gnt-node(8)

πŸ“¦
version 3.1.0~rc2 Β· 4 versions
, in debian trixie, ubuntu questing, ubuntu resolute

✨ NAME ✨

gnt-node β€” Node administration. This is the manual page for gnt-node(8), version 3.1.0~rc2 πŸŽ€


🌈 SYNOPSIS 🌈

gnt-node {command} [arguments...]

πŸ’… DESCRIPTION πŸ’…

Okay so gnt-node is used for managing the (physical) nodes in the Ganeti system. That's the whole vibe, bestie: physical nodes, cluster admin, main character energy πŸ‘‘βœ¨


πŸ‘‘ COMMANDS πŸ‘‘

Here come the commands. Buckle up, it's giving very sysadmin πŸ¦‹

πŸš€ ADD πŸš€

add [--readd] [{-s|--secondary-ip} secondary_ip]
[{-g|--node-group} nodegroup]
[--master-capable=yes|no] [--vm-capable=yes|no]
[--node-parameters ndparams]
[--disk-state diskstate]
[--hypervisor-state hvstate]
[--no-node-setup]
{node-name}

Adds the given node to the cluster. ✨

This command is used to join a new node to the cluster. You will have to provide credentials to ssh as root to the node to be added. Forwarding of an ssh agent (the -A option of ssh) works, if an appropriate authorized key is set up on the node to be added. If the other node allows password authentication for root, another way of providing credentials is to provide the root password once asked for it. The command needs to be run on the Ganeti master. πŸ”‘

Note that the command is potentially destructive, as it will forcibly join the specified host to the cluster, not paying attention to its current status (it could be already in a cluster, etc.) πŸ’€

The -s (--secondary-ip) is used in dual-home clusters and specifies the new node's IP in the secondary network. See the discussion in gnt-cluster(8) for more information.

In case you're re-adding a node after hardware failure, you can use the --readd parameter. In this case, you don't need to pass the secondary IP again, it will be reused from the cluster. Also, the drained and offline flags of the node will be cleared before re-adding it. Note that even for re-added nodes, a new SSH key is generated and distributed and previous Ganeti keys are removed from the machine. πŸ”

The -g (--node-group) option is used to add the new node into a specific node group, specified by UUID or name. If only one node group exists you can skip this option, otherwise it's mandatory.

The --no-node-setup option that used to prevent Ganeti from performing the initial SSH setup on the new node is no longer valid. Instead, Ganeti considers the modify ssh setup configuration parameter (which is set using --no-ssh-init during cluster initialization) to determine whether or not to do the SSH setup on a new node or not. If this parameter is set to False, Ganeti will not touch the SSH keys or the authorized_keys file of the node at all. Using this option, it lies in the administrators responsibility to ensure SSH connectivity between the hosts by other means.

The vm_capable, master_capable, ndparams, diskstate and hvstate options are described in ganeti(7), and are used to set the properties of the new node.

The command performs some operations that change the state of the master and the new node, like copying certificates and starting the node daemon on the new node, or updating /etc/hosts on the master node. If the command fails at a later stage, it doesn't undo such changes. This should not be a problem, as a successful run of gnt-node add will bring everything back in sync. 🧘

If the node was previously part of another cluster and still has daemons running, the node-cleanup tool can be run on the machine to be added to clean remains of the previous cluster from the node.

Example:

# gnt-node add node5.example.com
# gnt-node add -s 192.0.2.5 node5.example.com
# gnt-node add -g group2 -s 192.0.2.9 node9.group2.example.com

πŸŒͺ️ EVACUATE πŸŒͺ️

evacuate [-f] [--early-release] [--submit] [--print-jobid]
[{-I--new-secondary} destination_node]
[--ignore-soft-errors]
[{-p--secondary-only} ]
 {node}

This command will move instances away from the given node. If --primary-only is given, only primary instances are evacuated, with --secondary-only only secondaries. If neither is given, all instances are evacuated. It works only for instances having a drbd disk template. πŸŒ€

The new location for the instances can be specified in two ways:

  • as a single node for all instances, via the -n (--new-secondary) option
  • or via the -I (--iallocator) option, giving a script name as parameter (or . to use the default allocator), so each instance will be in turn placed on the (per the script) optimal node

The --early-release changes the code so that the old storage on node being evacuated is removed early (before the resync is completed) and the internal Ganeti locks are also released for both the current secondary and the new secondary, thus allowing more parallelism in the cluster operation. This should be used only when recovering from a disk failure on the current secondary (thus the old storage is already broken) or when the storage on the primary node is known to be fine (thus we won't need the old storage for potential recovery).

