RFC 8238

Data Center Benchmarking Terminology

๐Ÿ“… published August 2017, from ietf

Abstract โœจ

okay bestie, this informational doc is basically the glossary for data center benchmarking ๐ŸŽ€. It sets up definitions, explains how to measure things, and introduces new terms for testing data center network gear like switches and routers. It's the groundwork for the test methodology doc, RFC 8239, so you need this one first. A bunch of these terms could also work for network equipment outside the data center, since the tech from data centers is spreading everywhere now ๐ŸŒธ.

Status of This Memo ๐Ÿ“œ

This doc is not an Internet Standards Track spec. It's published just for info ๐Ÿฆ‹.

It's an IETF product and represents the consensus of the IETF community. It got public review and was approved for publication by the Internet Engineering Steering Group (IESG). Not every IESG-approved doc is a candidate for any level of Internet Standard, so check Section 2 of RFC 7841 if you're curious ๐Ÿง.

For the current status, errata, and how to send feedback, go to http://www.rfc-editor.org/info/rfc8238 ๐Ÿ’Œ.

Copyright (c) 2017 IETF Trust and the people listed as document authors. All rights reserved ๐Ÿ’œ.

This doc is subject to BCP 78 and the IETF Trust's Legal Provisions Relating to IETF Documents (http://trustee.ietf.org/license-info) as they stand on the publication date. Please actually read those, because they spell out your rights and restrictions ๐Ÿ™ˆ. Any Code Components pulled out of this doc must include the Simplified BSD License text, as described in Section 4.e of the Trust Legal Provisions. They come without warranty, as described in that Simplified BSD License ๐Ÿซถ.

Table of Contents ๐Ÿ—บ๏ธ

1. Introduction ....................................................4
   1.1. Requirements Language ......................................5
   1.2. Definition Format ..........................................5
2. Latency .........................................................5
   2.1. Definition .................................................5
   2.2. Discussion .................................................7
   2.3. Measurement Units ..........................................7
3. Jitter ..........................................................8
   3.1. Definition .................................................8
   3.2. Discussion .................................................8
   3.3. Measurement Units ..........................................8
4. Calibration of the Physical Layer ...............................9
   4.1. Definition .................................................9
   4.2. Discussion .................................................9
   4.3. Measurement Units ..........................................9
5. Line Rate ......................................................10
   5.1. Definition ................................................10
   5.2. Discussion ................................................10
   5.3. Measurement Units .........................................11
6. Buffering ......................................................12
   6.1. Buffer ....................................................12
        6.1.1. Definition .........................................12
        6.1.2. Discussion .........................................14
        6.1.3. Measurement Units ..................................14
   6.2. Incast ....................................................15
        6.2.1. Definition .........................................15
        6.2.2. Discussion .........................................15
        6.2.3. Measurement Units ..................................16
7. Application Throughput: Data Center Goodput ....................16
   7.1. Definition ................................................16
   7.2. Discussion ................................................16
   7.3. Measurement Units .........................................16
8. Security Considerations ........................................17
9. IANA Considerations ............................................18
10. References ....................................................18
   10.1. Normative References .....................................18
   10.2. Informative References ...................................19
Acknowledgments ...................................................20
Authors' Addresses ................................................20

1. Introduction ๐ŸŒˆ

Traffic in the data center is NOT uniform, and it keeps changing ๐Ÿ˜ญ. Whatever apps are running decides what it looks like. In one data center it might be mostly east-west traffic (server to server inside the data center), while another is mostly north-south (from outside the data center to a server), and some have both. Traffic can come in bursts and can be many-to-one, many-to-many, or one-to-many. Each flow might be small and latency sensitive, or big and throughput sensitive, and it can be a mix of UDP and TCP. All of that can live in one cluster and go through a single network device at the same time ๐Ÿคฏ.

