okay so this is the manual page for ipmitool(1) β ipmitool β the utility for controlling IPMI-enabled devices. bestie, it's a long one, so buckle up, hydrate, and let's go π
πΈ SYNOPSIS πΈ
ipmitool [ <options> ] <command> [ <sub-commands and sub-options> ]
<options> := [ <general-options> | <conditional-opts> ]
Any recognized option is accepted. Conditional options may be ignored or
it's usage postponed until shell or exec processes relevant command.
<general-options> := [ -h | -V | -v | -I <interface> | -H <address> |
-d <N> | -p <port> | -c | -U <username> |
-L <privlvl> | -l <lun> | -m <local_address> |
-N <sec> | -R <count> | <password-option> |
<oem-option> | <bridge-options> ]
<conditional-opts> := [ <lan-options> | <lanplus-options> |
<command-options> ]
Bridging:
<bridge-options> := -t <target_address> [ -b <channel> |
[ -T <address> | -B <channel> ] ]
Options used with -I lan:
<lan-options> := [ -A <authtype> ]
Options used with -I lanplus:
<lanplus-options> := [ -C <ciphersuite> | <key-option> ]
Option groups setting same value:
<key-option> := [ -k <key> | -K | -y <hex_key> | -Y ]
<password-option> := [ -f <password_file> | -a | -P <password> | -E ]
<oem-option> := [ -o <oemtype> | -g | -s ]
Options used with specific command <command-options>:
<options-sdr> := [ -S <sdr_cache_file> ]
<options-sel> := [ -O <sel_oem> ]
<options-sol> := [ -e <sol_escape_char> ]
so basically: <options> is either some general ones or some conditional ones, and any recognized option gets accepted β the conditional ones might just get ignored, or their usage gets postponed until a shell or exec process hits the relevant command. iykyk π«Ά
π¦ DESCRIPTION π¦
This program lets you manage Intelligent Platform Management Interface (IPMI) functions β either of the local system, via a kernel device driver, or of a remote system, using IPMI v1.5 and IPMI v2.0. And what does "manage" mean here? Obsessed you asked: printing FRU information, LAN configuration, sensor readings, and remote chassis power control. the range, honestly π
IPMI management of a local system interface requires a compatible IPMI kernel driver to be installed and configured. On Linux this driver is called OpenIPMI and it is included in standard distributions. On Solaris this driver is called BMC and it is included in Solaris 10. Management of a remote station requires the IPMI-over-LAN interface to be enabled and configured. Depending on the particular requirements of each system it may be possible to enable the LAN interface using ipmitool over the system interface. no cap, that's the whole vibe β¨
π OPTIONS π
-aβ Prompt for the remote server password. cute, interactive, it'll ask.-A <authtype>β Specify an authentication type to use during IPMIv1.5lansession activation. Supported types areNONE,PASSWORD,MD2,MD5, orOEM.-b <channel>β Set destination channel for bridged request.-B <channel>β Set transit channel for bridged request (dual bridge).-b <channel>β Set destination channel for bridged request. (yes it's in here twice, the page really do be like that π)-B <channel>β Set transit channel for bridged request. (dual bridge)-cβ Present output in CSV (comma separated variable) format. This is not available with all commands.-C <ciphersuite>β The remote server authentication, integrity, and encryption algorithms to use for IPMIv2.0lanplusconnections. See table 22-20 in the IPMI v2.0 specification. The default is17, which specifies RAKP-HMAC-SHA256 authentication, HMAC-SHA256-128 integrity, and AES-CBC-128 encryption algorithms.
NOTE: Inipmitool1.8.18 and earlier the default was3, which was insecure and was not supported by some more recent BMC implementations. so if you're on an old one, that's why, and also, respectfully, upgrade π
-d Nβ Use device number N to specify the/dev/ipmiN(or/dev/ipmi/Nor/dev/ipmidev/N) device to use for in-band BMC communication. Used to target a specific BMC on a multi-node, multi-BMC system through the ipmi device driver interface. Default is0.-e <sol_escape_char>β Use supplied character for SOL session escape character. The default is to use~but this can conflict withsshsessions. (the classic ~ jumpscare π)-Eβ The remote server password is specified by the environment variableIPMI_PASSWORDorIPMITOOL_PASSWORD. TheIPMITOOL_PASSWORDtakes precedence.-f <password_file>β Specifies a file containing the remote server password. If this option is absent, or ifpassword_fileis empty, the password will default to NULL.-gβ Deprecated. Use:-o intelplus-hβ Get basic usage help from the command line.-H <address>β Remote server address, can be IP address or hostname. This option is required forlanandlanplusinterfaces. non-negotiable, you need it π«‘-I <interface>β Selects IPMI interface to use. Supported interfaces that are compiled in are visible in the usage help output.-k <key>β Use supplied Kg key for IPMIv2.0 authentication. The default is not to use any Kg key.-Kβ Read Kg key fromIPMI_KGKEYenvironment variable.-l <lun>β Set destination lun for raw commands.-L <privlvl>β Force session privilege level. Can beCALLBACK,USER,OPERATOR,ADMINISTRATOR. Default isADMINISTRATOR. This value is ignored and always set toADMINISTRATORwhen combined with-ttarget address. (the-toption said "hold my crown" π)-m <local_address>β Set the local IPMB address. The local address defaults to0x20or is auto discovered on PICMG platforms when-mis not specified. There should be no need to change the local address for normal operation. like fr, leave it alone π-N <sec>β Specify nr. of seconds between retransmissions oflan/lanplusmessages. Defaults are2seconds forlanand1second forlanplusinterfaces. Commandrawuses fixed value of15seconds. Commandsoluses fixed value of1second.-o <oemtype>β Select OEM type to support. This usually involves minor hacks in place in the code to work around quirks in various BMCs from various manufacturers. Use-o listto see a list of current supported OEM types.-O <sel oem>β Open selected file and read OEM SEL event descriptions to be used during SEL listings. See examples incontribdir for file format.-p <port>β Remote server UDP port to connect to. Default is623.-P <password>β Remote server password is specified on the command line. If supported it will be obscured in the process list. Note! Specifying the password as a command line option is not recommended.-R <count>β Set the number of retries forlan/lanplusinterface (default=4). Commandrawuses fixed value of one try (no retries). Commandhpmuses fixed value of10retries.-sβ Deprecated. Use:-o supermicro-S <sdr_cache_file>β Use local file for remote SDR cache. Using a local SDR cache can drastically increase performance for commands that require knowledge of the entire SDR to perform their function. Local SDR cache from a remote system can be created with thesdr dumpcommand. it's giving β¨speedβ¨-t <target_address>β Bridge IPMI requests to the remote target address. Default is32. The-L privlvloption is always ignored and value set toADMINISTRATOR.-T <address>β Set transit address for bridge request (dual bridge).-T <transmit_address>β Set transit address for bridge request. (dual bridge) (again, listed twice in the source, we do not gatekeep π)-U <username>β Remote server username, default is NULL user.-vβ Increase verbose output level. This option may be specified multiple times to increase the level of debug output. If given three times you will get hexdumps of all incoming and outgoing packets. Using it five times provides details on request and expected reply processing. Thehpmcommandstargetcapcomppropabortupgstatusrollbackrollbackstatusselftestresultincreases the verbosity level.-Vβ Display version information.-y <hex key>β Use supplied Kg key for IPMIv2.0 authentication. The key is expected in hexadecimal format and can be used to specify keys with non-printable characters. E.g.'-k PASSWORD'and'-y 50415353574F5244'are equivalent. The default is not to use any Kg key.-Yβ Prompt for the Kg key for IPMIv2.0 authentication.-z <size>β Change Size of Communication Channel. (OEM)
If no password method is specified then ipmitool will prompt the user for a password. If no password is entered at the prompt, the remote server password will default to NULL. so, like, don't just mash enter and act surprised π
π₯ SECURITY π₯
okay bestie, this section is the "please take this seriously" section, no cap.
There are several security issues be be considered before enabling the IPMI LAN interface. A remote station has the ability to control a system's power state as well as being able to gather certain platform information. To reduce vulnerability it is strongly advised that the IPMI LAN interface only be enabled in 'trusted' environments where system security is not an issue or where there is a dedicated secure 'management network'. literally the whole power state. respect the LAN interface π«Ά
Further it is strongly advised that you should not enable IPMI for remote access without setting a password, and that that password should not be the same as any other password on that system. (yes, reusing passwords is still a crime, we've been over this π)
When an IPMI password is changed on a remote machine with the IPMIv1.5 lan interface the new password is sent across the network as clear text. This could be observed and then used to attack the remote system. It is thus recommended that IPMI password management only be done over IPMIv2.0 lanplus interface or the system interface on the local station. clear text!! in the group chat!! no π
For IPMI v1.5, the maximum password length is 16 characters; longer passwords might be truncated or rejected by the server, or rejected by ipmitool.
For IPMI v2.0, the maximum password length is 20 characters; longer passwords will be rejected by ipmitool.