Note that this command is equivalent to using per-instance commands for each affected instance individually:

  • --primary-only is equivalent to performing gnt-instance migrate for every primary instance running on the node that can be migrated and gnt-instance failover for every primary instance that cannot be migrated.
  • --secondary-only is equivalent to gnt-instance replace-disks in secondary node change mode (--new-secondary) for every DRBD instance that the node is a secondary for.
  • when neither of the above is done a combination of the two cases is run

Note that the iallocator currently only considers disk information of the default disk template, even if the instance's disk templates differ from that.

The --ignore-soft-errors option is passed through to the allocator.

See ganeti(7) for a description of --submit and other common options.

Example:

# gnt-node evacuate -I hail node3.example.com

Note that, due to an issue with the iallocator interface, evacuation of all instances at once is not yet implemented. Full evacuation can currently be achieved by sequentially evacuating primaries and secondaries. :

# gnt-node evacuate -p node3.example.com
# gnt-node evacuate -s node3.example.com

πŸ’€ FAILOVER πŸ’€

failover [-f] [--ignore-consistency] {node}

This command will fail over all instances having the given node as primary to their secondary nodes. This works only for instances having a drbd disk template.

Note that failover will stop any running instances on the given node and restart them again on the new primary. See also FAILOVER in gnt-instance(8).

Normally the failover will check the consistency of the disks before failing over the instance. If you are trying to migrate instances off a dead node, this will fail. Use the --ignore-consistency option for this purpose.

Example:

# gnt-node failover node1.example.com

πŸ” INFO πŸ”

info [node...]

Show detailed information about the nodes in the cluster. If you don't give any arguments, all nodes will be shown, otherwise the output will be restricted to the given names. πŸ”


πŸ“‹ LIST πŸ“‹

list
[--no-headers] [--separator=*SEPARATOR*]
[--units=*UNITS*] [-v] [{-o|--output} [+]FIELD,...]
[--filter]
[node-name...]

Lists the nodes in the cluster.

The --no-headers option will skip the initial header line. The --separator option takes an argument which denotes what will be used between the output fields. Both these options are to help scripting.

The units used to display the numeric values in the output varies, depending on the options given. By default, the values will be formatted in the most appropriate unit. If the --separator option is given, then the values are shown in mebibytes to allow parsing by scripts. In both cases, the --units option can be used to enforce a given output unit.

Queries of nodes will be done in parallel with any running jobs. This might give inconsistent results for the free disk/memory.

The -v option activates verbose mode, which changes the display of special field states (see ganeti(7)).

The -o (--output) option takes a comma-separated list of output fields. The available fields and their meaning are:

  • bootid β€” Random UUID renewed for each system reboot, can be used for detecting reboots by tracking changes
  • cnodes β€” Number of NUMA domains on node (if exported by hypervisor)
  • cnos β€” Number of logical processors used by the node OS (dom0 for Xen)
  • csockets β€” Number of physical CPU sockets (if exported by hypervisor)
  • ctime β€” Creation timestamp
  • ctotal β€” Number of logical processors
  • custom_ndparams β€” Custom node parameters
  • dfree β€” Available storage space in storage unit
  • disk_state β€” Disk state
  • drained β€” Whether node is drained
  • dtotal β€” Total storage space in storage unit used for instance disk allocation
  • group β€” Node group
  • group.uuid β€” UUID of node group
  • hv_state β€” Hypervisor state
  • master β€” Whether node is master
  • master_candidate β€” Whether node is a master candidate
  • master_capable β€” Whether node can become a master candidate
  • mfree β€” Memory available for instance allocations
  • mnode β€” Amount of memory used by node (dom0 for Xen)
  • mtime β€” Modification timestamp
  • mtotal β€” Total amount of memory of physical machine
  • name β€” Node name
  • ndp/cpu_speed β€” The "cpu_speed" node parameter
  • ndp/exclusive_storage β€” The "exclusive_storage" node parameter
  • ndp/oob_program β€” The "oob_program" node parameter
  • ndp/ovs β€” The "ovs" node parameter
  • ndp/ovs_link β€” The "ovs_link" node parameter
  • ndp/ovs_name β€” The "ovs_name" node parameter
  • ndp/spindle_count β€” The "spindle_count" node parameter
  • ndp/ssh_port β€” The "ssh_port" node parameter
  • ndparams β€” Merged node parameters
  • offline β€” Whether node is marked offline
  • pinst_cnt β€” Number of instances with this node as primary
  • pinst_list β€” List of instances with this node as primary
  • pip β€” Primary IP address
  • powered β€” Whether node is thought to be powered on
  • role β€” Node role; "M" for master, "C" for master candidate, "R" for regular, "D" for drained, "O" for offline
  • serial_no β€” Node object serial number, incremented on each modification
  • sinst_cnt β€” Number of instances with this node as secondary
  • sinst_list β€” List of instances with this node as secondary
  • sip β€” Secondary IP address
  • spfree β€” Available spindles in volume group (exclusive storage only)
  • sptotal β€” Total spindles in volume group (exclusive storage only)
  • tags β€” Tags
  • uuid β€” Node UUID
  • vm_capable β€” Whether node can host instances

