β¨ EDS00xx(3) β One-Wire File System β¨
okay bestie, welcome to EDS00xx(3), the page for the One-Wire File System π this is the whole Embedded Data Systems sensor family, and there's a LOT of them, so grab a snack π
π NAME π
EDS β Embedded Data Systems Sensors β¨ and bestie, it's a whole squad:
EDS0064β Temperature π‘οΈEDS0065β Temperature and Humidity π§EDS0066β Temperature and Barometric Pressure π¬οΈEDS0067β Temperature and Light βοΈEDS0068β Temperature, Barometric Pressure and Light πEDS0070β Vibration π³EDS0071β RTD 4-wire temperature π₯EDS0072β RTD 3-wire temperature π₯EDS0080β 8 Channel Analog Current Input β‘EDS0082β 8 Channel Analog Voltage Input β‘EDS0083β 4 Channel Analog Current Input β‘EDS0085β 4 Channel Analog Voltage Input β‘EDS0090β 8 Discrete I/O ποΈ
π SYNOPSIS π
Embedded Data Systems microprocessor-based sensors π«Ά that's the whole synopsis vibe, now the receipts:
Sub-type ( all )
7E [.]XXXXXXXXXXXX[XX][/[ device_id | device_type | tag ]]
Memory ( all )
7E [.]XXXXXXXXXXXX[XX][/[ memory | pages/page.[0-2|ALL] ]]
Standard ( all )
7E [.]XXXXXXXXXXXX[XX][/[ address | crc8 | id | locator | r_address |
r_id | r_locator | type ]]
Temperature ( EDS0064/5/6/7/8 )
7E.XXXXXXXXXXXX/EDS006X [/[ temperature | counters/seconds |
alarm/temp_[hi|low] | alarm/clear | set_alarm/temp_[hi|low] |
threshold/temp_[hi|low] ]]
Humidity ( EDS0065/8 )
7E.XXXXXXXXXXXX/EDS006X [/[ humidity | humidex | dew_point | heat_index
| alarm/humidity_[hi|low] | alarm/humidex_[hi|low] |
alarm/dew_point_[hi|low] | alarm/heat_index_[hi|low] | alarm/clear |
set_alarm/humidity_[hi|low] | set_alarm/humidex_[hi|low] |
set_alarm/dew_point_[hi|low] | set_alarm/heat_index_[hi|low] |
threshold/humidity_[hi|low] |
threshold/humidex_[hi|low] | threshold/dew_point_[hi|low] |
threshold/heat_index_[hi|low] ]]
Barometric Pressure ( EDS0066/8 )
7E.XXXXXXXXXXXX/EDS006X [/[ pressure | inHg | alarm/pressure_[hi|low] |
alarm/inHg_[hi|low] | alarm/clear | set_alarm/pressure_[hi|low] |
set_alarm/inHg_[hi|low] | threshold/pressure_[hi|low] |
threshold/inHg_[hi|low] ]]
Light ( EDS0067/8 )
7E.XXXXXXXXXXXX/EDS006X [/[ light | alarm/light_[hi|low] | alarm/clear |
set_alarm/light_[hi|low] | threshold/light_[hi|low] ]]
Vibration ( EDS0070 )
7E.XXXXXXXXXXXX/EDS0070 [/[ vib_level | vib_peak | vib_min | vib_max |
counter/seconds | alarm/vib_[hi|low] | alarm/clear |
set_alarm/vib_[hi|low] | threshold/vib_[hi|low] ]]
RTD Temperature ( EDS0071/2 )
7E.XXXXXXXXXXXX/EDS007X [/[ temperature | resistance | raw | delay |
user_byte | calibration/[key|constant] | counter/[seconds|samples] |
alarm/temp_[hi|low] | alarm/RTD_[hi_low] | alarm/clear |
set_alarm/temp_[hi|low] | set_alarm/RTD_[hi_low] |
threshold/temp_[hi|low] | threshold/RTD_[hi_low] ]]
Analog Current ( EDS0080 [0-7] EDS0083 [0-3] )
7E.XXXXXXXXXXXX/EDS0080 [/[ current.[0-7|ALL] | max_current.[0-7|ALL] |
min_current.[0-7|ALL] | threshold/current_hi.[0-7|ALL] |
threshold/current_low.[0-7|ALL] | alarm/current_hi.[0-7|ALL|BYTE] |
alarm/current_low.[0-7|ALL|BYTE] | set_alarm/current_hi.[0-7|ALL|BYTE] |
set_alarm/current_low.[0-7|ALL|BYTE] | counter/seconds | memory |
pages/page.[0-4|ALL]
Analog Voltage ( EDS0082 [0-7] EDS0085 [0-3] )
7E.XXXXXXXXXXXX/EDS0082 [/[ volts.[0-7|ALL] | max_volts.[0-7|ALL] |
min_volts.[0-7|ALL] | threshold/volts_hi.[0-7|ALL] |
threshold/volts_low.[0-7|ALL] | alarm/volts_hi.[0-7|ALL|BYTE] |
alarm/volts_low.[0-7|ALL|BYTE] | set_alarm/volts_hi.[0-7|ALL|BYTE] |
