snmpa_ne...interface(3erl)

πŸ“¦
version 25.3.2.8 Β· 4 versions
, in ubuntu noble

πŸ’– NAME πŸ’–

okay bestie, this manual page is snmpa_ne...interface(3erl) β€” an Erlang Module Definition β€” and the module it's describing is snmpa_network_interface. It's the Behaviour module for the SNMP agent network interface. πŸ’…βœ¨


πŸ¦‹ DESCRIPTION πŸ¦‹

okay so, this module defines the behaviour of the agent network interface. A snmpa_network_interface compliant module must export the following functions, no cap:

  • start_link/4
  • info/1
  • get_log_type/1
  • set_log_type/2
  • verbosity/2

the semantics of them and their exact signatures are explained below, bestie. 🫢

and ngl, that is not enough β€” there is also a set of mandatory messages which the network interface entity must be able to receive and be able to send. that whole situation is described in chapter snmp_agent_netif. πŸ‘‘


✨ EXPORTS ✨

start_link(Prio, NoteStore, MasterAgent, Opts) -> {ok, Pid} | {error, Reason}

Types:

Prio = priority()
NoteStore = pid()
MasterAgent = pid()
Opts = [opt()]
opt() = {verbosity, verbosity()} | {versions, versions()} | term()
versions() = [version()]
version() = v1 | v2 | v3

Start-link the network interface process. slay. πŸ’–

NoteStore is the pid of the note-store process and MasterAgent is the pid of the master-agent process. πŸŽ€

Opts is an (basically) implementation dependent list of options to the network interface process. There are however a number of options which must be handled: versions and verbosity. periodt. πŸ‘‘


πŸŽ€ info/1 πŸŽ€

info(Pid) -> [{Key, Value}]

Types:

Pid = pid()

The info returned is basically up to the implementer to decide. This implementation provided by the application provides info about memory allocation and various socket information. iykyk. 🫢

The info returned by this function is returned together with other info collected by the agent when the info function is called (tagged with the key net_if). 🌈


πŸ’œ verbosity/2 πŸ’œ

verbosity(Pid, Verbosity) -> void()

Types:

Pid = pid()
Verbosity = verbosity()

Change the verbosity of a running network interface process. lowkey iconic. ✨


πŸ”₯ get_log_type/1 πŸ”₯

get_log_type(Pid) -> {ok, LogType} | {error, Reason}

Types:

Pid = pid()
LogType = atl_type()
Reason = term()

The Audit Trail Log is managed by the network interface process. So, it is this process that has to retrieve the actual log-type. no cap. πŸ’…


πŸ¦‹ set_log_type/2 πŸ¦‹

set_log_type(Pid, NewType) -> {ok, OldType} | {error, Reason}

Types:

Pid = pid()
NewType = OldType = atl_type()
Reason = term()

The Audit Trail Log is managed by the network interface process. So, it is this process that has to do the actual changing of the type. πŸŽ€

See set_log_type for more info. 🫢


okay that's the whole page, bestie. source/sign-off energy: Ericsson AB, version snmp 5.13.5, page snmpa_ne...interface(3erl). date? the footer does not print one, so we're not inventing it β€” fr fr. stay iconic. πŸ’–βœ¨