Network devices have leaned on [RFC1242], [RFC2432], [RFC2544], [RFC2889], and [RFC3918] for benchmarking for ages ๐Ÿ“š. Those benchmarks mostly focus on different latency stuff and the max throughput of the Device Under Test (DUT) being benchmarked. They're pretty good at measuring theoretical max throughput, forwarding rates, and latency under test conditions, but they don't reflect the real traffic patterns that can affect these devices ๐Ÿ™ƒ. The data center devices this doc covers are switches and routers ๐Ÿ’….

Typical data center networking devices are characterized by:

  • High port density (48 ports or more) ๐Ÿ“.
  • High speed (currently, up to 100 GB/s per port) ๐Ÿ”ฅ.
  • High throughput (line rate on all ports for Layer 2 and/or Layer 3) ๐Ÿš€.
  • Low latency (in the microsecond or nanosecond range) โšก.
  • Low amount of buffer (in the MB range per networking device) ๐Ÿง.
  • Layer 2 and Layer 3 forwarding capability (Layer 3 not mandatory) ๐Ÿฆ‹.

This doc defines a set of definitions, metrics, and new terminology, including congestion scenarios and switch buffer analysis. It also redefines some basic definitions so they can represent a wide mix of traffic conditions โœจ. The test methodologies are defined in [RFC8239] ๐Ÿ’–.

1.1. Requirements Language ๐Ÿ”‘

The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in BCP 14 [RFC2119] [RFC8174] when, and only when, they appear in all capitals, as shown here ๐Ÿซถ.

1.2. Definition Format ๐Ÿ“

  • Term to be defined (e.g., "latency") ๐Ÿท๏ธ.
  • Definition: The specific definition for the term ๐ŸŽฏ.
  • Discussion: A brief discussion about the term, its application, and any restrictions on measurement procedures ๐Ÿ’ฌ.
  • Measurement Units: Methodology for measurements and units used to report measurements of the term in question, if applicable ๐Ÿ“.

2. Latency โฑ๏ธ

2.1. Definition ๐Ÿ’ญ

Latency is the amount of time it takes a frame to transit the DUT โณ. It's measured in units of time (seconds, milliseconds, microseconds, and so on) ๐Ÿ•ฐ๏ธ. The whole point of measuring latency is to understand the impact of adding a device to the communication path ๐Ÿง.

Latency intervals can be assessed between different combinations of events, no matter what kind of switching device it is (bit forwarding, aka cut-through; or a store-and-forward device) ๐Ÿ”€. [RFC1242] defined latency differently for each of these device types ๐Ÿ“–.

The traditional latency measurement definitions are:

  • FILO (First In Last Out):

The time interval starting when the end of the first bit of the input frame reaches the input port and ending when the last bit of the output frame is seen on the output port ๐Ÿฅ‡.

  • FIFO (First In First Out):

The time interval starting when the end of the first bit of the input frame reaches the input port and ending when the start of the first bit of the output frame is seen on the output port. Latency (as defined in [RFC1242]) for bit-forwarding devices uses these events ๐Ÿงƒ.

  • LILO (Last In Last Out):

The time interval starting when the last bit of the input frame reaches the input port and the last bit of the output frame is seen on the output port ๐Ÿซ .

  • LIFO (Last In First Out):

The time interval starting when the last bit of the input frame reaches the input port and ending when the first bit of the output frame is seen on the output port. Latency (as defined in [RFC1242]) for store-and-forward devices uses these events ๐Ÿ“ฆ.

Another way to sum up those four definitions is to look at the bit positions in the order they normally happen: input to output ๐Ÿ‘€.

  • FILO is FL (First bit Last bit) ๐ŸŒท.
  • FIFO is FF (First bit First bit) ๐ŸŒธ.
  • LILO is LL (Last bit Last bit) ๐Ÿ’œ.
  • LIFO is LF (Last bit First bit) ๐ŸŽ€.

This definition, explained in this section for data center switch benchmarking, is used instead of the previous "latency" definition in RFC 1242, Section 3.8. Here's that old definition quoted ๐Ÿ“œ:

For store and forward devices: The time interval starting when the last bit of the input frame reaches the input port and ending when the first bit of the output frame is seen on the output port. For bit forwarding devices: The time interval starting when the end of the first bit of the input frame reaches the input port and ending when the start of the first bit of the output frame is seen on the output port.