set_alarm/volts_low.[0-7|ALL|BYTE] | counter/seconds | memory |
pages/page.[0-4|ALL]
I/O ( EDS0090 )
7E.XXXXXXXXXXXX/EDS009X [/[ input.[0-7|ALL] | counter/[seconds |
pulses.[0-7|ALL]|reset.[0-7|ALL|BYTE]] |
output/[set.[0-7|ALL|BYTE]|off.[0-7|ALL|BYTE]|reset.[0-7|ALL|BYTE]] |
latch/[state.[0-7|ALL|BYTE]|reset.[0-7|ALL|BYTE]] |
alarm/[hi.[0-7|ALL]|low.[0-7|ALL]|clear] |
set_alarm/[hi.[0-7|ALL]|low.[0-7|ALL]]
LED ( all )
7E.XXXXXXXXXXXX/EDS00XX/LED/[state|control]
relay ( all )
7E.XXXXXXXXXXXX/EDS00XX/relay/[state|control]
π FAMILY CODE π
7E β that's the family code, bestie, that's how you know it's one of ours π
π‘οΈ TEMPERATURE π‘οΈ
EDS006X/temperature
read-only, floating-point
Temperature for the EDS006X series of chips π«Ά In the -55C to 125C range, with 0.0636C precision. The temperature is read every second, continually, no days off. Data is presented in the specified temperature scale, Celsius by default β¨
EDS007X/temperature
read-only, floating-point
Temperature for the EDS007X series of chips. Read using a wide-range precise RTD sensor π Typical range is -60C to 260C with 0.15C accuracy, although a range of -200C to 850C is possible. The temperature is read every second unless a longer EDS007X/delay is given. Data is presented in the specified temperature scale, Celsius by default β¨
EDS007X/resistance
read-only, floating-point
Actual measured resistance (Ohms) of the RTD element β‘ Useful if the RTD element doesn't conform to the typical European IEC 60751 standard. iykyk.
π§ HUMIDITY π§
EDS006X/humidity
read-only, floating-point
Relative humidity in the 0-100 range (percent). Read every 0.2 seconds β±οΈ
EDS006X/dew_point
read-only, floating-point
Dew point computed from EDS006X/temperature and EDS006X/humidity, computed every 0.2 seconds. Data is a calculated temperature and is reported in the specified temperature scale. Default Celsius πΈ
EDS006X/heat_index
read-only, floating-point
Heat index computed from EDS006X/temperature and EDS006X/humidity, computed every 0.2 seconds. Data is a calculated temperature and is reported in the specified temperature scale. Default Celsius π₯
EDS006X/humidex
read-only, floating-point
Humidex (popular in Canada π¨π¦) computed from EDS006X/temperature and EDS006X/humidity, computed every 0.2 seconds. Data is a percent and reported in the 0-100 range β¨
βοΈ LIGHT βοΈ
EDS006X/light
read-only, unsigned integer
Ambient light in Lux π Measured every 0.2 seconds β±οΈ
π¬οΈ PRESSURE π¬οΈ
EDS006X/pressure
read-only, floating-point
Ambient pressure, measured every 0.2 seconds. Data in the selected pressure scale (default mBar) π«Ά
EDS006X/inHg
read-only, floating-point
Ambient pressure, measured every 0.2 seconds. Data in the inHg scale π
π³ VIBRATION π³
EDS0070/vib_level
read_only, unsigned integer
Vibration registered by sensor (instantaneous value) in 0-1023 range β‘
EDS0070/vib_peak
read_only, unsigned integer
Vibration registered by sensor (highest recent value -- slowly decays) in 0-1023 range π
EDS0070/vib_min
read_only, unsigned integer
Vibration registered by sensor (lowest value) in 0-1023 range π
EDS0070/vib_max
read_only, unsigned integer
Vibration registered by sensor (highest value) in 0-1023 range π₯
β‘ CURRENT β‘
The EDS0080 and EDS0083 measure current in the 4-20mA range, with upper and threshold limits and the ability to set an alarm and independently trigger a relay if the value is out of range π no cap, that's main character energy.