π COMMANDS π
helpβ This can be used to get command-line help onipmitoolcommands. It may also be placed at the end of commands to get option usage help. the icon that it is π
and that's just the very first command on the list β there's a whole buffet of them waiting, so stay tuned bestie π
K so real talk: ipmitool help is your little map of everything the tool can do, and it lowkey prints this exact list. Copy-paste safe, character for character:
> ipmitool help
Commands:
bmc Deprecated. Use mc
channel Configure Management Controller channels
chassis Get chassis status and set power state
dcmi Data Center Management Interface
delloem Manage Dell OEM Extensions.
echo Used to echo lines to stdout in scripts
ekanalyzer run FRU-Ekeying analyzer using FRU files
event Send events to MC
exec Run list of commands from file
firewall Configure Firmware Firewall
fru Print built-in FRU and scan for FRU locators
fwum Update IPMC using Kontron OEM Firmware
Update Manager
gendev Read/Write Device associated with Generic
Device locators sdr
hpm Update HPM components using PICMG HPM.1 file
i2c Send an I2C Master Write-Read command and
print response
ime Upgrade/Query Intel ME firmware
isol Configure and connect Intel IPMIv1.5
Serial-over-LAN
kontronoem Manage Kontron OEM Extensions
lan Configure LAN Channels
mc Management Controller status and global
enables
nm Node Manager
pef Configure Platform Event Filtering (PEF)
picmg Run a PICMG/ATA extended command
power Shortcut to chassis power commands
raw Send a RAW IPMI request and print response
sdr Print Sensor Data Repository entries and
readings
sel Print System Event Log (SEL)
sensor Print detailed sensor information
session Print session information
set Set runtime variable for shell and exec
shell Launch interactive IPMI shell
sol Configure and connect IPMIv2.0
Serial-over-LAN
spd Print SPD info from remote I2C device
sunoem Manage Sun OEM Extensions
tsol Configure and connect Tyan IPMIv1.5
Serial-over-LAN
user Configure Management Controller users
Now the vibe check on each one, bestie, so you know what you're picking up:
bmcβ β¨ deprecated β¨. It literally saysDeprecated. Use mc. So usemc, ok? Not me still seeing people typebmcin 2024 π.channelβ configure management controller channels. Your whole comms setup lives here.chassisβ get chassis status and set power state. The classic "is it on, can I turn it off" zone.dcmiβ Data Center Management Interface. Very data-center, very serious.delloemβ manage Dell OEM extensions. Dell-specific club πechoβ used to echo lines tostdoutin scripts. Baby's first script tool, iconic.ekanalyzerβ run FRU-Ekeying analyzer using FRU files. Niche, but she's valid.eventβ send events to MC.execβ run a list of commands from a file. Batch mode nation π«Άfirewallβ configure Firmware Firewall. Security girlie.fruβ print built-in FRU and scan for FRU locators.fwumβ update IPMC using Kontron OEM Firmware Update Manager.gendevβ read/write device associated with generic device locators sdr.hpmβ update HPM components using a PICMG HPM.1 file.i2cβ send an I2C master write-read command and print the response.imeβ upgrade/query Intel ME firmware.isolβ configure and connect Intel IPMIv1.5 Serial-over-LAN.kontronoemβ manage Kontron OEM extensions.lanβ configure LAN channels.mcβ management controller status and global enables. (This is the one. The main character.)nmβ Node Manager.pefβ configure Platform Event Filtering (PEF).picmgβ run a PICMG/ATA extended command.powerβ shortcut to thechassis powercommands, no cap.rawβ send a RAW IPMI request and print the response. Powerful, slightly feral π₯sdrβ print Sensor Data Repository entries and readings.selβ print the System Event Log (SEL).sensorβ print detailed sensor information.sessionβ print session information.setβ set a runtime variable forshellandexec.shellβ launch the interactive IPMI shell.solβ configure and connect IPMIv2.0 Serial-over-LAN.spdβ print SPD info from a remote I2C device.sunoemβ manage Sun OEM extensions.tsolβ configure and connect Tyan IPMIv1.5 Serial-over-LAN.userβ configure management controller users.
πΈ channel πΈ
authcap <channel number> <max priv>
Shows you the authentication capabilities of the channel you picked, at the privilege level you picked. Simple, honest, slays.
The possible privilege levels are, and yes you need to memorise these:
1 Callback level
2 User level
3 Operator level
4 Administrator level
5 OEM Proprietary level
15 No access
Ngl the jump from5to15is such a choice, but that's the spec, not me π.
info [channel number]
Tells you everything about the chosen channel. Don't pass a channel number? It just shows you info about whatever channel is currently in use. Lowkey convenient.
> ipmitool channel info
Channel 0xf info:
Channel Medium Type : System Interface
Channel Protocol Type : KCS
Session Support : session-less
Active Session Count : 0
Protocol Vendor ID : 7154
Look at her go. 0xf, KCS, session-less, zero active sessions β a whole mood π
.
getaccess <channel number> [<userid>]
Sets the given userid as the default on that channel number. Then whenever that channel gets used later, the user is identified implicitly by that userid. So it's like... pre-booking the identity. Cute.
setaccess <channel number> <userid> [<callin=on|off>] [<ipmi=on|off>] [<link=on|off>] [<privilege=level>]
Configures the access info for that userid on that channel. Everything in brackets is optional, so take what you need:
callin=on|offipmi=on|offlink=on|offprivilege=level
getciphers <ipmi|sol> [<channel>]
Spits out the list of cipher suites supported for the app you name β ipmi or sol β on the channel you name. Cipher shopping, but make it secure π.
π chassis π
status
Status info related to power, buttons, cooling, drives and faults. The whole vibe check of the physical box.
power
The power moves, and here's the full menu:
statusonoffcycleresetdiagsoft
That's it. That's the list. Pick your fighter π.
identify [<seconds>|force]
The identify interval β you know, the "which server am I even looking at" light.
- Default is
15seconds. 0β off.forceβ turn it on indefinitely.
policy
What should happen when power gets restored? Big philosophical question, honestly.
listβ show the available options.always-onpreviousalways-off
restart_cause
Shows the last restart cause. Receipts for why it rebooted π.
poh
Get power on hours. How long has she been awake. π
bootdev
Where should this thing boot from? The options:
noneβ do not change boot device order.pxeβ force PXE boot.diskβ force boot from default hard-drive.safeβ force boot from default hard-drive, request Safe Mode.diagβ force boot from Diagnostic Partition.cdromβ force boot from CD/DVD.biosβ force boot into BIOS Setup.floppyβ force boot from Floppy/primary removable media.
bootmbox get [text] [block <block#>]
Reads the Boot Initiator Mailbox, either as a hex dump or in text mode (that's what the text bit is for).
By default the whole mailbox gets read. But if you give a block number, only that particular block gets read. And heads up: for block 0, or when you're reading the whole mailbox, it also prints the Boot Initiator IANA Enterprise Number plus the matching enterprise name. Extra info, no extra charge β¨.
bootmbox set text [block <block#>] <IANA_PEN> "<data_string>"
Writes either the specified <block> or the entire Boot Initiator Mailbox, in text mode.
You must give a decimal IANA Enterprise Number that the boot initiator on the target system actually recognises β check with your target system manufacturer for the details, bestie, I can't guess that for you. Everything after that is a text string.
Real talk warning π¨: when you request a single block write, the total length of<data>may not exceed13bytes for block0, or16bytes otherwise. Overshoot and it's not gonna be cute.
bootmbox set [block <block#>] <IANA_PEN> <data_byte> [<data_byte> ...]
Same thing as above, except the arguments after the IANA PEN are separate data byte values, each separated by spaces.
bootparam get <opt_id> [<opt_param>]
Gets the value of system boot option number <opt_id>. Some boot options (option 7, for example) can also take an optional numeric parameter, which is what <opt_param> is for.
bootparam set bootflag <device> [options=...]
Sets a boot flag. The valid devices:
force_pxeβ force PXE boot.force_diskβ force boot from default hard-drive.force_safeβ force boot from default hard-drive, request Safe Mode.force_diagβ force boot from Diagnostic Partition.force_cdromβ force boot from CD/DVD.force_biosβ force boot into BIOS Setup.
And the valid options:
PEFβ clear the valid bit on reset/power cycle caused by PEF.timeoutβ automatically clear the boot flag valid bit on timeout.watchdogβ clear the valid bit on reset/power cycle caused by watchdog.resetβ clear the valid bit on push button reset/soft reset.powerβ clear the valid bit on power up via power push button or wake event.
selftest
Gets the chassis self-test results. Is she okay? Let's find out π«Ά.
π dcmi π
discover
Used to discover the capabilities supported in DCMI. It's the "what can you even do" command.
power <command>
The platform power limit commands are:
readingβ get power related readings from the system.get_limitβ get the configured power limits.set_limit <parameter> <value>β set a power limit option.activateβ activate the set power limit.deactivateβ deactivate the set power limit.
And the possible parameters/values for set_limit, since this is the messy part:
action <No Action | Hard Power Off & Log Event to SEL | Log Event to SEL>β the exception action taken is either "No Action", "Hard Power Off system and log events to SEL", or "Log event to SEL only".limit <number in Watts>β the power limit requested, in Watts.correction <number in milliseconds>β the correction time limit, in milliseconds.sample <number in seconds>β the statistics sampling period, in seconds.
sensors
Prints the available DCMI sensors.
asset_tag
Prints the platform's asset tag. Name tag energy π·οΈ.
set_asset_tag <string>
Sets the platform's asset tag.
get_mc_id_string
Gets the management controller identifier string.
set_mc_id_string <string>
Sets the management controller identifier string. The maximum length is 64 bytes, and that includes a null terminator β so don't go spending all 64 on your cute nickname π.
thermalpolicy [<get | set>]
Thermal Limit policy get/set. The commands are:
Get <entityID> <instanceID>β get Thermal Limit values.
entityID is the physical entity that a sensor or device is associated with β like, which thing are we even talking about. instanceID is a particular instance of an entity. Entity Instance can live in one of two ranges: system-relative or device-relative. For example, a system with four processors could use an Entity Instance value of "0" to identify the first processor. π«Ά
Set <entityID> <instanceID>β Set Thermal Limit values. π₯
Ngl, the next bit is literally the same paragraph again, but your girl doesn't skip lore: entityID is the physical entity that a sensor or device is associated with, and instanceID is a particular instance of an entity. Entity Instance can be in one of two ranges, system-relative or device-relative. For example, a system with four processors could use an Entity Instance value of "0" to identify the first processor. (yes bestie, "0" = first processor, iconic numbering) π
get_temp_readingβ Get Temperature Sensor Readings. π‘οΈget_conf_paramβ Get DCMI Configuration Parameters. βοΈset_conf_param <parameters>β Set DCMI Configuration Parameters.
The Configuration Parameters are:
activate_dhcpβ Activate/restart DHCP. πdhcp_configβ Discover DHCP Configuration.initβ Set DHCP Initial timeout interval, in seconds. The recommended default is four seconds.timeoutβ Set DHCP Server contact timeout interval, in seconds. The recommended default timeout is two minutes.retryβ Set DHCP Server contact retry interval, in seconds. The recommended default timeout is sixty-four seconds.
oob_discoverβ Ping/Pong Message for DCMI Discovery. π
π¦ delloem π
The delloem commands provide information on Dell-specific features. It's giving "Dell said lemme add my own commands" energy, and honestly? Respect. π
π setled {b:d.f} {state..}
Sets the drive backplane LEDs for a device.
