📦 libnvme-devel
902 pages · page 3 of 5
N (continued)
- nvme_id_ns_rescap(2)This field indicates the reservation capabilities of the namespace.✨
- nvme_id_nsfeat(2)This field defines features of the namespace.✨
- nvme_id_nvmset_list(2)NVM set list✨
- nvme_id_psd(2)Power Management data structure✨
- nvme_id_uuid(2)Identifier Association✨
- nvme_id_uuid_list(2)UUID list✨
- nvme_id_uuid_list_entry(2)UUID List Entry✨
- nvme_identify(2)Send the NVMe Identify command✨
- nvme_identify_active_ns_list(2)Retrieves active namespaces id list✨
- nvme_identify_active_ns_list_csi(2)Active namespace ID list associated with a specified I/O command set✨
- nvme_identify_allocated_ns(2)Same as nvme_identify_ns, but only for allocated namespaces✨
- nvme_identify_allocated_ns_list(2)Retrieves allocated namespace id list✨
- nvme_identify_allocated_ns_list_csi(2)Allocated namespace ID list associated with a specified I/O command set✨
- nvme_identify_cns(2)Identify - CNS Values✨
- nvme_identify_ctrl(2)Retrieves nvme identify controller✨
- nvme_identify_ctrl_csi(2)I/O command set specific Identify Controller data✨
- nvme_identify_ctrl_list(2)Retrieves identify controller list✨
- nvme_identify_domain_list(2)Domain list data✨
- nvme_identify_endurance_group_list(2)Endurance group list data✨
- nvme_identify_independent_identify_ns(2)I/O command set independent Identify namespace data✨
- nvme_identify_iocs(2)I/O command set data structure✨
- nvme_identify_iocs_ns_csi_user_data_format(2)Identify I/O command set namespace data structure✨
- nvme_identify_ns(2)Retrieves nvme identify namespace✨
- nvme_identify_ns_csi(2)I/O command set specific identify namespace data✨
- nvme_identify_ns_csi_user_data_format(2)Identify namespace user data format✨
- nvme_identify_ns_descs(2)Retrieves namespace descriptor list✨
- nvme_identify_ns_granularity(2)Retrieves namespace granularity identification✨
- nvme_identify_nsid_ctrl_list(2)Retrieves controller list attached to an nsid✨
- nvme_identify_nvmset_list(2)Retrieves NVM Set List✨
- nvme_identify_primary_ctrl(2)Retrieve NVMe Primary Controller identification✨
- nvme_identify_secondary_ctrl_list(2)Retrieves secondary controller list✨
- nvme_identify_uuid(2)Retrieves device's UUIDs✨
- nvme_import_tls_key(2)Import a TLS key✨
- nvme_import_tls_key_versioned(2)Import a TLS key✨
- nvme_init_copy_range(2)Constructs a copy range structure✨
- nvme_init_copy_range_f1(2)Constructs a copy range f1 structure✨
- nvme_init_copy_range_f2(2)Constructs a copy range f2 structure✨
- nvme_init_copy_range_f3(2)Constructs a copy range f3 structure✨
- nvme_init_ctrl(2)Initialize nvme_ctrl_t object for an existing controller.✨
- nvme_init_ctrl_list(2)Initialize an nvme_ctrl_list structure from an array.✨
- nvme_init_default_logging(2)Initialize default (fallback) logging✨
- nvme_init_dsm_range(2)Constructs a data set range structure✨
- nvme_init_logging(2)Initialize logging✨
- nvme_insert_tls_key(2)Derive and insert TLS key✨
- nvme_insert_tls_key_versioned(2)Derive and insert TLS key✨
- nvme_io(2)Submit an nvme user I/O command✨
- nvme_io_control_flags(2)I/O control flags✨
- nvme_io_dsm_flags(2)Dataset Management flags✨
- nvme_io_mgmt_recv(2)I/O Management Receive command✨
- nvme_io_mgmt_recv_mo(2)I/O Management Receive - Management Operation✨
- nvme_io_mgmt_send(2)I/O Management Send command✨
- nvme_io_mgmt_send_mo(2)I/O Management Send - Management Operation✨
- nvme_io_opcode(2)Opcodes for I/O Commands✨
- nvme_io_passthru(2)Submit an nvme io passthrough command✨
