snmpd.examples β example configuration for the Net-SNMP agent
πΈ DESCRIPTION πΈ
okay so the snmpd.conf(5) man page is the one that defines the syntax and behaviour of all the various configuration directives you can use to control the operation of the Net-SNMP agent, plus the management information it provides. slay.
This companion man page is literally here to illustrate those directives, showing you some practical examples of how they might be used. think of it as the group chat where the config actually gets styled. π
π AGENT BEHAVIOUR π
π§ Listening addresses
The default agent behaviour β hitting the standard SNMP UDP port on all interfaces β is equivalent to the directive:
agentaddress udp:161
or simply:
agentaddress 161
The agent can be configured to only accept requests sent to the local loopback interface (again listening on the SNMP UDP port), using:
agentaddress localhost:161 # (udp implicit)
or:
agentaddress 127.0.0.1 # (udp and standard port implicit)
It can be configured to accept both UDP and TCP requests (over both IPv4 and IPv6), using:
agentaddress udp:161,tcp:161,udp6:161,tcp6:161
Other combinations are also valid. no cap, the address list is giving customizable main character energy. β¨
π‘οΈ Run-time privileges
The agent can be configured to relinquish any privileged access once it has opened the initial listening ports. Given a suitable "snmp" group (defined in /etc/group), this could be done using the directives:
agentuser nobody
agentgroup snmp
A similar effect could be achieved using numeric UID and/or GID values:
agentuser #10
agentgroup #10
π SNMPv3 Configuration
Rather than being generated pseudo-randomly, the engine ID for the agent could be calculated based on the MAC address of the second network interface (eth1), using the directives:
engineIDType 3 engineIDNic eth1
or it could be calculated from the (first) IP address, using:
engineIDType 1
or it could be specified explicitly, using:
engineID "XXX - WHAT FORMAT"
π ACCESS CONTROL π
π«Ά SNMPv3 Users
The following directives will create three users, all using exactly the same authentication and encryption settings:
createUser me MD5 "single pass phrase"
createUser myself MD5 "single pass phrase" DES
createUser andI MD5 "single pass phrase" DES "single pass phrase"
Note that this defines three distinct users, who could be granted different levels of access. Changing the passphrase for any one of these would not affect the other two. lowkey important.
Separate pass phrases can be specified for authentication and encryption:
createUser onering SHA "to rule them all" AES "to bind them"
Remember that these createUser directives should be defined in the /var/lib/net-snmp/snmpd.conf file, rather than the usual location. yes bestie, the special file. π
ποΈ Traditional Access Control
The SNMPv3 users defined above can be granted access to the full MIB tree using the directives:
rouser me
rwuser onering
Or selective access to individual subtrees using:
rouser myself .1.3.6.1.2
rwuser andI system
Note that a combination repeating the same user, such as:
rouser onering
rwuser onering
should not be used. This would configure the user onering with read-only access (and ignore the rwuser entry altogether). The same holds for the community-based directives. periodt.
The directives:
rocommunity public
rwcommunity private
would define the commonly-expected read and write community strings for SNMPv1 and SNMPv2c requests. This behaviour is not configured by default, and would need to be set up explicitly.
Note: It would also be a very good idea to change private to something a little less predictable! π«£
A slightly less vulnerable configuration might restrict what information could be retrieved:
rocommunity public default system
or the management systems that settings could be manipulated from:
rwcommunity private 10.10.10.0/24
or a combination of the two.
π§ VACM Configuration
This last pair of settings are equivalent to the full VACM definitions:
# sec.name source community
com2sec public default public
com2sec mynet 10.10.10.0/24 private
com2sec6 mynet fec0::/64 private
# sec.model sec.name
group worldGroup v1 public
group worldGroup v2c public
group myGroup v1 mynet
group myGroup v2c mynet
# incl/excl subtree [mask]
view all included .1
view sysView included system
# context model level prefix read write notify (unused)
access worldGroup "" any noauth exact system none none
access myGroup "" any noauth exact all all none
There are several points to note in this example:
- The
groupdirectives must be repeated for both SNMPv1 and SNMPv2c requests. - The
com2secsecurity name is distinct from the community string that is mapped to it. They can be the same ("public") or different ("mynet"/"private") β but what appears in thegroupdirective is the security name, regardless of the original community string. - Both of the
viewdirectives are defining simple OID subtrees, so neither of these require an explicit mask. The same holds for the "combined subtree2 view defined below. In fact, a mask field is only needed when defining row slices across a table (or similar views), and can almost always be omitted. - In general, it is advisable not to mix traditional and VACM-based access configuration settings, as these can sometimes interfere with each other in unexpected ways. Choose a particular style of access configuration, and stick to it.