{b:d.f}= PCI Address of device (eg.06:00.0){state}= one or more of the following:online|present|hotspare|identify|rebuilding|fault|predict|critical|failed
π lcd
set {mode}|{lcdqualifier}|{errordisplay} β Allows you to set the LCD mode and user-defined string.
Then the individual LCD moves, in all their glory:
lcd set mode {none}|{modelname}|{ipv4address}|{macaddress}|{systemname}|{servicetag}|{ipv6address}|{ambienttemp}|{systemwatt}|{assettag}|{userdefined}<text>
Allows you to set the LCD display mode to any of the preceding parameters.
lcd set lcdqualifier {watt}|{btuphr}|{celsius}|{fahrenheit}
Allows you to set the unit for the system ambient temperature mode.
lcd set errordisplay {sel}|{simple}
Allows you to set the error display.
lcd info β Displays the LCD screen information. πΊ
lcd set vkvm {active}|{inactive}
Allows you to set the vKVM status to active or inactive. When it is active and session is in progress, a message appears on LCD.
lcd status β Displays the LCD status for vKVM display active or inactive and Front Panel access mode (viewandmodify, view-only or disabled). No cap, that's a whole vibe check of your front panel right there.
πΈ mac
Displays the information about the system NICs.
mac list β Displays the NIC MAC address and status of all NICs. It also displays the DRAC/iDRAC MAC address. π§
mac get <NIC number> β Displays the selected NICs MAC address and status.
β lan
Displays the information of Lan.
lan set <Mode> β Sets the NIC selection mode (dedicated, shared with lom1, shared with lom2, shared with lom3, shared with lom4, shared with failover lom1, shared with failover lom2, shared with failover lom3, shared with failover lom4, shared with Failover all loms, shared with Failover None).
lan get β Returns the current NIC selection mode (dedicated, shared with lom1, shared with lom2, shared with lom3, shared with lom4, shared with failover lom1, shared with failover lom2, shared with failover lom3, shared with failover lom4, shared with Failover all loms, shared with Failover None).
lan get active β Returns the current active NIC (dedicated, LOM1, LOM2, LOM3 or LOM4).
π₯ powermonitor
Displays power tracking statistics.
powermonitor clear cumulativepower β Reset cumulative power reading.
powermonitor clear peakpower β Reset peak power reading.
powermonitor powerconsumption <watt>|<btuphr> β Displays the power consumption in watt or btuphr.
powermonitor powerconsumptionhistory <watt>|<btuphr> β Displays the power consumption history in watt or btuphr.
powermonitor getpowerbudget <watt>|<btuphr> β Displays the power cap in watt or btuphr.
powermonitor setpowerbudget <val><watt|btuphr|percent> β Allows you to set the power cap in watt, BTU/hr or percentage.
powermonitor enablepowercap β Enables set power cap. β‘
powermonitor disablepowercap β Disables set power cap.
π vFlash info Card
Shows Extended SD Card information. π
β¨ echo π
For echoing lines to stdout in scripts. Tiny command, big main character energy β your scripts said "I need a little guy to just print things" and echo delivered.
π§ ekanalyzer π«
ekanalyzer <command> <xx=filename1> <xx=filename2> [<rc=filename3>] ...
NOTE: This command can support a maximum of 8 files per command line. Eight. Not nine. Bestie, don't push it. π
Here's who's who in that command line:
filename1β binary file that stores FRU data of a Carrier or an AMC modulefilename2β binary file that stores FRU data of an AMC module. These binary files can be generated from command:ipmitool fru read <id> <filename>filename3β configuration file used for configuring On-Carrier Device ID or OEM GUID. This file is optional.
And xx? It indicates the type of the file. It can take the following value:
ocβ On-Carrier devicea1β AMC slot A1a2β AMC slot A2a3β AMC slot A3a4β AMC slot A4b1β AMC slot B1b2β AMC slot B2b3β AMC slot B3b4β AMC slot B4smβ Shelf Manager
The available commands for ekanalyzer are:
π print [<carrier | power | all>]
carrier (default) <oc=filename1> <oc=filename2> ... β Display point to point physical connectivity between carriers and AMC modules.
Example, served fresh:
> ipmitool ekanalyzer print carrier oc=fru oc=carrierfru
From Carrier file: fru
Number of AMC bays supported by Carrier: 2
AMC slot B1 topology:
Port 0 =====> On Carrier Device ID 0, Port 16
Port 1 =====> On Carrier Device ID 0, Port 12
Port 2 =====> AMC slot B2, Port 2
AMC slot B2 topology:
Port 0 =====> On Carrier Device ID 0, Port 3
Port 2 =====> AMC slot B1, Port 2
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
From Carrier file: carrierfru
On Carrier Device ID 0 topology:
Port 0 =====> AMC slot B1, Port 4
Port 1 =====> AMC slot B1, Port 5
Port 2 =====> AMC slot B2, Port 6
Port 3 =====> AMC slot B2, Port 7
AMC slot B1 topology:
Port 0 =====> AMC slot B2, Port 0
AMC slot B1 topology:
Port 1 =====> AMC slot B2, Port 1
Number of AMC bays supported by Carrier: 2
Look at all those arrows. The topology ate and left no crumbs. π«Ά
power <xx=filename1> <xx=filename2> ... β Display power supply information between carrier and AMC modules.
all <xx=filename> <xx=filename> ... β Display both physical connectivity and power supply of each carrier and AMC modules. The "why not both" option, honestly iconic. π
π frushow <xx=filename>
Convert a binary FRU file into human readable text format. Use -v option to get more display information. π
β summary [<match | unmatch | all>]
match(this one's the default, so if you don't say anything else it's what you get π )<xx=filename><xx=filename>... β shows you only the matched results of the Ekeying match, whether it's between an On-Carrier device and an AMC module, or between 2 AMC modules. Like, the "y'all actually line up" report β¨
Example, because a picture is worth a thousand words:
> ipmitool ekanalyzer summary match oc=fru b1=amcB1 a2=amcA2
On-Carrier Device vs AMC slot B1
AMC slot B1 port 0 ==> On-Carrier Device 0 port 16
Matching Result
- From On-Carrier Device ID 0
-Channel ID 11 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
- To AMC slot B1
-Channel ID 0 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
AMC slot B1 port 1 ==> On-Carrier Device 0 port 12
Matching Result
- From On-Carrier Device ID 0
-Channel ID 6 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
- To AMC slot B1
-Channel ID 1 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
On-Carrier Device vs AMC slot A2
AMC slot A2 port 0 ==> On-Carrier Device 0 port 3
Matching Result
- From On-Carrier Device ID 0
-Channel ID 9 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
- To AMC slot A2
-Channel ID 0 || Lane 0: enable
-Link Type: AMC.2 Ethernet
-Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
-Link Group ID: 0 || Link Asym. Match: exact match
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
AMC slot B1 vs AMC slot A2
AMC slot A2 port 2 ==> AMC slot B1 port 2
Matching Result
- From AMC slot B1
-Channel ID 2 || Lane 0: enable
-Link Type: AMC.3 Storage
-Link Type extension: Serial Attached SCSI (SAS/SATA)
-Link Group ID: 0 || Link Asym. Match: FC or SAS interface {exact match}
- To AMC slot A2
-Channel ID 2 || Lane 0: enable
-Link Type: AMC.3 Storage
-Link Type extension: Serial Attached SCSI (SAS/SATA)
-Link Group ID: 0 || Link Asym. Match: FC or SAS interface {exact match}
*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
unmatch<xx=filename><xx=filename>... β the opposite vibe π«Ά shows you the unmatched results of the Ekeying match, again between an On-Carrier device and an AMC module, or between 2 AMC modules. It's giving "these two are not seeing each other".all<xx=filename><xx=filename>... β the whole story, bestie: displays both the matched results and the unmatched results of the Ekeying match between two cards or two modules π₯
π event π
<predefined event number N> πΈ
Sends a pre-defined test event into the System Event Log. The events below are there as a way to test that the System Event Log component of the BMC is actually, like, functioning (an entry gets added every single time the event N command runs π).
Currently supported values for N are:
1β Temperature: Upper Critical: Going High2β Voltage Threshold: Lower Critical: Going Low3β Memory: Correctable ECC
NOTE: these pre-defined events will likely not produce "accurate" SEL records for a particular system, because they aren't correctly tied to a valid sensor number β but they're still plenty to verify correct operation of the SEL. So don't come for them π
file <filename> π¦
Event log records specified in <filename> will be added to the System Event Log.
The format of each line in the file is as follows:
<{EvM Revision} {Sensor Type} {Sensor Num} {Event Dir/Type} {Event Data 0} {Event Data 1} {Event Data 2}>[# COMMENT]
e.g.:
0x4 0x2 0x60 0x1 0x52 0x0 0x0 # Voltage threshold: Lower Critical: Going Low
Field-by-field, because ikyk y'all want the deets:
- EvM Revision β the "Event Message Revision" is
0x04for messages that comply with the IPMI 2.0 Specification and0x03for messages that comply with the IPMI 1.0 Specification. - Sensor Type β tells you the Event Type or Class.
- Sensor Num β represents the 'sensor' within the management controller that generated the Event Message.
- Event Dir/Type β this field is encoded with the event direction as the high bit (bit 7) and the event type as the low 7 bits. Event direction is
0for an assertion event and1for a deassertion event.
See the IPMI 2.0 specification for further details on the definitions for each field π
<sensorid> <list> β¨
Gets you a list of all the possible Sensor States and the pre-defined Sensor State Shortcuts available for a particular sensor. sensorid is the character string representation of the sensor, and it must be enclosed in double quotes if it includes white space. Several different commands, including ipmitool sensor list, can be used to obtain a list that includes the sensorid strings representing the sensors on a given system π«Ά
> ipmitool -I open event "PS 2T Fan Fault" list
Finding sensor PS 2T Fan Fault... ok
Sensor States:
State Deasserted
State Asserted
Sensor State Shortcuts:
present absent
assert deassert
limit nolimit
fail nofail
yes no
on off
up down
<sensorid> <sensor state> [<direction>] π
Generates a custom event based on existing sensor info. That optional event direction can be either assert (the default, if you don't say anything) or deassert.