EDS0080/current.[0-7|ALL] EDS0083/current.[0-3|ALL]
read-only, floating point
Current current level. (4-20mA) yes bestie, "current current" is literally what it says π
EDS0080/max_current.[0-7|ALL] EDS0080/max_current.[0-3|ALL]
EDS0083/min_current.[0-7|ALL] EDS0083/min_current.[0-3|ALL]
read-only, floating point
Maximum and minimum current readings since last alarm/clear command π«Ά
β‘ VOLTAGE β‘
The EDS0082 and EDS0085 measure voltage in the 0-10V range, with upper and threshold limits and the ability to set an alarm and independently trigger a relay if the value is out of range π
EDS0082/volts.[0-7|ALL] EDS0085/volts.[0-3|ALL]
read-only, floating point
Current voltage level. (0-10V) β‘
EDS0082/max_volts.[0-7|ALL] EDS0085/max_volts.[0-3|ALL]
EDS0082/min_volts.[0-7|ALL] EDS0085/min_volts.[0-3|ALL]
read-only, floating point
Maximum and minimum voltage readings since last alarm/clear command β¨
π― THRESHOLD π―
High and low range of acceptable sensor readings. Values outside this range will trigger an alarm if the corresponding EDS00XX/set_alarm flag is set π
EDS00XX/threshold/temp_hi EDS00XX/threshold/temp_low
read-write, floating-point
Threshold temperatures in the specified temperature scale. Default Celsius π‘οΈ
EDS006X/threshold/humidity_hi EDS006X/threshold/humidity_low
EDS006X/threshold/dew_point_hi EDS006X/threshold/dew_point_low
EDS006X/threshold/heat_index_hi EDS006X/threshold/heat_index_low
EDS006X/threshold/humidex_hi tEDS006X/threshold/humidex_low
read-write, floating-point
Threshold humidity values. Dew point and Heat index are in the specified temperature scale. Default Celsius π§
EDS006X/threshold/pressure_hi EDS006X/threshold/pressure_low
EDS006X/threshold/inHg_hi EDS006X/threshold/inHg_low
read-write, floating-point
Threshold barometric pressure values. Pressure is the specified pressure scale. Default mBar π¬οΈ
EDS006X/threshold/light_hi EDS006X/threshold/light_low
read-write, unsigned
Threshold light (lux) values βοΈ
EDS0070/threshold/vib_hi EDS0070/threshold/vib_low
read-write, unsigned
Vibration sensor alarm limits in 0-1023 range π³
EDS007X/threshold/resistance_hi EDS007X/threshold/resistance_low
read-write, floating-point
Threshold RTD resistance values (Ohm) π₯
EDS0080/threshold/current_hi.[0-7|ALL]
EDS0080/threshold/current_low.[0-7|ALL]
EDS0082/threshold/volts_hi.[0-7|ALL] EDS0082/threshold/volts_low.[0-7|ALL]
EDS0083/threshold/current_hi.[0-3|ALL
EDS0083/threshold/current_low.[0-3|ALL]
EDS0085/threshold/volts_hi.[0-3|ALL] EDS0085/threshold/volts_low.[0-3|ALL|]
read-write, floating-point
Voltage or current threshold limits β‘
π¨ SET ALARM π¨
Set conditional alarm to trigger if corresponding flag is set. Also must set high and low threshold, bestie, don't skip that step π«Ά
EDS00XX/set_alarm/temp_hi EDS00XX/set_alarm/temp_low
EDS006X/set_alarm/humidity_hi EDS006X/set_alarm/humidity_low
EDS006X/set_alarm/dew_point_hi EDS006X/set_alarm/dew_point_low
EDS006X/set_alarm/heat_index_hi EDS006X/set_alarm/heat_index_low
EDS006X/set_alarm/humidex_hi EDS006X/set_alarm/humidex_low
EDS006X/set_alarm/pressure_hi EDS006X/set_alarm/pressure_low