- nvme_io_passthru64(2)Submit an nvme io passthrough command✨
- nvme_is_64bit_reg(2)Checks if offset of the controller register is a know 64bit value.✨
- nvme_kv_opcode(2)Opcodes for KV Commands✨
- nvme_lba_range_type(2)LBA Range Type✨
- nvme_lba_range_type_entry(2)LBA Range Type - Data Structure Entry✨
- nvme_lba_rd(2)LBA Range Descriptor✨
- nvme_lba_status(2)LBA Status Descriptor List✨
- nvme_lba_status_atype(2)Action type the controller uses to return LBA status✨
- nvme_lba_status_cmpc(2)Get LBA Status Command Completion Condition✨
- nvme_lba_status_desc(2)LBA Status Descriptor Entry✨
- nvme_lba_status_log(2)LBA Status Information Log✨
- nvme_lbaf(2)LBA Format Data Structure✨
- nvme_lbaf_rp(2)This field indicates the relative performance of the LBA format indicated relative to other LBA formats supported by the controller.✨
- nvme_lbart(2)LBA Range Type - Data Structure Entry✨
- nvme_lbas_ns_element(2)LBA Status Log Namespace Element✨
- nvme_lockdown(2)Issue lockdown command✨
- nvme_lockdown_log(2)Command and Feature Lockdown Log✨
- nvme_lockdown_log_contents(2)lockdown log page content attributes✨
- nvme_lockdown_log_scope(2)lockdown log page scope attributes✨
- nvme_lockdown_scope_contents(2)Lockdown Log shift and mask✨
- nvme_log_ana_lsp(2)Asymmetric Namespace Access - Return Groups Only✨
- nvme_log_phy_rx_eom_action(2)Physical Interface Receiver Eye Opening Measurement Action✨
- nvme_log_phy_rx_eom_quality(2)Physical Interface Receiver Eye Opening Measurement Quality✨
- nvme_lookup_ctrl(2)Lookup nvme_ctrl_t object✨
- nvme_lookup_host(2)Lookup nvme_host_t object✨
- nvme_lookup_key(2)Lookup key serial number✨
- nvme_lookup_keyring(2)Lookup keyring serial number✨
- nvme_lookup_subsystem(2)Lookup nvme_subsystem_t object✨
- nvme_media_unit_config_desc(2)Media Unit Configuration Descriptor✨
- nvme_media_unit_stat_desc(2)Media Unit Status Descriptor✨
- nvme_media_unit_stat_log(2)Media Unit Status✨
- nvme_metadata_element_desc(2)Metadata Element Descriptor✨
- nvme_mi_admin_admin_passthru(2)Submit an nvme admin passthrough command✨
- nvme_mi_admin_format_nvm(2)Format NVMe namespace✨
- nvme_mi_admin_fw_commit(2)Commit firmware using the specified action✨
- nvme_mi_admin_fw_download(2)Download part or all of a firmware image to the controller✨
- nvme_mi_admin_get_ana_log_atomic(2)Retrieve Asymmetric Namespace Access log page atomically✨
- nvme_mi_admin_get_features_data(2)Helper function for &nvme_mi_admin_get_features()✨
- nvme_mi_admin_get_log(2)Retrieve log page data from controller✨
- nvme_mi_admin_get_log_ana(2)Retrieve Asymmetric Namespace Access log page✨
- nvme_mi_admin_get_log_ana_groups(2)Retrieve Asymmetric Namespace Access groups only log page✨
- nvme_mi_admin_get_log_boot_partition(2)Retrieve Boot Partition✨
- nvme_mi_admin_get_log_changed_ns_list(2)Retrieve namespace changed list✨
- nvme_mi_admin_get_log_cmd_effects(2)Retrieve nvme command effects log✨
- nvme_mi_admin_get_log_create_telemetry_host(2)Create host telemetry log✨
- nvme_mi_admin_get_log_device_self_test(2)Retrieve the device self test log✨
- nvme_mi_admin_get_log_discovery(2)Retrieve Discovery log page✨
- nvme_mi_admin_get_log_endurance_group(2)Get Endurance Group log✨
- nvme_mi_admin_get_log_endurance_grp_evt(2)Retrieve Rotational Media Information✨
- nvme_mi_admin_get_log_error(2)Retrieve nvme error log✨
- nvme_mi_admin_get_log_fid_supported_effects(2)Retrieve Feature Identifiers Supported and Effects✨
- nvme_mi_admin_get_log_fw_slot(2)Retrieves the controller firmware log✨