π¦ Typed-View Configuration
A similar configuration could also be configured as follows:
view sys2View included system
view sys2View included .1.3.6.1.2.1.25.1
authcommunity read public default -v sys2View
authcommunity read,write private 10.10.10.0/8
This mechanism allows multi-subtree (or other non-simple) views to be used with the one-line rocommunity style of configuration.
It would also support configuring "write-only" access, should this be required. iykyk. π
β SYSTEM INFORMATION β
π System Group
The full contents of the 'system' group (with the exception of sysUpTime) can be explicitly configured using:
# Override 'uname -a' and hardcoded system OID - inherently read-only values
sysDescr Universal Turing Machine mk I
sysObjectID .1.3.6.1.4.1.8072.3.2.1066
# Override default values from 'configure' - makes these objects read-only
sysContact Alan.Turing@pre-cs.man.ac.uk
sysName tortoise.turing.com
sysLocation An idea in the mind of AT
# Standard end-host behaviour
sysServices 72
π§΅ Host Resources Group
The list of devices probed for potential inclusion in the hrDiskStorageTable (and hrDeviceTable) can be amended using any of the following directives:
ignoredisk /dev/rdsk/c0t2d0
which prevents the device /dev/rdsk/c0t2d0 from being scanned,
ignoredisk /dev/rdsk/c0t[!6]d0
ignoredisk /dev/rdsk/c0t[0-57-9a-f]d0
either of which prevents all devices /dev/rdsk/c0tXd0 (except .../c0t6d0) from being scanned,
ignoredisk /dev/rdsk/c1*
which prevents all devices whose device names start with /dev/rdsk/c1 from being scanned, or
ignoredisk /dev/rdsk/c?t0d0
which prevents all devices /dev/rdsk/cXt0d0 (where 'X' is any single character) from being scanned.
πΈ Process Monitoring
The list of services running on a system can be monitored (and provision made for correcting any problems), using:
# At least one web server process must be running at all times
proc httpd
procfix httpd /etc/rc.d/init.d/httpd restart
# There should never be more than 10 mail processes running
# (more implies a probable mail storm, so shut down the mail system)
proc sendmail 10
procfix sendmail /etc/rc.d/init.d/sendmail stop
# There should be a single network management agent running
# ("There can be only one")
proc snmpd 1 1
Also see the "DisMan Event MIB" section later on.
πΎ Disk Usage Monitoring
The state of disk storage can be monitored using:
includeAllDisks 10%
disk /var 20%
disk /usr 3%
# Keep 100 MB free for crash dumps
disk /mnt/crash 100000
π₯ System Load Monitoring
A simple check for an overloaded system might be:
load 10
A more refined check (to allow brief periods of heavy use, but recognise sustained medium-heavy load) might be:
load 30 10 5
π Log File Monitoring
TODO
file FILE [MAXSIZE]
logmatch NAME PATH CYCLETIME REGEX
β¨ ACTIVE MONITORING β¨
π Notification Handling
So if you want the agent to report invalid access attempts, you'd lowkey do this:
authtrapenable 1
trapcommunity public
trap2sink localhost
Or, bestie, you can smoosh the second and third directives together (and ask for an acknowledgment while you're at it) like this:
informsink localhost public
But hear me out β a config with repeated sink destinations, like:
trapsink localhost
trap2sink localhost
informsink localhost
should NOT be used, fr fr. That'll send multiple copies of every single trap to the same receiver, and that's giving messy. π
TODO β discuss SNMPv3 traps trapsess snmpv3 options localhost:162
TODO β mention trapd access configuration
π§ DisMan Event MIB
The simplest possible setup for the agent to actively self-monitor (by the agent, for the agent, iconic behavior honestly) is probably this:
# Set up the credentials to retrieve monitored values
createUser _internal MD5 "the first sign of madness"