To cover both device types, plus the hybrids that have shown up, switch latency measurements made under this document MUST be measured with the FILO events ๐Ÿ”ฅ. FILO includes the switch's latency, the frame's latency, and the serialization delay. It's the full "whole" latency going through the DUT ๐ŸŒˆ. For latency-sensitive apps that can work with the initial bytes of the frame, FIFO (or, for bit-forwarding devices, latency per RFC 1242) MAY be used ๐Ÿฆ‹. In all cases, the event combinations used in latency measurements MUST be reported ๐Ÿ“ฃ.

2.2. Discussion ๐Ÿ’…

okay so, like I said in Section 2.1, FILO is the most important measuring definition ๐Ÿ‘‘

Not every DUT is strictly cut-through or store-and-forward ๐Ÿซถ Data center DUTs are often store-and-forward for smaller packet sizes and then switch over to cut-through behavior at specific larger packet sizes โœจ The packet size where that behavior changes MAY be configurable, depending on the DUT manufacturer ๐ŸŽ€ FILO covers both scenarios, store-and-forward and cut-through, so the threshold for the change does not matter for benchmarking ๐Ÿ’–

LIFO can be used with store-and-forward switches, but not with cut-through switches ๐Ÿ™ˆ It gives negative latency values for larger packet sizes because LIFO removes the serialization delay ๐Ÿ’€ So this mechanism MUST NOT be used when comparing the latencies of two different DUTs ๐Ÿšซ

2.3. Measurement Units ๐Ÿ“

The measuring methods to use for benchmarking purposes are as follows:

  1. FILO MUST be used as a measuring method, because it includes the latency of the packet ๐Ÿ“ Today, applications commonly need to read the whole packet to process the information and take an action.
  2. FIFO MAY be used for certain applications able to process the data as the first bits arrive, for example with a Field-Programmable Gate Array (FPGA) ๐Ÿงš
  3. LIFO MUST NOT be used, because unlike all the other methods, it subtracts the latency of the packet ๐Ÿ˜ญ

3. Jitter ๐Ÿฆ‹

3.1. Definition ๐ŸŒธ

In the context of the data center, jitter is synonymous with the common term "delay variation" ๐Ÿ’œ It is derived from multiple measurements of one-way delay, as described in RFC 3393. The mandatory definition of "delay variation" is the Packet Delay Variation (PDV) as defined in Section 4.2 of [RFC5481]. When considering a stream of packets, the delays of all packets are subtracted from the minimum delay over all packets in the stream โœจ This helps you assess the range of delay variation (Max - Min) or a high percentile of PDV (99th percentile, for robustness against outliers) ๐Ÿ”ฅ

When First-bit to Last-bit timestamps are used for delay measurement, delay variation MUST be measured using packets or frames of the same size, since the definition of latency includes the serialization time for each packet ๐Ÿซ  Otherwise, if using First-bit to First-bit, the size restriction does not apply ๐Ÿ™Œ

3.2. Discussion ๐Ÿง 

In addition to a PDV range and/or a high percentile of PDV, Inter-Packet Delay Variation (IPDV) as defined in Section 4.1 of [RFC5481] (differences between two consecutive packets) MAY be used to figure out how packet spacing has changed during transfer ๐Ÿ‘€ For example, you can check whether a packet stream has become closely spaced or "bursty" ๐Ÿ’… However, the absolute value of IPDV SHOULD NOT be used, because it "collapses" the "bursty" and "dispersed" sides of the IPDV distribution together ๐Ÿ™…โ€โ™€๏ธ

3.3. Measurement Units ๐ŸŽ€

The measurement of delay variation is expressed in units of seconds โฑ๏ธ A PDV histogram MAY be provided for the population of packets measured ๐Ÿ“Š


4. Calibration of the Physical Layer ๐ŸŒˆ

4.1. Definition ๐Ÿ› ๏ธ

Calibration of the physical layer consists of defining and measuring the latency of the physical devices used to perform tests on the DUT ๐Ÿงช

