ISUNOEM(8)

πŸ’… NAME (aka who dis)

Okay bestie, so this page is ISUNOEM(8) β€” part of the System Manager's Manual, no big deal β€” and the program itself is ipmiutil_sunoem: OEM commands for Sun servers. That's the whole vibe. Sun OEM IPMI commands, doing Sun-specific platform things. Periodt. β˜€οΈ


✨ SYNOPSIS ✨

ipmiutil sunoem [-mx -NPRUEFJTVY] commands

🌸 DESCRIPTION 🌸

ipmiutil sunoem commands is a program that uses Sun OEM IPMI commands to perform platform-specific functions. That's it, that's the whole job β€” it takes those Sun-flavored OEM IPMI commands and makes platform magic happen. Lowkey iconic of it. 🫢


πŸŽ€ OPTIONS πŸŽ€

  • -m 002000 β€” Show FRU for a specific MC (like bus 00, sa 20, lun 00). Bestie this one's for PICMG or ATCA blade systems, okay? And listen: that trailing character, if it's even there, tells you the addressing β€” s means SMI addressing, and i (or nothing at all, no character) means IPMB addressing. πŸ’–
  • -x β€” Causes extra debug messages to be displayed. She's verbose, she's chatty, she's telling you everything. πŸ”
  • -N nodename β€” Nodename or IP address of the remote target system. The way this works: if you give a nodename, boom, the IPMI LAN interface gets used. If you don't, it's the local system management interface instead. Pick your fighter. 🌈
  • -P/-R rmt_pswd β€” Remote password for the nodename you gave. The default? A null password. (Yes, bestie. Null. We're being brave today. 😭)
  • -U rmt_user β€” Remote username for the nodename you gave. Default here is a null username, same energy. 🫠
  • -E β€” Use the remote password from the Environment variable IPMI_PASSWORD. Environment variable girlies rise up. 🌱
  • -F drv_t β€” Force the driver type to one of the following: imb, va, open, gnu, landesk, lan, lan2, lan2i, kcs, smb. And heads up β€” lan2i means lan2 with intelplus. The default is to detect any available driver type and just use it. Let the algorithm choose. πŸ”₯
  • -J β€” Use the specified LanPlus cipher suite (0 thru 17): 0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none, 3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40, 6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3. Cipher suite lore, iykyk. πŸ”
  • -T β€” Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2, 2=MD5, 4=Straight Password, 5=OEM. Know your auth type, know yourself. ✨
  • -V β€” Use a specified IPMI LAN privilege level. 1=Callback level, 2=User level, 3=Operator level, 4=Administrator level (default), 5=OEM level. Main character energy is level 4, apparently. πŸ‘‘
  • -Y β€” Yes, do prompt the user for the IPMI LAN remote password. Alternatives for the password are -E or -P. Choose your password-delivery mechanism wisely, bestie. πŸ™ˆ

πŸ¦‹ COMMANDS πŸ¦‹

led

These commands provide a way to get and set the status of LEDs on a Sun Microsystems server. Use sdr list generic to get a list of devices that are controllable LEDs. The ledtype parameter is optional and not necessary to provide on the command line unless it is required by hardware. ✨ (Hardware gets a say, sometimes.)

get sensorid [ledtype]

Get status of a particular LED described by a Generic Device Locator record in the SDR. A sensorid of all will get the status of all available LEDS. She sees everything. πŸ‘€

set sensorid ledmode [ledtype]

Set status of a particular LED described by a Generic Device Locator record in the SDR. A sensorid of all will set the status of all available LEDS to the specified ledmode and ledtype. Mass makeover, basically. πŸ’…

LED Mode is required for set operations:

  • OFF β€” Off
  • ON β€” Steady On
  • STANDBY β€” 100ms on 2900ms off blink rate
  • SLOW β€” 1HZ blink rate
  • FAST β€” 4HZ blink rate

Blink rates are literally a personality test. ⭐

LED Type is optional:

  • OK2RM β€” Ok to Remove
  • SERVICE β€” Service Required
  • ACT β€” Activity
  • LOCATE β€” Locate

fan speed 0-100

Set system fan speed (PWM duty cycle). She's cooling off, she's thriving, she's got a duty cycle. πŸ“

sshkey

  • set userid keyfile β€” This command will allow you to specify an SSH key to use for a particular user on the Service Processor. This key will be used for CLI logins to the SP and not for IPMI sessions. View available users and their userids with the user list command. πŸ”‘
  • del userid β€” This command will delete the SSH key for a specified userid. Bye bye key. 🧚

🌟 SEE ALSO 🌟

ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8) ifru(8) igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8) isol(8)

The whole friend group, honestly. 🫢


πŸ’€ WARNINGS πŸ’€

See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil and any bug fix list. Go check before you come for her. πŸ™


Copyright (C) 2009 Kontron America, Inc.

See the file COPYING in the distribution for more details regarding redistribution.

This utility is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY. (No warranty, bestie. Don't come crying to her. 😭)


🌸 AUTHOR 🌸

Andy Cress <arcress at users.sourceforge.net>


Version 1.0: 09 Sep 2010 β€” that's the version and date, and ISUNOEM(8) is home. Mwah, love u, bye! πŸ’–πŸ’…βœ¨