
::= { dot1dStpPortEntry 6 }
dot1dStpPortDesignatedCost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The path cost of the Designated Port of the
segment connected to this port. This value is
compared to the Root Path Cost field in received
bridge PDUs."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.5"
::= { dot1dStpPortEntry 7 }
dot1dStpPortDesignatedBridge OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bridge Identifier of the bridge which this
port considers to be the Designated Bridge for
this port's segment."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.6"
::= { dot1dStpPortEntry 8 }
dot1dStpPortDesignatedPort OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Port Identifier of the port on the Designated
Bridge for this port's segment."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.7"
::= { dot1dStpPortEntry 9 }
dot1dStpPortForwardTransitions OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times this port has transitioned
from the Learning state to the Forwarding state."
::= { dot1dStpPortEntry 10 }
-- the dot1dTp group
-- Implementation of the dot1dTp group is optional. It is
-- implemented by those bridges that support the transparent
-- bridging mode. A transparent or SRT bridge will implement
-- this group.
dot1dTpLearnedEntryDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of Forwarding Database entries,
which have been or would have been learnt, but
have been discarded due to a lack of space to
store them in the Forwarding Database. If this
counter is increasing, it indicates that the
Forwarding Database is regularly becoming full (a
condition which has unpleasant performance effects
on the subnetwork). If this counter has a
significant value but is not presently increasing,
it indicates that the problem has been occurring
but is not persistent."
REFERENCE
"IEEE 802.1D-1990: Section 6.7.1.1.3"
::= { dot1dTp 1 }
dot1dTpAgingTime OBJECT-TYPE
SYNTAX INTEGER (10..1000000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The timeout period in seconds for aging out
dynamically learned forwarding information.
802.1D-1990 recommends a default of 300 seconds."
REFERENCE
"IEEE 802.1D-1990: Section 6.7.1.1.3"
::= { dot1dTp 2 }
-- The Forwarding Database for Transparent Bridges
the port table is giving everything π§β¨ and the dot1dTp group is where the transparent bridge stuff lives πΈ
dot1dTpFdbTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1dTpFdbEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains information about unicast
entries for which the bridge has forwarding and/or
filtering information. This information is used
by the transparent bridging function in
determining how to propagate a received frame."
::= { dot1dTp 3 }
dot1dTpFdbEntry OBJECT-TYPE
SYNTAX Dot1dTpFdbEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about a specific unicast MAC address
for which the bridge has some forwarding and/or
filtering information."
INDEX { dot1dTpFdbAddress }
::= { dot1dTpFdbTable 1 }
Dot1dTpFdbEntry ::=
SEQUENCE {
dot1dTpFdbAddress
MacAddress,
dot1dTpFdbPort
INTEGER,
dot1dTpFdbStatus
INTEGER
}
Okay, so the forwarding database table (dot1dTpFdbTable) is basically the bridge's little black book of unicast MAC addresses πβ¨ Each row is one address the bridge has some forwarding and/or filtering info about, and the transparent bridging function uses that info to decide how to pass along a frame it receives. Each row is a dot1dTpFdbEntry, indexed by dot1dTpFdbAddress. Literally the main character of the bridge π
dot1dTpFdbAddress OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unicast MAC address for which the bridge has
forwarding and/or filtering information."
REFERENCE
"IEEE 802.1D-1990: Section 3.9.1, 3.9.2"
::= { dot1dTpFdbEntry 1 }
dot1dTpFdbPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Either the value '0', or the port number of the
port on which a frame having a source address
equal to the value of the corresponding instance
of dot1dTpFdbAddress has been seen. A value of
'0' indicates that the port number has not been
learned but that the bridge does have some
forwarding/filtering information about this
address (e.g. in the dot1dStaticTable).
Implementors are encouraged to assign the port
value to this object whenever it is learned even
for addresses for which the corresponding value of
dot1dTpFdbStatus is not learned(3)."
::= { dot1dTpFdbEntry 2 }
dot1dTpFdbStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
invalid(2),
learned(3),
self(4),
mgmt(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of this entry. The meanings of the
values are:
other(1) : none of the following. This would
include the case where some other
MIB object (not the corresponding
instance of dot1dTpFdbPort, nor an
entry in the dot1dStaticTable) is
being used to determine if and how
frames addressed to the value of
the corresponding instance of
dot1dTpFdbAddress are being
forwarded.
invalid(2) : this entry is not longer valid
(e.g., it was learned but has since
aged-out), but has not yet been
flushed from the table.
learned(3) : the value of the corresponding
instance of dot1dTpFdbPort was
learned, and is being used.
self(4) : the value of the corresponding
instance of dot1dTpFdbAddress
represents one of the bridge's
addresses. The corresponding
instance of dot1dTpFdbPort
indicates which of the bridge's
ports has this address.
mgmt(5) : the value of the corresponding
instance of dot1dTpFdbAddress is
also the value of an existing
instance of dot1dStaticAddress."
