okay bestie, welcome to Smokeping_probes_EchoPingPlugin(3) β the manual page for Smokeping::probes::EchoPingPlugin, which is literally the basis for using echoping(1) plugins as probes for SmokePing. π
π¦ OVERVIEW π¦
So what does it do? It measures roundtrip times for SmokePing with an echoping(1) plugin. The plugins currently shipped with echoping are implemented as separate probes based on this class, but the class can also be used directly. No cap. β¨
β¨ SYNOPSIS β¨
okay, here's the setup vibe β copy it exactly, bestie:
*** Probes ***
+EchoPingPlugin
binary = /usr/bin/echoping
forks = 5
offset = 50%
step = 300
# The following variables can be overridden in each target section
/^influx_.+/ = influx_location = In the basement
extraopts = -some-letter-the-author-did-not-think-of
ipversion = 4
pings = 5
plugin = random # mandatory
pluginargs = -p plugin_specific_arg
priority = 6
timeout = 1
tos = 0xa0
waittime = 1
# [...]
*** Targets ***
probe = EchoPingPlugin # if this should be the default probe
# [...]
+ mytarget
# probe = EchoPingPlugin # if the default probe is something else
host = my.host
/^influx_.+/ = influx_location = In the basement
extraopts = -some-letter-the-author-did-not-think-of
ipversion = 4
pings = 5
plugin = random # mandatory
pluginargs = -p plugin_specific_arg
priority = 6
timeout = 1
tos = 0xa0
waittime = 1
π VARIABLES π
okay, here's the whole variable menu β no skipping, fr fr. π
π§ Supported probe-specific variables
binaryβ The location of yourechopingbinary.- Default value:
/usr/bin/echoping
- Default value:
forksβ Run this many concurrent processes at maximum.- Example value:
5 - Default value:
5
- Example value:
offsetβ If you run many probes concurrently you may want to prevent them from hitting your network all at the same time. Using the probe-specificoffsetparameter you can change the point in time when each probe will be run.offsetis specified in % of total interval, or alternatively as'random', and the offset from the'General'section is used if nothing is specified here. Note that this does NOT influence the rrds itself, it is just a matter of when data acquisition is initiated. (This variable is only applicable if the variable'concurrentprobes'is set in the'General'section.)- Example value:
50%
- Example value:
stepβ Duration of the base interval that this probe should use, if different from the one specified in the'Database'section. Note that the step in the RRD files is fixed when they are originally generated, and if you change thestepparameter afterwards, you'll have to delete the old RRD files or somehow convert them. (This variable is only applicable if the variable'concurrentprobes'is set in the'General'section.)- Example value:
300
- Example value:
π― Supported target-specific variables
/^influx_.+/β This is a tag that will be sent toinfluxdband has no impact on the probe measurement. The tag name will be sent without the"influx_"prefix, which will be replaced with"tag_"instead. Tags can be used for filtering.- Example value:
influx_location = In the basement
- Example value:
extraoptsβ Any extra options specified here will be passed unmodified toechoping(1).- Example value:
-some-letter-the-author-did-not-think-of
- Example value:
ipversionβ The IP protocol used. Possible values are"4"and"6". Passed toechoping(1)as the"-4"or"-6"options.- Example value:
4
- Example value:
pingsβ How many pings should be sent to each target, if different from the global value specified in the Database section. Note that the number of pings in the RRD files is fixed when they are originally generated, and if you change this parameter afterwards, you'll have to delete the old RRD files or somehow convert them.- Example value:
5
- Example value:
pluginβ Theechopingplugin that will be used. Seeechoping(1)for details. This can either be the name of the plugin or a full path to the plugin shared object.- Example value:
random - This setting is mandatory. π
- Example value:
pluginargsβ Any extra arguments needed by theechopingplugin specified with thepluginnamevariable. These are generally provided by the subclass probe.- Example value:
-p plugin_specific_arg
- Example value:
priorityβ The"-p"echoping(1)option.- Example value:
6
- Example value:
timeoutβ The"-t"echoping(1)option.- Example value:
1 - Default value:
5
- Example value:
tosβ The"-P"echoping(1)option.- Example value:
0xa0
- Example value:
waittimeβ The"-w"echoping(1)option.- Example value:
1
- Example value:
π AUTHORS π
Niko Tyni <ntyni@iki.fi> π
π«Ά NOTES π«Ά
β οΈ heads up, bestie: Thefill,sizeandudpEchoPing variables are not valid by default forEchoPingPlugin-derived probes.
Plugins are available starting with echoping version 6. π§
π SEE ALSO π
go read these next, iykyk:
Smokeping::probes::EchoPingSmokeping::probes::EchoPingLDAPSmokeping::probes::EchoPingDNSSmokeping::probes::EchoPingWhois