> ipmitool event "PS 2T Fan Fault" "State Asserted"
Finding sensor PS 2T Fan Fault... ok
0 | Pre-Init Time-stamp | Fan PS 2T Fan Fault | State Asserted
> ipmitool event "PS 2T Fan Fault" "State Deasserted"
Finding sensor PS 2T Fan Fault... ok
0 | Pre-Init Time-stamp | Fan PS 2T Fan Fault | State Desserted
(yes, Desserted is literally what it prints β no cap, that's the output, we don't fix it π)
π exec π
exec <filename> β runs ipmitool commands straight out of filename. Each line is a complete command, and the syntax of those commands is defined by the COMMANDS section in this manpage. Every line may have an optional comment at the end of the line, delimited with a # symbol π
e.g., a command file with two lines:
sdr list # get a list of sdr records
sel list # get a list of sel records
π₯ firewall π₯
This command supports the Firmware Firewall capability. Use it to add or remove security-based restrictions on certain commands/command sub-functions, or to list the current firmware firewall restrictions set on any commands. For each firmware firewall command listed below, parameters may be included to make the command execute with increasing granularity β on a specific LUN, for a specific NetFn, for a specific IPMI Command, and finally for a specific command's sub-function (peep Appendix H in the IPMI 2.0 Specification for a listing of any sub-function numbers that may be associated with a particular command π).
Parameter syntax and dependencies are as follows:
[<channel H>] [<lun L> [ <netfn N> [<command C [<subfn S>]]]]
Heads up bestie: ifnetfn <N>is specified, thenlun <L>must also be specified; ifcommand <C>is specified, thennetfn <N>(and thereforelun <L>) must also be specified, and so forth. The nesting is real π
channel <H> is an optional and standalone parameter. If you don't specify it, the requested operation happens on the current channel. Note that command support may vary from channel to channel β it's giving "every channel's got its own personality" π
Firmware firewall commands:
info [<Parms as described above>] β
Lists firmware firewall information for the specified LUN, NetFn, and Command (if supplied) on the current or specified channel. The listed information includes the support, configurable, and enabled bits for the specified command or commands π
Some usage examples:
info [<channel H>] [<lun L>]β this one lists firmware firewall info for all NetFns for the specified LUN on either the current channel or the channel you specify. πinfo [<channel H>] [<lun L> [ <netfn N> ]β this prints out all command information for a single LUN/NetFn pair.info [<channel H>] [<lun L> [ <netfn N> [<command C] ]]β this prints detailed, human-readable info showing the support, configurable, and enabled bits for the specified command on the specified LUN/NetFn pair. Info gets printed about each of the command subfunctions. β¨info [<channel H>] [<lun L> [ <netfn N> [<command C [<subfn S>]]]]β print out information for a specific sub-function.enable [<Parms as described above>]β enables commands for a given NetFn/LUN combination on the specified channel.disable [<Parms as described above>] [force]β disables commands for a given NetFn/LUN combination on the specified channel. Great care should be taken if using theforceoption so as not to disable theSet Command Enablescommand. πreset [<Parms as described above>]β resets the firmware firewall back to a state where all commands and command sub-functions are enabled. π«Ά
π fru β Field Replaceable Unit era
printβ read all Field Replaceable Unit (FRU) inventory data and extract stuff like serial number, part number, asset tags, and short strings describing the chassis, board, or product.read <fru id> <fru file>βfru idis the digit ID of the FRU (see output offru print).fru fileis the absolute pathname of a file to dump the binary FRU data pertaining to the specified FRU entity into.write <fru id> <fru file>βfru idis the digit ID of the FRU (see output offru print).fru fileis the absolute pathname of a file to pull the binary FRU data from before uploading it to the specified FRU.upgEkey <fru id> <fru file>β update a multirecord FRU location.fru idis the digit ID of the FRU (see output offru print).fru fileis the absolute pathname of a file to pull the binary FRU data from to upload into the specified multirecord FRU entity.edit <fru id>β provides interactive editing of some supported records, namely PICMG Carrier Activation Record.fru idis the digit ID of the FRU (see output offru print); default is0.edit <fru id> field <section> <index> <string>β sets a field string to a new value. It replaces the FRU data found at index in the specified section with the supplied string.
fru id is the digit ID of the FRU (see output of fru print).
<section> is a string which refers to FRU Inventory Information Storage Areas and may refer to:
cβ FRU Inventory Chassis Info Areabβ FRU Inventory Board Info Areapβ FRU Inventory Product Info Area
<index> specifies the field number. Field numbering starts on the first 'english text' field type. For instance in the <board> info area field 0 is <Board Manufacturer> and field 2 is <Board Serial Number>; see IPMI Platform Management FRU Information Storage Definition v1.0 R1.1 for field locations.
<string> must be the same length as the string being replaced and must be 8-bit ASCII (0xCx).
edit <fru id> oem iana <record> <format> [<args>]β edits the data found in the multirecord area. Support for OEM specific records is limited.
π§ fwum β Kontron OEM firmware update manager
Update IPMC using Kontron OEM Firmware Update Manager. π
infoβ show information about current firmware.statusβ show status of each firmware bank present in the hardware.download <filename>β download specified firmware.upgrade [filename]β install firmware upgrade. If the filename is specified, the file is downloaded first, otherwise the last firmware downloaded is used.rollbackβ ask IPMC to rollback to previous version.tracelogβ show firmware upgrade log.
π¦ gendev β generic device locators
listβ list all Generic Device Locators.read <sdr name> <file>β read to a file the eeprom specified by Generic Device Locators.write <sdr name> <file>β write from a file to the eeprom specified by Generic Device Locators.
π hpm β PICMG HPM.1 Upgrade Agent
checkβ check the target information.check <filename>β display both the existing target version and image version on the screen.download <filename>β download specified firmware.upgrade <filename> [all] [component <x>] [activate]β upgrade the firmware using a valid HPM.1 image file. If no option is specified, the firmware versions are checked first and the firmware is upgraded only if they are different.allβ upgrade all components even if the firmware versions are the same (use this only after usingcheckcommand).component <x>β upgrade only the given component from the given file.component 0β BOOTcomponent 1β RTK
activateβ activate new firmware right away.
activateβ activate the newly uploaded firmware.targetcapβ get the target upgrade capabilities.compprop <id> <select>β get the specified component properties. Valid component id:0-7.selectcan be one of the following:0β General properties1β Current firmware version2β Description string3β Rollback firmware version4β Deferred firmware version
abortβ abort the on-going firmware upgrade.upgstatusβ show status of the last long duration command.rollbackβ perform manual rollback on the IPM Controller firmware.rollbackstatusβ show the rollback status.selftestresultβ query the self test results.
π i2c <i2caddr> <read bytes> [<write data>]
This command may be used to execute raw I2C commands with the Master Write-Read IPMI command. β‘
π ime β Manageability Engine
helpβ print usage information.infoβ displays information about the Manageability Engine (ME).update <file>β upgrade the ME firmware with the specified image file. WARNING: You MUST use a supported image provided by your board vendor. πrollbackβ perform manual rollback of the ME firmware.
πΈ isol β Intel IPMI v1.5 Serial-over-LAN
infoβ retrieve information about the Intel IPMI v1.5 Serial-Over-LAN configuration.set <parameter> <value>β configure parameters for Intel IPMI v1.5 Serial-over-LAN. Valid parameters and values are:enabledβtrue,false.privilege-levelβuser,operator,admin,oem.bit-rateβ9.6,19.2,38.4,57.6,115.2.
activateβ causesipmitoolto enter Intel IPMI v1.5 Serial Over LAN mode. An RMCP+ connection is made to the BMC, the terminal is set to raw mode, and user input is sent to the serial console on the remote server. On exit, the SOL payload mode is deactivated and the terminal is reset to its original settings.
Special escape sequences are provided to control the SOL session:
~.β terminate connection~^Zβ suspendipmitool~^Xβ suspendipmitool, but don't restore tty on restart~Bβ send break~~β send the escape character by typing it twice~?β print the supported escape sequences
Note that escapes are only recognized immediately after newline. π«Ά
β kontronoem β OEM commands specific to Kontron devices
setsnβ set FRU serial number.setmfgdateβ set FRU manufacturing date.nextboot <boot device>β select the next boot order on the Kontron CP6012.
π lan β LAN channel configuration
These commands will allow you to configure IPMI LAN channels with network information so they can be used with the lan and lanplus interfaces.
NOTE: To determine on which channel the LAN interface is located, issue the channel info number command until you come across a valid 802.3 LAN channel. For example:
> ipmitool -I open channel info 1
Channel 0x1 info:
Channel Medium Type : 802.3 LAN
Channel Protocol Type : IPMB-1.0
Session Support : session-based
Active Session Count : 8
Protocol Vendor ID : 7154
print [<channel>]
Print the current config for the channel you point at β and if you just don't specify one, it'll slide into the first LAN channel it finds and print that. Comfy default, tbh.
π οΈ set <channel number> <command> <parameter>
Okay so this one sets the command and parameter on the channel you name. Valid command/parameter combos, bestie, are these:
ipaddr <x.x.x.x>β sets the IP address for this channel. literally the main character of network config.netmask <x.x.x.x>β sets the netmask for this channel.macaddr <xx:xx:xx:xx:xx:xx>β sets the MAC address for this channel.defgw ipaddr <x.x.x.x>β sets the default gateway IP address.defgw macaddr <xx:xx:xx:xx:xx:xx>β sets the default gateway MAC address.bakgw ipaddr <x.x.x.x>β sets the backup gateway IP address. the understudy gateway πbakgw macaddr <xx:xx:xx:xx:xx:xx>β sets the backup gateway MAC address.password <pass>β sets the null user password.snmp <community string>β sets the SNMP community string.userβ enables user access mode for userid 1 (go issue theusercommand to display info about userids for a given channel, iykyk).access <on|off>β sets the LAN channel access mode.alert <on|off>β enables or disables PEF alerting for this channel.ipsrc <source>β sets the IP address source. the options are:noneβ unspecifiedstaticβ manually configured static IP addressdhcpβ address obtained by BMC running DHCPbiosβ address loaded by BIOS or system software
arp respond <on|off>β sets BMC generated ARP responses.arp generate <on|off>β sets BMC generated gratuitous ARPs.arp interval <seconds>β sets the BMC generated gratuitous ARP interval.vlan id <off|id>β disables VLAN operation, or enables VLAN and sets the ID. the ID is the value of the virtual lan identifier between 1 and 4094 inclusive. π¦vlan priority <priority>β sets the priority associated with VLAN frames. ID: priority of the virtual lan frames between 0 and 7 inclusive.auth <level,...> <type,...>β sets the valid authtypes for a given auth level.- Levels:
callback,user,operator,admin - Types:
none,md2,md5,password,oem
- Levels:
cipher_privs <privlist>β correlates cipher suite numbers with the maximum privilege level allowed to use it. so basically you can restrict cipher suites to users with a given privilege level β meaning, for example, admins are required to use a stronger cipher suite than normal users. gatekeeping, but make it security π
The format of privlist is as follows: each character represents a privilege level, and the character position identifies the cipher suite number. So like, the first character represents cipher suite 0, the second represents cipher suite 1, and so on. privlist must be 15 characters long. no more, no less.