It includes the list of all physical-layer components used, as specified here:

  • Type of device used to generate traffic / measure traffic.
  • Type of line cards used on the traffic generator.
  • Type of transceivers on the traffic generator.
  • Type of transceivers on the DUT.
  • Type of cables.
  • Length of cables.
  • Software name and version of the traffic generator and DUT.
  • A list of enabled features on the DUT MAY be provided and is recommended (especially in the case of control-plane protocols, such as the Link Layer Discovery Protocol and Spanning Tree) ๐Ÿซถ A comprehensive configuration file MAY be provided to this effect ๐Ÿ“

4.2. Discussion ๐Ÿ’ญ

Calibration of the physical layer contributes to end-to-end latency and should be taken into account when evaluating the DUT ๐Ÿ‘€ Small variations in the physical components of the test may impact the latency being measured, so they MUST be described when presenting results ๐Ÿ“

4.3. Measurement Units ๐Ÿ“

It is RECOMMENDED that all cables used for testing (1) be of the same type and length and (2) come from the same vendor whenever possible ๐Ÿงฆ It is a MUST to document the cable specifications listed in Section 4.1, along with the test results ๐Ÿšจ The test report MUST specify whether or not the cable latency has been subtracted from the test measurements ๐Ÿงฎ The accuracy of the traffic-generator measurements MUST be provided (for current test equipment, this is usually a value within a range of 20 ns) ๐ŸŽฏ


5. Line Rate ๐ŸŽ๏ธ

5.1. Definition ๐Ÿ’จ

The transmit timing, or maximum transmitted data rate, is controlled by the "transmit clock" in the DUT โฐ The receive timing (maximum ingress data rate) is derived from the transmit clock of the connected interface ๐Ÿ”

The line rate or physical-layer frame rate is the maximum capacity to send frames of a specific size at the transmit clock frequency of the DUT ๐Ÿš€

The term "nominal value of line rate" defines the maximum speed capability for the given port, for example (expressed as Gigabit Ethernet), 1 GE, 10 GE, 40 GE, 100 GE ๐ŸŒŸ

The frequency ("clock rate") of the transmit clock in any two connected interfaces will never be precisely the same, so a tolerance is needed ๐Ÿ™ƒ This is expressed by a Parts Per Million (PPM) value ๐Ÿ”ข The IEEE standards allow a specific +/- variance in the transmit clock rate, and Ethernet is designed to allow for small, normal variations between the two clock rates ๐Ÿซง This results in a tolerance of the line-rate value when traffic is generated from test equipment to a DUT ๐Ÿ’œ

Line rate SHOULD be measured in frames per second (FPS) ๐ŸŽฏ

5.2. Discussion ๐Ÿญ

For a transmit clock source, most Ethernet switches use "clock modules" (also called "oscillator modules") that are sealed, internally temperature-compensated, and very accurate ๐ŸงŠ The output frequency of these modules is not adjustable because it is not necessary ๐Ÿคทโ€โ™€๏ธ Many test sets, however, offer a software-controlled adjustment of the transmit clock rate ๐ŸŽ›๏ธ These adjustments SHOULD be used to "compensate" the test equipment, so it does not send more than the line rate of the DUT ๐Ÿ™Œ

To allow for the minor variations typically found in the clock rate of commercially available clock modules and other crystal-based oscillators, Ethernet standards specify the maximum transmit clock-rate variation to be not more than +/- 100 PPM from a calculated center frequency ๐Ÿ“ Therefore, a DUT must be able to accept frames at a rate within +/- 100 PPM to comply with the standards โœ…

Very few clock circuits are precisely +/- 0.0 PPM because:

  1. The Ethernet standards allow a maximum variance of +/- 100 PPM over time. Therefore, it is normal for the frequency of the oscillator circuits to experience variation over time and over a wide temperature range, among other external factors ๐ŸŒก๏ธ
  2. The crystals, or clock modules, usually have a specific +/- PPM variance that is significantly better than +/- 100 PPM. Oftentimes, this is +/- 30 PPM or better in order to be considered a "certification instrument" ๐Ÿ…