::= { dot1dTpFdbEntry 3 }
Each column in the forwarding database row has its own vibe π. The address column is the MAC address the bridge knows about, and the port column is either 0 (meaning the bridge has some info but the port hasn't been learned yet, like from the static table) or the port number where a frame with that source address was seen. The status column is an enum, and it's giving a lot of drama: other(1), invalid(2), learned(3), self(4), and mgmt(5), each with its own meaning. Fun little detail: implementors are encouraged to fill in the port whenever it's learned, even if the status isn't learned(3) π«Ά
-- Port Table for Transparent Bridges
dot1dTpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1dTpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains information about every
port that is associated with this transparent
bridge."
::= { dot1dTp 4 }
dot1dTpPortEntry OBJECT-TYPE
SYNTAX Dot1dTpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of information for each port of a
transparent bridge."
INDEX { dot1dTpPort }
::= { dot1dTpPortTable 1 }
Dot1dTpPortEntry ::=
SEQUENCE {
dot1dTpPort
INTEGER,
dot1dTpPortMaxInfo
INTEGER,
dot1dTpPortInFrames
Counter,
dot1dTpPortOutFrames
Counter,
dot1dTpPortInDiscards
Counter
}
dot1dTpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number of the port for which this entry
contains Transparent bridging management
information."
::= { dot1dTpPortEntry 1 }
-- It would be nice if we could use ifMtu as the size of the
-- largest INFO field, but we can't because ifMtu is defined
-- to be the size that the (inter-)network layer can use which
-- can differ from the MAC layer (especially if several layers
-- of encapsulation are used).
dot1dTpPortMaxInfo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum size of the INFO (non-MAC) field that
this port will receive or transmit."
::= { dot1dTpPortEntry 2 }
dot1dTpPortInFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames that have been received by
this port from its segment. Note that a frame
received on the interface corresponding to this
port is only counted by this object if and only if
it is for a protocol being processed by the local
bridging function, including bridge management
frames."
REFERENCE
"IEEE 802.1D-1990: Section 6.6.1.1.3"
::= { dot1dTpPortEntry 3 }
dot1dTpPortOutFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames that have been transmitted
by this port to its segment. Note that a frame
transmitted on the interface corresponding to this
port is only counted by this object if and only if
it is for a protocol being processed by the local
bridging function, including bridge management
frames."
REFERENCE
"IEEE 802.1D-1990: Section 6.6.1.1.3"
::= { dot1dTpPortEntry 4 }
dot1dTpPortInDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count of valid frames received which were
discarded (i.e., filtered) by the Forwarding
Process."
REFERENCE
"IEEE 802.1D-1990: Section 6.6.1.1.3"
::= { dot1dTpPortEntry 5 }
Next up is the port table for transparent bridges (dot1dTpPortTable) πΈ, which holds info about every port tied to the bridge, indexed by dot1dTpPort. The port number itself ranges from 1 to 65535. There's also a little comment in here, which I'm obsessed with, about why ifMtu can't just be used for the largest INFO field size, since it's defined in terms of what the network layer can use and that can differ from the MAC layer π The counters (dot1dTpPortInFrames, dot1dTpPortOutFrames, and dot1dTpPortInDiscards) all reference IEEE 802.1D-1990, and the in and out ones only count frames for protocols the local bridging function is processing, bridge management frames included π
-- The Static (Destination-Address Filtering) Database
-- Implementation of this group is optional.
dot1dStaticTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot1dStaticEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table containing filtering information
configured into the bridge by (local or network)
management specifying the set of ports to which
frames received from specific ports and containing
specific destination addresses are allowed to be
forwarded. The value of zero in this table as the
port number from which frames with a specific
destination address are received, is used to
specify all ports for which there is no specific
entry in this table for that particular
destination address. Entries are valid for
unicast and for group/broadcast addresses."
