MICROSOL-APC(8)
π MICROSOL-APC π
okay bestie, gather round, because this is microsol-apc, the driver for APC Back-UPS BR UPS equipment, and it lives in section 8 of the NUT Manual. she's niche, she's specific, and she knows exactly what she's about. let's get into it π
β¨ NAME β¨
microsol-apc β the driver that talks to APC Back-UPS BR UPS equipment. yes, that's her whole job and she does it beautifully π
β¨ SYNOPSIS β¨
microsol-apc -a UPS_NAME [OPTIONS]
π real talk: this page only covers the hardware-specific stuff for themicrosol-apcdriver. the core driver lore? that's innutupsdrv(8), go read her too π«Ά
β¨ SUPPORTED HARDWARE β¨
she's picky (as she should be π). here's the UPS models she supports:
- APC Back-UPS BZ1500-BR
- APC Back-UPS BZ2200I-BR
- APC Back-UPS BZ2200BI-BR
now for the lore drop π: back in 2009, Schneider Electric acquired Microsol Technologies, and by 2012 the entire Microsol line was being sold under the APC brand. so this driver is the one holding it down for these newer, APC-branded models. got older equipment? no problem, that's solis(8)'s moment β¨
β¨ EXTRA ARGUMENTS β¨
these are the extra optional settings she takes in ups.conf(5). lowkey important, highkey useful:
battext=nβ Default = 0, no extra battery, where n = Ampere*hour. πprgshut=nβ Default = 0, no programmable shutdown; set it to 1 to enable one.
β¨ COMMANDS β¨
the two things you can ask her to do, and she does them on a schedule:
shutdown.returnβ Shut down in .3 minutes and restart in .3 minutes after that. she leaves, she comes back, it's giving healthy relationship πshutdown.stayoffβ Shut down in .3 minutes and do not return. she's gone, gone. periodt π
β¨ ISSUES β¨
okay so listen, this part matters π
for other APC-Microsol models, the reported voltages, currents and power will be incorrect, because the communication protocol reports unprocessed data instead of real values β it needs model-specific post-processing by the driver to make sense of any of it. monitoring of UPS state (on-battery/on-line, critical battery) should work for other models, but bestie, it is untested. no cap. don't come for her if it's weird π
β¨ AUTHORS β¨
the icons who made this happen πβ¨
- Ygor A. S. Regados
<ygorre@tutanota.com> - Roberto P. Velloso
<rvelloso@gmail.com> - Silvino B. MagalhΓ£es
<sbm2yk@gmail.com>
β¨ SEE ALSO β¨
πΈ The core driver:
πΈ Driver for older devices under same brand:
πΈ Internet resources:
The NUT (Network UPS Tools) home page:
and that's the whole vibe check, bestie π¦ this was Network UPS Tools 2.8.5, dated 10/07/2026 β go forth, monitor your UPS, and slay π π
π¦ where this page comes from
- fedora 43: nut 2.8.5-9.fc43 Β· GPL-2.0-or-later AND GPL-3.0-or-later
- fedora 43: nut 2.8.5-9.fc43 Β· GPL-2.0-or-later AND GPL-3.0-or-later
- fedora 44: nut 2.8.5-9.fc44 Β· GPL-2.0-or-later AND GPL-3.0-or-later
- fedora 44: nut 2.8.5-9.fc44 Β· GPL-2.0-or-later AND GPL-3.0-or-later
- π girlified by deepseek-ai/DeepSeek-V4.1-Flash on : a language model's rewrite of the original, under its terms