When testing an Ethernet switch throughput at "line rate", any specific switch will have a clock-rate variance ๐Ÿ˜ฎโ€๐Ÿ’จ If a test set is running +1 PPM faster than a switch under test and a sustained line-rate test is performed, you can observe a gradual increase in latency and, eventually, packet drops as buffers fill and overflow in the switch ๐Ÿ“ˆ๐Ÿ’ฅ Depending on how much clock variance there is between the two connected systems, the effect may show up after the traffic stream has been running for a few hundred microseconds, a few milliseconds, or seconds โŒ› The same low latency and no packet loss can be demonstrated by setting the test set's link occupancy to slightly less than 100 percent link occupancy ๐Ÿซถ Typically, 99 percent link occupancy produces excellent low latency and no packet loss ๐ŸŒธ No Ethernet switch or router will have a transmit clock rate of exactly +/- 0.0 PPM, and very few (if any) test sets have a clock rate that is precisely +/- 0.0 PPM ๐Ÿคฏ

Test-set equipment manufacturers are well aware of the standards and allow a software-controlled +/- 100 PPM "offset" (clock-rate adjustment) to compensate for normal variations in the clock speed of DUTs ๐Ÿง‘โ€๐Ÿ”ง This offset adjustment lets engineers determine the approximate speed at which the connected device is operating and verify that it is within parameters allowed by standards ๐Ÿ”

5.3. Measurement Units ๐Ÿงฎ

"Line rate" can be measured in terms of "frame rate" ๐Ÿ’–

Frame Rate = Transmit-Clock-Frequency /
   (Frame-Length*8 + Minimum_Gap + Preamble + Start-Frame Delimiter)

Minimum_Gap represents the interframe gap ๐Ÿซง This formula "scales up" or "scales down" to represent 1 GB Ethernet, 10 GB Ethernet, and so on โœจ

Example for 1 GB Ethernet speed with 64-byte frames:

Frame Rate = 1,000,000,000 / (64*8 + 96 + 56 + 8)

           = 1,000,000,000 / 672

           = 1,488,095.2 FPS

Considering the allowance of +/- 100 PPM, a switch may "legally" transmit traffic at a frame rate between 1,487,946.4 FPS and 1,488,244 FPS ๐Ÿ˜ณ Each 1 PPM variation in clock rate will translate to a frame-rate increase or decrease of 1.488 FPS ๐Ÿ“‰๐Ÿ“ˆ

In a production network, it is very unlikely that you would see precise line rate over a very brief period ๐Ÿฅน There is no observable difference between dropping packets at 99% of line rate and 100% of line rate ๐Ÿ™ƒ

Line rate can be measured at 100% of line rate with a -100 PPM adjustment ๐ŸŽฏ

Line rate SHOULD be measured at 99.98% with a 0 PPM adjustment ๐Ÿ’…

The PPM adjustment SHOULD only be used for a line-rate measurement ๐Ÿ”ฅ


6. Buffering ๐Ÿซง

6.1. Buffer ๐Ÿงบ

6.1.1. Definition โœจ

okay so buffer size is the total amount of frame-buffering memory a DUT has available ๐Ÿง  we measure it in B (bytes), KB (kilobytes), MB (megabytes), or GB (gigabytes). when you report it, you also need the frame MTU (Maximum Transmission Unit) you used, plus the CoS (Class of Service) or DSCP (Differentiated Services Code Point) value, because QoS implementations often carve up the buffers ๐Ÿ’… see Section 3 of [RFC8239] for the deets ๐ŸŽ€

Example:

The Buffer Size of the DUT when sending 1518-byte frames is 18 MB.