Characters used in privlist and their associated privilege levels:
Xβ Cipher Suite Unusedcβ CALLBACKuβ USERoβ OPERATORaβ ADMINOβ OEM
So, to set the maximum privilege for cipher suite 0 to USER and suite 1 to ADMIN, you'd issue this:
> ipmitool -I interface lan set channel cipher_privs uaXXXXXXXXXXXXX
bad_pass_thresh <thresh_num> <1|0> <reset_interval> <lockout_interval>β sets the Bad Password Threshold. the deets:<thresh_num>β if non-zero, this value determines the number of sequential bad passwords that will be allowed to be entered for the identified user before the user is automatically disabled from access on the channel.<1|0>β1= generate a Session Audit sensor "Invalid password disable" event message.0= do not generate an event message when the user is disabled.<reset_interval>β Attempt Count Reset Interval. the interval, in tens of seconds, for which the accumulated count of bad password attempts is retained before being automatically reset to zero.<lockout_interval>β User Lockout Interval. the interval, in tens of seconds, that the user will remain disabled after being disabled because the Bad Password Threshold number was reached. π
π¨ alert print [<channel>] [<alert destination>]
Prints alert info for the specified channel and destination. default behavior prints all alerts for all alert destinations on the first found LAN channel. the full scroll, bestie.
π¨ alert set <channel number> <alert destination> <command> <parameter>
Sets an alert on the given LAN channel and destination. you can see your Alert Destinations via the lan alert print command. valid command/parameter options:
ipaddr <x.x.x.x>β sets alert IP address.macaddr <xx:xx:xx:xx:xx:xx>β sets alert MAC address.gateway <default | backup>β sets the channel gateway to use for alerts.ack <on | off>β turns Alert Acknowledge on or off.type <pet | oem1 | oem2>β sets the destination type as PET or OEM.time <seconds>β sets ack timeout or unack retry interval.retry <number>β sets the number of alert retries.
π stats get [<channel number>]
Pulls info about the IP connections on the specified channel. default grabs statistics on the first found LAN channel. numbers go brrr π
π§Ή stats clear [<channel number>]
Clears all IP/UDP/RMCP Statistics to 0 on the specified channel. default clears statistics on the first found LAN channel. fresh start energy β¨
π» mc | bmc
π reset <warm|cold>
Instructs the BMC to perform a warm or cold reset. pick your temperature, bestie π‘οΈ
π guid [smbios|rfc4122|ipmi|dump]
Displays the Management Controller Globally Unique IDentifier. the whole encoding situation is a saga, so buckle up:
autoβ this is the default behavior foripmitool(1).
It tries to automatically detect the encoding based on the value of the version field and (for version 1) the timestamp. The version is considered valid if it is 1 through 5, and the timestamp is valid if the year is past or equal to UNIX Epoch (1970) and is before or equal to the current year.
If multiple encodings happen to have valid version fields, then precedence takes the one with version 1 and a valid timestamp. If neither one has that, then the precedence order is as follows: smbios, ipmi, rfc4122.
If neither encoding yields a valid version field, then ipmitool(1) defaults to dump mode.
If this option is in use, then ipmitool(1) will also print out the detected encoding and warn regarding IPMI specification violation if the encoding isn't ipmi. consider it a little heads up π«Ά
smbiosβ decodes the GUID as if it was sent by the BMC as prescribed by the SMBIOS specification.
NOTE: this is a violation of the IPMI specification, but many BMC implementations do it this way. If your BMC's GUID is shown correctly using this option, you may want to inform your BMC manufacturer that they have a bug. drag them, respectfully π
ipmiβ decodes the GUID according to the IPMI specification. It MUST show the correct GUID. If it doesn't, try other options and inform your BMC manufacturer of the bug.rfc4122orrfcβ decodes the GUID as if it was sent by the BMC as prescribed by the RFC4122 specification.
NOTE: this is a violation of the IPMI specification. If your BMC's GUID is shown correctly using this option, you may want to inform your BMC manufacturer that they have a bug.
dumpβ dumps as hex the data received from BMC in response to the Get Device GUID command. No decoding or interpretation is performed. First received byte is dumped first. raw and unfiltered, no cap π₯
βΉοΈ info
Displays info about the BMC hardware β including device revision, firmware revision, IPMI version supported, manufacturer ID, and info on additional device support. the whole rΓ©sumΓ© π
β±οΈ watchdog
These commands let a user view and change the current state of the watchdog timer.
get- the display one β shows the current Watchdog Timer settings and the countdown state. both bestie, at once π«Ά
resetβ resets the Watchdog Timer to its most recent state and restarts that countdown timer. fresh start energy πoffβ turns off a Watchdog countdown timer that's currently running. bye π
selftestβ checks on the basic health of the BMC by executing theGet Self Testresults command and reports the results back to you. it's giving "vibe check, but for hardware" π©Ίβ¨getenablesβ displays a list of the options that are currently enabled on the BMC. πsetenables <option>=[on|off]β enables or disables the given option.
okay important π per the IPMI specification, this command is only supported over the system interface. that's the spec talking, not me.
Currently supported values for option include:
recv_msg_intrβ Receive Message Queue Interruptevent_msg_intrβ Event Message Buffer Full Interruptevent_msgβ Event Message Buffersystem_event_logβ System Event Loggingoem0β OEM-Defined option #0oem1β OEM-Defined option #1oem2β OEM-Defined option #2
getsysinfo <argument>β retrieves system info from the bmc for the given argument. for what the arguments actually are, go look atsetsysinfoβ the definitions live there, iykyk π«‘setsysinfo <argument> <string>β stores a system info string to the bmc for the given argument. ποΈ
Possible arguments are:
primary_os_nameβ Primary Operating System Nameos_nameβ Operating System Namesystem_nameβ System Name of Serverdelloem_os_versionβ Running version of operating systemdelloem_URLβ URL of BMC Webserver
β¨ chassis β¨
whole-chassis energy, the main character of the box π
statusβ displays information regarding the high-level status of the system chassis and the main power subsystem. ποΈpohβ this command returns the Power-On Hours counter. like, how long has this thing been awake π΄β°identify <interval>β controls the front panel identify light. π‘ default interval is 15 seconds, use0to turn it off, and use"force"to turn it on indefinitely.restart_causeβ queries the chassis for the cause of the last system restart. detective mode π΅οΈββοΈselftestβ checks on the basic health of the BMC by executing theGet Self Testresults command and reports the results. same vibe check, chassis edition π©Ίpolicyβ sets the chassis power policy for the event of a power failure. β‘listβ return supported policies.always-onβ turn on when power is restored.previousβ returned to previous state when power is restored.always-offβ stay off after power is restored.
powerβ performs a chassis control command to view and change the power state. πstatusβ show current chassis power status.onβ power up chassis.offβ power down chassis into soft off (S4/S5 state).
β οΈ WARNING: this command does not initiate a clean shutdown of the operating system prior to powering down the system. fr fr, know what you're doing π
cycleβ provides a power off interval of at least 1 second. no action should occur if chassis power is in S4/S5 state, but it is recommended to check the power state first and only issue a power cycle command if the system power is on, or in a lower sleep state than S4/S5.resetβ this command performs a hard reset. π¨diagβ pulses a diagnostic interrupt (NMI) directly to the processor(s). unhinged but iconic πsoftβ initiates a soft-shutdown of the OS via ACPI. this can be done in a number of ways, commonly by simulating an overtemperture or by simulating a power button press. it's necessary for there to be Operating System support for ACPI and some sort of daemon watching for events for this soft power to work. teamwork makes the dream work π«Ά
bootdev <device> [<clear-cmos=yes|no>] [<options=help,...>]β requests the system to boot from an alternate boot device on the next reboot. the clear-cmos option, if supplied, instructs the BIOS to clear its CMOS on the next reboot. various options may be used to modify the boot device settings β runbootdev none options=helpfor a list of available boot device modifiers/options. π₯Ύ
Currently supported values for <device> are:
noneβ do not change boot devicepxeβ force PXE bootdiskβ force boot from BIOS default boot devicesafeβ force boot from BIOS default boot device, request Safe Modediagβ force boot from diagnostic partitioncdromβ force boot from CD/DVDbiosβ force boot into BIOS setupfloppyβ force boot from Floppy/primary removable media
bootparamβ get or set various system boot option parameters. βοΈget <param #>β get boot parameter. currently supported values for <param #> are:0β Set In Progress1β Service Partition Selector2β Service Partition Scan3β BMC Boot Flag Valid Bit Clearing4β Boot Info Acknowledge5β Boot Flags6β Boot Initiator Info7β Boot Initiator Mailbox
set <device> [<options=help,...>]β set the boot device parameter used for the next boot. various options may be used to change when the next boot device is cleared. runoptions=helpfor a list of available bootparam set device options.
