📦 libnvme-doc
1054 pages · page 3 of 6
N (continued)
- nvme_id_ctrl_dctype(2)Discovery Controller types✨
- nvme_id_ctrl_dsto(2)Flags indicating the optional Device Self-test command or operation behaviors supported by the controller or NVM subsystem.✨
- nvme_id_ctrl_fcatt(2)This field indicates attributes of the controller that are specific to NVMe over Fabrics.✨
- nvme_id_ctrl_fna(2)This field indicates attributes for the Format NVM command.✨
- nvme_id_ctrl_frmw(2)Flags and values indicates capabilities regarding firmware updates from &struct nvme_id_ctrl.frmw.✨
- nvme_id_ctrl_fuses(2)This field indicates the fused operations that the controller supports.✨
- nvme_id_ctrl_hctm(2)Flags indicate the attributes of the host controlled thermal management feature✨
- nvme_id_ctrl_kpioc(2)Key Per I/O Capabilities✨
- nvme_id_ctrl_lpa(2)Flags indicating optional attributes for log pages that are accessed via the Get Log Page command.✨
- nvme_id_ctrl_mec(2)Flags indicating the capabilities of the Management Endpoint in the Controller, &struct nvme_id_ctrl.mec.✨
- nvme_id_ctrl_nvm(2)I/O Command Set Specific Identify Controller data structure✨
- nvme_id_ctrl_nvm_lbamqf(2)LBA Migration Queue Format✨
- nvme_id_ctrl_nvmsr(2)This field reports information associated with the NVM Subsystem, see &struct nvme_id_ctrl.nvmsr.✨
- nvme_id_ctrl_nvscc(2)This field indicates the configuration settings for NVM Vendor Specific command handling.✨
- nvme_id_ctrl_nwpc(2)This field indicates the optional namespace write protection capabilities supported by the controller.✨
- nvme_id_ctrl_oacs(2)Flags indicating the optional Admin commands and features supported by the controller, see &struct nvme_id_ctrl.oacs.✨
- nvme_id_ctrl_oaes(2)Optional Asynchronous Events Supported✨
- nvme_id_ctrl_ofcs(2)Indicate whether the controller supports optional fabric commands.✨
- nvme_id_ctrl_oncs(2)This field indicates the optional NVM commands and features supported by the controller.✨
- nvme_id_ctrl_plsi(2)Power Loss Signaling Information✨
- nvme_id_ctrl_rpmbs(2)This field indicates if the controller supports one or more Replay Protected Memory Blocks, from &struct nvme_id_ctrl.rpmbs.✨
- nvme_id_ctrl_sanicap(2)Indicates attributes for sanitize operations.✨
- nvme_id_ctrl_sgls(2)This field indicates if SGLs are supported for the NVM Command Set and the particular SGL types supported.✨
- nvme_id_ctrl_sqes(2)Defines the required and maximum Submission Queue entry size when using the NVM Command Set.✨
- nvme_id_ctrl_trattr(2)Tracking Attributes✨
- nvme_id_ctrl_vwc(2)Volatile write cache✨
- nvme_id_ctrl_vwci(2)This field indicates information about remaining number of times that VPD contents are able to be updated using the VPD Write command, see &struct nvme_id_ctrl.vwci.✨
- nvme_id_directives(2)Identify Directive - Return Parameters Data Structure✨
- nvme_id_domain_attr(2)Domain Attributes Entry✨
- nvme_id_domain_list(2)Domain List✨
- nvme_id_endurance_group_list(2)Endurance Group List✨
- nvme_id_independent_id_ns(2)Identify - I/O Command Set Independent Identify Namespace Data Structure✨
- nvme_id_iocs(2)NVMe Identify IO Command Set data structure✨
- nvme_id_iocs_iocsc(2)This field indicates the Identify I/O Command Set Data Structure✨
- nvme_id_ns(2)Identify Namespace data structure✨
- nvme_id_ns_attr(2)Specifies attributes of the namespace.✨
- nvme_id_ns_dlfeat(2)This field indicates information about features that affect deallocating logical blocks for this namespace.✨
- nvme_id_ns_dpc(2)This field indicates the capabilities for the end- to-end data protection feature.✨
- nvme_id_ns_dps(2)This field indicates the Type settings for the end-to-end data protection feature.✨
- nvme_id_ns_flbas(2)This field indicates the LBA data size & metadata size combination that the namespace has been formatted with✨
