MEASURE(1)

โœจ MEASURE(1) โœจ

okay bestie, welcome to the measure page, living in the User Commands section of the manual ๐Ÿ’– pull up a chair, we're reading spot values together and it's gonna be iconic.


๐ŸŒธ NAME ๐ŸŒธ

Measure โ€” Read Print Spot values. that's the whole vibe, that's the assignment ๐Ÿ’…


๐Ÿฆ‹ DESCRIPTION ๐Ÿฆ‹

Measure spot values, Version 1.6.3 โœจ

like. it measures spots. it prints the values. it's giving instrument whisperer and honestly? obsessed. no cap, that's genuinely all it does and it does it beautifully ๐Ÿซถ


๐ŸŽ€ SYNOPSIS ๐ŸŽ€

spotread [-options] [logfile]

๐Ÿ‘‘ OPTIONS ๐Ÿ‘‘

okay so here's the full lineup, every single one, don't skip, I'll know ๐Ÿ™ˆ

  • -v โ€” verbose mode. it will talk to you about everything it's doing, main character energy fr fr.
  • -s โ€” print the spectrum for each reading ๐Ÿ•ถ๏ธ
  • -S โ€” plot the spectrum for each reading ๐Ÿ“ˆ (yes bestie, we're plotting now)
  • -c listno โ€” set the communication port from the following list. the default is 1. the list, as it stands right now, is literally:
    • ** No ports found **

๐Ÿ˜ญ not me and the empty port list.

  • -t โ€” use transmission measurement mode ๐ŸŒˆ
  • -e โ€” use emissive measurement mode (absolute results) ๐Ÿ”ฅ
  • -eb โ€” use display white brightness relative measurement mode ๐Ÿ’ก
  • -ew โ€” use display white point relative chromatically adjusted mode ๐ŸŽจ
  • -p โ€” use telephoto measurement mode (absolute results) ๐Ÿ“ธ
  • -pb โ€” use projector white brightness relative measurement mode ๐ŸŽฅ
  • -pw โ€” use projector white point relative chromatically adjusted mode ๐ŸŽฌ
  • -a โ€” use ambient measurement mode (absolute results) ๐ŸŒค๏ธ
  • -f โ€” use ambient flash measurement mode (absolute results) โšก
  • -I illum โ€” set simulated instrument illumination using FWA (the default is -i illum). the options are: M0, M1, M2, A, C, D50, D50M2, D65, F5, F8, F10 or file.sp โœจ
  • -i illum โ€” choose the illuminant for computation of CIE XYZ from spectral data & FWA: A, C, D50 (that's the default, bestie), D50M2, D65, F5, F8, F10 or file.sp ๐Ÿ’œ
  • -Q observ โ€” choose the CIE Observer for spectral data or CCSS instrument: 1931_2 (default), 1964_10, S&B 1955_2, shaw, J&V 1978_2. (and yeah, you choose FWA during operation ๐Ÿ‘€)
  • -F filter โ€” set the filter configuration (if applicable):
    • n โ€” None
    • p โ€” Polarising filter
    • 6 โ€” D65
    • u โ€” U.V. Cut
  • -E extrafilterfile โ€” apply an extra filter compensation file ๐Ÿงš
  • -x โ€” display Yxy instead of Lab ๐Ÿ”„
  • -h โ€” display LCh instead of Lab ๐Ÿ”„
  • -V โ€” show the running average and standard deviation from the reference ๐Ÿ“Š
  • -T โ€” display correlated color temperatures and CRI ๐ŸŒก๏ธ
  • -N โ€” disable auto calibration of the instrument. it will not calibrate itself. just so you know ๐Ÿ‘€
  • -H โ€” start in high resolution spectrum mode (if it's available) ๐Ÿ”
  • -X file.ccmx โ€” apply a Colorimeter Correction Matrix ๐Ÿงฎ
  • -X file.ccss โ€” use Colorimeter Calibration Spectral Samples for calibration ๐Ÿงช
  • -Y r|n โ€” override refresh, non-refresh display mode ๐Ÿ”
  • -Y R:rate โ€” override the measured refresh rate with rate Hz โฑ๏ธ
  • -Y A โ€” use non-adaptive integration time mode (if available) ๐ŸŒ€
  • -W n|h|x โ€” override serial port flow control: n = none, h = HW, x = Xon/Xoff ๐Ÿ”Œ
  • -D [level] โ€” print debug diagnostics to stderr ๐Ÿ›
  • logfile โ€” optional file to save the reading results as text ๐Ÿ“ (she's organized, we love her)
๐Ÿ’€ heads up bestie: -N disables auto calibration of the instrument, and -D sends debug diagnostics to stderr. also the -c port list is currently empty โ€” ** No ports found ** โ€” so no cap, check your ports before you come for her. don't be mad at me, that's just what the page says ๐Ÿ™ˆ

and that's the whole page, you ate that ๐Ÿ’…

cute little sign-off: this beauty came from spotread, dated September 2014, and it lives under the MEASURE(1) header. go forth and measure, queen ๐Ÿ‘‘๐Ÿ’–