OCF_HEARTBEAT_NVMET-NAMESPACE(7)

πŸŽ€ NAME πŸŽ€

okay so this page is ocf_heartbeat_nvmet-namespace β€” the NVMe-oF target export agent, bestie ✨ and it's part of the OCF_HEARTBEAT_NVMET() manual-page fam. periodt.

🌸 SYNOPSIS 🌸

nvmet-namespace [start | stop | status | monitor | meta-data |
                validate-all]

πŸ’– DESCRIPTION πŸ’–

This agent manages NVMe-oF namespaces, no cap. An NVMe-oF namespace is part of an NVMe-oF target, and it must be created after the subsystem. Conceptually it's giving the same energy as the LUN of an iSCSI target πŸ¦‹.

πŸŽ€ SUPPORTED PARAMETERS πŸŽ€

  • nqn β€” The NVMe Qualified Name (NQN) identifies the remote NVMe storage target. It's similar to an iSCSI Qualified Name (IQN). It's technically a free-form string, but bestie, please follow the convention: nqn.2014-08.com.vendor:nvme:nvm-subsystem-sn-12345 ✨ You need to refer here to the NQN of an NVMe Subsystem you created with the NVMeSubsystem resource agent. metadata: (unique, required, string, no default).
  • namespace_id β€” The NVMe namespace id (number). metadata: (unique, optional, integer, default 1).
  • backing_path β€” The full path to the block device or file that should be exposed through this namespace. metadata: (required, string, no default).
  • uuid β€” The UUID that should be exposed by NVMe. Create it using uuidgen. This is necessary for the initiators to accept the namespace from the new server after failover πŸ‘‘. metadata: (unique, required, string, no default).
  • nguid β€” NGUID stands for Namespace Globally Unique Identifier. Seems to be optional; looks like e.g. VMWare ESXi7 uses it to identify namespaces. Use uuidgen to create it. metadata: (unique, optional, string, no default).

πŸ”₯ SUPPORTED ACTIONS πŸ”₯

This resource agent supports the following actions (operations), fr fr:

  • start β€” Starts the resource. Suggested minimum timeout: 10s.
  • stop β€” Stops the resource. Suggested minimum timeout: 10s.
  • status β€” Performs a status check. Suggested minimum timeout: 10s. Suggested interval: 10s.
  • monitor β€” Performs a detailed status check. Suggested minimum timeout: 10s. Suggested interval: 10s.
  • meta-data β€” Retrieves resource agent metadata (internal use only). Suggested minimum timeout: 5s.
  • validate-all β€” Performs a validation of the resource configuration. Suggested minimum timeout: 10s.

🧚 EXAMPLE CRM SHELL 🧚

Here's an example config for a nvmet-namespace resource using the crm(8) shell β€” iconic, honestly:

          primitive p_nvmet-namespace ocf:heartbeat:nvmet-namespace \
            params \
              nqn=string \
              backing_path=string \
              uuid=string \
            op monitor timeout="10s" interval="10s" depth="0"

🌈 EXAMPLE PCS 🌈

And here's an example config for a nvmet-namespace resource using pcs(8) β€” slay πŸ’…:

          pcs resource create p_nvmet-namespace ocf:heartbeat:nvmet-namespace \
            nqn=string \
            backing_path=string \
            uuid=string \
            op monitor timeout="10s" interval="10s" OCF_CHECK_LEVEL="0"

πŸ¦‹ SEE ALSO πŸ¦‹

http://clusterlabs.org/ β€” go look, bestie 🫢

πŸ’œ AUTHOR πŸ’œ

ClusterLabs contributors (see the resource agent source for information about individual authors).


mwah πŸ’‹ β€” and that's the footer vibe, bestie: OCF_HEARTBEAT_NVMET(), ClusterLabs contributors (see the resource agent source for individual authors). No date was printed on this page, so we're not making one up 🫢.