- nvme_id_ns_granularity_desc(2)Namespace Granularity Descriptor✨
- nvme_id_ns_granularity_list(2)Namespace Granularity List✨
- nvme_id_ns_mc(2)This field indicates the capabilities for metadata.✨
- nvme_id_ns_nmic(2)This field specifies multi-path I/O and namespace sharing capabilities of the namespace.✨
- nvme_id_ns_rescap(2)This field indicates the reservation capabilities of the namespace.✨
- nvme_id_nsfeat(2)This field defines features of the namespace.✨
- nvme_id_nvmset_list(2)NVM set list✨
- nvme_id_psd(2)Power Management data structure✨
- nvme_id_uuid(2)Identifier Association✨
- nvme_id_uuid_list(2)UUID list✨
- nvme_id_uuid_list_entry(2)UUID List Entry✨
- nvme_identify(2)Send the NVMe Identify command✨
- nvme_identify_active_ns_list(2)Retrieves active namespaces id list✨
- nvme_identify_active_ns_list_csi(2)Active namespace ID list associated with a specified I/O command set✨
- nvme_identify_allocated_ns(2)Same as nvme_identify_ns, but only for allocated namespaces✨
- nvme_identify_allocated_ns_list(2)Retrieves allocated namespace id list✨
- nvme_identify_allocated_ns_list_csi(2)Allocated namespace ID list associated with a specified I/O command set✨
- nvme_identify_args(2)Arguments for the NVMe Identify command✨
- nvme_identify_cns(2)Identify - CNS Values✨
- nvme_identify_ctrl(2)Retrieves nvme identify controller✨
- nvme_identify_ctrl_csi(2)I/O command set specific Identify Controller data✨
- nvme_identify_ctrl_list(2)Retrieves identify controller list✨
- nvme_identify_domain_list(2)Domain list data✨
- nvme_identify_endurance_group_list(2)Endurance group list data✨
- nvme_identify_independent_identify_ns(2)I/O command set independent Identify namespace data✨
- nvme_identify_iocs(2)I/O command set data structure✨
- nvme_identify_iocs_ns_csi_user_data_format(2)Identify I/O command set namespace data structure✨
- nvme_identify_ns(2)Retrieves nvme identify namespace✨
- nvme_identify_ns_csi(2)I/O command set specific identify namespace data✨
- nvme_identify_ns_csi_user_data_format(2)Identify namespace user data format✨
- nvme_identify_ns_descs(2)Retrieves namespace descriptor list✨
- nvme_identify_ns_granularity(2)Retrieves namespace granularity identification✨
- nvme_identify_nsid_ctrl_list(2)Retrieves controller list attached to an nsid✨
- nvme_identify_nvmset_list(2)Retrieves NVM Set List✨
- nvme_identify_primary_ctrl(2)Retrieve NVMe Primary Controller identification✨
- nvme_identify_secondary_ctrl_list(2)Retrieves secondary controller list✨
- nvme_identify_uuid(2)Retrieves device's UUIDs✨
- nvme_import_tls_key(2)Import a TLS key✨
- nvme_import_tls_key_versioned(2)Import a TLS key✨
- nvme_init_copy_range(2)Constructs a copy range structure✨
- nvme_init_copy_range_f1(2)Constructs a copy range f1 structure✨
- nvme_init_copy_range_f2(2)Constructs a copy range f2 structure✨
- nvme_init_copy_range_f3(2)Constructs a copy range f3 structure✨
- nvme_init_ctrl(2)Initialize nvme_ctrl_t object for an existing controller.✨
- nvme_init_ctrl_list(2)Initialize an nvme_ctrl_list structure from an array.✨
- nvme_init_default_logging(2)Initialize default (fallback) logging✨
- nvme_init_dsm_range(2)Constructs a data set range structure✨
- nvme_init_logging(2)Initialize logging✨
- nvme_insert_tls_key(2)Derive and insert TLS key✨
- nvme_insert_tls_key_compat(2)Derive and insert TLS key✨
- nvme_insert_tls_key_versioned(2)Derive and insert TLS key✨
- nvme_io(2)Submit an nvme user I/O command✨
- nvme_io_args(2)Arguments for NVMe I/O commands✨
- nvme_io_control_flags(2)I/O control flags✨
- nvme_io_dsm_flags(2)Dataset Management flags✨
- nvme_io_mgmt_recv(2)I/O Management Receive command✨
- nvme_io_mgmt_recv_args(2)Arguments for the NVMe I/O Management Receive command✨
- nvme_io_mgmt_recv_mo(2)I/O Management Receive - Management Operation✨