EDS006X/set_alarm/inHg_hi EDS006X/set_alarm/inHg_low
EDS006X/set_alarm/light_hi EDS006X/set_alarm/light_low
EDS0070/set_alarm/vib_hi EDS0070/set_alarm/vib_low
EDS007X/set_alarm/resistance_hi EDS007X/set_alarm/resistance_low
EDS0080/set_alarm/current_hi.[0-7|ALL|BYTE]
EDS0080/set_alarm/current_low.[0-7|ALL|BYTE]
EDS0082/set_alarm/volts_hi.[0-7|ALL|BYTE]
EDS0082/set_alarm/volts_low.[0-7|ALL|BYTE]
EDS0083/set_alarm/current_hi.[0-3|ALL|BYTE]
EDS0083/set_alarm/current_low.[0-3|ALL|BYTE]
EDS0085/set_alarm/volts_hi.[0-3|ALL|BYTE]
EDS0085/set_alarm/volts_low.[0-3|ALL|BYTE]
read-write, yes-no
Flag to set corresponding out-of-range alarm. "1" turns on flag, and "0" turns off π
bestie listen, that"1"and"0"thing is the whole on/off deal, so don't be out here typingtrueand wondering why nothing happened π
okay so the out-of-range flags β you can show them or clear them. When a flag is set, the device will respond to a conditional search. And here's the β¨importantβ¨ part, bestie: clearing the flags happens with the EDS00XX/alarm/clear command, NOT just because the measured value wandered back into the center range. The flag stays lit until you actually clear it. periodt.
π¨ EDS00XX/alarm/clear
write-only, yes-no
Write "1" to clear ALL the alarm flags. every single one. one little 1 and they all go bye π
π¨ the individual alarm fields
EDS00XX/alarm/temp_hi EDS00XX/alarm/temp_low
EDS006X/alarm/humidity_hi EDS006X/alarm/humidity_low
EDS006X/alarm/dew_point_hi EDS006X/alarm/dew_point_low
EDS006X/alarm/heat_index_hi EDS006X/alarm/heat_index_low
EDS006X/alarm/humidex_hi EDS006X/alarm/humidex_low
EDS006X/alarm/pressure_hi EDS006X/alarm/pressure_low
EDS006X/alarm/inHg_hi EDS006X/alarm/inHg_low
EDS006X/alarm/light_hi EDS006X/alarm/light_low
EDS0070/alarm/vib_hi EDS007X/alarm/vib_low
EDS007X/alarm/resistance_hi EDS007X/alarm/resistance_low
EDS0080/alarm/current_hi.[0-7|ALL|BYTE]
EDS0080/alarm/current_low.[0-7|ALL|BYTE]
EDS0082/alarm/volts_hi.[0-7|ALL|BYTE]
EDS0082/alarm/volts_low.[0-7|ALL|BYTE]
EDS0083/alarm/current_hi.[0-3|ALL|BYTE]
EDS0083/alarm/current_low.[0-3|ALL|BYTE]
EDS0085/alarm/volts_hi.[0-3|ALL|BYTE]
EDS0085/alarm/volts_low.[0-3|ALL|BYTE]
EDS0090/alarm/hi[0-7|ALL] EDS0090/alarm/low[0-7|ALL]
read-only, yes-no
These show you the corresponding out-of-range alarm. "1" means you're in alarm state (π), and it can only be turned off with clear. that's the whole deal, no shortcuts.
π RELAY π
Optionally found on the EDS006X and EDS007X. It can be controlled by software or by the alarm condition. your choice, bestie.
EDS00XX/relay/control
read-write, unsigned
Set the relay control scheme:
0β alarm control with hysteresis1β alarm control but you needEDS00XX/alarm/clearto unset it2β Control withEDS00XX/relay/state3β Always off
EDS00XX/relay/state
read-write, yes-no
Turn the relay on or off if the EDS00XX/relay/control is set to 2. otherwise this one's just sitting there, lowkey not doing anything.
π LED light π
Found on the EDS006X and EDS007X. Can be controlled by software or the alarm condition. same energy as the relay, honestly.
