NVME-WDC-CLOUD-SS(1)
π nvme-wdc-cloud-SSD-plugin-version β the NVMe manual, but make it cute β¨
okay bestie, welcome to the nvme-wdc-cloud-SSD-plugin-version page from the NVMe Manual π this is the WDC plugin thingy and honestly it's giving "one job, does it well" energy and I respect that so much π«Ά
πΈ NAME πΈ
nvme-wdc-cloud-SSD-plugin-version β shows you the WDC plugin Cloud SSD Plugin Version β¨ like, literally that's the whole gig and she ate π
π¦ SYNOPSIS π¦
nvme [<global-options>] wdc cloud-SSD-plugin-version <device>
that's it. that's the whole vibe. no cap π
β¨ DESCRIPTION β¨
so for the NVMe device you hand over, this command displays the current Cloud SSD Plugin Version β if the device supports it π (if it doesn't, well, we tried bestie, no drama).
the <device> parameter is mandatory, okay? mandatory mandatory. it's an NVMe character device, like /dev/nvme0 for example π
on success it returns 0. any other result is an error code, and that's just how it is π
π OPTIONS π
π GLOBAL OPTIONS π
these bad boys are defined at the top-level nvme command and are available to this subcommand too β they're the main characters, we're just living in their world π
--dry-runβ prints the command that would be executed but doesn't actually execute it π«£ like rehearsing the text instead of sending it. iconic behavior honestly.--no-ioctl-probingβ disables probing for 64-bit IOCTL support β¨ no probing today, we're skipping the vibe check π--no-retriesβ disables retry logic on transient errors π one shot, one opportunity, no second chances bestie.-o <fmt>,--output-format=<fmt>β sets the reporting format tonormal,tabular,json, orbinaryπΈ only one output format at a time, so pick your fighter π--output-format-version=<version>β picks the output format version π₯ version1uses the original field naming, while version2(the default) gives you more consistent and script-friendly field names. any other version? rejected. not invited to the party π--quietβ suppresses informational messages π¦ errors are still reported (of course, we're not hiding problems), and--quietcancels any--verbosefor the library log level. they literally cannot coexist, it's giving exes at the same function π--set-options=<key=value>[,<key=value>...]β sets libnvme library options for this invocation β¨ supported keys areforce-4k,mi-probe-enabled,test-base-dirandtest-sysfs-dir. mix and match, go off π--timeout=<ms>β sets the timeout for the command in milliseconds β±οΈinfiniteor-1waits without a time limit (0xffffffff). no clock, no stress, just vibes π-v,--verboseβ increases the level of detail in the output π₯ and yes you may specify it multiple times to further increase verbosity. stacking buffs, we love to see it π
pro tip (well, actual documented tip, not me making stuff up): these options can also be set as machine-wide defaults in nvme-cli.conf(5) π but a command-line flag always overrides the file. CLI stays winning, periodt π
π EXAMPLES π
- displays the cloud ssd plugin version for the device β¨:
# nvme wdc cloud-SSD-plugin-version /dev/nvme0
see? not scary at all. you got this bestie π
π NVME π
part of the nvme-user suite π«Ά you're officially in the family now.
and that's the whole page, bestie! π¦ this version of the NVME-WDC-CLOUD-SS(1) page (dated 10/30/2026) was brought to you by the NVMe crew β go check the device version, you absolute icon πβ¨
π¦ where this page comes from
- arch rolling: nvme-cli 3.2-1 Β· GPL-2.0-or-later
- π girlified by deepseek-ai/DeepSeek-V4.1-Flash-1017 on : a language model's rewrite of the original, under its terms