MFIUTIL(8)

πŸ“¦
version 15.1 Β· 2 versions
, in freebsd 15.1

πŸ’– NAME πŸ’–

mfiutil, mrsasutil β€” Utility for managing LSI MegaRAID SAS controllers. Yep bestie, this is the MFIUTIL(8) manual page, and it's giving β€œlet's keep your RAID controller cute and functional” energy. πŸ’…βœ¨


🌈 SYNOPSIS 🌈

mfiutil version
mfiutil [-D device] [-t type] [-u unit] show adapter
mfiutil [-D device] [-t type] [-u unit] show battery
mfiutil [-d] [-e] [-D device] [-t type] [-u unit] show config
mfiutil [-D device] [-t type] [-u unit] show drives
mfiutil [-D device] [-t type] [-u unit] show events [-c class]
        [-l locale] [-n count] [-v] [start [stop]]
mfiutil [-D device] [-t type] [-u unit] show firmware
mfiutil [-D device] [-t type] [-u unit] show foreign [volume]
mfiutil [-D device] [-t type] [-u unit] show logstate
mfiutil [-d] [-e] [-D device] [-t type] [-u unit] show patrol
mfiutil [-d] [-e] [-D device] [-t type] [-u unit] show progress
mfiutil [-D device] [-t type] [-u unit] show volumes
mfiutil [-D device] [-t type] [-u unit] fail drive
mfiutil [-D device] [-t type] [-u unit] good drive
mfiutil [-D device] [-t type] [-u unit] rebuild drive
mfiutil [-D device] [-t type] [-u unit] syspd drive
mfiutil [-D device] [-t type] [-u unit] drive progress drive
mfiutil [-D device] [-t type] [-u unit] drive clear drive {start | stop}
mfiutil [-D device] [-t type] [-u unit] start rebuild drive
mfiutil [-D device] [-t type] [-u unit] abort rebuild drive
mfiutil [-D device] [-t type] [-u unit] locate drive {on | off}
mfiutil [-D device] [-t type] [-u unit] cache volume [setting [value]
        [...]]
mfiutil [-D device] [-t type] [-u unit] name volume name
mfiutil [-D device] [-t type] [-u unit] volume progress volume
mfiutil [-D device] [-t type] [-u unit] clear
mfiutil [-D device] [-t type] [-u unit] create type [-v]
        [-s stripe_size] drive[,drive[,...]] [drive[,drive[,...]]]
mfiutil [-D device] [-t type] [-u unit] delete volume
mfiutil [-D device] [-t type] [-u unit] add drive [volume]
mfiutil [-D device] [-t type] [-u unit] remove drive
mfiutil [-D device] [-t type] [-u unit] start patrol
mfiutil [-D device] [-t type] [-u unit] stop patrol
mfiutil [-D device] [-t type] [-u unit] patrol command [interval
        [start]]
mfiutil [-D device] [-t type] [-u unit] foreign scan
mfiutil [-D device] [-t type] [-u unit] foreign clear [config]
mfiutil [-D device] [-t type] [-u unit] foreign diag [config]
mfiutil [-D device] [-t type] [-u unit] foreign preview [config]
mfiutil [-D device] [-t type] [-u unit] foreign import [config]
mfiutil [-D device] [-t type] [-u unit] flash file
mfiutil [-D device] [-t type] [-u unit] start learn
mfiutil [-D device] [-t type] [-u unit] bbu setting value
mfiutil [-D device] [-t type] [-u unit] ctrlprop rebuild [rate]
mfiutil [-D device] [-t type] [-u unit] ctrlprop alarm [0/1]

πŸ’… DESCRIPTION πŸ’…

Okay so the mfiutil utility is your little tool for displaying or modifying various parameters on LSI MegaRAID SAS RAID controllers. Each invocation of mfiutil is literally zero or more global options followed by a command. And commands may support additional optional or required arguments after the command. Slay. πŸŽ€

Right now, three global options are supported:

  • -D device β€” device specifies the device node of the controller to use. /dev/ will be added to the device node if needed. If no device node is specified, then device will be made of the type and device. 🫢
  • -t type β€” type specifies the type of the controller to work with, either mfi(4) or mrsas(4). If no type is specified, then the name of the invoked tool is used to derive the type.
  • -u unit β€” unit specifies the unit of the controller to work with. If no unit is specified, then unit 0 is used. ✨

Various commands accept either or both of the two options:

  • -d β€” Print numeric device IDs as drive identifier. This is the default. Useful in combination with -e to print both, numeric device IDs and enclosure:slot information. πŸ’–
  • -e β€” Print drive identifiers in enclosure:slot form. See the next paragraph on format details in context of input rather than output.