EDS00XX/LED/control
read-write, unsigned
Set the LED control scheme:
0β alarm control with hysteresis1β alarm control but you needEDS00XX/alarm/clearto unset it2β Control withEDS00XX/LED/state3β Always off
EDS00XX/LED/state
read-write, yes-no
Turn the LED on or off if the EDS00XX/LED/control is set to 2. slay π‘
β COUNTER β
EDS00XX/counter/seconds
read-only, unsigned integer
Approximate seconds since power up. yes, approximate. it's giving "close enough" π
EDS0090/counter/pulses.0-7 | ALL
read-only, unsigned integer
Pulses on each channel since power up or reset. The channel should be set to input ( EDS0090/output/set.x =0 ) for this to make sense.
EDS0090/counter/reset.0-7 | ALL | BYTE
read-write, yes-no
Clear the pulse count on the corresponding channel. fresh start, we love to see it π«Ά
EDS007X/counter/samples
read-only, unsigned integer
Approximate samples since power up.
π¦ MEMORY π¦
memory
read-write, binary
96 bytes of memory. Not all of it is writable, just so you know. Access to EDS00XX functions is better accomplished through the data fields, which expose all the chip features.
pages/page.0 ... pages/page.2 pages/page.ALL
read-write, binary
Memory is split into 3 pages of 32 bytes each. Only page 2 is writable. ALL is an aggregate of the pages. Each page is accessed sequentially.
EDS008X/memory
read-write, binary
160 bytes of memory. Not all is writable. Access to EDS008X functions is better accomplished through the data fields, which expose all the chip features. The EDS008X has more memory than the other chips, so a separate entry in the sudbirectory makes it available.
EDS008X/pages/page.0-4 EDS008X/pages/page.ALL
read-write, binary
Memory is split into 5 pages of 32 bytes each. Only page 5 is writable. The EDS008X has more memory than the other chips, so a separate entry in the sudbirectory makes the extra pages available. ALL is an aggregate of the pages. Each page is accessed sequentially.
π§ SUB-TYPE π§
tag
read-only, ascii
Text description of the device. Up to 30 characters. keep it cute, keep it short π
device_type
read-only, ascii
Device name. E.g: "EDS0071"
device_id
read-only, unsigned
Number corresponding to the hexadecimal type. E.g:
EDS0071 -> 0x0071 -> 113 in decimal
π STANDARD PROPERTIES π
address r_address
read-only, ascii
The entire 64-bit unique ID. Given as upper case hexadecimal digits (0-9A-F).
address starts with the family code.
r_address is the address in reverse order, which is often used in other applications and labeling.
crc8
read-only, ascii
The 8-bit error correction portion. Uses cyclic redundancy check. Computed from the preceding 56 bits of the unique ID number. Given as upper case hexadecimal digits (0-9A-F).
family
read-only, ascii
The 8-bit family code. Unique to each type of device. Given as upper case hexadecimal digits (0-9A-F).
id r_id
read-only, ascii
The 48-bit middle portion of the unique ID number. Does not include the family code or CRC. Given as upper case hexadecimal digits (0-9A-F).
r_id is the id in reverse order, which is often used in other applications and labeling.
locator r_locator
read-only, ascii
Uses an extension of the 1-wire design from iButtonLink company that associated 1-wire physical connections with a unique 1-wire code. If the connection is behind a Link Locator the locator will show a unique 8-byte number (16 character hexadecimal) starting with family code FE. If no Link Locator is between the device and the master, the locator field will be all FF.
r_locator is the locator in reverse order.
present (DEPRECATED)
read-only, yes-no
Is the device currently present on the 1-wire bus?
bestie this one is DEPRECATED β it's giving "we used to use this, now we don't" π«
type
read-only, ascii
Part name assigned by Dallas Semi. E.g. DS2401 Alternative packaging (iButton vs chip) will not be distiguished.
π ALARMS π
None.
(that's it. that's the section. nothing to see here, moving on π)
β¨ DESCRIPTION β¨
1-Wire
1-wire is a wiring protocol and series of devices designed and manufactured by Dallas Semiconductor, Inc. The bus is a low-power low-speed low-connector scheme where the data line can also provide power. (iconic behavior, honestly)
Each device is uniquely and unalterably numbered during manufacture. There are a wide variety of devices, including memory, sensors (humidity, temperature, voltage, contact, current), switches, timers and data loggers. More complex devices (like thermocouple sensors) can be built with these basic devices. There are also 1-wire devices that have encryption included.
The 1-wire scheme uses a single bus master and multiple slaves on the same wire. The bus master initiates all communication. The slaves can be individually discovered and addressed using their unique ID.