Port Buffer Size is the amount of buffer for a single ingress port, a single egress port, or a combo of ingress and egress buffering locations for one port ๐ŸŒธ we list all three locations because the DUT's buffering scheme can be unknown or untested, and knowing where the buffer lives helps explain the architecture and the total buffer size ๐Ÿงฉ the Port Buffer Size is an informational value that MAY be provided by the DUT vendor. it is NOT something benchmarking tests. benchmarking uses the Maximum Port Buffer Size or Maximum Buffer Size methodology instead ๐Ÿฆ‹

Maximum Port Buffer Size is usually the same as the Port Buffer Size. but on a "SoC" (switch on chip) architecture, there's a port buffer plus a shared buffer pool that every port can use ๐Ÿ“ so the Maximum Port Buffer Size there is the port buffer plus the largest share of the shared buffer that this port is allowed to take. it's measured in B (bytes), KB (kilobytes), MB (megabytes), or GB (gigabytes), and it needs the frame MTU and the CoS or DSCP bit value set for the test, too ๐Ÿ’œ

Example:

A DUT has been measured to have 3 KB of port buffer for 1518-byte frames, and a total of 4.7 MB of maximum port buffer for 1518-byte frames and a CoS of 0.

Maximum DUT Buffer Size is the total buffer size a DUT can be measured to have ๐Ÿ‘‘ it's most likely different from the Maximum Port Buffer Size, and it can also be different from the sum of the Maximum Port Buffer Sizes. it needs the frame MTU and the CoS or DSCP value set during the test, too โœจ

Example:

A DUT has been measured to have 3 KB of port buffer for 1518-byte frames and a total of 4.7 MB of maximum port buffer for 1518-byte frames.  The DUT has a Maximum Buffer Size of 18 MB at 1500 B and a CoS of 0.

Burst is a fixed number of packets sent over a percentage of line rate for a defined port speed ๐ŸŒˆ the frames are evenly spread across the interval T. a constant, C, can be defined to give the average time between two evenly spaced consecutive packets โญ

Microburst is a kind of burst where packets get dropped even though there's no sustained or noticeable congestion on the link or device ๐Ÿ™ˆ one giveaway is when the burst is NOT evenly spread over T and the gaps are less than the constant C (C = the average time between two evenly spaced consecutive packets). bestie, that's a whole vibe ๐Ÿ’€

Intensity of Microburst is a percentage, from 1 to 100%, showing how strong the microburst is. higher number = more intense ๐Ÿ”ฅ

I=[1-[ (Tp2-Tp1)+(Tp3-Tp2)+....(TpN-Tp(n-1) ] / Sum(packets)]]*100
ok but these definitions aren't here to say what the ideal buffer size is ๐Ÿ™…โ€โ™€๏ธ they're here to explain how to measure it. a bigger buffer is NOT automatically better, and it can cause bufferbloat issues ๐Ÿ˜ญ

6.1.2. Discussion ๐Ÿ’…

when you measure buffering on a DUT, you have to understand what every single port is doing ๐Ÿ‘€ that gives you the data for the total buffering on the switch. the buffer efficiency terms help you figure out the best packet size for the buffer, or how much of the buffer you really get for a specific packet size ๐Ÿง this section doesn't cover how to run the test itself. instead, it explains the buffer definitions and which metrics should be provided for complete data center device-buffering benchmarking ๐Ÿซถ


6.1.3. Measurement Units ๐Ÿ“

when you measure the DUT buffer:

  • The buffer size MUST be measured.
  • The port buffer size MAY be provided for each port.
  • The maximum port buffer size MUST be measured.
  • The maximum DUT buffer size MUST be measured.
  • The intensity of the microburst MAY be mentioned when a microburst test is performed.
  • The CoS or DSCP value set during the test SHOULD be provided.

6.2. Incast ๐Ÿงฒ

6.2.1. Definition ๐Ÿ’–

"Incast" is super common in the data center ๐Ÿข it describes many-to-one or many-to-many traffic patterns. it measures the number of ingress and egress ports and how synchronized they are ๐ŸŽฏ usually that means lots of server ports (the "many") sending traffic to one shared uplink (many-to-one), or to multiple uplinks (many-to-many). the pattern works for any network where lots of incoming ports send traffic to one or a few uplinks ๐ŸŒธ

