zpcimon(8)

πŸ“¦ version 2.44.1, in opensuse-leap 16.0

πŸŽ€ NAME πŸŽ€

okay so welcome to zpcimon(8) β€” yep, the zpcictl manual page, bestie πŸ’…. This is the tool for monitoring the health of directly attached PCI devices, including NVMes and NICs. It’s giving β€œwellness check but for your hardware” ✨.

🌸 SYNOPSIS 🌸

zpcimon OPTIONS

πŸ’– DESCRIPTION πŸ’–

Use zpcimon to monitor the health of the optical modules of directly attached PCI based NICs and the health of NVMe devices using their SMART data 🫢. When executed without the --monitor option, it will collect health data from all available and relevant PCI devices and print a summary in JSON format. Add the --send-report option to report this data to the support element πŸ’Œ.

πŸ¦‹ OPTIONS πŸ¦‹

Operation Options

  • -m, --monitor β€” Run continuously and monitor all supported devices. On link state changes, optical module data is collected, and NVMe SMART data is collected on hotplug. Moreover, every --interval seconds, data from all adapters is collected as a whole system snapshot πŸ”₯.
  • -r, --send-report β€” Report the optics and NVMe health data to the Support Element (SE) πŸ“¨.
  • -q, --quiet β€” Be quiet and don’t print health summaries 🀫.
  • -i seconds, --interval seconds β€” Interval in seconds at which to collect monitoring data in the absence of link state changes. A value larger than 24 hours (86400 seconds) is clamped down to 24 hours ⏳.
  • --module-info β€” Include a base64 encoded binary dump of the module’s SFF-8636/8472/8024 standard data for each netdev. This matches ethtool --module-info <netdev> raw on 🧚.

Example: Extract module information for the first adapter

zpcimon --module-info | jq -r '.adapters[0].netdevs[0].optics.module_info' | base64 -d | hexdump -C
  • --smart-log-raw β€” Include a base64 encoded binary dump of each NVMe’s SMART data. This matches nvme smart-log --output-format=binary /dev/nvmeX πŸ’Ύ.

Output Format Options

  • --format <FORMAT> β€” Set the output format out of json, json-seq, jsonl, pairs, and csv. Note that only json-seq and jsonl sequence formats are supported for monitoring mode, as they handle a continuous stream of updates well. While they are not supported in query mode πŸ‘€.

General Options

  • -h, --help β€” Print usage information, then exit 🌈.
  • -v, --version β€” Print version information, then exit ⭐.

okay bestie, that’s the whole vibe check 🫢 β€” this zpcimon(8) page comes from s390-tools, dated Oct 2024. slay and stay healthy βœ¨πŸ’…