Bus masters come in a variety of configurations including serial, parallel, i2c, network or USB adapters.
OWFS design
OWFS is a suite of programs that designed to make the 1-wire bus and its devices easily accessible. The underlying principle is to create a virtual filesystem, with the unique ID being the directory, and the individual properties of the device are represented as simple files that can be read and written.
Details of the individual slave or master design are hidden behind a consistent interface. The goal is to provide an easy set of tools for a software designer to create monitoring or control applications. There are some performance enhancements in the implementation, including data caching, parallel access to bus masters, and aggregation of device communication. Still the fundamental goal has been ease of use, flexibility and correctness rather than speed.
EDS00XX Overview
The EDS00XX sensors are a family of devices from Embedded Data Systems. Although provisional support for several types is included, only early EDS0071 has been tested with OWFS.
The sensors all share the same 7E family code. They have the same first memory page layout with a text tag property that describes them, and a sub-type field giving the particular sensor. The data properties shown in a directory listing will be specific to the sensor sub-type.
EDS0071
The EDS0071 (3) is a micro-processor based 1-wire slave made by EDS (Embedded Data Systams). Is uses a high accuracy and extended range RTD sensor to accurately measure temperatures.
Memory
The EDS00XX sensors are read and controlled by accessing parts of their on-chip memory. Although the raw memory contents are exposed in the memory and pages fields, all the available functionality is best accessed by the other fields. In fact, directly changing memory will confuse OWFS. don't do it π
Relay and LED
All the EDS00XX sensors have an LED and optional relay. Both can be controlled either directly, or when the sensors reaches an alarm state.
πΈ ADDRESSING πΈ
All 1-wire devices are factory assigned a unique 64-bit address. This address is of the form:
- Family Code β 8 bits
- Address β 48 bits
- CRC β 8 bits
Addressing under OWFS is in hexadecimal, of form:
01.123456789ABC
where 01 is an example 8-bit family code, and 12345678ABC is an example 48 bit address.
The dot is optional, and the CRC code can included. If included, it must be correct. (no pressure but it MUST be correct π )
π DATASHEET π
EDS0064EDS0065EDS0066EDS0067EDS0068β https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&srcid=0B_K3iXLLAI7vN2E4NGUwMGItMzc5MS00NDNmLTljZGYtN2NmM2Q3YWE5NmVh&hl=enEDS0070β http://www.embeddeddatasystems.com/assets/images/supportFiles/manuals/EN-UserMan%20%20OW-Vibration%20V01.pdfEDS0071EDS0072β https://docs.google.com/viewer?a=v&pid=explorer&chrome=true&srcid=0B_K3iXLLAI7vMjVhNWQzYzItZTRhMi00NGY2LWI4NTQtYjZlYTgzYzY0NmNm&hl=enEDS0080EDS0083β https://eds.zendesk.com/attachments/token/ulnpj6mvpp6yzwo/?name=EN-USERMAN+OW-IO-AIX-420+v1p0.pdfEDS0082EDS0085β https://eds.zendesk.com/attachments/token/vyai6ylpw6edala/?name=EN-USERMAN+OW-IO-AIX-10V+v1p0.pdfEDS0090β 8 Discrete I/O
β¨ SEE ALSO β¨
okay bestie, this is the part where we hand you the whole friend group π like every single page that vibes with this one, sorted into little cliques so you can go hang out with whichever one you need. no gatekeeping here, we're all connected π«Ά
π₯οΈ Programs
the main-character CLI icons themselves:
owfs(1),owhttpd(1),owftpd(1),owserver(1),owdir(1),owread(1),owwrite(1),owpresent(1),owtap(1)