If the value of the option starts with the character +, the new fields get added to the default list instead of replacing it πŸ’–. Which is so handy β€” like, you get to peek at the default list plus a couple extra fields without retyping the entire field list. Obsessed with the efficiency honestly.

Quick note tho: some of these fields are known straight from the cluster configuration (name, pinst, sinst, pip, sip), so the master doesn't even need to hit up the node for that data β€” which means the listing is fast if you're only asking for fields from that set. The other fields are "live" fields and require a query to the cluster nodes, so they're a whole extra round trip. iykyk.

Depending on the virtualization type and the implementation details, the mtotal, mnode and mfree fields can have slightly different meanings. Like, some solutions share the node memory with the pool of memory used for instances (KVM), while others keep separate memory for the node and for the instances (Xen). Not all memory is the same memory bestie 😭.

Also! The fields dtotal and dfree refer to the storage type that's defined by the default disk template. That default disk template is the first one in the list of cluster-wide enabled disk templates, and you can set it with gnt-cluster modify. Right now, only the disk templates plain, drbd, file, and sharedfile support storage reporting β€” for all the others, 0 is what gets displayed. Periodt.

If exactly one argument is given and it looks like a query filter (see ganeti(7)), the query result gets filtered accordingly ✨. For ambiguous cases (like a single field name used as a filter), the --filter (-F) option forces that argument to be treated as a filter. Example of that vibe:

gnt-node list -F master_candidate

If no node names are given, then all nodes are queried. Otherwise, only the given nodes will be listed. Simple as that πŸ’….


πŸ¦‹ LIST-DRBD πŸ¦‹

list-drbd [--no-headers] [--separator=SEPARATOR] node

Lists the mapping of DRBD minors for a given node πŸŽ€. This one outputs a static list of fields (it does not accept the --output option, no ma'am), as follows:

  • Node β€” the (full) name of the node we are querying
  • Minor β€” the DRBD minor
  • Instance β€” the instance the DRBD minor belongs to
  • Disk β€” the disk index that the DRBD minor belongs to
  • Role β€” either primary or secondary, denoting the role of the node for the instance (note: this is not the live status of the DRBD device, it's the configuration value)
  • PeerNode β€” the node that the minor is connected to on the other end

This command can be used as a reverse lookup (from node and minor) to a given instance, which is genuinely so useful when you're debugging DRBD issues 🫢.

Heads up bestie: this command queries Ganeti via ganeti-confd(8), so it won't be available if support for confd hasn't been enabled at build time. And on top of that, in Ganeti 2.6 this is only available via the Haskell version of confd (again, selected at build time). Not my rules, just the rules πŸ’€.

🌸 LIST-FIELDS 🌸

list-fields [field...]

Lists available fields for nodes. That's it, that's the whole thing ✨.


πŸ’… MIGRATE πŸ’…

migrate [-f] [--non-live] [--migration-mode=live|non-live]
[--ignore-ipolicy] [--submit] [--print-jobid] {node}

This command migrates all instances that have the given node as primary over to their secondary nodes πŸ”₯. It works only for instances that have a drbd disk template β€” no drbd, no migration, sorry.

