SBD(8)

πŸ’… SBD(8) β€” STONITH Block Device

okay bestie, welcome to sbd(8), the STONITH Block Device page. yes that's a whole section-8 manual page. no, it's not scary. it's actually kind of iconic once you get it. let's go 🫢

✨ NAME ✨

sbd β€” the STONITH Block Device daemon. that's it, that's the name. she's a daemon. she does block devices. slay. πŸ’…

✨ SYNOPSIS ✨

sbd <-d /dev/...> [options] "command"

✨ SUMMARY ✨

okay so here's the whole vibe: sbd gives you a node fencing mechanism β€” yeah, STONITH, "Shoot the other node in the head", real dramatic name, love that for us πŸ’€ β€” for Pacemaker-based clusters. how? by exchanging messages over shared block storage. think SAN, iSCSI, FCoE, that whole friend group. this isolates the fencing mechanism from firmware version changes and from depending on specific firmware controllers, and it can be used as a STONITH mechanism in all configurations that have reliable shared storage. no cap 🌸

and here's the plot twist: sbd can also be used with no shared storage at all. in that mode, the watchdog device resets the node if it loses quorum, if any monitored daemon is lost and not recovered, or if Pacemaker decides the node needs fencing. main character energy honestly πŸ‘‘

the sbd binary is literally two things at once: it implements both the daemon that watches the message slots and the management tool for interacting with the block storage device(s). which mode you get is decided by the "command" parameter β€” and some of these modes take extra parameters. multitasking queen πŸŽ€

to use SBD with shared storage, it's a three-step situation:

  1. "create" the messaging layout on one to three block devices.
  2. configure /etc/sysconfig/sbd to list those devices (and possibly adjust other options), then restart the cluster stack on each node so that "sbd" actually gets started.
  3. configure the "external/sbd" fencing resource in the Pacemaker CIB.

each of these steps is documented in more detail below the description of the command options. iykyk ✨

heads up: "sbd" can only be used as root. like, that's not a suggestion. that's the rule. πŸ”₯

🌈 GENERAL OPTIONS 🌈

  • -d /dev/... β€” specify the block device(s) to be used. got more than one? specify this option up to three times. this parameter is mandatory for all modes, because SBD always needs a block device to interact with. literally always. she's not low-maintenance like that 😭

this man page uses /dev/sda1, /dev/sdb1, and /dev/sdc1 as example device names for brevity. but in your production environment you should instead always refer to them by using the long, stable device name (e.g., /dev/disk/by-id/dm-uuid-part1-mpath-3600508b400105b5a0001500000250000). yes that whole thing. write it down bestie πŸ“

  • -v | -vv | -vvv β€” enable verbose | debug | debug-library logging (optional). more v's, more yapping πŸ¦‹
  • -h β€” display a concise summary of "sbd" options. the tl;dr of the tl;dr.
  • -n node β€” set the local node name; defaults to uname -n. this should not need to be set. like genuinely. leave it alone πŸ™ˆ
  • -R β€” do not enable realtime priority. by default "sbd" runs at realtime priority, locks itself into memory, and also acquires highest IO priority to protect itself against interference from other processes on the system.
warning: this is a debugging-only option. only. debugging. only. okay? πŸ’€
  • -I N β€” async IO timeout. defaults to 3 seconds, optional. you should not need to adjust this unless your IO setup is really very slow 🐒

(in daemon mode, the watchdog is refreshed when the majority of devices could be read within this time.)


✨ create ✨

example usage, look at her go:

sbd -d /dev/sdc2 -d /dev/sdd3 create

if you specify the create command, sbd will write a metadata header to the device(s) specified and also initialize the messaging slots for up to 255 nodes. 255 besties. a whole group chat πŸ‘‘

WARNING, genuinely, read this one: this command will not prompt for confirmation. roughly the first megabyte of the specified block device(s) will be overwritten immediately and without backup. no take-backs, no undo, no "wait I didn't mean to" 😭😭

this command accepts a few options to adjust the default timings that are written to the metadata (to ensure they are identical across all nodes accessing the device):

  • -1 N β€” set watchdog timeout to N seconds. this depends mostly on your storage latency; the majority of devices must be successfully read within this time, or else the node will self-fence. self-fence. as in, it takes itself out. dramatic but necessary πŸ’…

if your sbd device(s) reside on a multipath setup or iSCSI, this should be the time required to detect a path failure. you may be able to reduce this if your device outages are independent, or if you are using the Pacemaker integration.