- nvme_io_mgmt_send(2)I/O Management Send command✨
- nvme_io_mgmt_send_args(2)Arguments for the NVMe I/O Management Send command✨
- nvme_io_mgmt_send_mo(2)I/O Management Send - Management Operation✨
- nvme_io_opcode(2)Opcodes for I/O Commands✨
- nvme_io_passthru(2)Submit an nvme io passthrough command✨
- nvme_io_passthru64(2)Submit an nvme io passthrough command✨
- nvme_is_64bit_reg(2)Checks if offset of the controller register is a know 64bit value.✨
- nvme_kv_opcode(2)Opcodes for KV Commands✨
- nvme_lba_range_type(2)LBA Range Type✨
- nvme_lba_range_type_entry(2)LBA Range Type - Data Structure Entry✨
- nvme_lba_rd(2)LBA Range Descriptor✨
- nvme_lba_status(2)LBA Status Descriptor List✨
- nvme_lba_status_atype(2)Action type the controller uses to return LBA status✨
- nvme_lba_status_cmpc(2)Get LBA Status Command Completion Condition✨
- nvme_lba_status_desc(2)LBA Status Descriptor Entry✨
- nvme_lba_status_log(2)LBA Status Information Log✨
- nvme_lbaf(2)LBA Format Data Structure✨
- nvme_lbaf_rp(2)This field indicates the relative performance of the LBA format indicated relative to other LBA formats supported by the controller.✨
- nvme_lbart(2)LBA Range Type - Data Structure Entry✨
- nvme_lbas_ns_element(2)LBA Status Log Namespace Element✨
- nvme_lm_cdq(2)Controller Data Queue - Controller Data Queue command✨
- nvme_lm_cdq_args(2)Arguments for Controller Data Queue (CDQ) command✨
- nvme_lm_cdq_fields(2)Controller Data Queue command fields✨
- nvme_lm_controller_state_data(2)Controller State data structure contains data on the controller's state.✨
- nvme_lm_controller_state_data_header(2)Controller State data header structure describes the contents of the Controller State data✨
- nvme_lm_ctrl_data_queue_fid(2)Controller Data Queue - Set Feature✨
- nvme_lm_ctrl_data_queue_fid_data(2)Get Controller Data Queue feature data✨
- nvme_lm_io_completion_queue_data(2)I/O Completion Queue data structure. Fields related to the contents of Create I/O Completion Queue command that created an I/O Completion Queue.✨
- nvme_lm_io_submission_queue_data(2)I/O Submission Queue data structure. Fields related to the contents of Create I/O Submission Queue command that created an I/O Submission Queue.✨
- nvme_lm_migration_recv_args(2)Arguments for the Migration Receive command✨
- nvme_lm_migration_recv_fields(2)Migration Receive command fields✨
- nvme_lm_migration_send(2)Migration Send command✨
- nvme_lm_migration_send_args(2)Arguments for the Migration Send command✨
- nvme_lm_migration_send_fields(2)Migration Send command fields✨
- nvme_lm_nvme_controller_state_data(2)NVMe Controller State data structure describes the state of a NVMe Controller's I/O Submission and I/O Completion queues✨
- nvme_lm_nvme_controller_state_data_header(2)Controller State data structure header✨
- nvme_lm_queue_attributes(2)I/O Submission and I/O Completion Queue Attributes✨
- nvme_lm_track_send(2)Track Send command✨
- nvme_lm_track_send_args(2)Arguments for the Track Send command✨
- nvme_lm_track_send_fields(2)Track Send command fields✨
- nvme_lockdown(2)Issue lockdown command✨
- nvme_lockdown_args(2)Arguments for the NVME Lockdown command✨
- nvme_lockdown_log(2)Command and Feature Lockdown Log✨
- nvme_lockdown_log_contents(2)lockdown log page content attributes✨
- nvme_lockdown_log_scope(2)lockdown log page scope attributes✨
- nvme_lockdown_scope_contents(2)Lockdown Log shift and mask✨
- nvme_log_ana_lsp(2)Asymmetric Namespace Access - Return Groups Only✨
- nvme_log_phy_rx_eom_action(2)Physical Interface Receiver Eye Opening Measurement Action✨
- nvme_log_phy_rx_eom_quality(2)Physical Interface Receiver Eye Opening Measurement Quality✨
- nvme_lookup_ctrl(2)Lookup nvme_ctrl_t object✨
- nvme_lookup_host(2)Lookup nvme_host_t object✨
- nvme_lookup_key(2)Lookup key serial number✨