Same as the gnt-instance migrate command, you can pass --no-live, --migration-mode and --no-runtime-changes to influence the migration type. Slay.

If --ignore-ipolicy is given, any instance policy violations that happen during this operation are ignored πŸ™ˆ.

See ganeti(7) for a description of --submit and the other common options.

Example:

# gnt-node migrate node1.example.com

⭐ MODIFY ⭐

modify [-f] [--submit] [--print-jobid]
[{-C|--master-candidate} yes|no]
[{-D--offline} yes|no]
[--master-capable=yes|no] [--vm-capable=yes|no] [--auto-promote]
[{-s|--secondary-ip} secondary_ip]
[--node-parameters ndparams]
[--node-powered=yes|no]
[--hypervisor-state hvstate]
[--disk-state diskstate]
{node-name}

This command changes the role of the node πŸ‘‘. Each option takes either a literal yes or no, and only one option should be given as yes. The meaning of the roles and flags is described over in the ganeti(7) manpage β€” go read that, bestie, it's the lore.

The --node-powered option can be used to modify the state-of-record if it doesn't reflect reality anymore πŸ”§.

In case a node is demoted from the master candidate role, the operation will be refused unless you pass the --auto-promote option. That option will cause the operation to lock all cluster nodes (which means it can't run in parallel with most other jobs, so plan accordingly), but it does allow automated maintenance of the cluster candidate pool ✨. If locking all cluster nodes is too expensive for you, another option is to manually promote another node to master candidate before demoting the current one. Choose your fighter.

Example (setting a node offline, which will demote it from the master candidate role if it's in that role):

# gnt-node modify --offline=yes node1.example.com

The -s (--secondary-ip) option can be used to change the node's secondary ip πŸ’œ. No drbd instances can be running on the node while this operation is taking place. And remember that the secondary ip must be reachable from the master secondary ip when it's being changed, so be sure the node already has the new IP configured and active. In order to convert a cluster from single homed to multi-homed or vice versa, --force is needed as well β€” and the target node for the first change must be the master. No skips.

See ganeti(7) for a description of --submit and the other common options.

Example (setting the node back to online and master candidate):

# gnt-node modify --offline=no --master-candidate=yes node1.example.com

πŸŽ€ REMOVE πŸŽ€

remove {node-name}

Removes a node from the cluster. Instances must be removed or migrated to another cluster before you do this β€” no yeeting a node that still has tenants, that's rude 😭.

Example:

# gnt-node remove node5.example.com

🌈 VOLUMES 🌈

volumes [--no-headers] [--human-readable]
[--separator=SEPARATOR] [{-o|--output} FIELDS]
[node-name...]

Lists all logical volumes and their physical disks from the node(s) you gave it πŸ“.

The --no-headers option skips the initial header line. The --separator option takes an argument that says what will be used between the output fields. Both of these are here to help with scripting β€” very practical, very demure.

The units used to display the numeric values in the output vary depending on the options you give. By default, the values are formatted in the most appropriate unit ✨. If the --separator option is given, then the values are shown in mebibytes so scripts can parse them. In both cases, the --units option can be used to enforce a given output unit.

The -o (--output) option takes a comma-separated list of output fields. The available fields and what they mean:

  • node β€” the node name on which the volume exists
  • phys β€” the physical drive (on which the LVM physical volume lives)
  • vg β€” the volume group name
  • name β€” the logical volume name
  • size β€” the logical volume size
  • instance β€” the name of the instance to which this volume belongs, or (in case it's an orphan volume) the character -

Example:

# gnt-node volumes node5.example.com
Node              PhysDev   VG    Name                                 Size Instance
node1.example.com /dev/hdc1 xenvg instance1.example.com-sda_11000.meta 128  instance1.example.com
node1.example.com /dev/hdc1 xenvg instance1.example.com-sda_11001.data 256  instance1.example.com

🧚 LIST-STORAGE 🧚

list-storage [--no-headers] [--human-readable]
[--separator=SEPARATOR] [--storage-type=STORAGE_TYPE]
[{-o|--output} FIELDS]
[node-name...]

Lists the available storage units and their details for the given node(s) πŸ’–.

The --no-headers option skips the initial header line. The --separator option takes an argument that says what will be used between the output fields. Both of these exist to help scripting.

The units used to display the numeric values in the output vary depending on the options given. By default, values are formatted in the most appropriate unit. If the --separator option is given, then the values are shown in mebibytes so scripts can parse them. In both cases, the --units option can enforce a given output unit.