  • -2 N β€” set slot allocation timeout to N seconds. you should not need to tune this. like, at all. leave her be πŸŽ€
  • -3 N β€” set daemon loop timeout to N seconds. you should not need to tune this either. see above. same energy.
  • -4 N β€” set msgwait timeout to N seconds. this should be twice the watchdog timeout. this is the time after which a message written to a node's slot will be considered delivered. (or long enough for the node to detect that it needed to self-fence.) so yeah, kind of a big deal ⭐

this also affects the stonith-timeout in Pacemaker's CIB; see below.


✨ list ✨

example usage, cute little output and everything:

# sbd -d /dev/sda1 list
0       hex-0   clear
1       hex-7   clear
2       hex-9   clear

list all allocated slots on device, and messages. you should see all cluster nodes that have ever been started against this device. nodes that are currently running should have a clear state; nodes that have been fenced, but not yet restarted, will show the appropriate fencing message. it's giving receipts πŸ’…πŸŒΈ


✨ dump ✨

example usage:

# sbd -d /dev/sda1 dump
==Dumping header on disk /dev/sda1
Header version     : 2
Number of slots    : 255
Sector size        : 512
Timeout (watchdog) : 15
Timeout (allocate) : 2
Timeout (loop)     : 1
Timeout (msgwait)  : 30
==Header on disk /dev/sda1 is dumped

dump meta-data header from device. that's the whole thing. she dumps, she's done, she leaves πŸ¦‹


πŸ‘‘ watch πŸ‘‘

example usage:

sbd -d /dev/sdc2 -d /dev/sdd3 -P watch

this command will make "sbd" start in daemon mode. she will constantly monitor the message slot of the local node for incoming messages, reachability, and optionally take Pacemaker's state into account. eyes on everything. always πŸ‘€

important: "sbd" must be started on boot before the cluster stack! see below for enabling this according to your boot environment. order matters, bestie. it's not a vibe thing, it's a literal requirement πŸ”₯

the options for this mode are rarely specified directly on the commandline directly, but most frequently set via /etc/sysconfig/sbd. that's home base 🏠

it also constantly monitors connectivity to the storage device, and self-fences in case the partition becomes unreachable, guaranteeing that it does not disconnect from fencing messages. she would never ghost a fencing message. never πŸ’œ

a node slot is automatically allocated on the device(s) the first time the daemon starts watching the device; hence, manual allocation is not usually required. let her handle it ✨

if a watchdog is used together with the "sbd" as is strongly recommended, the watchdog is activated at initial start of the sbd daemon. the watchdog is refreshed every time the majority of SBD devices has been successfully read. using a watchdog provides additional protection against "sbd" crashing. we love a backup plan 🫢

if the Pacemaker integration is activated, "sbd" will not self-fence if device majority is lost, if:

  1. the partition the node is in is still quorate according to the CIB;
  2. it is still quorate according to Corosync's node count;
  3. the node itself is considered online and healthy by Pacemaker.

this allows "sbd" to survive temporary outages of the majority of devices. however β€” and this is the big however β€” while the cluster is in such a degraded state, it can neither successfully fence nor be shutdown cleanly (as taking the cluster below the quorum threshold will immediately cause all remaining nodes to self-fence). in short, it will not tolerate any further faults. so please repair the system before continuing. like actually please πŸ˜­πŸ’€

there is one "sbd" process that acts as a master to which all watchers report; one per device to monitor the node's slot; and, optionally, one that handles the Pacemaker integration. a whole little family πŸŽ€

  • -W β€” enable or disable use of the system watchdog to protect against the sbd processes failing and the node being left in an undefined state. specify this once to enable, twice to disable.

defaults to enabled. so she's on unless you say otherwise πŸ’…

  • -w /dev/watchdog β€” this can be used to override the default watchdog device used and should not usually be necessary. like, only if you're being fancy. or if your watchdog lives somewhere else 🐢
  • -p /run/sbd.pid β€” this option can be used to specify a pidfile for the main sbd process.
  • -F N β€” number of failures before a failing servant process will not be restarted immediately until the dampening delay has expired. if set to zero, servants will be restarted immediately and indefinitely. if set to one, a failed servant will be restarted once every -t seconds. if set to a different value, the servant will be restarted that many times within the dampening period and then delay.

defaults to 1.