- nvme_lookup_keyring(2)Lookup keyring serial number✨
- nvme_lookup_subsystem(2)Lookup nvme_subsystem_t object✨
- nvme_media_unit_config_desc(2)Media Unit Configuration Descriptor✨
- nvme_media_unit_stat_desc(2)Media Unit Status Descriptor✨
- nvme_media_unit_stat_log(2)Media Unit Status✨
- nvme_metadata_element_desc(2)Metadata Element Descriptor✨
- nvme_mgmt_addr_desc(2)Management Address Descriptor✨
- nvme_mgmt_addr_list_log(2)Management Address List Log✨
- nvme_mi_admin_admin_passthru(2)Submit an nvme admin passthrough command✨
- nvme_mi_admin_format_nvm(2)Format NVMe namespace✨
- nvme_mi_admin_fw_commit(2)Commit firmware using the specified action✨
- nvme_mi_admin_fw_download(2)Download part or all of a firmware image to the controller✨
- nvme_mi_admin_get_ana_log_atomic(2)Retrieve Asymmetric Namespace Access log page atomically✨
- nvme_mi_admin_get_endgid_log(2)Helper for Get Endurance Group ID Log Page functions✨
- nvme_mi_admin_get_features_arbitration(2)Get arbitration feature✨
- nvme_mi_admin_get_features_data(2)Helper function for &nvme_mi_admin_get_features()✨
- nvme_mi_admin_get_features_power_mgmt(2)Get power management feature✨
- nvme_mi_admin_get_log(2)Retrieve log page data from controller✨
- nvme_mi_admin_get_log_ana(2)Retrieve Asymmetric Namespace Access log page✨
- nvme_mi_admin_get_log_ana_groups(2)Retrieve Asymmetric Namespace Access groups only log page✨
- nvme_mi_admin_get_log_ave_discover(2)Retrieve AVE Discovery Log✨
- nvme_mi_admin_get_log_boot_partition(2)Retrieve Boot Partition✨
- nvme_mi_admin_get_log_changed_alloc_ns_list(2)Retrieve Changed Allocated Namespace List Log✨
- nvme_mi_admin_get_log_changed_ns_list(2)Retrieve namespace changed list✨
- nvme_mi_admin_get_log_cmd_effects(2)Retrieve nvme command effects log✨
- nvme_mi_admin_get_log_create_telemetry_host(2)Create host telemetry log✨
- nvme_mi_admin_get_log_create_telemetry_host_mcda(2)Create host telemetry log✨
- nvme_mi_admin_get_log_device_self_test(2)Retrieve the device self test log✨
- nvme_mi_admin_get_log_discovery(2)Retrieve Discovery log page✨
- nvme_mi_admin_get_log_dispersed_ns_participating_nss(2)Retrieve Dispersed Namespace Participating NVM Subsystems Log✨
- nvme_mi_admin_get_log_endurance_group(2)Get Endurance Group log✨
- nvme_mi_admin_get_log_endurance_grp_evt(2)Retrieve Rotational Media Information✨
- nvme_mi_admin_get_log_error(2)Retrieve nvme error log✨
- nvme_mi_admin_get_log_fid_supported_effects(2)Retrieve Feature Identifiers Supported and Effects✨
- nvme_mi_admin_get_log_fw_slot(2)Retrieves the controller firmware log✨
- nvme_mi_admin_get_log_host_discover(2)Retrieve Host Discovery Log✨
- nvme_mi_admin_get_log_lba_status(2)Retrieve LBA Status✨
- nvme_mi_admin_get_log_lockdown(2)Retrieve lockdown Log✨
- nvme_mi_admin_get_log_media_unit_stat(2)Retrieve Media Unit Status✨
- nvme_mi_admin_get_log_mgmt_addr_list(2)Retrieve Management Address List Log✨
- nvme_mi_admin_get_log_mi_cmd_supported_effects(2)displays the MI Commands Supported by the controller✨
- nvme_mi_admin_get_log_page(2)Retrieve log page data from controller✨
- nvme_mi_admin_get_log_persistent_event(2)Retrieve Persistent Event Log✨
- nvme_mi_admin_get_log_phy_rx_eom(2)Retrieve Physical Interface Receiver Eye Opening Measurement Log✨
- nvme_mi_admin_get_log_predictable_lat_event(2)Retrieve Predictable Latency Event Aggregate Log Page✨
- nvme_mi_admin_get_log_predictable_lat_nvmset(2)Predictable Latency Per NVM Set✨
- nvme_mi_admin_get_log_pull_model_ddc_req(2)Retrieve Pull Model DDC Request Log✨
- nvme_mi_admin_get_log_reachability_associations(2)Retrieve Reachability Associations Log✨
- nvme_mi_admin_get_log_reachability_groups(2)Retrieve Reachability Groups Log✨
- nvme_mi_admin_get_log_reservation(2)Retrieve Reservation Notification✨
💅
getting it ready, bestie…