NUT-UPOWER(8)

πŸ“¦
version 2.8.5 Β· 4 versions
, in fedora 43, fedora 44

πŸ’– NUT-UPOWER πŸ’–

okay bestie, so this is the manual page for nut-upower β€” the driver that lets UPower devices talk to NUT over D-Bus. it lives in the NUT Manual, section 8 (system administration commands, iykyk). let's get into it 🫢


✨ NAME ✨

nut-upower β€” the driver for UPower devices, and it does it via D-Bus πŸ’…


🌸 SYNOPSIS 🌸

nut-upower -h

nut-upower -a UPS_NAME [OPTIONS]
πŸ“ heads up: this page only covers the specific stuff that nut-upower does. for the core driver lore, go read nutupsdrv(8).

πŸ¦‹ DESCRIPTION πŸ¦‹

so like, this driver lets you monitor power devices β€” UPSes, batteries, all of it β€” that are being managed by the UPower daemon, and it reaches them through the D-Bus system bus. no cap. πŸ“

what it does is map UPower properties (state, percentage, voltage, etc.) over to standard NUT variables. and that's the whole slay: it means NUT clients can monitor devices that your OS desktop environment natively supports but that other NUT drivers just... don't. not even a little. ✨


πŸ’… EXTRA ARGUMENTS πŸ’…

this driver supports these optional settings in ups.conf(5):

  • port β€” the UPower Object Path of the device you wanna monitor.
    • if you set it to auto (the default), the driver scans for the first UPower device whose object path contains the string "ups_".
    • if you set it to a specific path β€” like, say, /org/freedesktop/UPower/devices/ups_hiddev0 β€” the driver will attempt to monitor that exact device. main character behaviour, honestly.
  • lowbatt β€” the battery percentage threshold below which the LB (Low Battery) status flag gets set. the default value is 20.0. ⚠️ that's a float, bestie, don't come at me with your integer assumptions.

πŸŽ€ INSTALLATION πŸŽ€

to use this driver, add a section to your ups.conf:

[myups]
    driver = nut-upower
    port = auto
    lowbatt = 20
    desc = "Laptop Battery or generic UPS via UPower"

that's it, that's the whole ritual. copy, paste, thrive. πŸ’–


🌈 REQUIREMENTS 🌈

for this to work you need:

  • the upower daemon running and accessible via the D-Bus system bus (non-negotiable, fr fr)
  • GLib 2.0 libraries
  • GIO libraries

no daemon, no vibes. that's just how it is. πŸ’€


πŸ‘‘ AUTHOR πŸ‘‘

Tim Niemueller <tim@niemueller.de>


⭐ SEE ALSO ⭐

ups.conf(5), nutupsdrv(8), upsc(8)

🌐 Internet Resources: 🌐

the NUT (Network UPS Tools) home page: https://www.networkupstools.org/historic/v2.8.5/


and that's the tea, bestie 🫢 this was Network UPS Tools 2.8.5, dated 10/07/2026 β€” go forth and monitor your batteries, you absolute icon πŸ‘‘πŸ’œ