literally the whole squad, assembled π
βοΈ Configuration and testing
for when you need to set things up or just poke at stuff and see what happens:
owfs(5),owtap(1),owmon(1)
yes owtap shows up twice, it's that kind of friend who's in every group chat π iconic behavior honestly
π Language bindings
so you can talk to your 1-Wire world from whatever language your heart desires:
owtcl(3),owperl(3),owcapi(3)
β° Clocks
timekeeping girlies, rise π:
DS1427(3),DS1904(3),DS1994(3),DS2404(3),DS2404S(3),DS2415(3),DS2417(3)
πͺͺ ID
the "who even are you" department, no cap:
DS2401(3),DS2411(3),DS1990A(3)
π§ Memory
storage besties, the ones who remember everything so you don't have to π¦:
DS1982(3),DS1985(3),DS1986(3),DS1991(3),DS1992(3),DS1993(3),DS1995(3),DS1996(3),DS2430A(3),DS2431(3),DS2433(3),DS2502(3),DS2506(3),DS28E04(3),DS28EC20(3)
π Switches
on, off, and everything in between β¨:
DS2405(3),DS2406(3),DS2408(3),DS2409(3),DS2413(3),DS28EA00(3),InfernoEmbedded(3)
π‘οΈ Temperature
the thermometers, aka the ones we already know and love from this very page π:
DS1822(3),DS1825(3),DS1820(3),DS18B20(3),DS18S20(3),DS1920(3),DS1921(3),DS1821(3),DS28EA00(3),DS28E04(3),EDS0064(3),EDS0065(3),EDS0066(3),EDS0067(3),EDS0068(3),EDS0071(3),EDS0072(3),MAX31826(3)
π§ Humidity
moisture-coded but make it glam:
DS1922(3),DS2438(3),EDS0065(3),EDS0068(3)
β‘ Voltage
one single icon carrying the whole section, we stan a solo act π:
DS2450(3)
ποΈ Resistance
DS2890(3)
𧬠Multifunction (current, voltage, temperature)
the overachievers, doing three things at once with main character energy π₯:
DS2436(3),DS2437(3),DS2438(3),DS2751(3),DS2755(3),DS2756(3),DS2760(3),DS2770(3),DS2780(3),DS2781(3),DS2788(3),DS2784(3)
π’ Counter
DS2423(3)
πΊ LCD Screen
yes bestie, we have screens too:
LCD(3),DS2408(3)
π Crypto
DS1977(3)
π¬οΈ Pressure
DS2406(3),TAI8570(3),EDS0066(3),EDS0068(3)
π Moisture
EEEF(3),DS2438(3)
π¦ AVAILABILITY
where to find the whole thing, bestie:
http://www.owfs.org
go, go, go πββοΈβ¨
π AUTHOR
the legend themselves, the one who built all of this:
Paul Alfille (<paul.alfille@gmail.com>)
periodt. that's the icon. π π
and that's a wrap onEDS00xx(3) π this page is part of the OWFS Manpage, dated 2003, and yeah, the footer really does sayEDS00xx(3) right there at the bottom like a little signature. go read the other pages, go read your sensors, go be great ππ¦β¨
π¦ where this page comes from
- alpine 3.24: owfs-doc 3.2_p4-r1 Β· GPL-2.0-only
- debian bookworm: owfs-doc 3.2p4+dfsg1-4.1 Β· GPL-2.0-only
- debian trixie: owfs-doc 3.2p4+dfsg1-6 Β· GPL-2.0-only
- fedora 43: owfs-devel 3.2p4-13.fc43 Β· GPL-2.0-only
- fedora 43: owfs-devel 3.2p4-13.fc43 Β· GPL-2.0-only
- fedora 43: owfs-libs 3.2p4-13.fc43 Β· GPL-2.0-only
- fedora 43: owfs-libs 3.2p4-13.fc43 Β· GPL-2.0-only
- fedora 44: owfs-devel 3.2p4-15.fc44 Β· GPL-2.0-only
- fedora 44: owfs-devel 3.2p4-15.fc44 Β· GPL-2.0-only
- fedora 44: owfs-libs 3.2p4-15.fc44 Β· GPL-2.0-only
- fedora 44: owfs-libs 3.2p4-15.fc44 Β· GPL-2.0-only
- nixos 26.05: libow 3.2p4
- nixpkgs unstable: libow 3.2p4
- ubuntu jammy: owfs-doc 3.2p4+dfsg1-4build5 Β· GPL-2.0-only
- ubuntu noble: owfs-doc 3.2p4+dfsg1-4.3build2 Β· GPL-2.0-only
- ubuntu questing: owfs-doc 3.2p4+dfsg1-6
- ubuntu resolute: owfs-doc 3.2p4+dfsg1-7 Β· GPL-2.0-only
- ubuntu stonking: owfs-doc 3.2p4+dfsg1-7build1 Β· GPL-2.0-only
- Copyright (c) 2003-2004 Paul H Alfille, MD
- π girlified by deepseek-ai/DeepSeek-V4.1-Flash on : a language model's rewrite of the original, under its terms