  • -t N β€” dampening delay before faulty servants are restarted. combined with -F 1, the most logical way to tune the restart frequency of servant processes. default is 5 seconds.

if set to zero, processes will be restarted indefinitely and immediately. no chill. zero chill. πŸ”₯

  • -P β€” enable Pacemaker integration which checks Pacemaker quorum and node health. specify this once to enable, twice to disable.

defaults to enabled.

  • -S N β€” set the start mode. (defaults to 0.)

if this is set to zero, sbd will always start up unconditionally, regardless of whether the node was previously fenced or not. she's trusting like that 🌸

if set to one, sbd will only start if the node was previously shutdown cleanly (as indicated by an exit request message in the slot), or if the slot is empty. a reset, crashdump, or power-off request in any slot will halt the start up. πŸ›‘

this is useful to prevent nodes from rejoining if they were faulty. the node must be manually "unfenced" by sending an empty message to it:

sbd -d /dev/sda1 message node1 clear
  • -s N β€” set the start-up wait time for devices. (defaults to 120.)

dynamic block devices such as iSCSI might not be fully initialized and present yet. this allows one to set a timeout for waiting for devices to appear on start-up. if set to 0, start-up will be aborted immediately if no devices are available. no patience. zero patience. ⏰

  • -Z β€” enable trace mode.
WARNING: this is unsafe for production, use at your own risk! specifying this once will turn all reboots or power-offs, be they caused by self-fence decisions or messages, into a crashdump. specifying this twice will just log them but not continue running. so like… it's a testing thing. not a production thing. fr fr πŸ’€
  • -T β€” by default, the daemon will set the watchdog timeout as specified in the device metadata. however, this does not work for every watchdog device. in this case, you must manually ensure that the watchdog timeout used by the system correctly matches the SBD settings, and then specify this option to allow "sbd" to continue with start-up. manual vibes only ✨
  • -5 N β€” this is your "hey bestie, your watchdog timeout is kinda short" alarm 🚨. If the time interval for tickling the watchdog goes over this many seconds, you get a warning. Why is that lowkey genius? Because when the watchdog expires the node literally can't log it β€” it reboots instantly, no chance to write logs to disk 😭. So this warning is the only clue you get that your watchdog timeout is too tight for the IO load your system is actually carrying. Default is about 3/5 of the watchdog timeout; set it to zero to disable. ✨
  • -C N β€” the watchdog timeout to set before crashdumping 🩹. If SBD is configured to crashdump instead of reboot β€” whether through the trace mode settings or through the external/sbd fencing agent's parameter β€” SBD will adjust the watchdog timeout to this setting before it triggers the dump. Because otherwise? The watchdog could fire mid-dump and your crashdump would never get written. Iconic disaster. Set to zero (= default) to disable. πŸ’…
  • -r N β€” the actions that get executed when the watchers don't timely report to the sbd master process, or when one of the watchers detects that the master process has died πŸ’€. Set timeout-action to a comma-separated combination of noflush|flush plus reboot|crashdump|off. If you only give one of the two, the other one stays at the default. Heads up: this does not affect actions like off, crashdump, reboot explicitly triggered via message slots. And it also does not configure the action a watchdog would trigger should it run off (there's no generic interface for that, sorry bestie 🫢). Defaults to flush,reboot.

πŸŽ€ allocate

Example usage, bestie:

sbd -d /dev/sda1 allocate node1

This explicitly allocates a slot for the specified node name. Honestly? You should rarely need this, because every node automatically allocates itself a slot the first time it starts up on watch mode. It's giving "backup plan energy". πŸ‘‘

πŸ’Œ message

Example usage:

sbd -d /dev/sda1 message node1 test

Writes the specified message to that node's slot. Again, this is rarely done directly β€” it's usually abstracted via the "external/sbd" fencing agent configured as a cluster resource. iykyk.

