READ(1)

๐ŸŒธ READ(1) โ€” the read page, User Commands edition ๐ŸŒธ

okay bestie, welcome to read(1), the manual page for the chartread command ๐Ÿ’… this whole page is filed under User Commands, so you already know it's giving main character energy in your terminal.


๐ŸŽ€ NAME ๐ŸŽ€

Read โ€” Read Target Test Chart. that's it, that's the name, and honestly? iconic. โœจ


๐Ÿ’– DESCRIPTION ๐Ÿ’–

Read Target Test Chart ๐ŸŒˆ

yes bestie, that's genuinely the entire description. short. sweet. mysterious. it's giving "no notes". ๐Ÿฆ‹


โœจ SYNOPSIS โœจ

chartread [-options] outfile

so the whole vibe is: you run chartread, you hand it some options if you're feeling spicy, and you give it an outfile. periodt. ๐Ÿ‘‘


๐ŸŒŸ OPTIONS ๐ŸŒŸ

okay so here's the full menu, no skips, no cuts, every single one fr fr ๐Ÿ“

  • -v โ€” Verbose mode. she talks more. we love a chatty queen ๐Ÿ’ฌ
  • -c listno โ€” Set the communication port from the following list. default is 1. and the list is... this:
    • ** No ports found **
๐Ÿ’€ not a single port detected, bestie. that's literally what it prints. the list is empty, i don't make the rules.
  • -t โ€” Use transmission measurement mode. light goes through, slay โœจ
  • -d โ€” Use display measurement mode, and the results are white Y relative. ๐Ÿ–ฅ๏ธ
  • -e โ€” Emissive for transparency on a light box. ๐ŸชŸ
  • -p โ€” Measure patch by patch rather than strip. one at a time, she's thorough ๐ŸŽฏ
  • -x [lx] โ€” Take external values, either L*a*b* (-xl) or XYZ (-xx). ๐ŸŒˆ
  • -n โ€” Don't save spectral information. (heads up: the default does save spectral, so this is you actively opting out ๐Ÿ™ˆ)
  • -l โ€” Save CIE as D50 L*a*b* rather than XYZ. ๐Ÿ’›
  • -L โ€” Save CIE as D50 L*a*b* as well as XYZ. both. she said why not ๐Ÿ’…
  • -r โ€” Resume reading a partly read chart. picking up where you left off, we love a comeback arc ๐Ÿซถ
  • -I file.cal โ€” Override calibration info from .ti2 in the resulting .ti3. ๐Ÿ“
  • -F filter โ€” Set filter configuration (if aplicable):
    • n โ€” None
    • p โ€” Polarising filter
    • 6 โ€” D65
    • u โ€” U.V. Cut
  • -N โ€” Disable initial calibration of the instrument, if possible. ๐Ÿšซ
  • -B โ€” Disable auto bi-directional strip recognition. ๐Ÿ”„๐Ÿšซ
  • -H โ€” Use high resolution spectrum mode, if available. ๐Ÿ”ฌโœจ
  • -X file.ccmx โ€” Apply Colorimeter Correction Matrix. ๐Ÿงฎ
  • -X file.ccss โ€” Use Colorimeter Calibration Spectral Samples for calibration. ๐Ÿงช
  • -Q observ โ€” Choose the CIE Observer for the CCSS instrument. your picks are: 1931_2 (the default, def), 1964_10, S&B 1955_2, shaw, J&V 1978_2. ๐Ÿ‘€
  • -T ratio โ€” Modify strip patch consistency tolerance by ratio. โš–๏ธ
  • -S โ€” Suppress wrong strip & unexpected value warnings. (living dangerously, honestly, but do you ๐Ÿซฃ)
  • -W n|h|x โ€” Override serial port flow control: n = none, h = HW, x = Xon/Xoff. ๐Ÿ”Œ
  • -D [level] โ€” Print debug diagnostics to stderr. ๐Ÿ›
  • outfile โ€” Base name for the input[ti2] / output[ti3] file. ๐Ÿ“
๐ŸŒˆ little side note bestie: yes, -X shows up twice on purpose up there โ€” once for the .ccmx matrix and once for the .ccss samples. two completely different jobs, same letter. she contains multitudes ๐Ÿ’œ

that's the whole page, you made it ๐ŸŽ‰ this one's brought to you by chartread, dated September 2014, and it lives in the READ(1) corner of your manual. go read a chart, bestie, you got this ๐Ÿ’–โœจ๐ŸŽ€