NVME-LOG-RESV-NOT(1)

πŸ“¦ version 3.2, in arch rolling

πŸ’… nvme-log-resv-notif β€” NVMe Manual, page NVME-LOG-RESV-NOT(1) πŸ’…

Bestie, you’re in the NVMe Manual, page NVME-LOG-RESV-NOT(1) β€” the reservation-notification-log lore page. Let’s go ✨

🌸 NAME 🌸

nvme-log-resv-notif β€” send an NVMe Reservation Notification log page request, return result and log. Slay. πŸ’–

πŸ¦‹ SYNOPSIS πŸ¦‹

nvme [<global-options>] log resv-notif <device>

✨ DESCRIPTION ✨

Okay so this command retrieves the NVMe Reservation Notification log page from an NVMe device and gives you back the returned structure. Iconic.

The <device> parameter is mandatory, no cap. It may be either the NVMe character device (ex: /dev/nvme0) or a namespace block device (ex: /dev/nvme0n1).

On success, the returned Reservation Notification log structure may be returned in one of several ways depending on the option flags: the structure may be parsed by the program and printed in a readable format, or the raw buffer may be printed to stdout for another program to parse. Choose your fighter 🫢

πŸ’œ OPTIONS πŸ’œ

🌈 GLOBAL OPTIONS 🌈

These options are defined at the top-level nvme command and are available to this subcommand. Periodt.

  • --dry-run β€” Print the command that would be executed, but do not actually execute it.
  • --no-ioctl-probing β€” Disable probing for 64-bit IOCTL support.
  • --no-retries β€” Disable retry logic on transient errors.
  • -o <fmt>, --output-format=<fmt> β€” Set the reporting format to normal, tabular, 'json, or binary. Only one output format may be used at a time.
  • --output-format-version=<version> β€” Select the output format version. Version 1 uses the original field naming, while version 2 (default) provides more consistent and script-friendly field names. Other versions are rejected.
  • --quiet β€” Suppress informational messages. Errors are still reported, and --quiet cancels any --verbose for the library log level.
  • --set-options=<key=value>[,<key=value>...] β€” Set libnvme library options for this invocation. Supported keys are force-4k, mi-probe-enabled, test-base-dir and test-sysfs-dir.
  • --timeout=<ms> β€” Set the timeout for the command in milliseconds. infinite or -1 waits without a time limit (0xffffffff).
  • -v, --verbose β€” Increase the level of detail in the output. May be specified multiple times to further increase verbosity.

These options can also be set as machine-wide defaults in nvme-cli.conf(5). A command-line flag always overrides the file. πŸ’…

πŸŽ€ EXAMPLES πŸŽ€

  • Get the Reservation Notification log and print it in a human readable format:
# nvme log resv-notif /dev/nvme0
  • Print the output in json format:
# nvme log resv-notif /dev/nvme0 -o json

πŸ‘‘ NVME πŸ‘‘

Part of the nvme-user suite. πŸ˜­πŸ’–


That’s the whole page, bestie β€” source/version NVMe, dated 10/30/2026, page NVME-LOG-RESV-NOT(1). Go get that log! πŸ¦‹βœ¨