Supported message types are:

  • test β€” only generates a log message on the receiving node, and you can use it to check whether SBD is actually seeing the device. ⚠️ Note that this could overwrite a fencing request sent by the cluster, so don't use it during production, fr fr.
  • reset β€” resets the target upon receipt of this message.
  • off β€” powers off the target. πŸ”Œ
  • crashdump β€” causes the target node to crashdump.
  • exit β€” this makes the "sbd" daemon exit cleanly on the target. Do not send this one manually β€” it's handled properly during shutdown of the cluster stack. Manually stopping the daemon means the node is unprotected! 😱
  • clear β€” this message indicates that no real message has been sent to the node. Don't set this manually either; "sbd" clears the message slot automatically during start-up, and setting it by hand could overwrite a fencing message from the cluster. πŸ™ˆ

πŸ• query-watchdog

Example usage:

sbd query-watchdog

Checks for available watchdog devices and prints some info. Cute, right? 🌸

Warning: this command will arm the watchdog during the query, and if your watchdog refuses disarming (for example, if its kernel module has the 'nowayout' parameter set) this will reset your system. πŸ’€ Not a drill, bestie.

πŸ§ͺ test-watchdog

Example usage:

sbd test-watchdog [-w /dev/watchdog3]

Tests the specified watchdog device (/dev/watchdog by default).

Warning: this command will arm the watchdog and have your system reset in case your watchdog is working properly! 😭 If it's issued from an interactive session, it will prompt you for confirmation first, which is honestly the bare minimum.

πŸ› οΈ Base system configuration

βš™οΈ Configure a watchdog

It is highly recommended that you configure your Linux system to load a watchdog driver with hardware assistance (as is available on most modern systems), such as hpwdt, iTCO_wdt, or others. As a fall-back, you can use the softdog module. 🫢

No other software must access the watchdog timer β€” it can only be accessed by one process at any given time. Some hardware vendors ship systems management software that uses the watchdog for system resets (f.e. the HP ASR daemon). Such software has to be disabled if the watchdog is to be used by SBD. Periodt. πŸ’…

πŸ’Ύ Choosing and initializing the block device(s)

First, you have to decide if you want to use one, two, or three devices.

If you're using multiple ones, they should reside on independent storage setups. Putting all three of them on the same logical unit, for example, would not provide any additional redundancy. That's giving "three copies of the same vibe check" β€” pointless. πŸ’€

The SBD device can be connected via Fibre Channel, Fibre Channel over Ethernet, or even iSCSI. Thus, an iSCSI target can become a sort-of network-based quorum server; the advantage is that it does not require a smart host at your third location, just block storage. Kinda iconic tbh. ✨

The SBD partitions themselves must not be mirrored (via MD, DRBD, or the storage layer itself), since this could result in a split-mirror scenario. Nor can they reside on cLVM2 volume groups, since they must be accessed by the cluster stack before it has started the cLVM2 daemons; hence, these should be either raw partitions or logical units on (multipath) storage. πŸŽ€

The block device(s) must be accessible from all nodes. (While it is not necessary that they share the same path name on all nodes, this is considered a very good idea.) πŸ‘‘

SBD will only use about one megabyte per device, so you can easily create a small partition, or very small logical units. (The size of the SBD device depends on the block size of the underlying device. Thus, 1MB is fine on plain SCSI devices and SAN storage with 512 byte blocks. On the IBM s390x architecture in particular, disks default to 4k blocks, and thus require roughly 4MB.) πŸ“

The number of devices will affect the operation of SBD as follows:

1️⃣ One device

In its most simple implementation, you use one device only. This is appropriate for clusters where all your data is on the same shared storage (with internal redundancy) anyway; the SBD device does not introduce an additional single point of failure then. 🌈

If the SBD device is not accessible, the daemon will fail to start and inhibit startup of cluster services.

2️⃣ Two devices

This configuration is a trade-off, primarily aimed at environments where host-based mirroring is used, but no third storage device is available.

SBD will not commit suicide if it loses access to one mirror leg; this allows the cluster to continue to function even in the face of one outage. 🫢

However, SBD will not fence the other side while only one mirror leg is available, since it does not have enough knowledge to detect an asymmetric split of the storage. So it will not be able to automatically tolerate a second failure while one of the storage arrays is down. (Though you can use the appropriate crm command to acknowledge the fence manually.) πŸ™ˆ

It will not start unless both devices are accessible on boot.

3️⃣ Three devices

In this most reliable and recommended configuration, SBD will only self-fence if more than one device is lost; hence, this configuration is resilient against temporary single device outages (be it due to failures or maintenance). Fencing messages can still be successfully relayed if at least two devices remain accessible. πŸ”₯

This configuration is appropriate for more complex scenarios where storage is not confined to a single array. For example, host-based mirroring solutions could have one SBD per mirror leg (not mirrored itself), and an additional tie-breaker on iSCSI. πŸ‘‘

It will only start if at least two devices are accessible on boot.