Synchronous arrival time: when two or more frames of sizes L1 and L2 arrive at their own ingress port, or at multiple ingress ports, and any of their bits overlap in time on the DUT, then L1 and L2 have synchronous arrival times ๐Ÿ’ซ this is called "Incast", whether it's many-to-one (simpler) or many-to-many ๐Ÿฆ‹

Asynchronous arrival time: literally anything that doesn't count as synchronous arrival time ๐Ÿ™ƒ

Percentage of synchronization: how much overlap (in bits) there is between frames of sizes L1, L2..Ln ๐Ÿ“Š

Example:

Two 64-byte frames of length L1 and L2 arrive at ingress port 1 and port 2 of the DUT.  There is an overlap of 6.4 bytes between the two, where the L1 and L2 frames were on their respective ingress ports at the same time.  Therefore, the percentage of synchronization is 10%.

Stateful traffic is packets exchanged with a stateful protocol, like TCP ๐Ÿง 

Stateless traffic is packets exchanged with a stateless protocol, like UDP ๐Ÿชฝ


6.2.2. Discussion ๐Ÿซง

in this scenario, the DUT uses its buffers ๐Ÿงบ with ingress buffering, the ingress port buffers get used along with virtual output queues (when they're available). with egress buffering, the egress buffer of the one outgoing port gets used instead ๐Ÿ”

no matter where the buffer memory sits in the switch architecture, Incast creates buffer utilization ๐Ÿ’ฅ when one or more frames arrive at the DUT with synchronous arrival times, they're considered to be forming an Incast ๐ŸŽ€


6.2.3. Measurement Units ๐Ÿ“

It is a MUST to measure the number of ingress and egress ports.

It is a MUST to have a non-null percentage of synchronization, which MUST be specified.


7. Application Throughput: Data Center Goodput ๐Ÿ›๏ธ

7.1. Definition ๐ŸŒท

in data center networking, a balanced network means you get maximal throughput with minimal loss at any given time ๐ŸŽฏ this is captured by Goodput [TCP-INCAST]. Goodput is the application-level throughput ๐Ÿง for standard TCP applications, even a very small loss can totally tank application throughput ๐Ÿ˜ญ [RFC2647] defines Goodput, and the definition in this document is a variant of that one ๐Ÿ’…

Goodput is the number of bits per unit of time forwarded to the correct destination interface of the DUT, minus any bits retransmitted โœจ


7.2. Discussion ๐Ÿ’ฌ

in data center benchmarking, Goodput is a value that SHOULD be measured ๐Ÿ“ˆ it gives you a realistic idea of how much of the available bandwidth is actually being used. the goal in data center environments is to maximize Goodput while minimizing loss ๐Ÿซถ


7.3. Measurement Units ๐Ÿงฎ

The Goodput, G, is then measured by the following formula:

G = (S/F) x V bytes per second
  • S represents the payload bytes, not including packet or TCP headers.
  • F is the frame size.
  • V is the speed of the media in bytes per second.

Example: A TCP file transfer over HTTP on 10 GB/s media.

The file cannot be transferred over Ethernet as a single continuous stream.  It must be broken down into individual frames of 1500 B when the standard MTU is used.  Each packet requires 20 B of IP header information and 20 B of TCP header information; therefore, 1460 B are available per packet for the file transfer.  Linux-based systems are further limited to 1448 B, as they also carry a 12 B timestamp.  Finally, in this example the date is transmitted over Ethernet, which adds 26 B of overhead per packet to 1500 B, increasing it to 1526 B.
G = 1460/1526 x 10 Gbit/s, which is 9.567 Gbit/s or 1.196 GB/s.
Please note: This example does not take into consideration the additional Ethernet overhead, such as the interframe gap (a minimum of 96 bit times), nor does it account for collisions (which have a variable impact, depending on the network load).

when you do Goodput measurements, please document these in addition to the items listed in Section 4.1:

  • The TCP stack used.
  • OS versions.
  • Network Interface Card (NIC) firmware version and model.

for example, Windows TCP stacks and different Linux versions can change TCP-based test results ๐ŸชŸ๐Ÿง


8. Security Considerations ๐Ÿ”’

Benchmarking activities as described in this memo are limited to technology characterization using controlled stimuli in a laboratory environment, with dedicated address space and the constraints specified in the sections above.