- nvme_mi_admin_get_log_lba_status(2)Retrieve LBA Status✨
- nvme_mi_admin_get_log_lockdown(2)Retrieve lockdown Log✨
- nvme_mi_admin_get_log_media_unit_stat(2)Retrieve Media Unit Status✨
- nvme_mi_admin_get_log_mi_cmd_supported_effects(2)displays the MI Commands Supported by the controller✨
- nvme_mi_admin_get_log_page(2)Retrieve log page data from controller✨
- nvme_mi_admin_get_log_persistent_event(2)Retrieve Persistent Event Log✨
- nvme_mi_admin_get_log_phy_rx_eom(2)Retrieve Physical Interface Receiver Eye Opening Measurement Log✨
- nvme_mi_admin_get_log_predictable_lat_event(2)Retrieve Predictable Latency Event Aggregate Log Page✨
- nvme_mi_admin_get_log_predictable_lat_nvmset(2)Predictable Latency Per NVM Set✨
- nvme_mi_admin_get_log_reservation(2)Retrieve Reservation Notification✨
- nvme_mi_admin_get_log_sanitize(2)Retrieve Sanitize Status✨
- nvme_mi_admin_get_log_simple(2)Helper for Get Log Page functions with no NSID or RAE requirements✨
- nvme_mi_admin_get_log_smart(2)Retrieve nvme smart log✨
- nvme_mi_admin_get_log_support_cap_config_list(2)Retrieve Supported Capacity Configuration List✨
- nvme_mi_admin_get_log_supported_log_pages(2)Retrieve nmve supported log pages✨
- nvme_mi_admin_get_log_telemetry_ctrl(2)Get Telemetry Controller- Initiated log page✨
- nvme_mi_admin_get_log_telemetry_host(2)Get Telemetry Host-Initiated log page✨
- nvme_mi_admin_get_log_zns_changed_zones(2)Retrieve list of zones that have changed✨
- nvme_mi_admin_get_nsid_log(2)Helper for Get Log Page functions✨
- nvme_mi_admin_identify(2)Perform an Admin identify command.✨
- nvme_mi_admin_identify_active_ns_list(2)Perform an Admin identify for an active namespace list✨
- nvme_mi_admin_identify_allocated_ns(2)Perform an Admin identify command for an allocated namespace✨
- nvme_mi_admin_identify_allocated_ns_list(2)Perform an Admin identify for an allocated namespace list✨
- nvme_mi_admin_identify_cns_nsid(2)Perform an Admin identify command using specific CNS/NSID parameters.✨
- nvme_mi_admin_identify_ctrl(2)Perform an Admin identify for a controller✨
- nvme_mi_admin_identify_ctrl_list(2)Perform an Admin identify for a controller list.✨
- nvme_mi_admin_identify_ns(2)Perform an Admin identify command for a namespace✨
- nvme_mi_admin_identify_ns_descs(2)Perform an Admin identify Namespace Identification Descriptor list command for a namespace✨
- nvme_mi_admin_identify_nsid_ctrl_list(2)Perform an Admin identify for a controller list with specific namespace ID✨
- nvme_mi_admin_identify_partial(2)Perform an Admin identify command, and retrieve partial response data.✨
- nvme_mi_admin_identify_primary_ctrl(2)Perform an Admin identify for primary controller capabilities data structure.✨
- nvme_mi_admin_identify_secondary_ctrl_list(2)Perform an Admin identify for a secondary controller list.✨
- nvme_mi_admin_ns_attach(2)Attach or detach namespace to controller(s)✨
- nvme_mi_admin_ns_attach_ctrls(2)Attach namespace to controllers✨
- nvme_mi_admin_ns_detach_ctrls(2)Detach namespace from controllers✨
- nvme_mi_admin_req_hdr(2)Admin command request header.✨
- nvme_mi_admin_resp_hdr(2)Admin command response header.✨
- nvme_mi_admin_sanitize_nvm(2)Start a subsystem Sanitize operation✨
- nvme_mi_admin_security_recv(2)Perform a Security Receive command on a controller.✨
- nvme_mi_admin_security_send(2)Perform a Security Send command on a controller.✨
- nvme_mi_admin_xfer(2)Raw admin transfer interface.✨