Currently supported bootparam device settings are:
force_pxeβ force PXE bootforce_diskβ force boot from default hard-driveforce_safeβ force boot from default hard-drive, request Safe Modeforce_diagβ force boot from diagnostic partitionforce_cdromβ force boot from CD/DVDforce_biosβ force boot into BIOS setup
Currently supported bootparam options settings are associated with BMC Boot Valid Bit Clearing, and they are as follows β and any option can be prefixed with "no-" to invert the sense of the operation. sneaky but valid π
PEFβ clear valid bit on reset/power cycle caused by PEFtimeoutβ automatically clear boot flag valid bit if Chassis Control command is not received within 60 secondswatchdogβ clear valid bit on reset/power cycle caused by watchdog timeoutresetβ clear valid bit on push button reset / soft-resetpowerβ clear valid bit on power up via power push button or wake event
π nm π
alertβ the Node Manager alert vibes π¨clear dest <dest>β clear the Node Manager Alert lan destination.getβ get the Node Manager Alert settings.set chan <chan> dest <dest> string <string>β set the Node Manager alert channel, lan destination, and alert string number.
capabilityβ obtains the Node Manager power control capabilities and ranges. πcontrolβ the on/off switch era ποΈenable|disableβ pick your fighterglobalβ enable/disable all policies for all domains. go big or go home π
okay so we're still deep in Node Manager territory, and the enable|disable side of the group chat has exactly two moves. no cap, here they are:
per_domain <platform|CPU|Memory>β turns all the policies on or off for whichever domain you name.platform,CPU, orMemory, pick your fighter πper_policy <0-7>β turns the policy on or off for one specific domain/policy combo. the number is 0-7, bestie, don't freestyle it.
π¦ discover
This one discovers Node Manager presence and spills the Node Manager version, revision, and patch number. presence check plus version tea β¨
π policy
addβ okay so this has two flavors, and both can add a new policy or overwrite an existing one:power <watts> policy_id <0-7> [correction auto|soft|hard] trig_lim <seconds> stats <seconds> [domain <platform|CPU|Memory>] enable|disableβ adds a power policy.correctioncontrols how aggressive the frequency limiting is, and the default isauto.trig_limis the correction time limit and has to be at least6000and not greater than65535.statsis the averaging period in seconds, ranges from1-65535. nodomain? it defaults toplatform. power policy slay π₯inlet <temp> policy_id <0-7> [correction auto|soft|hard] trig_lim <seconds> stats <seconds> [domain <platform|CPU|Memory>] enable|disableβ adds an inlet temp policy. samecorrectiondefaultauto, sametrig_limrange6000to65535, samestatsrange1-65535, samedomaindefaultplatform. temperature policy, but make it cute π‘οΈ
get policy_id <0-7>β grabs a policy that's already stored. retrieval eralimitingβ reports the policy number if any policy is currently limiting power. snitch on the limiting policy πremove policy_id <0-7> [domain <platform|CPU|Memory>]β deletes a policy. nodomain? defaults toplatform.
β‘ power
power min <minimum> max <maximum> [domain <platform|CPU|Memory>]β configures Node Manager power minimum and maximum power draw limits.minandmaxmust be in the range0-65535. nodomain? defaults toplatform. set the floor and the ceiling ποΈ
π reset
comm policy_id <0-7> [domain <platform|CPU|Memory>]β resets Node Manager communication statistics. nodomain? defaults toplatform.globalβ resets Node Manager global statistics. big reset energymemory policy_id <0-7> [domain <platform|CPU|Memory>]β resets Node Manager memory throttling statistics. nodomain? defaults toplatform.per_policy policy_id <0-7> [domain <platform|CPU|Memory>]β resets Node Manager per policy statistics. nodomain? defaults toplatform.requests policy_id <0-7> [domain <platform|CPU|Memory>]β resets Node Manager unhandled requests statistics. nodomain? defaults toplatform.response policy_id <0-7> [domain <platform|CPU|Memory>]β resets Node Manager response time statistics. nodomain? defaults toplatform.throttling policy_id <0-7> [domain <platform|CPU|Memory>]β resets Node Manager throttling statistics. nodomain? defaults toplatform.
π statistics
comm_failβ reports Node Manager communication failure statistics. the "oops" report πcpu_throttlingβ reports Node Manager cpu throttling statistics.mem_throttlingβ reports Node Manager memory throttling statistics.policy_power policy_id <0-7> [domain <platform|CPU|Memory>]β reports Node Manager per policy power statistics (policy must be a power limit type policy). nodomain? defaults toplatform.policy_temps policy_id <0-7> [domain <platform|CPU|Memory>]β reports Node Manager per policy temp statistics (policy must be an inlet temp limit policy). nodomain? defaults toplatform.policy_throt policy_id <0-7> [domain <platform|CPU|Memory>]β reports Node Manager per policy throttling statistics. nodomain? defaults toplatform.requestsβ reports Node Manager unhandled requests statistics.responseβ reports Node Manager response time statistics.
π§ suspend
get policy_id <0-7> [domain <platform|CPU|Memory>]β gets Node Manager policy suspend periods. nodomain? defaults toplatform.set policy_id <0-7> [domain <platform|CPU|Memory>] <start> <stop> <repeat>β sets Node Manager policy suspend periods. nodomain? defaults toplatform.<start>and<stop>have to be in the range0-239, which is the number of minutes past midnight divided by6.<repeat>is the daily recurrence pattern: bit0is repeat every Monday, bit1is repeat every Tuesday, on through bit6for Sunday. calendar girl math ποΈ
π threshold
get policy_id <0-7> [domain <platform|CPU|Memory>]β gets Node Manager policy Alert Threshold settings. nodomain? defaults toplatform.set policy_id <0-7> [domain <platform|CPU|Memory>] thresh_arrayβ sets Node Manager policy Alert Threshold values. nodomain? defaults toplatform. thethresh_arrayis1,2, or3integers that set three alert threshold settings. the setting type is a power or temperature value, and it must match the type of policy. matching energy only π
πΈ pef
infoβ queries the BMC and prints information about the PEF supported features.statusβ prints the current PEF status (the last SEL entry processed by the BMC, etc). status checkpolicyβ lists the PEF policy table entries. each policy entry describes an alert destination. a policy set is a collection of table entries. PEF alert actions reference policy sets.listβ lists the PEF table entries. each PEF entry relates a sensor event to an action. when PEF is active, each platform event causes the BMC to scan this table for entries matching the event, and possible actions to be taken. actions are performed in priority order (higher criticality first). priority order, periodt π₯
π§ picmg <properties>
runs a PICMG/ATA extended command. Get PICMG properties may be used to obtain and print Extension major version information, PICMG identifier, FRU Device ID and Max FRU Device ID. PICMG lore unlocked π§
addrinfoβ gets address information. this command may return information on the Hardware address, IPMB-0 Address, FRU ID, Site/Entity ID, and Site/Entity Type. address revealfrucontrol <fru id> <options>β sets various control options:0x00β Cold Reset0x01β Warm Reset0x02β Graceful Reboot0x03β Issue Diagnostic Interrupt0x04β Quiesce [AMC only]0x05-0xFFβ Cold Reset
activate <fru id>β activates the specified FRU. wake it up β¨deactivate <fru id>β deactivates the specified FRU.policy get <fru id>β gets FRU activation policy.policy set <fru id> <lockmask> <lock>β sets FRU activation policy.lockmaskis1or0to indicate action on the deactivation or activation locked bit respectively.lockis1or0to set/clear locked bit.portstate set|getall|getgranted|getdenied <parameters>β gets or sets various port states. see usage for parameter details. parameter details live in usage, bestie
β‘ power <chassis power command>
shortcut to the chassis power commands. see the chassis power commands for usage information. shortcut szn
πͺ raw <netfn> <cmd> [<data>]
this lets you execute raw IPMI commands. for example, to query the POH counter with a raw command:
> ipmitool -v raw 0x0 0xf
RAW REQ (netfn=0x0 cmd=0xf data_len=0)
RAW RSP (5 bytes)
3c 72 0c 00 00
note: the OpenIPMI driver provided by the Linux kernel will reject the Get Message, Send Message and Read Event Message Buffer commands because it handles the message sequencing internally. do not fight the driver, bestie π
π sdr
get <id> ... [<id>]β prints information for sensor data records specified by sensor id. sensor tea, served fresh π
info
Okay so this command will query the BMC for Sensor Data Record (SDR) Repository information. slay, now we know what the SDR repo is up to.
type [<sensor type>]β This command will display all records from the SDR Repository of a specific type. Run withtype list(or simply with no type) to see the list of available types. For example to query for all Temperature sensors:
> ipmitool sdr type Temperature
Baseboard Temp | 30h | ok | 7.1 | 28 degrees C
FntPnl Amb Temp | 32h | ok | 12.1 | 24 degrees C
Processor1 Temp | 98h | ok | 3.1 | 57 degrees C
Processor2 Temp | 99h | ok | 3.2 | 53 degrees C
list | elist [<all|full|compact|event|mcloc|fru|generic>]β This command will read the Sensor Data Records (SDR) and extract sensor information of a given type, then query each sensor and print its name, reading, and status. If invoked aselistthen it will also print sensor number, entity id and instance, and asserted discrete states.
The default output will only display full and compact sensor types, to see all sensors use the all type with this command.
Valid types are:
allβ All SDR records (Sensor and Locator)fullβ Full Sensor Recordcompactβ Compact Sensor Recordeventβ Event-Only Sensor Recordmclocβ Management Controller Locator Recordfruβ FRU Locator Recordgenericβ Generic SDR records
entity <id>[.<instance>]β Displays all sensors associated with an entity. Get a list of valid entity ids on the target system by issuing thesdr elistcommand. A list of all entity ids can be found in the IPMI specifications. iykyk β¨dump <file>β Dumps raw SDR data to a file. This data file can then be used as a local SDR cache of the remote managed system with the-S <file>option on theipmitoolcommand line. This can greatly improve performance over system interface or remote LAN. obsessed with a good cache glow-up πfill sensorsβ Create the SDR Repository for the current configuration. Will perform a'Clear SDR Repository'command so be careful.
β οΈ Bestie, for real:fill sensorswill perform a'Clear SDR Repository'command, so be careful.
fill file <filename>β Fill the SDR Repository using records stored in a binary data file. Will perform a'Clear SDR Repository'command so be careful.