Drives may be specified in two forms. First, a drive may be identified by its device ID. The device ID for configured drives can be found in show config. Second, a drive may be identified by its location as [Exx:]Syy where xx is the enclosure and yy is the slot for each drive as displayed in show drives. 🌸

Volumes may be specified in two forms. First, a volume may be identified by its target ID. Second, the volume may be specified by the corresponding mfidX device, such as mfid0. πŸ¦‹

The mfiutil utility supports several different groups of commands. The first group of commands provide information about the controller, the volumes it manages, and the drives it controls. The second group of commands are used to manage the physical drives attached to the controller. The third group of commands are used to manage the logical volumes managed by the controller. The fourth group of commands are used to manage the drive configuration for the controller. The fifth group of commands are used to manage controller-wide operations. πŸ’€βœ¨

🌟 Informational commands 🌟

The informational commands include:

  • version β€” Displays the version of mfiutil.
  • show adapter β€” Displays information about the RAID controller such as the model number.
  • show battery β€” Displays information about the battery from the battery backup unit.
  • show config β€” Displays the volume and drive configuration for the controller. Each array is listed along with the physical drives the array is built from. Each volume is listed along with the arrays that the volume spans. If any hot spare drives are configured, then they are listed as well.
  • show drives β€” Lists all of the physical drives attached to the controller.
  • show events [-c class] [-l locale] [-n count] [-v] [start [stop]] β€” Display entries from the controller's event log. The controller maintains a circular buffer of events. Each event is tagged with a class and locale.

The class parameter limits the output to entries at the specified class or higher. The default class is warn. The available classes from lowest priority to highest are:

  • debug β€” Debug messages.
  • progress β€” Periodic progress updates for long-running operations such as background initializations, array rebuilds, or patrol reads.
  • info β€” Informational messages such as drive insertions and volume creations.
  • warn β€” Indicates that some component may be close to failing.
  • crit β€” A component has failed, but no data is lost. For example, a volume becoming degraded due to a drive failure.
  • fatal β€” A component has failed resulting in data loss.
  • dead β€” The controller itself has died. 😭

The locale parameter limits the output to entries for the specified part of the controller. The default locale is all. The available locales are volume, drive, enclosure, battery, sas, controller, config, cluster, and all.

The count parameter is a debugging aid that specifies the number of events to fetch from the controller for each low-level request. The default is 15 events.

By default, matching event log entries from the previous shutdown up to the present are displayed. This range can be adjusted via the start and stop parameters. Each of these parameters can either be specified as a log entry number or as one of the following aliases:

  • newest β€” The newest entry in the event log.
  • oldest β€” The oldest entry in the event log.
  • clear β€” The first entry since the event log was cleared.
  • shutdown β€” The entry in the event log corresponding to the last time the controller was cleanly shut down.
  • boot β€” The entry in the event log corresponding to the most recent boot.
  • show firmware β€” Lists all of the firmware images present on the controller.
  • show foreign β€” Displays detected foreign configurations on disks for importation or removal.
  • show logstate β€” Display the various sequence numbers associated with the event log.
  • show patrol β€” Display the status of the controller's patrol read operation.
  • show progress β€” Report the current progress and estimated completion time for active operations on all volumes and drives.
  • show volumes β€” Lists all of the logical volumes managed by the controller. πŸ‘‘

πŸ› οΈ Physical drive management commands πŸ› οΈ

The physical drive management commands include:

  • fail drive β€” Mark drive as failed. drive must be an online drive that is part of an array.
  • good drive β€” Mark drive as an unconfigured good drive. drive must not be part of an existing array.
  • rebuild drive β€” Mark a failed drive that is still part of an array as a good drive suitable for a rebuild. The firmware should kick off an array rebuild on its own if a failed drive is marked as a rebuild drive.
  • syspd drive β€” Present the drive to the host operating system as a disk SYSPD block device in the format /dev/mfisyspdX. Clear this flag with good drive.
  • drive progress drive β€” Report the current progress and estimated completion time of drive operations such as rebuilds or patrol reads.
  • drive clear drive {start | stop} β€” Start or stop the writing of all 0x00 characters to a drive.
  • start rebuild drive β€” Manually start a rebuild on drive.
  • abort rebuild drive β€” Abort an in-progress rebuild operation on drive. It can be resumed with the start rebuild command.
  • locate drive {on | off} β€” Change the state of the external LED associated with drive. πŸ”₯

