okay bestie, this is the manual page for powervar_cx_ser from the NUT Manual (that's section 8 of the manual, so it's a driver/admin-type thing, iykyk). Buckle up, we're talking Powervar UPS hardware today β¨
πΈ NAME πΈ
powervar_cx_ser β the driver for Powervar UPM Series UPS equipment that talks over a Serial connection π¦
β¨ SYNOPSIS β¨
powervar_cx_ser -h
powervar_cx_ser -a UPS_NAME [OPTIONS]
π Note, bestie, this matters: this man page only documents the hardware-specific features of the Powervar driver. For all the stuff about the core driver, go read nutupsdrv(8). Periodt.
π SUPPORTED HARDWARE π
This driver supports the Powervar UPM UPS family β specifically the devices with a serial port connection. If your UPM Series device is plugged in over USB instead, no worries, that's a different page: see also powervar_cx_usb(8). π
π EXTRA ARGUMENTS π
These are the optional settings this driver supports, and you drop them into your ups.conf(5) file:
startdelay=num β changes the startup delay time away from its default of 1 second β±οΈoffdelay=num β changes the shutdown delay time away from its default of 0 second πdisptesttime=num β changes the display test time away from the default of 10 seconds β¨
π INSTANT COMMANDS π
This driver supports the following Instant Commands (go check upscmd(8) if you need the deets) π₯
π All GTS and UPM UPS units π
beeper.disableβ turns the UPS beeper off. silence, finally πbeeper.enableβ turns the UPS beeper on.beeper.muteβ mutes the UPS beeper temporarily (it's giving "not forever, just for now").shutdown.returnβ turns off the load, possibly after a delay, and then returns when power is back. main character comeback energy πshutdown.stopβ stops a shutdown that's already in progress.shutdown.rebootβ shuts down the load briefly while the UPS reboots. quick lil nap π΄shutdown.stayoffβ turns off the load and stays off. no comeback arc, sorry π«Άtest.battery.start.deepβ starts a "deep" battery test. this one runs the UPS all the way down to the low battery point and then returns to the AC line β‘test.battery.start.quickβ starts a "quick" battery test. default time is 2 minutes, and you can set that time in theups.conffile. seetestimeabove, bestie πtest.battery.stopβ stops a battery test that's currently in progress. πtest.failure.startβ starts a simulation of an input power failure (fake crisis, dramatic but safe π).test.failure.stopβ stops that simulation of an input power failure.
π¦ All UPM UPS units π¦
test.panel.startβ starts testing the UPS panel.reset.input.minmaxβ resets the minimum and maximum input voltage status. fresh start, we love it β¨
π WRITABLE VARIABLES π
Want to know which variables you can actually write to for this UPS? Go look at upsrw(8), that's the one that tells you. π
π AUTHORS π
- Bill Elliot
<bill@wreassoc.com>
π SEE ALSO π
For USB connected GTS and UPM Series devices, see powervar_cx_usb(8).
The core driver:
Internet resources:
- The NUT (Network UPS Tools) home page:
https://www.networkupstools.org/historic/v2.8.5/
okay that's the whole page, no cap π this was Network UPS Tools 2.8.5, dated 10/07/2026 β go forth and keep those UPSes thriving, bestie ππ¦β¨
π¦ where this page comes from
- fedora 43: nut 2.8.5-9.fc43 Β· GPL-2.0-or-later AND GPL-3.0-or-later
- fedora 43: nut 2.8.5-9.fc43 Β· GPL-2.0-or-later AND GPL-3.0-or-later
- fedora 44: nut 2.8.5-9.fc44 Β· GPL-2.0-or-later AND GPL-3.0-or-later
- fedora 44: nut 2.8.5-9.fc44 Β· GPL-2.0-or-later AND GPL-3.0-or-later
- π girlified by deepseek-ai/DeepSeek-V4.1-Flash on : a language model's rewrite of the original, under its terms