REFERENCE
"IEEE 802.1D-1990: Section 6.7.2"
::= { dot1dStatic 1 }
dot1dStaticEntry OBJECT-TYPE
SYNTAX Dot1dStaticEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Filtering information configured into the bridge
by (local or network) management specifying the
set of ports to which frames received from a
specific port and containing a specific
destination address are allowed to be forwarded."
REFERENCE
"IEEE 802.1D-1990: Section 6.7.2"
INDEX { dot1dStaticAddress, dot1dStaticReceivePort }
::= { dot1dStaticTable 1 }
Dot1dStaticEntry ::=
SEQUENCE {
dot1dStaticAddress
MacAddress,
dot1dStaticReceivePort
INTEGER,
dot1dStaticAllowedToGoTo
OCTET STRING,
dot1dStaticStatus
INTEGER
}
And last but definitely not least, we've got the static (destination-address filtering) database π§ This part is marked as optional to implement, so keep that in mind π The static table is filtering info that's configured into the bridge by local or network management, saying which ports frames from specific ports with specific destination addresses are allowed to be forwarded to. A value of zero for the receive port is a catch-all for any port that doesn't have its own specific entry for that destination address π Entries can be unicast or group/broadcast addresses, which is iconic π Each static entry is indexed by dot1dStaticAddress and dot1dStaticReceivePort.
dot1dStaticAddress OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The destination MAC address in a frame to which
this entry's filtering information applies. This
object can take the value of a unicast address, a
group address or the broadcast address."
REFERENCE
"IEEE 802.1D-1990: Section 3.9.1, 3.9.2"
::= { dot1dStaticEntry 1 }
dot1dStaticReceivePort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Either the value '0', or the port number of the
port from which a frame must be received in order
for this entry's filtering information to apply.
A value of zero indicates that this entry applies
on all ports of the bridge for which there is no
other applicable entry."
::= { dot1dStaticEntry 2 }
dot1dStaticAllowedToGoTo OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The set of ports to which frames received from a
specific port and destined for a specific MAC
address, are allowed to be forwarded. Each octet
within the value of this object specifies a set of
eight ports, with the first octet specifying ports
1 through 8, the second octet specifying ports 9
through 16, etc. Within each octet, the most
significant bit represents the lowest numbered
port, and the least significant bit represents the
highest numbered port. Thus, each port of the
bridge is represented by a single bit within the
value of this object. If that bit has a value of
'1' then that port is included in the set of
ports; the port is not included if its bit has a
value of '0'. (Note that the setting of the bit
corresponding to the port from which a frame is
received is irrelevant.) The default value of
this object is a string of ones of appropriate
length."
::= { dot1dStaticEntry 3 }
dot1dStaticStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
invalid(2),
permanent(3),
deleteOnReset(4),
deleteOnTimeout(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the status of this entry.
The default value is permanent(3).
other(1) - this entry is currently in use but
the conditions under which it will
remain so are different from each of the
following values.
invalid(2) - writing this value to the object
removes the corresponding entry.
permanent(3) - this entry is currently in use
and will remain so after the next reset
of the bridge.
deleteOnReset(4) - this entry is currently in
use and will remain so until the next
reset of the bridge.
deleteOnTimeout(5) - this entry is currently
in use and will remain so until it is
aged out."
::= { dot1dStaticEntry 4 }
-- Traps for use by Bridges
-- Traps for the Spanning Tree Protocol
newRoot TRAP-TYPE
ENTERPRISE dot1dBridge
DESCRIPTION
"The newRoot trap indicates that the sending agent
has become the new root of the Spanning Tree; the
trap is sent by a bridge soon after its election
as the new root, e.g., upon expiration of the
Topology Change Timer immediately subsequent to
its election. Implementation of this trap is
optional."
::= 1
topologyChange TRAP-TYPE
ENTERPRISE dot1dBridge
DESCRIPTION
"A topologyChange trap is sent by a bridge when
any of its configured ports transitions from the
Learning state to the Forwarding state, or from
the Forwarding state to the Blocking state. The
trap is not sent if a newRoot trap is sent for the
same transition. Implementation of this trap is
optional."