iquerySecName _internal
rouser _internal
# Active the standard monitoring entries
defaultMonitors yes
linkUpDownNotifications yes
# If there's a problem, then tell someone!
trap2sink localhost
The first block sets up a user that's suitable for retrieving the info that's gonna get monitored, and then that next little pair of directives activates a bunch of built-in monitoring entries. π
Heads up though: the DisMan directives on their own are not enough to actively report problems β you also need a suitable destination configured so the notifications actually have somewhere to go. No destination, no drama delivered.
A more detailed monitor example looks like this:
monitor -u me -o hrSWRunName "high process memory" hrSWRunPerfMem > 10000
This defines an explicit boolean monitor entry, on the hunt for any process using more than 10MB of active memory. Those processes get reported using the (standard) DisMan trap mteTriggerFired, plus an extra (wildcarded) varbind hrSWRunName. π
This entry also specifies an explicit user (me, as defined earlier) for retrieving the monitored values and building the trap.
Now, objects that could potentially fluctuate around the level you set are better monitored with a threshold monitor entry:
monitor -D -r 10 "network traffic" ifInOctets 1000000 5000000
This sends a mteTriggerRising trap whenever incoming traffic rises above (roughly) 500 kB/s on any network interface, and a corresponding mteTriggerFalling trap when it drops below 100 kB/s again. Slay. ππ
Note that this monitors the deltas between successive samples (-D) rather than the actual sample values themselves. The same effect could be obtained using:monitor -r 10 "network traffic" ifInOctets - - 1000000 5000000
The linkUpDownNotifications directive above is broadly equivalent to:
notificationEvent linkUpTrap linkUp ifIndex ifAdminStatus ifOperStatus
notificationEvent linkDownTrap linkDown ifIndex ifAdminStatus ifOperStatus
monitor -r 60 -e linkUpTrap "Generate linkUp" ifOperStatus != 2
monitor -r 60 -e linkDownTrap "Generate linkDown" ifOperStatus == 2
This defines the traps to send (using notificationEvent) and explicitly references the relevant notification in the corresponding monitor entry (instead of using the default DisMan traps).
And the defaultMonitors directive from up there is equivalent to a whole series of (boolean) monitor entries:
monitor -o prNames -o prErrMessage "procTable" prErrorFlag != 0
monitor -o memErrorName -o memSwapErrorMsg "memory" memSwapError != 0
monitor -o extNames -o extOutput "extTable" extResult != 0
monitor -o dskPath -o dskErrorMsg "dskTable" dskErrorFlag != 0
monitor -o laNames -o laErrMessage "laTable" laErrorFlag != 0
monitor -o fileName -o fileErrorMsg "fileTable" fileErrorFlag != 0
β¦and it'll send a trap whenever any of those entries indicate a problem. π
An alternative vibe would be to automatically invoke the corresponding "fix" action:
setEvent prFixIt prErrFix = 1
monitor -e prFixIt "procTable" prErrorFlag != 0
(and similarly for any of the other defaultMonitor entries).
