MEASURE(1)
โจ MEASURE(1) โจ
okay bestie, welcome to the measure page, living in the User Commands section of the manual ๐ pull up a chair, we're reading spot values together and it's gonna be iconic.
๐ธ NAME ๐ธ
Measure โ Read Print Spot values. that's the whole vibe, that's the assignment ๐
๐ฆ DESCRIPTION ๐ฆ
Measure spot values, Version 1.6.3 โจ
like. it measures spots. it prints the values. it's giving instrument whisperer and honestly? obsessed. no cap, that's genuinely all it does and it does it beautifully ๐ซถ
๐ SYNOPSIS ๐
spotread [-options] [logfile]
๐ OPTIONS ๐
okay so here's the full lineup, every single one, don't skip, I'll know ๐
-vโ verbose mode. it will talk to you about everything it's doing, main character energy fr fr.-sโ print the spectrum for each reading ๐ถ๏ธ-Sโ plot the spectrum for each reading ๐ (yes bestie, we're plotting now)-clistno โ set the communication port from the following list. the default is1. the list, as it stands right now, is literally:** No ports found **
๐ญ not me and the empty port list.
-tโ use transmission measurement mode ๐-eโ use emissive measurement mode (absolute results) ๐ฅ-ebโ use display white brightness relative measurement mode ๐ก-ewโ use display white point relative chromatically adjusted mode ๐จ-pโ use telephoto measurement mode (absolute results) ๐ธ-pbโ use projector white brightness relative measurement mode ๐ฅ-pwโ use projector white point relative chromatically adjusted mode ๐ฌ-aโ use ambient measurement mode (absolute results) ๐ค๏ธ-fโ use ambient flash measurement mode (absolute results) โก-Iillum โ set simulated instrument illumination using FWA (the default is-iillum). the options are:M0,M1,M2,A,C,D50,D50M2,D65,F5,F8,F10orfile.spโจ-iillum โ choose the illuminant for computation of CIE XYZ from spectral data & FWA:A,C,D50(that's the default, bestie),D50M2,D65,F5,F8,F10orfile.sp๐-Qobserv โ choose the CIE Observer for spectral data or CCSS instrument:1931_2(default),1964_10,S&B 1955_2,shaw,J&V 1978_2. (and yeah, you choose FWA during operation ๐)-Ffilter โ set the filter configuration (if applicable):nโ Nonepโ Polarising filter6โ D65uโ U.V. Cut
-Eextrafilterfile โ apply an extra filter compensation file ๐ง-xโ displayYxyinstead ofLab๐-hโ displayLChinstead ofLab๐-Vโ show the running average and standard deviation from the reference ๐-Tโ display correlated color temperatures and CRI ๐ก๏ธ-Nโ disable auto calibration of the instrument. it will not calibrate itself. just so you know ๐-Hโ start in high resolution spectrum mode (if it's available) ๐-Xfile.ccmx โ apply a Colorimeter Correction Matrix ๐งฎ-Xfile.ccss โ use Colorimeter Calibration Spectral Samples for calibration ๐งช-Yr|nโ override refresh, non-refresh display mode ๐-YR:rateโ override the measured refresh rate with rate Hz โฑ๏ธ-YAโ use non-adaptive integration time mode (if available) ๐-Wn|h|xโ override serial port flow control:n= none,h= HW,x= Xon/Xoff ๐-D[level] โ print debug diagnostics tostderr๐- logfile โ optional file to save the reading results as text ๐ (she's organized, we love her)
๐ heads up bestie:-Ndisables auto calibration of the instrument, and-Dsends debug diagnostics tostderr. also the-cport list is currently empty โ** No ports found **โ so no cap, check your ports before you come for her. don't be mad at me, that's just what the page says ๐
and that's the whole page, you ate that ๐
cute little sign-off: this beauty came from spotread, dated September 2014, and it lives under the MEASURE(1) header. go forth and measure, queen ๐๐
๐ฆ where this page comes from
- debian bookworm: argyll 2.3.1+repack-1.1+b1 ยท AGPL-3.0-only
- debian trixie: argyll 3.3.0+repack-1 ยท AGPL-3.0-only
- ubuntu jammy: argyll 2.2.0+repack-1build1 ยท AGPL-3.0-only
- ubuntu noble: argyll 3.1.0+repack-1build4 ยท AGPL-3.0-only
- ubuntu questing: argyll 3.3.0+repack-1
- ubuntu resolute: argyll 3.3.0+repack-1.1 ยท AGPL-3.0-only
- ubuntu stonking: argyll 3.5.0+repack-1build1 ยท AGPL-3.0-only
- ๐ girlified by deepseek-ai/DeepSeek-V4.1-Flash on : a language model's rewrite of the original, under its terms