- nvme_mi_ccs(2)Get State Control Primitive Success Response Fields - Control Primitive Specific Response✨
- nvme_mi_close(2)Close an endpoint connection and release resources, including controller objects.✨
- nvme_mi_close_ctrl(2)free a controller✨
- nvme_mi_cmd_supported_effects(2)MI Command Supported and Effects Data Structure✨
- nvme_mi_cmd_supported_effects_log(2)NVMe-MI Commands Supported and Effects Log✨
- nvme_mi_config_id(2)NVMe-MI Configuration identifier.✨
- nvme_mi_config_smbus_freq(2)SMBus/I2C frequency values✨
- nvme_mi_control(2)Perform a Control Primitive command✨
- nvme_mi_control_opcode(2)Operation code for Control Primitives.✨
- nvme_mi_control_req(2)The Control Primitive request.✨
- nvme_mi_create_root(2)Create top-level MI (root) handle.✨
- nvme_mi_csts(2)Controller Health Data Structure (CHDS) - Controller Status (CSTS)✨
- nvme_mi_ctrl_health_status(2)Controller Health Data Structure (CHDS)✨
- nvme_mi_ctrl_id(2)get the ID of a controller✨
- nvme_mi_cwarn(2)Controller Health Data Structure (CHDS) - Critical Warning (CWARN)✨
- nvme_mi_dtyp(2)Data Structure Type field.✨
- nvme_mi_elem(2)Element Descriptor Types✨
- nvme_mi_free_root(2)Free root object.✨
- nvme_mi_init_ctrl(2)initialise a NVMe controller.✨
- nvme_mi_message_type(2)NVMe-MI message type field.✨
- nvme_mi_mi_opcode(2)Operation code for supported NVMe-MI commands.✨
- nvme_mi_mi_read_mi_data_ctrl(2)Perform a Read MI Data Structure command, retrieving controller information✨
- nvme_mi_mi_read_mi_data_ctrl_list(2)Perform a Read MI Data Structure command, retrieving the list of attached controllers.✨
- nvme_mi_mi_read_mi_data_port(2)Perform a Read MI Data Structure command, retrieving port data.✨
- nvme_mi_mi_read_mi_data_subsys(2)Perform a Read MI Data Structure command, retrieving subsystem data.✨
- nvme_mi_mi_req_hdr(2)MI request message header.✨
- nvme_mi_mi_resp_hdr(2)MI response message header.✨
- nvme_mi_mi_subsystem_health_status_poll(2)Read the Subsystem Health Data Structure from the NVM subsystem✨
- nvme_mi_msg_hdr(2)General MI message header.✨
- nvme_mi_msg_resp(2)Generic response type.✨
- nvme_mi_nvm_ss_health_status(2)Subsystem Management Data Structure✨
- nvme_mi_open_mctp(2)Create an endpoint using a MCTP connection.✨
- nvme_mi_osc(2)Optionally Supported Command Data Structure✨
- nvme_mi_port_pcie(2)PCIe Port Specific Data✨
- nvme_mi_port_smb(2)SMBus Port Specific Data✨
- nvme_mi_read_ctrl_info(2)Controller Information Data Structure✨
- nvme_mi_read_nvm_ss_info(2)NVM Subsystem Information Data Structure✨
- nvme_mi_read_port_info(2)Port Information Data Structure✨
- nvme_mi_read_sc_list(2)Management Endpoint Buffer Supported Command List Data Structure✨
- nvme_mi_resp_status(2)values for the response status field✨
- nvme_mi_set_probe_enabled(2)enable/disable the probe for new endpoints✨
- nvme_mi_status_to_string(2)return a string representation of the MI status.✨
- nvme_mi_vpd_hdr(2)Vital Product Data Common Header✨
- nvme_mi_vpd_mr_common(2)NVMe MultiRecord Area✨
- nvme_mi_vpd_mra(2)NVMe MultiRecord Area✨
- nvme_mi_vpd_ppmra(2)NVMe PCIe Port MultiRecord Area✨
- nvme_mi_vpd_telem(2)Vital Product Data Element Descriptor✨
- nvme_mi_vpd_tra(2)Vital Product Data Topology MultiRecord✨
- nvme_namespace_attach_ctrls(2)Attach namespace to controller(s)✨
- nvme_namespace_detach_ctrls(2)Detach namespace from controller(s)✨
- nvme_namespace_filter(2)Filter for namespaces✨
- nvme_namespace_first_path(2)Start path iterator✨
- nvme_namespace_for_each_path(2)Traverse paths✨
💅
getting it ready, bestie…