πŸŽ€ Logical volume management commands πŸŽ€

The logical volume management commands include:

  • cache volume [setting [value] [...]] β€” If no setting arguments are supplied, then the current cache policy for volume is displayed; otherwise, the cache policy for volume is modified. One or more setting arguments may be given. Some settings take an additional value argument as noted below. The valid settings are:
    • enable β€” Enable caching for both read and write I/O operations.
    • disable β€” Disable caching for both read and write I/O operations.
    • reads β€” Enable caching only for read I/O operations.
  • writes β€” enables caching for write I/O operations only. write girl summer πŸ’…
  • write-back β€” use the write-back policy for cached writes.
  • write-through β€” use the write-through policy for cached writes.
  • read-ahead value β€” sets the read ahead policy for cached reads. The value can be none, adaptive, or always. pick your fighter ✨
  • bad-bbu-write-cache value β€” controls what happens to I/O write caching when the battery is dead or missing 😭. The value can be disable or enable. fr fr leave this disabled unless you have a reason, because otherwise you can lose data when the system loses power.
  • write-cache value β€” controls the write caches on the physical drives backing the volume. The value can be disable, enable, or default.
In general this should stay disabled to avoid data loss when the physical drives lose power. The battery backup of the RAID controller does not save data sitting in the write caches of the physical drives β€” it's giving false security, bestie, don't fall for it πŸ’€

πŸŽ€ name β€” the glow-up

  • name volume name β€” sets the name of volume to name. iconic, she has a name now.
  • volume progress volume β€” reports the current progress and the estimated completion time of volume operations, like consistency checks and initializations. it's giving "are we there yet" πŸ•

🌸 CONFIGURATION COMMANDS 🌸

the ones that actually change stuff. main character energy only πŸ‘‘

the whole wipe

  • clear β€” deletes the entire configuration: all volumes, all arrays, and all spares. everything. gone. no cap 😭🫢

create β€” build a baddie

create type [-v] [-s stripe_size] drive[,drive[,...]] [drive[,drive[,...]]]

creates a new volume. The type says what kind of volume to build. Currently supported types include:

  • jbod β€” creates a RAID0 volume for each drive specified. Every drive has to be its own separate argument.
  • raid0 β€” creates one RAID0 volume spanning the drives listed in the single drive list.
  • raid1 β€” creates one RAID1 volume spanning the drives listed in the single drive list.
  • raid5 β€” creates one RAID5 volume spanning the drives listed in the single drive list.
  • raid6 β€” creates one RAID6 volume spanning the drives listed in the single drive list.
  • raid10 β€” creates one RAID10 volume spanning multiple RAID1 arrays. The drives for each RAID1 array are given as a single drive list.
  • raid50 β€” creates one RAID50 volume spanning multiple RAID5 arrays. The drives for each RAID5 array are given as a single drive list.
  • raid60 β€” creates one RAID60 volume spanning multiple RAID6 arrays. The drives for each RAID6 array are given as a single drive list.
  • concat β€” creates a single volume by concatenating all of the drives in the single drive list. lowkey the chill option.
Note: not all volume types are supported by all controllers. check before you commit, bestie 🧚

If the -v flag is given after type, more verbose output gets enabled. Currently this just gives you notifications as drives are added to arrays and arrays are added to volumes while the configuration is being built. she's chatty and we love her πŸ’–

The -s stripe_size parameter lets you set the stripe size of the array. By default a stripe size of 64K is used. Valid values are 512 through 1M, though the MFI firmware may reject some values β€” so don't come for me if it says no πŸ™ˆ

delete / add / remove

  • delete volume β€” deletes the volume volume. bye bestie πŸ‘‹
  • add drive [volume] β€” marks drive as a hot spare. Drive must be in the unconfigured good state. If volume is given, the hot spare gets dedicated to the arrays backing that volume. Otherwise, drive becomes a global hot spare backing all arrays for this controller. Heads up: drive must be at least as large as the smallest drive in all the arrays it's going to back. no short kings allowed πŸ’…
  • remove drive β€” takes the hot spare drive out of service. It goes back to the unconfigured good state.