The benchmarking network topology will be an independent test setup and MUST NOT be connected to devices that may forward the test traffic into a production network or misroute traffic to the test management network. ๐Ÿšจ this is the big one, don't skip it ๐Ÿ˜ค

Further, benchmarking is performed on a "black-box" basis, relying solely on measurements observable external to the DUT ๐Ÿ–ค

Special capabilities SHOULD NOT exist in the DUT specifically for benchmarking purposes. Any implications for network security arising from the DUT SHOULD be identical in the lab and in production networks ๐Ÿ›ก๏ธ


9. IANA Considerations ๐Ÿงš

This document does not require any IANA actions.


10. References ๐Ÿ“š

10.1. Normative References ๐Ÿ’–

okay bestie, these are the sources the spec leans on hardest ๐Ÿ’…

[RFC1242] Bradner, S., "Benchmarking Terminology for Network Interconnection Devices", RFC 1242, DOI 10.17487/RFC1242, July 1991, https://www.rfc-editor.org/info/rfc1242.

[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", BCP 14, RFC 2119, DOI 10.17487/RFC2119, March 1997, https://www.rfc-editor.org/info/rfc2119.

[RFC2544] Bradner, S. and J. McQuaid, "Benchmarking Methodology for Network Interconnect Devices", RFC 2544, DOI 10.17487/RFC2544, March 1999, https://www.rfc-editor.org/info/rfc2544.

[RFC5481] Morton, A. and B. Claise, "Packet Delay Variation Applicability Statement", RFC 5481, DOI 10.17487/RFC5481, March 2009, https://www.rfc-editor.org/info/rfc5481.

[RFC8174] Leiba, B., "Ambiguity of Uppercase vs Lowercase in RFC 2119 Key Words", BCP 14, RFC 8174, DOI 10.17487/RFC8174, May 2017, https://www.rfc-editor.org/info/rfc8174.

[RFC8239] Avramov, L. and J. Rapp, "Data Center Benchmarking Methodology", RFC 8239, DOI 10.17487/RFC8239, August 2017, https://www.rfc-editor.org/info/rfc8239.

10.2. Informative References ๐Ÿฆ‹

these ones are the background reading. super useful, not strictly required ๐Ÿค“

[RFC2432] Dubray, K., "Terminology for IP Multicast Benchmarking", RFC 2432, DOI 10.17487/RFC2432, October 1998, https://www.rfc-editor.org/info/rfc2432.

[RFC2647] Newman, D., "Benchmarking Terminology for Firewall Performance", RFC 2647, DOI 10.17487/RFC2647, August 1999, https://www.rfc-editor.org/info/rfc2647.

[RFC2889] Mandeville, R. and J. Perser, "Benchmarking Methodology for LAN Switching Devices", RFC 2889, DOI 10.17487/RFC2889, August 2000, https://www.rfc-editor.org/info/rfc2889.

[RFC3918] Stopp, D. and B. Hickman, "Methodology for IP Multicast Benchmarking", RFC 3918, DOI 10.17487/RFC3918, October 2004, https://www.rfc-editor.org/info/rfc3918.

[TCP-INCAST] Chen, Y., Griffith, R., Zats, D., Joseph, A., and R. Katz, "Understanding TCP Incast and Its Implications for Big Data Workloads", April 2012, http://yanpeichen.com/professional/usenixLoginIncastReady.pdf.

Acknowledgments ๐Ÿซถ

the authors want to thank Al Morton, Scott Bradner, Ian Cox, and Tim Stevenson for their reviews and feedback ๐ŸŒธ the real MVPs ๐Ÿ‘‘

Authors' Addresses ๐Ÿงš

Lucien Avramov
Google
1600 Amphitheatre Parkway
Mountain View, CA  94043
United States of America

Email: lucien.avramov@gmail.com


Jacob Rapp
VMware
3401 Hillview Ave.
Palo Alto, CA  94304
United States of America

Email: jhrapp@gmail.com