okay bestie, gather round ๐Ÿ’– this is the manual page for riello_ser, and it's literally the driver for Riello UPS Protocol UPS equipment that you hook up over serial port connections. section 8, system administration, main character energy, no cap. ๐ŸŽ€


๐ŸŒธ SYNOPSIS ๐ŸŒธ

riello_ser -h

riello_ser -a UPS_NAME [OPTIONS]
Note ๐Ÿซถ okay so important thing: this man page only spills the tea on the hardware-specific features of the riello_ser driver. for the core driver deets, you gotta go read nutupsdrv(8). iykyk ๐Ÿ’…

๐Ÿฆ‹ SUPPORTED HARDWARE ๐Ÿฆ‹

riello_ser supports all recent Riello UPS and Aros UPS models which use the Riello UPS GPSER and SENTR protocols. slay โœจ

Older Riello UPS products? not supported. sorry bestie, it's giving deprecated ๐Ÿ’€


๐Ÿ’œ EXTRA ARGUMENTS ๐Ÿ’œ

depending on the make and model of your UPS, you might need to tweak some settings (peep ups.conf(5) for the full vibe check):

  • localcalculation โ€” when this is enabled, the driver will calculate the values of battery.runtime and battery.charge "locally" inside the driver itself. this is for those Riello models that be giving incorrect values in their hardware readings, or none at all ๐Ÿ˜ญ. this "local calculation" is done according to nominal battery capacity, nominal battery voltage, actual battery charge, maximum and actual UPS load. fr fr, it's doing math on your behalf ๐Ÿงฎโœจ

you may wanna also configure default.battery.voltage.low and default.battery.voltage.high in case the built-in default range (from 10.7V to 12.9V) does not match your hardware, or give a shot to default.battery.voltage.nominal (e.g. 24) if your device does not serve that either. ๐Ÿ‘‘

Note ๐ŸŽ€ Lead (PbAc) battery charge graph is not linear, so the guesstimated charge value may not be perfectly accurate. however, it should be good enough to determine battery actual status and roughly estimate the time it can still power the system. close enough honestly ๐Ÿ’…
Warning โš ๏ธ This keyword may be deprecated in future releases of the driver, in favor of runtimecal and other settings which it requires (as seen in nutdrv_qx(8), blazer_ser(8) and blazer_usb(8) drivers). not me warning you about the future ๐Ÿ”ฎ๐Ÿ˜ญ

โญ AUTHOR โญ

Massimo Zampieri ๐Ÿ‘‘


๐ŸŒˆ SEE ALSO ๐ŸŒˆ

๐Ÿซถ The core driver

๐ŸŒ Internet resources


okay that's the whole page bestie, you ate that ๐Ÿ’– this was Network UPS Tools 2.8.5, dated 10/07/2026 โ€” periodt. go forth and monitor your UPS, you iconic little sysadmin ๐ŸŽ€โœจ๐Ÿฆ‹