After you have chosen the devices and created the appropriate partitions and perhaps multipath alias names to ease management, use the "sbd create" command described above to initialize the SBD metadata on them. πŸŽ€

πŸ”— Sharing the block device(s) between multiple clusters

It is possible to share the block devices between multiple clusters, provided the total number of nodes accessing them does not exceed 255 nodes, and they all must share the same SBD timeouts (since these are part of the metadata).

If you are using multiple devices this can reduce the setup overhead required. However, you should not share devices between clusters in different security domains. πŸ”’

πŸš€ Configure SBD to start on boot

On systems using "sysvinit", the "openais" or "corosync" system start-up scripts must handle starting or stopping "sbd" as required before starting the rest of the cluster stack.

For "systemd", sbd simply has to be enabled using

systemctl enable sbd.service

The daemon is brought online on each node before corosync and Pacemaker are started, and terminated only after all other cluster components have been shut down β€” ensuring that cluster resources are never activated without SBD supervision. Literally the main character of boot order. πŸ‘‘βœ¨

πŸ“ Configuration via sysconfig

The system instance of "sbd" is configured via /etc/sysconfig/sbd. In this file, you must specify the device(s) used, as well as any options to pass to the daemon:

SBD_DEVICE="/dev/sda1;/dev/sdb1;/dev/sdc1"
SBD_PACEMAKER="true"

"sbd" will fail to start if no "SBD_DEVICE" is specified. See the installed template or section for configuration via environment for more options that can be configured here. In general, configuration done via parameters takes precedence over the configuration from the configuration file. πŸ’…

🌿 Configuration via environment

SBD_DEVICE

Allows "string" defaulting to ""

SBD_DEVICE specifies the devices to use for exchanging sbd messages and to monitor. If specifying more than one path, use ";" as separator. πŸ”—

SBD_PACEMAKER

Allows "yesno" defaulting to "yes"

Whether to enable the pacemaker integration.

SBD_STARTMODE

Allows "always / clean" defaulting to "always"

Specify the start mode for sbd. Setting this to "clean" will only allow sbd to start if it was not previously fenced. See the -S option in the man page. πŸ‘€

SBD_DELAY_START

Allows "yesno / integer" defaulting to "no"

Whether to delay after starting sbd on boot for "msgwait" seconds. This may be necessary if your cluster nodes reboot so fast that the other nodes are still waiting in the fence acknowledgement phase. This is an occasional issue with virtual machines. πŸ–₯οΈπŸ’¨

This can also be enabled by being set to a specific delay value, in seconds. Sometimes a longer delay than the default, "msgwait", is needed, for example in the cases where it's considered to be safer to wait longer than: corosync token timeout + consensus timeout + pcmk_delay_max + msgwait

Be aware that the special value "1" means "yes" rather than 1s. πŸ’€ Not me almost getting caught by that one.

Consider that you might have to adapt the startup-timeout accordingly if the default isn't sufficient. (TimeoutStartSec for systemd)

Heads up, bestie: This option may be ignored at a later point, once pacemaker handles this case better.
  • SBD_WATCHDOG_DEV β€” Allows "string", defaulting to "/dev/watchdog". Watchdog device to use. If set to /dev/null, no watchdog device will be used.
  • SBD_WATCHDOG_TIMEOUT β€” Allows "integer", defaulting to 5. How long, in seconds, the watchdog will wait before panicking the node if no-one tickles it.

This depends mostly on your storage latency; the majority of devices must be successfully read within this time, or else the node will self-fence.

If your sbd device(s) reside on a multipath setup or iSCSI, this should be the time required to detect a path failure.

Be aware: watchdog timeout set in the on-disk metadata takes precedence. πŸ‘‘
  • SBD_TIMEOUT_ACTION β€” Allows "string", defaulting to "flush,reboot". Actions to be executed when the watchers don't timely report to the sbd master process or one of the watchers detects that the master process has died.

Set timeout-action to a comma-separated combination of noflush|flush plus reboot|crashdump|off. If just one of both is given, the other stays at the default.

This doesn't affect actions like off, crashdump, reboot explicitly triggered via message slots. And it also does not configure the action a watchdog would trigger should it run off (there is no generic interface).

  • SBD_MOVE_TO_ROOT_CGROUP β€” Allows "yesno / auto", defaulting to "auto". If CPUAccounting is enabled, default is not to assign any RT-budget to the system.slice which prevents sbd from running RR-scheduled.