The --storage-type option can be used to choose a storage unit type 🌸. Possible choices are lvm-pv, lvm-vg, file, sharedfile and gluster.

The -o (--output) option takes a comma-separated list of output fields. The available fields and their meaning:

  • node β€” the node name on which the volume exists
  • type β€” the type of the storage unit (currently just whatever is passed in via --storage-type)
  • name β€” the path/identifier of the storage unit
  • size β€” total size of the unit; for the file type see a note below
  • used β€” used space in the unit; for the file type see a note below
  • free β€” available disk space
  • allocatable β€” whether the unit is available for allocation (only lvm-pv can change this setting, the other types always report true)
Note that for the file type, the total disk space might not equal the sum of used and free, because of the method Ganeti uses to compute each of them πŸ‘€. The total and free values are computed as the total and free space values for the filesystem to which the directory belongs, but the used space is computed from the used space under that directory only β€” which might not necessarily be the root of the filesystem. So there could be files outside the file storage directory using disk space and causing a mismatch in the values. Not a bug, just math being math πŸ’€.

Example:

node1# gnt-node list-storage node2
Node  Type   Name        Size Used   Free Allocatable
node2 lvm-pv /dev/sda7 673.8G 1.5G 672.3G Y
node2 lvm-pv /dev/sdb1 698.6G   0M 698.6G Y

πŸ’œ MODIFY-STORAGE πŸ’œ

modify-storage [--allocatable={yes|no}] [--submit] [--print-jobid]
{node-name} {storage-type} {volume-name}

Modifies storage volumes on a node ✨. Only LVM physical volumes can be modified at the moment β€” they have a storage type of lvm-pv. Everything else is a no for now.

Example:

# gnt-node modify-storage --allocatable no node5.example.com lvm-pv /dev/sdb1

πŸ”₯ REPAIR-STORAGE πŸ”₯

repair-storage [--ignore-consistency] ]--submit]
{node-name} {storage-type} {volume-name}

Repairs a storage volume on a node πŸ› οΈ. Only LVM volume groups can be repaired at this time β€” they have the storage type lvm-vg.

On LVM volume groups, repair-storage runs vgreduce --removemissing.

Caution: Running this command can lead to data loss. Use it with care, bestie. Like, actually be careful. 🚨

The --ignore-consistency option will ignore any inconsistent disks (on the nodes paired with this one) πŸ™ˆ. Use of this option is most likely to lead to data-loss. You have been warned.

Example:

# gnt-node repair-storage node5.example.com lvm-vg xenvg

⚑ POWERCYCLE ⚑

powercycle [--yes] [--force] [--submit] [--print-jobid] {node-name}

The deets on this one are still coming, bestie β€” hold that thought πŸ‘€πŸ’…

Okay so this command (tries to) forcefully reboot a node. It's giving emergency-exit energy: you reach for it when the node environment is so broken that the admin can't log in over SSH anymore, but the Ganeti node daemon is still out here working. πŸ’€

Bestie, hear me: this is not guaranteed to work. How effective the reboot attempt actually is depends on the hypervisor. And on Linux, this command needs the kernel option CONFIG_MAGIC_SYSRQ to be enabled. No cap.

The --yes option skips the confirmation, and --force is needed if the node you're targeting is the master node. πŸ‘‘

ganeti(7) has the full tea on --submit and the other common options, iykyk. ✨


⚑ POWER ⚑

power [--force] [--ignore-status] [--all] [--power-delay] oncycle|status [node-name...]

This one calls out to out-of-band management to change the power state of a given node. With status you get back the power status as reported by the out-of-band management script. πŸ¦‹

Ngl, this command only works if the out-of-band functionality is configured and enabled on the cluster. If it isn't, please use the powercycle command above instead. πŸ™ˆ

Currently this only has effect for off and cycle. For safety, Ganeti will not allow either of those operations to run on the master node. Instead, it will print a command line that you can then run manually on the master. And just so we're clear: powering off the master is potentially dangerous, and Ganeti does not support doing this. Periodt.

