NVME-WDC-GET-ERRO(1)
π nvme-wdc-get-error-recovery-log π
okay bestie, welcome to the NVMe Manual β¨ this is the page for the WDC error-recovery-log plugin command, and yes it is a whole vibe.
πΈ NAME πΈ
nvme-wdc-get-error-recovery-log β send the NVMe WDC get-error-recovery-log plugin command and return the parsed log output π«Ά
π¦ SYNOPSIS π¦
nvme [<global-options>] wdc get-error-recovery-log <device>
[--output-format=<normal|json> | -o <normal|json>]
β¨ DESCRIPTION β¨
So for the NVMe device you give it, this sends a WDC plugin get-error-recovery-log command and outputs the error recovery log data. The --output-format option will format the output as specified π
The <device> parameter is mandatory, bestie β it may be either the NVMe character device (ex: /dev/nvme0).
π¨ This will only work on WDC devices supporting this log page. Results for any other device are undefined β like, truly undefined, so don't come for me if you try it on some rando device π
On success it returns the parsed error recovery log page data, error code otherwise. periodt.
π OPTIONS π
π GLOBAL OPTIONS π
The following options are defined at the top-level nvme command and are available to this subcommand:
--dry-runβ Print the command that would be executed, but do not actually execute it.--no-ioctl-probingβ Disable probing for 64-bit IOCTL support.--no-retriesβ Disable retry logic on transient errors.-o <fmt>,--output-format=<fmt>β Set the reporting format tonormal,tabular,'json, orbinary. Only one output format may be used at a time.--output-format-version=<version>β Select the output format version. Version 1 uses the original field naming, while version 2 (default) provides more consistent and script-friendly field names. Other versions are rejected.--quietβ Suppress informational messages. Errors are still reported, and--quietcancels any--verbosefor the library log level.--set-options=<key=value>[,<key=value>...]β Set libnvme library options for this invocation. Supported keys areforce-4k,mi-probe-enabled,test-base-dirandtest-sysfs-dir.--timeout=<ms>β Set the timeout for the command in milliseconds.infiniteor-1waits without a time limit (0xffffffff).-v,--verboseβ Increase the level of detail in the output. May be specified multiple times to further increase verbosity.
These options can also be set as machine-wide defaults in nvme-cli.conf(5). A command-line flag always overrides the file π
π EXAMPLES π
- Has the program issue WDC
get-error-recovery-logplugin command :
# nvme wdc get-error-recovery-log /dev/nvme0
π NVME π
Part of the nvme-user suite. iconic behavior, honestly.
π that's the whole page, bestie β source/version: NVMe Β· date: 10/30/2026 Β· page: NVME-WDC-GET-ERRO(1) Β· byeee β¨
π¦ where this page comes from
- arch rolling: nvme-cli 3.2-1 Β· GPL-2.0-or-later
- π girlified by deepseek-ai/DeepSeek-V4.1-Flash-1017 on : a language model's rewrite of the original, under its terms