NVME-WDC-VS-CLOUD(1)
π NVME-WDC-VS-CLOUD(1) β nvme-wdc-vs-cloud-log, bestie edition β¨
okay so real talk, this is a page from the NVMe Manual and it's about the nvme-wdc-vs-cloud-log command. yes the section name up top is technically nvme-wdc-vs-cloud-log even though the file/manpage is NVME-WDC-VS-CLOUD(1) β that's just how it is, don't @ me π«Ά
β¨ NAME β¨
nvme-wdc-vs-cloud-log β sends the NVMe WDC vs-cloud-log Vendor Unique Command, and gives you the result back. that's the whole gig π
πΈ SYNOPSIS πΈ
nvme [<global-options>] wdc vs-cloud-log <device>
[--namespace-id=<nsid> | -n <nsid>]
π¦ DESCRIPTION π¦
so for the NVMe device you hand it, it sends a Vendor Unique WDC vs-cloud-log command and serves up the smart/health log. that's it, that's the vibe β¨
the <device> parameter is mandatory β no skipping it, bestie, it's literally required π. and it can be either:
- the NVMe character device, like
/dev/nvme0, or - a block device, like
/dev/nvme0n1
β οΈ lowkey important: this only works on WDC devices that support this feature. results for any other device are undefined β like, not "probably fine", actually undefined π so maybe don't.
on success it returns 0, and an error code otherwise. simple as that π
π OPTIONS π
-n <nsid>,--namespace-id=<nsid>β sets the command's nsid value to whatever nsid you give it. if you don't give one, it defaults to0xffffffff. ok and here's the tea: this option may not actually affect anything depending on the log page, because the log page may or may not be specific to a namespace π« . oh and the broadcast value0xffffffffcan also be given asallor-1. cute, right?
π GLOBAL OPTIONS π
these ones live at the top-level nvme command and they're available to this subcommand too. main character energy, honestly π
--dry-runβ prints the command that would be executed, but doesn't actually execute it. all vibes, no action β¨--no-ioctl-probingβ disables probing for 64-bit IOCTL support. just... turns it off, bestie.--no-retriesβ disables the retry logic on transient errors. one shot, no second chances π-o <fmt>,--output-format=<fmt>β sets the reporting format tonormal,tabular,'json, orbinary`. only one output format at a time, pick your fighter π--output-format-version=<version>β selects the output format version. version1uses the original field naming, while version2(the default, iykyk) gives you more consistent and script-friendly field names. other versions? rejected. not invited to the party π ββοΈ--quietβ suppresses informational messages. errors are still reported, and--quietcancels any--verbosefor the library log level. shhh π€«--set-options=<key=value>[,<key=value>...]β sets libnvme library options for this invocation. supported keys areforce-4k,mi-probe-enabled,test-base-dirandtest-sysfs-dir. mix and match, comma-separated, slay π--timeout=<ms>β sets the timeout for the command in milliseconds.infiniteor-1waits without a time limit (0xffffffff). no clock-watching for you β³-v,--verboseβ increases the level of detail in the output. may be specified multiple times to further increase verbosity. more v's = more details, obviously π
and psst β these options can also be set as machine-wide defaults in nvme-cli.conf(5). a command-line flag always overrides the file. flag wins, periodt π
π EXAMPLES π
- has the program issue WDC vs-cloud-log Vendor Unique Command:
# nvme wdc vs-cloud-log /dev/nvme0
literally that easy, go off π§
β NVME β
part of the nvme-user suite. one of us, one of us π«
and that's the whole page, bestie π«Ά it's from the NVMe manual, dated 10/30/2026, and the file itself is NVME-WDC-VS-CLOUD(1) β go forth and check those logs πβ¨
π¦ where this page comes from
- arch rolling: nvme-cli 3.2-1 Β· GPL-2.0-or-later
- π girlified by deepseek-ai/DeepSeek-V4.1-Flash-1017 on : a language model's rewrite of the original, under its terms