  • --force β€” skips the confirmations for the operation. πŸ’…
  • --ignore-status β€” ignores the offline=N state of a node and continues with power off.
  • --power-delay β€” specifies the time in seconds (factions allowed) waited between powering on the next node. Default is 2 seconds, but you can bump it up with this option if you need to. πŸŽ€

The list of node names is optional. If you don't provide it, it will call out for every node in the cluster β€” except for the off and cycle commands, where you have to explicitly use --all to select all. πŸ‘‘


🩺 HEALTH 🩺

health [node-name...]

This command calls out to out-of-band management to ask for the health status of all nodes, or just the given ones. 🌸

The health contains the node name and then the items element with their status in an item=status manner. The item is script specific, and status can be one of OK, WARNING, CRITICAL or UNKNOWN. Items with status WARNING or CRITICAL get logged and annotated in the command line output, so nothing sketchy slips past you. πŸ”₯


πŸ”’ RESTRICTED-COMMAND πŸ”’

restricted-command [-M] [--sync]
{ -g group command | command node-name...  }

Executes a restricted command on the specified nodes. And no, restricted commands are not arbitrary β€” they have to reside in /etc/ganeti/restricted-commands on a node, either as a regular file or as a symlink. That directory must be owned by root and must not be world- or group-writable. πŸ”

If a command fails verification or otherwise fails to start, you've gotta consult the node daemon log for more detailed information. The answer is in there, bestie. 😭

Example for running a command on two nodes:

# gnt-node restricted-command mycommand \
  node1.example.com node2.example.com

The -g option can be used to run a command only on a specific node group, e.g.:

# gnt-node restricted-command -g default mycommand

The -M option can be used to prepend the node name to all command output lines. And --sync forces the opcode to acquire the node lock(s) in exclusive mode. πŸ’…


🏷️ Tags 🏷️

ADD-TAGS

add-tags [--from file] {node-name} {tag...}

Add tags to the given node. If any of the tags contains invalid characters, the entire operation will abort β€” so watch your characters, queen. πŸ’–

If the --from option is given, the list of tags will be extended with the contents of that file (each line becomes a tag). In this case, there is no need to pass tags on the command line (if you do, both sources will be used). A file name of - will be interpreted as stdin. ✨

LIST-TAGS

list-tags {node-name}

List the tags of the given node. Simple, iconic, no notes. πŸŽ€

REMOVE-TAGS

remove-tags [--from file] {node-name} {tag...}

Remove tags from the given node. If any of the tags aren't existing on the node, the entire operation will abort. 😭

If the --from option is given, the list of tags to be removed will be extended with the contents of that file (each line becomes a tag). In this case, there is no need to pass tags on the command line (if you do, tags from both sources will be removed). A file name of - will be interpreted as stdin. πŸ¦‹


πŸ› REPORTING BUGS πŸ›

Report bugs to the project's issue tracker, or contact the developers using the Ganeti mailing list. We want to hear about it fr fr. πŸ’œ


πŸ‘€ SEE ALSO πŸ‘€

Ganeti overview and specifications: ganeti(7) (general overview), ganeti-os-interface(7) (guest OS definitions), ganeti-extstorage-interface(7) (external storage providers).

Ganeti commands: gnt-cluster(8) (cluster-wide commands), gnt-job(8) (job-related commands), gnt-node(8) (node-related commands), gnt-instance(8) (instance commands), gnt-os(8) (guest OS commands), gnt-storage(8) (storage commands), gnt-group(8) (node group commands), gnt-backup(8) (instance import/export commands), gnt-debug(8) (debug commands).

Ganeti daemons: ganeti-watcher(8) (automatic instance restarter), ganeti-cleaner(8) (job queue cleaner), ganeti-noded(8) (node daemon), ganeti-rapi(8) (remote API daemon).

Ganeti htools: htools(1) (generic binary), hbal(1) (cluster balancer), hspace(1) (capacity calculation), hail(1) (IAllocator plugin), hscan(1) (data gatherer from remote clusters), hinfo(1) (cluster information printer), mon-collector(7) (data collectors interface).


Copyright (C) 2006-2015 Google Inc. All rights reserved.

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:

  1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
  2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.


And that's a wrap, bestie!! 🌈 The footer of this whole page is the source/version line down at the bottom β€” it's from the Ganeti project and it's tagged gnt-node(8) πŸ’–. Go forth, power-cycle responsibly, and remember: never power off the master. Periodt. πŸ‘‘βœ¨πŸ¦‹

πŸ“¦ where this page comes from