β οΈ Same warning energy:fill file <filename>will perform a'Clear SDR Repository'command, so be careful.
sel π§Ύ
β οΈ NOTE: System Event Log (SEL) entry-times are displayed asPre-Init Time-stampif the SEL clock needs to be set. Ensure that the SEL clock is accurate by invoking thesel time getandsel time set <time string>commands.
infoβ This command will query the BMC for information about the System Event Log (SEL) and its contents.clearβ This command will clear the contents of the SEL. It cannot be undone so be careful. no cap, this is the point of no return πlist | elistβ When this command is invoked without arguments, the entire contents of the System Event Log are displayed. If invoked aselist(extended list) it will also use the Sensor Data Record entries to display the sensor ID for the sensor that caused each event. Note this can take a long time over the system interface.<count> | first <count>β Displays the first count (least-recent) entries in the SEL. If count is zero, all entries are displayed.last <count>β Displays the last count (most-recent) entries in the SEL. If count is zero, all entries are displayed.
delete <SEL Record ID> ... <SEL Record ID>β Delete one or more SEL event records. bye bye, little records π¦add <filename ID>β Read event entries from a file and add them to the SEL. New SEL entries are added onto the SEL after the last record in the SEL. Record added is of type 2 and is automatically timestamped.get <SEL Record ID>β Print information on the specified SEL Record entry.save <file>β Save SEL records to a text file that can be fed back into theevent fileipmitoolcommand. This can be useful for testing Event generation by building an appropriate Platform Event Message file based on existing events. Please see the available help for the'event file ...'command for a description of the format of this file.writeraw <file>β Save SEL records to a file in raw, binary format. This file can be fed back to thesel readrawipmitoolcommand for viewing.readraw <file>β Read and display SEL records from a binary file. Such a file can be created using thesel writerawipmitoolcommand.timeβ SEL clock time stuff, because timestamps need to be cute and accurate β°getβ Displays the SEL clock's current time.set <time string>β Sets the SEL clock. Future SEL entries will use the time set by this command.<time string>is of the form"MM/DD/YYYY HH:MM:SS". Note that hours are in 24-hour form. It is recommended that the SEL be cleared before setting the time.
sensor π‘οΈ
listβ Lists sensors and thresholds in a wide table format.get <id> ... [<id>]β Prints information for sensors specified by name.thresh <id> <threshold> <setting>β This allows you to set a particular sensor threshold value. The sensor is specified by name.
Valid thresholds are:
unrβ Upper Non-Recoverableucrβ Upper Criticaluncβ Upper Non-Criticallncβ Lower Non-Criticallcrβ Lower Criticallnrβ Lower Non-Recoverable
thresh <id> lower <lnr> <lcr> <lnc>β This allows you to set all lower thresholds for a sensor at the same time. The sensor is specified by name and the thresholds are listed in order of Lower Non-Recoverable, Lower Critical, and Lower Non-Critical.thresh <id> upper <unc> <ucr> <unr>β This allows you to set all upper thresholds for a sensor at the same time. The sensor is specified by name and the thresholds are listed in order of Upper Non-Critical, Upper Critical, and Upper Non-Recoverable.
session π₯
info <active|all|id 0xnnnnnnnn|handle 0xnn>β Get information about the specified session(s). You may identify sessions by their id, by their handle number, by their active status, or by using the keywordallto specify all sessions.
set βοΈ
hostname <host>β Session hostname.username <user>β Session username.password <pass>β Session password.privlvl <level>β Session privilege level force.authtype <type>β Authentication type force.localaddr <addr>β Local IPMB address.targetaddr <addr>β Remote target IPMB address.port <port>β Remote RMCP port.csv [level]β Enable output in comma separated format. Affects following commands:user,channel,isol,sunoem,sol,sensor,sdr,sel,session. spreadsheet era πverbose [verbose]β Verbosity level.
shell π
This command will launch an interactive shell which you can use to send multiple ipmitool commands to a BMC and see the responses. This can be useful instead of running the full ipmitool command each time. Some commands will make use of a Sensor Data Record cache and you will see marked improvement in speed if these commands are able to reuse the same cache in a shell session. LAN sessions will send a periodic keepalive command to keep the IPMI session from timing out. main character shell energy β¨
sol π
info [<channel number>]β Retrieve information about the Serial-Over-LAN configuration on the specified channel. If no channel is given, it will display SOL configuration data for the currently used channel.payload <enable | disable | status> <channel number> <userid>β Enable, disable or show status of SOL payload for the user on the specified channel.set <parameter> <value> [<channel>]β Configure parameters for Serial Over Lan. If no channel is given, it will display SOL configuration data for the currently used channel. Configuration parameter updates are automatically guarded with the updates to the set-in-progress parameter.
Valid parameters and values are:
set-in-progressβset-complete set-in-progress commit-writeenabledβtrue falseforce-encryptionβtrue falseforce-authenticationβtrue falseprivilege-levelβuser operator admin oemcharacter-accumulate-levelβ Decimal number given in 5 milliseconds incrementscharacter-send-thresholdβ Decimal numberretry-countβ Decimal number.0indicates no retries after packet is transmitted.
retry-intervalβ a decimal number, counted in 10 millisecond increments. Set it to0and the retries get fired back to back with zero breathing room. π¨non-volatile-bit-rateβ your options areserial,19.2,38.4,57.6,115.2. If you set it toserial, that means the BMC should use the setting used by the IPMI over serial channel. iykyk β¨volatile-bit-rateβ same menu, bestie:serial,19.2,38.4,57.6,115.2. Set it toserialand the BMC should use the setting used by the IPMI over serial channel. π
activate [usesolkeepalive | nokeepalive] [instance=<number>]
This is the moment ipmitool slides into Serial Over LAN mode, and it's only available when you're using the lanplus interface β no substitutions, okay? π
An RMCP+ connection gets made to the BMC, your terminal gets flipped into raw mode, and everything you type gets yeeted straight to the serial console on the remote server. On exit, the SOL payload mode is deactivated and the terminal is reset to its original settings. Iconic behavior, honestly.
If you hand it an instance, it activates using that instance number. Default is 1.
Special escape sequences exist to control the SOL session, and they are:
~.β terminate the connection~^Zβ suspend ipmitool~^Xβ suspend ipmitool, but don't restore the tty on restart~Bβ send break~~β send the escape character by typing it twice~?β print the supported escape sequences
Heads up bestie: escapes are only recognized immediately after a newline. So don't be out here mashing tildes mid-line and wondering why nothing happens π
deactivate [instance=<number>]
Deactivates Serial Over LAN mode on the BMC. Normally, exiting Serial Over LAN mode should automatically cause this command to be sent to the BMC β but if you had an unintentional exit from SOL mode, this command may be necessary to reset the state of the BMC. Basically it's the cleanup crew for when things got messy. π§Ή
If you give it an instance, it deactivates that instance number. Default is 1.
π¦ spd
spd <i2cbus> <i2caddr> [<channel>] [<axread>]
This command may be used to read SPD (Serial Presence Detect) data using the I2C Master Write-Read IPMI command. Very demure, very mindful, very low-level. β¨
π sunoem
Okay so sunoem has a whole little friend group of subcommands, let's meet them π
cli [<command string> ...]
Execute the service processor command line interface commands. With no command string at all, you get dropped into an interactive session inside the service processor command line environment β main character energy, you're literally inside the SP now. If you do specify a command string, that command string is executed on the service processor and the connection is closed. In and out. πͺ
led
These commands provide a way to get and set the status of LEDs on a Sun Microsystems server. Use sdr list generic to get a list of devices that are controllable LEDs. The ledtype parameter is optional and not necessary to provide on the command line unless it is required by hardware.
get <sensorid> [<ledtype>]β Get status of a particular LED described by a Generic Device Locator record in the SDR. Asensoridofallwill get the status of all available LEDS. πset <sensorid> <ledmode> [<ledtype>]β Set status of a particular LED described by a Generic Device Locator record in the SDR. Asensoridofallwill set the status of all available LEDS to the specifiedledmodeandledtype. π
LED Mode is required for set operations:
OFFβ OffONβ Steady OnSTANDBYβ 100ms on 2900ms off blink rateSLOWβ 1HZ blink rateFASTβ 4HZ blink rate
LED Type is optional:
OK2RMβ Ok to RemoveSERVICEβ Service RequiredACTβ ActivityLOCATEβ Locate
nacname <ipmi name>
Return the full NAC name of a target identified by ipmi name. Short and sweet. π
ping <count> [<q>]
Send and receive count packets. Each packet is 64 bytes.
q β Quiet. Displays output only at the start and end of the process. So you don't get spammed with packets, slay. π
getval <property name>
Returns value of specified ILOM property. That's it, that's the whole thing. π
setval <property name> <property value> [<timeout>]
Sets value of ILOM property. If timeout is not specified, the default value is 5 seconds.
β οΈ NOTE: setval must be executed locally on host! Not remotely, not over the network, locally. Don't come crying to me when it doesn't work from your jump box π
sshkey
set <userid> <keyfile>β This command will allow you to specify an SSH key to use for a particular user on the Service Processor. This key will be used for CLI logins to the SP and not for IPMI sessions. View available users and their userids with theuser listcommand. πdel <userid>β This command will delete the SSH key for a specifieduserid. Bye bye key π
version
Display the version of ILOM firmware. Quick vibe check on the firmware. β
getfile <file identifier> <destination file name>
This command will return various files from service processor and store them in specified destination file. Note that some files may not be present or be supported by your SP. π
File identifiers:
SSH_PUBKEYS
DIAG_PASSED
DIAG_FAILED
DIAG_END_TIME
DIAG_INVENTORY
DIAG_TEST_LOG
DIAG_START_TIME
DIAG_UEFI_LOG
DIAG_TEST_LOG
DIAG_LAST_LOG
DIAG_LAST_CMD
(Yes, DIAG_TEST_LOG is listed twice in the source β not a typo on my end, bestie, don't @ me π
)
getbehavior <feature identifier>
This command will test if various ILOM features are enabled.
Feature identifiers:
SUPPORTS_SIGNED_PACKAGES
REQUIRES_SIGNED_PACKAGES
πΈ tsol
This command allows Serial-over-LAN sessions to be established with Tyan IPMIv1.5 SMDC such as the M3289 or M3290. The default command run with no arguments will establish a default SOL session back to the local IP address. Optional arguments may be supplied in any order β chaotic but valid, we respect it π«Ά
<ipaddr>β Send receiver IP address to SMDC, which it will use to send serial traffic to. By default this detects the local IP address and establishes a two-way session. Format ofipaddrisXX.XX.XX.XX.port=NUMβ Configure UDP port to receive serial traffic on. By default this is6230.ro|rwβ Confiure SOL session as read-only or read-write. Sessions are read-write by default.
π user
The whole user-management situation, let's get into it π
summary
Displays a summary of userid information, including the maximum number of userids, the number of enabled users, and the number of fixed names defined. A little dashboard of who's who. β¨
list
Displays a list of user information for all defined userids. Everyone's invited to the list. π
set
name <userid> <username>β Sets the username associated with the givenuserid. Name them, bestie π·οΈpassword <userid> [<password> [<16|20>]]β Sets the password for the givenuserid. If no password is given, the password is cleared (set to the NULL password).