::= 2
END
6. Acknowledgments β¨
This document was whipped up for the Bridge Sub-Working Group of the SNMP Working Group of the Internet Engineering Task Force, and the working group got four separate submissions to use as a starting point. Stan Froyd of Advanced Computer Communications sent in the first one, Richard Fox of SynOptics sent the second, Eric Decker of cisco Inc. and Keith McCloghrie of Hughes LAN Systems teamed up for the third, and Paul Langille and Anil Rijsinghani of Digital Equipment Corp. sent the fourth. After looking at all of them, the group went with a blend of the last two submissions, and this document is the result. π
The authors also want to thank everyone in the Bridge Working Group for their comments and suggestions, which made this so much better. Big shoutouts to Fred Baker (the chairman of the working group) of ACC, Steve Sherry of Xyplex, and Frank Kastenholz of Clearpoint Research Corp. π«Ά Here's the full crew of other Bridge Working Group members who helped out:
Bill Anderson, Mitre
Karl Auerbach, Epilogue
Fred Baker, ACC (chair)
Terry Bradley, Wellfleet
Ted Brunner, Bellcore
Jeffrey Buffum, Apollo
Chris ChioTasso, Fibronics
Anthony Chung, HLS
Chuck Davin, MIT-LCS
Andy Davis, Spider
Eric Decker, cisco
Nadya El-Afandi, Network Systems
Gary Ellis,HP/Apollo
Richard Fox, SynOptics
Stan Froyd, ACC
Frank Kastenholz, Clearpoint Research
Shirnshon Kaufman,
Jim Kinder, Fibercom
Cheryl Krupczak,NCR
Paul Langille, Digital
Peter Lin,Vitalink
Keith McCloghrie, HLS
Donna McMaster, SynOptics
Dave Perkins, 3Com
Jim Reinstedler, Ungermann Bass
Anil Rijsinghani, Digital
Mark Schaefer, David Systems
Steve Sherry, Xyplex
Bob Stewart, Xyplex
Emil Sturniolo,
Kevin Synott, Retix
Ian Thomas, Chipcom
Maurice Turcott, Racal
Fei Xu,
7. References π
Here are all the references the document leans on, bestie, so you can go read the originals if you want the full picture. π§
- [1] Cerf, V., "IAB Recommendations for the Development of Internet Network Management Standards", RFC 1052, NRI, April 1988.
- [2] Cerf, V., "Report of the Second Ad Hoc Network Management Review Group", RFC 1109, NRI, August 1989.
- [3] Rose M., and K. McCloghrie, "Structure and Identification of Management Information for TCP/IP-based internets", STD 16, RFC 1155, Performance Systems International, Hughes LAN Systems, May 1990.
- [4] Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple Network Management Protocol", STD 15, RFC 1157, SNMP Research, Performance Systems International, Performance Systems International, MIT Laboratory for Computer Science, May 1990.
- [5] McCloghrie K., and M. Rose, Editors, "Management Information Base for Network Management of TCP/IP-based internets", STD 17, RFC 1213, Performance Systems International, March 1991.
- [6] Information processing systems - Open Systems Interconnection - Specification of Abstract Syntax Notation One (ASN.1), International Organization for Standardization, International Standard 8824, December 1987.
- [7] Information processing systems - Open Systems Interconnection - Specification of Basic Encoding Rules for Abstract Notation One (ASN.1), International Organization for Standardization, International Standard 8825, December 1987.
- [8] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions", STD 16, RFC 1212, Performance Systems International, Hughes LAN Systems, March 1991.
- [9] Rose, M., Editor, "A Convention for Defining Traps for use with the SNMP", RFC 1215, Performance Systems International, March 1991.
- [10] ANSI/IEEE Standard 802.1D-1990 MAC Bridges, IEEE Project 802 Local and Metropolitan Area Networks, (March 8, 1991).
- [11] ISO DIS 10038 MAC Bridges.
8. Security Considerations π
Security issues are not discussed in this memo. π
9. Authors' Addresses π
Meet the people who wrote this, bestie. π¦
Eric B. Decker
cisco Systems, Inc.
1525 O'Brien Dr.
Menlo Park, CA 94025
Phone: (415) 326-1941
Email: cire@cisco.com
Paul Langille
Digital Equipment Corporation
Digital Drive, MK02-2/K03
Merrimack, NH 03054
Phone: (603) 884-4045
EMail: langille@edwin.enet.dec.com
Anil Rijsinghani
Digital Equipment Corporation
550 King Street
Littleton, MA 01460
Phone: (508) 486-6786
EMail: anil@levers.enet.dec.com
Keith McCloghrie
Hughes LAN Systems, Inc.
1225 Charleston Road
Mountain View, CA 94043
Phone: (415) 966-7934
EMail: kzm@hls.com
π¦ where this page comes from
- ietf: rfc1493 1993-07
- π girlified by claude-haiku-5-5 on : a language model's rewrite of the original, under its terms