πŸ‘‘ CONTROLLER MANAGEMENT COMMANDS πŸ‘‘

patrol reads

patrol command [interval [start]]

sets the patrol read operation mode. The command argument can be one of:

  • disable β€” disables patrol reads.
  • auto β€” enables periodic patrol reads initiated by the firmware. The optional interval argument specifies the interval in seconds between patrol reads. If patrol reads should run continuously, interval is the word continuously. The optional start argument gives a non-negative, relative start time for the next patrol read. If interval or start isn't given, the existing setting gets used.
  • manual β€” enables manual patrol reads that only the user initiates. you're the captain now ⭐
  • start patrol β€” starts a patrol read operation. go go go πŸ”₯
  • stop patrol β€” stops a patrol read that's currently running. sit down πŸͺ‘

foreign configs πŸ›Έ

  • foreign scan β€” scans for foreign configurations and displays the number found.

The config argument for the commands below takes the form of a number from 0 to the total configurations found.

  • foreign clear [config] β€” clears the specified foreign config, or all of them if no config argument is given.
  • foreign diag [config] β€” displays a diagnostic display of the specified foreign config, or all of them if no config argument is given.
  • foreign preview [config] β€” previews the specified foreign config after import, or all of them if no config argument is given.
  • foreign import [config] β€” imports the specified foreign config, or all of them if no config argument is given.

firmware + battery stuff

  • flash file β€” updates the flash on the controller with the firmware stored in file. A reboot is required for the new firmware to take effect. don't skip the reboot, I'm begging 🫢
  • start learn β€” starts a battery relearn.
Note that this seems to always result in the battery being completely drained, regardless of the BBU mode 😭. In particular, the controller write cache will be disabled during the relearn even if transparent learning mode is enabled. so like… plan around it.
  • bbu setting value β€” updates battery backup unit (BBU) properties related to battery relearning. These are the configurable settings:
    • learn-delay β€” adds a delay to the next scheduled battery relearn event. Given in hours, and must lie in the range of 0 to 255.
    • autolearn-mode β€” enables or disables automatic periodic battery relearning. Can be set to enable or disable to respectively enable or disable the relearn cycle. Alternatively you can give a mode of 0, 1, or 2. Mode 0 enables periodic relearning, mode 1 disables it, and mode 2 disables it and logs a warning to the event log when it detects that a battery relearn should be performed. mode 2 is giving "I'm not doing it but I'm telling on myself" πŸ’€
    • bbu-mode β€” sets the BBU's mode of operation. Not supported by all BBUs, so vibe check first. Where it is supported, the possible values are the integers between 1 and 5 inclusive. Modes 1, 2, and 3 enable a transparent learn cycle, whereas modes 4 and 5 do not. The BBU's data retention time is greater when transparent learning isn't used.

ctrlprop

  • ctrlprop rebuild [rate] β€” with no arguments, displays the rate of rebuild (percentage) for volumes. With an integer argument (0-100), sets that value as the new rebuild rate for volumes.
  • ctrlprop alarm [0/1] β€” with no arguments, displays the current alarm enable/disable status. With a 0, disables alarms. With a 1, enables alarms. screaming optional ✨

🌈 EXAMPLES 🌈

configure the cache for volume mfid0 to cache only writes:

mfiutil cache mfid0 writes
mfiutil cache mfid0 write-back

create a RAID5 array spanning the first four disks in the second enclosure:

mfiutil create raid5 e1:s0,e1:s1,e1:s2,e1:s4

configure the first three disks on a controller as JBOD:

mfiutil create jbod 0 1 2

create a RAID10 volume that spans two arrays, each of which contains two disks from two different enclosures:

mfiutil create raid10 e1:s0,e1:s1 e2:s0,e2:s1

add the drive with the device ID of 4 as a global hot spare:

mfiutil add 4

add the drive in slot 2 in the main chassis as a hot spare for volume mfid0:

mfiutil add s2 mfid0

reconfigure a disk as a SYSPD block device with no RAID:

mfiutil syspd 0

configure the adapter to run periodic patrol reads once a week with the first patrol read starting in 5 minutes:

mfiutil patrol auto 604800 300

display the second detected foreign configuration:

mfiutil show foreign 1

set the current rebuild rate for volumes to 40%:

mfiutil ctrlprop rebuild 40

πŸ¦‹ SEE ALSO πŸ¦‹

mfi(4), mrsas(4) β€” go read those too, iykyk 🫢

πŸŽ€ HISTORY πŸŽ€

The mfiutil utility first appeared in FreeBSD 8.0. a legend from day one, periodt πŸ’…


and that's the whole page bestie 🌸 this Debian build of the page is dated September 2, 2011 β€” vintage era, still serving looks πŸ’– go configure something iconic βœ¨πŸŽ€

πŸ“¦ where this page comes from
  • freebsd 15.1: base 15.1