ISMCOEM(8)

πŸŽ€ NAME πŸŽ€

okay bestie, this is ISMCOEM(8) from the System Manager's Manual. The page is for ipmiutil_smcoem β€” OEM commands for SuperMicro servers. yep, that's the whole name vibe πŸ’…

✨ SYNOPSIS ✨

ipmiutil smcoem [-mx -NPRUEFJTVY] commands

πŸ¦‹ DESCRIPTION πŸ¦‹

ipmiutil smcoem is a function that uses SuperMicro OEM IPMI commands to perform platform-specific functions. that's it, that's the assignment ✨

πŸ’… OPTIONS πŸ’…

  • -m 002000 β€” Show FRU for a specific MC (e.g. bus 00, sa 20, lun 00). This could be used for PICMG or ATCA blade systems. The trailing character, if present, indicates SMI addressing if 's', or IPMB addressing if 'i' or not present. 🫢
  • -x β€” Causes extra debug messages to be displayed. debug girlie mode πŸ”
  • -N nodename β€” Nodename or IP address of the remote target system. If a nodename is specified, IPMI LAN interface is used. Otherwise the local system management interface is used. remote vibes only when you name it 🌐
  • -P/-R rmt_pswd β€” Remote password for the nodename given. The default is a null password. πŸ”
  • -U rmt_user β€” Remote username for the nodename given. The default is a null username. πŸ‘€
  • -E β€” Use the remote password from Environment variable IPMI_PASSWORD. env var slay 🌱
  • -F drv_t β€” Force the driver type to one of these: imb, va, open, gnu, landesk, lan, lan2, lan2i, kcs, smb. Note that lan2i means lan2 with intelplus. The default is to detect any available driver type and use it. driver buffet, no cap πŸš—
  • -J β€” Use the specified LanPlus cipher suite (0 thru 17): 0=none/none/none, 1=sha1/none/none, 2=sha1/sha1/none, 3=sha1/sha1/cbc128, 4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40, 6=md5/none/none, ... 14=md5/md5/xrc4_40. Default is 3. cipher suite lineup, iconic πŸ”₯
  • -T β€” Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2, 2=MD5, 4=Straight Password, 5=OEM. auth type moment πŸ”‘
  • -V β€” Use a specified IPMI LAN privilege level. 1=Callback level, 2=User level, 3=Operator level, 4=Administrator level (default), 5=OEM level. choose your level bestie πŸ‘‘
  • -Y β€” Yes, do prompt the user for the IPMI LAN remote password. Alternatives for the password are -E or -P. yes bestie, actually ask πŸ™ˆ

πŸ‘‘ COMMANDS πŸ‘‘

intrusion

This command resets any chassis intrusion condition that may have occurred. reset the drama, periodt πŸšͺ✨

bmcstatus [enable|disable]

This command gets or sets the BMC service status. Alone, without arguments, it gets the BMC status as either enabled or disabled. With an argument of either enable or disable, it will also set the BMC status as specified. status check + status set, dual icon behavior πŸ’…

firmware

This command gets the extra firmware version information, if available. firmware lore drop if it exists 🧚

lanport [dedicated|lan1|failover]

This command gets or sets the IPMI LAN interface port. If set to dedicated, only the dedicated IPMI NIC can be configured for IPMI LAN. If set to lan1, only the first onboard NIC (LAN1) can be configured for IPMI LAN. If set to failover, both the dedicated and onboard LAN1 port would be configured for IPMI LAN, with the same IP address. lan port choices are giving main character energy 🌈

🌸 SEE ALSO 🌸

ipmiutil(8) ialarms(8) iconfig(8) icmd(8) idiscover(8) ievents(8) ifru(8) igetevent(8) ihealth(8) ilan(8) ireset(8) isel(8) isensor(8) iserial(8) isol(8)

⚠️ WARNINGS ⚠️

See http://ipmiutil.sourceforge.net/ for the latest version of ipmiutil and any bug fix list. read the site, bestie, it's important 🫢

Copyright (C) 2013 Andy Cress

See the file COPYING in the distribution for more details regarding redistribution.