One way to escape that issue is to move sbd-processes from the slice they were originally started to root-slice. Of course starting sbd in a certain slice might be intentional. Thus in auto-mode sbd will check if the slice has RT-budget assigned. If that is the case, sbd will stay in that slice while it will be moved to root-slice otherwise.

  • SBD_SYNC_RESOURCE_STARTUP β€” Allows "yesno", defaulting to "yes". If resource startup syncing is enabled then pacemakerd is gonna wait to be pinged via IPC before it starts resources. On shutdown pacemakerd is going to wait in a state where it has cleanly shutdown resources till sbd fetches that state.

The default is set when building SBD and Pacemaker from source. Going for 'no' is safer if it can't be assured that SBD and Pacemaker installed do both support the synchronization feature. When going with 'yes' β€” also using package dependencies to assure SBD & Pacemaker both support the synchronization feature and are assuming the same default β€” an SBD configuration inherited via an upgrade doesn't have to be altered to still benefit from the new feature.

  • SBD_OPTS β€” Allows "string", defaulting to "". Additional options for starting sbd.

πŸ§ͺ Testing the sbd installation πŸ§ͺ

After a restart of the cluster stack on this node, you can now try sending a test message to it as root, from this or any other node:

sbd -d /dev/sda1 message node1 test

The node will acknowledge the receipt of the message in the system logs:

Aug 29 14:10:00 node1 sbd: [13412]: info: Received command test from node2

This confirms that SBD is indeed up and running on the node, and that it is ready to receive messages. Slay. ✨

Make sure that /etc/sysconfig/sbd is identical on all cluster nodes, and that all cluster nodes are running the daemon.


πŸ’– Pacemaker CIB integration πŸ’–

🧚 Fencing resource 🧚

Pacemaker can only interact with SBD to issue a node fence if there is a configure fencing resource. This should be a primitive, not a clone, as follows:

primitive fencing-sbd stonith:external/sbd \
        params pcmk_delay_max=30

This will automatically use the same devices as configured in /etc/sysconfig/sbd.

While you should not configure this as a clone (as Pacemaker will register the fencing device on each node automatically), the pcmk_delay_max setting enables random fencing delay which ensures, in a scenario where a split-brain scenario did occur in a two node cluster, that one of the nodes has a better chance to survive to avoid double fencing. Iconic behavior, honestly.

SBD also supports turning the reset request into a crash request, which may be helpful for debugging if you have kernel crashdumping configured; then, every fence request will cause the node to dump core. You can enable this via the crashdump="true" parameter on the fencing resource. This is not recommended for production use, but only for debugging phases. 🫢

🌈 General cluster properties 🌈

You must also enable STONITH in general, and set the STONITH timeout to be at least twice the msgwait timeout you have configured, to allow enough time for the fencing message to be delivered. If your msgwait timeout is 60 seconds, this is a possible configuration:

property stonith-enabled="true"
property stonith-timeout="120s"
Caution ⚠️: if stonith-timeout is too low for msgwait and the system overhead, sbd will never be able to successfully complete a fence request. This will create a fencing loop. Not the vibe.

Note that the sbd fencing agent will try to detect this and automatically extend the stonith-timeout setting to a reasonable value, on the assumption that sbd modifying your configuration is preferable to not fencing.


πŸ‘‘ Management tasks πŸ‘‘

🩹 Recovering from temporary SBD device outage 🩹

If you have multiple devices, failure of a single device is not immediately fatal. sbd will retry to restart the monitor for the device every 5 seconds by default. However, you can tune this via the options to the watch command.

In case you wish to immediately force a restart of all currently disabled monitor processes, you can send a SIGUSR1 to the SBD inquisitor process. Little signal, big main-character energy. πŸ’…


πŸ“œ LICENSE πŸ“œ

Copyright (C) 2008-2013 Lars Marowsky-Bree

This program is free software; you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation; either version 2 of the License, or (at your option) any later version.

This software is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details.

For details see the GNU General Public License at http://www.gnu.org/licenses/gpl-2.0.html (version 2) and/or http://www.gnu.org/licenses/gpl.html (the newest as per "any later").


That’s the whole SBD(8) manual, bestie: source/version SBD, dated 2025-02-12, in all its SBD(8) glory. Go keep your cluster alive πŸ’–βœ¨