β° DisMan Schedule MIB
The agent could be configured to reload its configuration once an hour, like:
repeat 3600 versionUpdateConfig.0 = 1
Or alternatively, it could be set up to run at specific times of day (maybe following rotation of the logs):
cron 10 0 * * * versionUpdateConfig.0 = 1
The one-shot style of scheduling is rather less common, but the secret SNMP virus could be activated on the next occurrence of Friday 13th using:
at 13 13 13 * 5 snmpVirus.0 = 1
Spooky. π
π¦ EXTENDING AGENT FUNCTIONALITY π¦
π οΈ Arbitrary Extension Commands
Old Style
exec [MIBOID] NAME PROG ARGS"
sh [MIBOID] NAME PROG ARGS"
execfix NAME PROG ARGS"
New Style
extend [MIBOID] NAME PROG ARGS"
extendfix [MIBOID] NAME PROG ARGS"
π― MIB-Specific Extension Commands
One-Shot
"pass [-p priority] MIBOID PROG"
Persistent
"pass_persist [-p priority] MIBOID PROG"
πͺ Embedded Perl Support
If embedded perl support is enabled in the agent, the default initialisation is equivalent to these directives:
disablePerl false
perlInitFile /usr/share/snmp/snmp_perl.pl
The main mechanism for defining embedded perl scripts is the perl directive. A very simple (if somewhat pointless) MIB handler could be registered using:
perl use Data::Dumper;
perl sub myroutine { print "got called: ",Dumper(@_),"\n"; }
perl $agent->register('mylink', '.1.3.6.1.8765', \&myroutine);
This relies on the $agent object, defined in the example snmp_perl.pl file. π«Ά
A more realistic MIB handler might be:
XXX - WHAT ???
Alternatively, this code could be stored in an external file and loaded using:
perl 'do /usr/share/snmp/perl_example.pl';
π¦ Dynamically Loadable Modules
TODO dlmod NAME PATH"
π Proxy Support
A configuration for acting as a simple proxy for two other SNMP agents (running on remote systems) might look like:
com2sec -Cn rem1context rem1user default remotehost1
com2sec -Cn rem2context rem2user default remotehost2
proxy -Cn rem1context -v 1 -c public remotehost1 .1.3
proxy -Cn rem2context -v 1 -c public remotehost2 .1.3
(plus suitable access control entries, obviously).
The same proxy directives would also work with (incoming) SNMPv3 requests, which can specify a context directly. It'd probably be more sensible to use contexts of remotehost1 and remotehost2 β the names above were chosen to show how these directives work together. β¨
Note that the administrative settings for the proxied request are specified explicitly, and they're independent of the settings from the incoming request.
Another use for the proxy directive is to pass part of the OID tree to another agent (either on a remote host, or listening on a different port on the same system) while handling the rest internally:
proxy -v 1 -c public localhost:6161 .1.3.6.1.4.1.99
This mechanism can be used to link together two separate SNMP agents. π
A less usual approach is to map one subtree into a different area of the overall MIB tree (either locally or on a remote system):
# uses SNMPv3 to access the MIB tree .1.3.6.1.2.1.1 on 'remotehost'
# and maps this to the local tree .1.3.6.1.3.10
proxy -v 3 -l noAuthNoPriv -u user remotehost .1.3.6.1.3.10 .1.3.6.1.2.1.1
π± SMUX Sub-Agents
smuxsocket 127.0.0.1
smuxpeer .1.3.6.1.2.1.14 ospf_pass
π AgentX Sub-Agents
The Net-SNMP agent could be configured to operate as an AgentX master agent (listening on a non-standard named socket, and running with the access privileges defined earlier), using:
master agentx
agentXSocket /tmp/agentx/master
agentXPerms 0660 0550 nobody snmp
A sub-agent wishing to connect to this master agent would need the same agentXSocket directive, or the equivalent code:
netsnmp_ds_set_string(NETSNMP_DS_APPLICATION_ID, NETSNMP_DS_AGENT_X_SOCKET,
"/tmp/agentx/master");
A loopback networked AgentX configuration could be set up using:
agentXSocket tcp:localhost:705
agentXTimeout 5
agentXRetries 2
β¦on the master side, and:
agentXSocket tcp:localhost:705
agentXTimeout 10
agentXRetries 1
agentXPingInterval 600
β¦on the client. π
Note that the timeout and retry settings can be asymmetric for the two directions, and the sub-agent can poll the master agent at regular intervals (600s = every 10 minutes) to make sure the connection is still working.
π OTHER CONFIGURATION
override sysDescr.0 octet_str "my own sysDescr"
injectHandler stash_cache NAME table_iterator
π FILES
/etc/snmp/snmpd.conf
π SEE ALSO
snmpconf(1), snmpd.conf(5), snmp.conf(5), snmp_config(5), snmpd(8), EXAMPLE.conf, netsnmp_config_api(3).
okay that's the whole page bestie, go forth and configure π