π¨ Be careful when removing passwords from administrator-level accounts. Like, genuinely be careful. That's a locked-door situation you're opening. π
If specified, 16 or 20 determines the maximum password length.
disable <userid>
Disables access to the BMC by the given userid. Revoked. π«
enable <userid>
Enables access to the BMC by the given userid. Access granted, welcome back π
priv <userid> <privilege level> [<channel number>]
Set user privilege level on the specified channel. If the channel is not specified, the current channel will be used. Give them exactly the power they need, no more, no less. π₯
test <userid> <16|20> [<password>]
Determine whether a password has been stored as 16 or 20 bytes. Detective work, but make it credential-forensics π΅οΈββοΈ
π INTERFACES π
π OPEN INTERFACE π
Okay so the open interface is the one that rides on the OpenIPMI kernel device driver. That driver ships in all modern 2.4 and all 2.6 kernels, and it should already be in recent Linux distro kernels too. There are also IPMI driver kernel patches for various kernel versions hanging out on the OpenIPMI homepage, iykyk.
The modules you need are different for 2.4 vs 2.6 kernels β do not mix and match, bestie. On a 2.4-based kernel, these modules must be loaded for ipmitool to work:
ipmi_msghandlerβ the incoming and outgoing message handler for IPMI interfaces.ipmi_kcs_drvβ an IPMI Keyboard Controller Style (KCS) interface driver for the message handler.ipmi_devintfβ the Linux character device interface for the message handler.
On a 2.6-based kernel, load these instead:
ipmi_msghandlerβ incoming and outgoing message handler for IPMI interfaces.ipmi_siβ an IPMI system interface driver for the message handler. This one supports a bunch of IPMI system interfaces like KCS, BT, SMIC, and even SMBus in 2.6 kernels. iconic tbh.ipmi_devintfβ the Linux character device interface for the message handler.
Once the required modules are loaded, there's a dynamic character device entry that must exist at /dev/ipmi0. On systems using devfs or udev, it'll show up at /dev/ipmi/0 instead. β¨
To create the device node, first figure out what dynamic major number the kernel assigned β peek in /proc/devices and look for the ipmidev entry. Usually, if this is the first dynamic device, the major number is 254, and the minor number for the first system interface is 0, so you'd create the device entry with:
mknod /dev/ipmi0 c 254 0
ipmitool also ships some sample initialization scripts that can do this task for you automatically at start-up, so you don't have to rawdog it manually π«Ά
And to make ipmitool actually use the OpenIPMI device interface, just say so on the command line:
> ipmitool -I open <command>
πΈ BMC INTERFACE πΈ
The bmc interface uses the bmc device driver as provided by Solaris 10 and higher. To force ipmitool to use this interface, specify it on the command line:
> ipmitool -I bmc <command>
These files are associated with the bmc driver β know them, love them:
/platform/i86pc/kernel/drv/bmcβ 32-bit ELF kernel module for the bmc driver./platform/i86pc/kernel/drv/amd64/bmcβ 64-bit ELF kernel module for the bmc driver./dev/bmcβ character device node used to communicate with the bmc driver.
π¦ LIPMI INTERFACE π¦
The lipmi interface uses the Solaris 9 IPMI kernel device driver. Heads up though: it has been superceeded by the bmc interface on Solaris 10. (Yeah, "superceeded" β that's how the page spells it, and I refuse to gaslight the manpage.) You can tell ipmitool to use this interface by specifying it on the command line:
> ipmitool -I lipmi <expression>
π LAN INTERFACE π
The lan interface talks to the BMC over an Ethernet LAN connection using UDP under IPv4. The UDP datagrams are formatted to contain IPMI request/response messages with IPMI session headers and RMCP headers. Very layered, very demure.
IPMI-over-LAN uses version 1 of the Remote Management Control Protocol (RMCP) to support pre-OS and OS-absent management. RMCP is a request-response protocol delivered using UDP datagrams to port 623.
The LAN interface is an authentication multi-session connection β messages delivered to the BMC can (and should) be authenticated with a challenge/response protocol using either straight password/key or the MD5 message-digest algorithm. ipmitool will attempt to connect with administrator privilege level, because that's required to perform chassis power functions. main character privilege level fr fr π
You can tell ipmitool to use the lan interface with the -I lan option:
> ipmitool -I lan -H <hostname> [-U <username>] [-P <password>] <command>
A hostname must be given on the command line to use the lan interface with ipmitool. The password field is optional; if you don't provide a password on the command line, ipmitool will attempt to connect without authentication. If you do specify a password, it'll use MD5 authentication if the BMC supports it, and straight password/key otherwise β unless you override that with a command line option.
π§ LANPLUS INTERFACE π§
Like the lan interface, the lanplus interface communicates with the BMC over an Ethernet LAN connection using UDP under IPv4. The difference is that lanplus uses the RMCP+ protocol as described in the IPMI v2.0 specification. RMCP+ allows for improved authentication and data integrity checks, plus encryption and the ability to carry multiple types of payloads. Generic Serial Over LAN support requires RMCP+, so the ipmitool sol activate command requires the use of the lanplus interface. No shortcuts, bestie π
RMCP+ session establishment uses a symmetric challenge-response protocol called RAKP (Remote Authenticated Key-Exchange Protocol), which allows the negotiation of many options. ipmitool does not yet allow the user to specify the value of every option, defaulting to the most obvious settings marked as required in the v2.0 specification. Authentication and integrity HMACS are produced with SHA1, and encryption is performed with AES-CBC-128. Role-level logins are not yet supported.
β οΈipmitoolmust be linked with the OpenSSL library in order to perform the encryption functions and support thelanplusinterface. If the required packages aren't found, it will not be compiled in and supported. So iflanplusis ghosting you, that's why π
You can tell ipmitool to use the lanplus interface with the -I lanplus option:
> ipmitool -I lanplus -H <hostname> [-U <username>] [-P <password>] <command>
A hostname must be given on the command line in order to use the lan interface with ipmitool. With the exception of the -A and -C options, the rest of the command line options are identical to those available for the lan interface.
The -C option lets you specify the authentication, integrity, and encryption algorithms to use for a lanplus session, based on the cipher suite ID found in the IPMIv2.0 specification in table 22-20. The default cipher suite is 17, which specifies RAKP-HMAC-SHA256 authentication, HMAC-SHA256-128 integrity, and AES-CBC-128 encryption algorightms. (Again β "algorightms" is the original's spelling, we're keeping it, don't come for me π)
β FREE INTERFACE β
The free interface utilizes the FreeIPMI libfreeipmi drivers. You can tell ipmitool to use the FreeIPMI interface with the -I option:
> ipmitool -I free <command>
π IMB INTERFACE π
The imb interface supports the Intel IMB (Intel Inter-module Bus) Interface through the /dev/imb device. You can tell ipmitool to use the IMB interface with the -I option:
> ipmitool -I imb <command>
β¨ EXAMPLES β¨
Example 1: Listing remote sensors
> ipmitool -I lan -H 1.2.3.4 -f passfile sdr list
Baseboard 1.25V | 1.24 Volts | ok
Baseboard 2.5V | 2.49 Volts | ok
Baseboard 3.3V | 3.32 Volts | ok
Example 2: Displaying status of a remote sensor
> ipmitool -I lan -H 1.2.3.4 -f passfile sensor get "Baseboard 1.25V"
Locating sensor record...
Sensor ID : Baseboard 1.25V (0x10)
Sensor Type (Analog) : Voltage
Sensor Reading : 1.245 (+/- 0.039) Volts
Status : ok
Lower Non-Recoverable : na
Lower Critical : 1.078
Lower Non-Critical : 1.107
Upper Non-Critical : 1.382
Upper Critical : 1.431
Upper Non-Recoverable : na
Example 3: Displaying the power status of a remote chassis
> ipmitool -I lan -H 1.2.3.4 -f passfile chassis power status
Chassis Power is on
Example 4: Controlling the power on a remote chassis
> ipmitool -I lan -H 1.2.3.4 -f passfile chassis power on
Chassis Power Control: Up/On
π FILES π
/usr/share/misc/enterprise-numbersβ system IANA PEN registry taken fromhttp://www.iana.org/assignments/enterprise-numbers~/.local/usr/share/misc/enterprise-numbersβ user's override for the system IANA PEN registry; this file, if it exists, is loaded instead of the system registry (see above). Sneaky little override, love that for you π
π AUTHORS π
Originally written by Duncan Laurie <duncan@iceblink.org>.
Numerous contributors over time. (So many. A whole crowd. Respect π«Ά)
π BUGS π
Any bugs found in ipmitool please report via the GitHub issue system at https://github.com/ipmitool/ipmitool/issues. Don't suffer in silence, bestie β file the issue.
π¦ SEE ALSO π¦
- IPMItool Homepage β
http://github.com/ipmitool/ipmitool - Intelligent Platform Management Interface Specification β
http://www.intel.com/design/servers/ipmi - OpenIPMI Homepage β
http://openipmi.sourceforge.net - FreeIPMI Homepage β
http://www.gnu.org/software/freeipmi/
That's the whole page, bestie, you made it to the end π Huge shoutout to Duncan Laurie, who wrote the original, and to the untold contributors over time β this is ipmitool(1), and it ate. Now go power-cycle a chassis responsibly. πβ¨π
π¦ where this page comes from
- alpine 3.24: ipmitool-doc 1.8.19-r1 Β· MIT
- arch rolling: ipmitool 1.8.19-4 Β· BSD
- opensuse-leap 16.0: ipmitool 1.8.19.13.gbe11d94-160000.3.1 Β· BSD-3-Clause
- opensuse-leap 16.0: ipmitool 1.8.19.13.gbe11d94-160000.3.1 Β· BSD-3-Clause
- opensuse-leap 16.0: ipmitool 1.8.19.13.gbe11d94-160000.3.1 Β· BSD-3-Clause
- opensuse-leap 16.0: ipmitool 1.8.19.13.gbe11d94-160000.3.1 Β· BSD-3-Clause
- π girlified by deepseek-ai/DeepSeek-V4.1-Flash-1017 on : a language model's rewrite of the original, under its terms